• Title/Summary/Keyword: Chon spot

Search Result 19, Processing Time 0.024 seconds

A Study on Inyeong·Chon spot pulse(人迎氣口脈) about application of Ohaeng-acupuncture(五行鍼法) (인영기구맥진법(人迎氣口脈診法)의 오행침(五行鍼) 운용에 관한 고찰)

  • Park, Sa-hyun;Shin, Jeong-cheol;Ryu, Chung-ryul;Cho, Myung-rae
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.149-157
    • /
    • 2004
  • Objective : The purpose of this study is to research whether Inyeong Chon spot pulse(人迎氣口脈) could be used on application of Ohaeng-acupuncture(五行鍼法). Methods : I research ${\ll}$Naegyeong${\gg}$(內經) and annotations were excerpted and record that notied the Inyeong Chon spot pulse(人迎氣口脈). Results : Comparison of Inyeong Chon spot pulse and Deficiency Excess syndrome of meridian system is useful to use Zheng Ge(正格) and Sheng Ge(勝格) of Ohaeng-acupuncture(五行鍼法) but in application of Han Ge(寒格) and Re Ge(熱格), Inyeong Chon spot pulse(人迎氣口脈) is not useful.

  • PDF

Four case of Liver fire.Phlegm-fire Tinnitus treated by Axupuncture Therapy with the Inyeong.the chon spot comparison pulse diagnosis (인영촌구 비교맥진을 통한 간화 담화성 이명환자 침 치료4례)

  • Weon, Young-Ho;So, Woong-Ryong;Lee, Sun-Ho;Kim, Jae-Gwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.183-189
    • /
    • 2002
  • Tinnitus is usually due to insufficiency of Kidney-essence, asthenia of the Spleen and Stomach, diseases caused by exogenous pathogenic factor, Liver fire(肝火) by severe stress, Phlegm -fire(痰火) by surfeit of high caloric food and alcoholic liquor. I observed and treated four patients who had been diagnosed with tinnitus of Liver-fire(肝火) and Phlegm-fire(痰火). After I checked the Inyeong(人迎) and the chon spot(寸口), all of their Inyeong were stronger than chon spot. Unbalance of the Inyeong(人迎) and the chon spot(寸口), and symptoms of tinnitus were removed by Acupuncture therapy of three Yang meridians of the hand(手三陽) and three Yang meridians of the foot(足三陽).

  • PDF

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

The Study on Three-portion and Nine-position Pulse Taking Diagnosis (삼부구후진단(三部九候診斷)에 대한 고찰(考察);"내경"과 "난경"을 중심으로)

  • Eom, Dong-Myung
    • Journal of Korean Medical classics
    • /
    • v.20 no.3
    • /
    • pp.57-65
    • /
    • 2007
  • This present study tried to observe an each feature that the difference of Neijing(內經) and Nanjing(難經) descriptions about the three-portion and nine-position pulse taking(三部九候脈). It was interpreted and contradistinguished that discrimination of position, diagnosis object, and the perceptions of Earth of the center among the Five Phase of each literature were described in Neijing and Nanjing for the three-portion and nine-position(三部九候). In Neijing, the three-portion and nine-position method divided three parts the whole body. Then the each three parts again divided with Heaven, Earth and Man(天地人). About the corresponding parts of pulse diagnosis, there mentioned for the head and the Zang-Fu organs(臟腑), but not mentioned for the hand and foot. In addition, Earth is assigned to the Earth(土), an each Earth accounted for the source of life. In Nanjing, three-portion divided Chon, Gwan, and Cheok(寸關尺) and each spots separated three stage of pulse taking. For the pulse taking spots and diagnosis, there mentioned the hand and foot instead of the unclear mention of Zang-Fu organs. Then Gwan spot and middle stage of pulse taking were assigned to the Earth, respectively. It was emphasized stomach Qi(胃氣) that the region of Earth, Gwan spot and middle stage among the pulse taking spots each literature were described in Neijing, Nanjing.

  • PDF

Proposal for Pulse Diagnosis Positions (Chon-Kwan-Chuk) for Pulse Analyzer Based on Literature Review and Anthropometry (문헌고찰 및 실측에 근거한 맥진기 측정시 촌관척 정위에 대한 제안)

  • Kim, Hyun-Ho;Lee, Jeon;Kim, Ki-Wang;Kim, Jong-Yeol
    • The Journal of Korean Medicine
    • /
    • v.28 no.3 s.71
    • /
    • pp.13-22
    • /
    • 2007
  • Objectives : To obtain pulse information, oriental medical doctors usually use the three finger pulse diagnosis method. Although the diagnostic positions are very important, the exact positions are not known because of the uncertain conversion of measures of length (bun, chon, chuk) and misunderstanding of the related concepts of oriental medicine. In this study, we proposed relative positions for the detection of three pulses with a pulse analyzer. Methods : The proposal was made based mainly on several literature reviews, especially the original texts, and the examination of anthropometric characteristics of 78 individuals. Results : The Kwan is the spot where the radial pulse can be felt well near the eminent head of the radius at wrist, high bone. The position of Chon should be apart from Kwan by 6/10 distance between the high bone and wrist joint of each individual. Finally, the position of Chuk is apart from Kwan by 6.5/100 distance between the high bone and the elbow joint of each individual. Conclusions : Adapting those proposed positions for measuring three pulses can provide more consistent information to what an oriental doctor obtains than a pulse analyzer applied to other positions.

