• Title/Summary/Keyword: Cho Ji-hoon

Search Result 707, Processing Time 0.024 seconds

The Effect of Feeding TMR with Sasa quelpaertensis Nakai on the Body Weight and Blood Composition of the Horse (제주조릿대(Sasa quelpaertensis Nakai) 첨가 TMR 급여가 말의 체중 및 혈액 성상 특성에 미치는 영향)

  • Woo, Jae-Hoon;Park, Nam geon;Shin, Sang-Min;Yoo, Ji Huyn;Shin, Moon-Cheol;Cho, In Cheol;Yang, Byung-Chul;Kim, Nam-Young;Hwang, Won-Uk
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.203-208
    • /
    • 2020
  • This experiment was conducted to investigate the effects of feeding TMR(Total Mixed Ration) with Sasa quelpaertensis Nakai of Jeju cross-bred horses on the body weight and blood composition. Fourteen herds of Jeju cross-bred horses older than 36 months were selected as experimental animals. The experiment was conducted by dividing the herds into seven herds for feeding TMR with 20% Sasa quelpaertensis Nakai(treatment) and another seven herds for feeding TMR without Sasa quelpaertensis Nakai(control) and water were fed ad libitum. In the 12th week, the MPV(mean platelet volume) was statistically significantly higher with Sasa TMR than with control (p<0.05). However, both MPV levels are within a normal range and there were no health problems. With regard to the levels of cholesterol, there was a statistically significant difference between the 33.8±5.9 mg/㎗ with individual management and 25.4±8.2 mg/㎗ with control group (p<0.05). But It are also within a normal range and there were no health problems. In conclusion, feeding TMR with 20% Sasa quelpaertensis Nakai of Jeju cross-bred horses could be utilized as a feeding method for horse.

A Direction of the Monitoring of Household Chemical Products in Aquatic Environments: The Necessities for a Trophic Magnification Factor (TMF) Research on Fish (다양한 수생태계에 적용 가능한 유해물질의 영양확대계수 (trophic magnification factor, TMF) 연구 - 생활화학제품에서 기인한 성분과 어류조사를 중심으로)

  • Eun-Ji Won;Ha-Eun Cho;Dokyun Kim;Seongjin Hong;Kyung-Hoon Shin
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.3
    • /
    • pp.185-200
    • /
    • 2022
  • The risk of various hazardous substances in aquatic environment comprises not only the concentration of substances in the environmental medium but also their accumulation in fish through complex food web and the health risks to humans through the fish. In Korea, the monitoring of residual toxicant in aquatic ecosystems began in 2016 following the enforcement of the Acts on registration and evaluation for the management of chemicals used in daily life (consumer chemical products), and attention has been paid to potentially hazardous substances attributed to them. Recently, studies have been carried out to investigate the distribution of these hazardous substances in the ecosystem and calculate their emission factors. These include the accumulation and transport of substances, such as detergents, dyes, fragrances, cosmetics, and disinfectants, within trophic levels. This study summarizes the results of recently published research on the inflow and distribution of hazardous substances from consumer chemical products to the aquatic environment and presents the scientific implication. Based on studies on aquatic environment monitoring techniques, this study suggests research directions for monitoring the residual concentration and distribution of harmful chemical substances in aquatic ecosystems. In particular, this study introduces the directions for research on trophic position analysis using compound specific isotope analysis and trophic magnification factors, which are needed to fulfill the contemporary requirements of selecting target fish based on the survey of major fish that inhabit domestic waters and assessment of associated health risk. In addition, this study provides suggestions for future biota monitoring and chemical research in Korea.

Improvement of the Efficacy Test Methods for Hand Sanitizers (Gel, Liquid, and Wipes): Emerging Trends from in vivo/ex vivo Test Strategies for Application in the Hand Microbiome (손소독제(겔형, 액제형, 와이프형)의 효능 평가법 개선: 평가 전략 연구 사례 및 손 균총 정보 활용 등 최근 동향)

  • Yun O;Ji Seop Son;Han Sol Park;Young Hoon Lee;Jin Song Shin;Da som Park;Eun NamGung;Tae Jin Cho
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Skin sanitizers are effective in killing or removing pathogenic microbial contaminants from the skin of food handlers, and the progressive growth of consumer interest in personal hygiene tends to drive product diversification. This review covers the advances in the application of efficacy tests for hand sanitizers to suggest future perspectives to establish an assessment system that is optimized to each product type (gel, liquid, and wipes). Previous research on the in vivo simulative test of actual consumer use has adopted diverse experimental conditions regardless of the product type. This highlights the importance of establishing optimal test protocols specialized for the compositional characteristics of sanitizers through the comparative analysis of test methods. Although the operational conditions of the mechanical actions associated with wiping can affect the efficacy of the removal and/or the inactivation of target microorganisms from the skin's surface, currently there is a lack of standardized use patterns for the exposure of hand sanitizing wipes to skin. Thus, major determinants affecting the results from each step of the overall assessment procedures [pre-treatment - exposure of sanitizers - microbial recovery] should be identified to modify current protocols and develop novel test methods. The ex vivo test, designed to overcome the limited reproducibility of in vivo human trials, is also expected to replicate the environment for the contact of sanitizers targeting skin microorganisms. Recent progress in the area of skin microbiome research revealed distinct microbial characteristics and distribution patterns after the application of sanitizers on hands to establish the test methods with the perspectives on the antimicrobial effects at the community level. The future perspectives presented in this study on the improvement of efficacy test methods for hand sanitizers can also contribute to public health and food safety through the commercialization of effective sanitizer products.

Study of nosocomial rotavirus infection in neonates admitted to a postpartum-care center (서울시내 1개 산후 조리원에서 시행한 로타바이러스 선별검사에 대한 분석)

  • Park, Ji Young;Kim, Dong Hwan;Bae, Seung Young;Choi, Chang Hee;Cho, Eun Young;Choi, Jeong Hoon;Kim, Sun Mi
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.2
    • /
    • pp.145-154
    • /
    • 2007
  • Purpose : Rotavirus is one of the most important etiologic agents of nosocomial infections among the neonates. This study was designed to investigate nosocomial rotavirus infection in neonates who were admitted to a postpartum-care center after birth. Methods : From March 2005 to September 2006, 957 healthy neonates were examined for rotavirus antigen in stool by immunochromatographic method and 216 neonates were rotavirus antigen positive within 24 hours after admitted to a postpartum-care center. We reviewed the nursing charts retrospectively such as characteristics, monthly distribution, birth hospitals, delivery methods, feeding types and clinical manifestations. Results : Among 957 neonates, 216 neonates (22.6%) were rotavirus antigen