  • PDF

Increasing Production in Korean Shrimp Farms with White-Spot Syndrome Virus PCR-Negative Brood Stock

  • Seok, Seung-Hyeok;Baek, Min-Won;Lee, Hui-Young;Kim, Dong-Jae;Chun, Myung-Sun;Kim, Jong-Sheek;Chang, Se-Ok;Park, Jae-Hak
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.511-515
    • /
    • 2007
  • White-spot syndrome virus (WSSV) is a devastating, infectious virus affecting shrimp. Although sensitive techniques involving PCR have been developed to assist farmers in screening shrimp (brood stock) for WSSV prior to stocking ponds, such practices have not yet been applied in Korea. Despite the rationality of implementing screening, there has been some doubt as to whether the stocking of WSSV-PCR-negative fly epidemiologically decreases white-spot disease outbreaks. Here, we report a retrospective analysis of data from shrimp farms in the western coast of Korea where WSSV-PCR-negative brood stocks were used to stock rearing ponds. A total of 366 shrimp from Heuksan Island were sampled for WSSV with PCR. Of the tested shrimp, 7.2% (28 brood stocks) were identified as WSSV positive; only WSSV-PCR-negative shrimp were used for brood stocks. Total unit production (final shrimp production/ the area of the ponds) was higher, at 1.96, in ponds where WSSV-PCR-negative shrimp were used, as compared with 1.02 in other ponds in Korea in 2004. This retrospective analysis of WSSV in Korea may be useful to the shrimp aquaculture industry, suggesting a testable hypothesis that may contribute to the eventual control of WSSV outbreaks.

Low-Cost Hologram Module for Optical Pickup by Adjusting Photodiode Package (포토 다이오드 조정방식을 이용한 광 픽업용 저가 홀로그램 모듈)

  • Jeong, Ho-Seop;Kyong, Chon-Su
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.345-353
    • /
    • 2005
  • We proposed a new and cost-effective method fer assembling holographic pickup modules without any high resolution vision system. Assembling was accomplished by adjusting photodiode package only, leading to a low cost, holographic pickup module. Focus and tracking error signals were simply determined by comparing spot sizes and by using the 3 beam method, respectively, based on four-sectional holographic optical elements. In experiment, we assembled a hologram module and estimated performance of the proposed method fur a holographic pickup module used in compact disc system.

Hydraulic Model Test for Bridge Stability Analysis at Downstream of Chun-Chon Dam (춘천(春川)댐 방류시(放流時) 교량(橋梁)의 안정성(安定性) 검토(檢討)를 위한 수리모형실험(水理模型實驗) 연구(硏究))

  • Choi, Han-Kyu;Beak, Hyo-Seon;Choi, Sang-Soon
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.117-122
    • /
    • 2004
  • In The case of the bridge which is located in the downstream of the dam, effect of the running water and stability of the bridge is studing by using the Hydraulic model test. 1. The water level change of 'Seosang1 bridge' along Chunchon dam spill occurred through this experiment more greatly than a numerical conspiracy. 2. Bight is the spot where a difference occurs in located bridge piers(p18-p28) greatly, and an influence of Chunchon dam occurs in greatly.

  • PDF

Analysis of Radiation Dose for Lens, Thyroid Gland, Breast, and Gonad on Upper Gastrointestinal Series (위장조영검사에서 수정체, 갑상선, 유방, 생식선에 대한 피폭선량 분석)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.889-894
    • /
    • 2019
  • Upper gastrointestinal series is an examination that uses X-rays. It is important to defend against exposure to radiation during upper gastrointestinal examination because the organs, such as thyroid gland, lens, breasts, and gonads, with relatively high biological sensitivity to radiation are distributed on the examination area. We have made a whole body phantom that can change the depth of organs. radiation dose of eye, thyroid gland, breast and gonads were measured by the same procedure as the actual upper gastrointestinal examination. When performed only fluoroscopy the mean dose reduction of lens, thyroid gland, breast and gonads was 62.2%. The mean dose reduction of lens, thyroid gland, breast and gonads was 59.0% when both fluoroscopy and spot shoot were performed. Therefore, when performed upper gastrointestinal examination it was confirmed that shielding of the lens, thyroid gland, breast and gonads was effective in decreasing the exposure dose. The manufactured human phantom can be used in measuring radiation dose for deep organ because it can adjust the height corresponding to the organs located in the human body.

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.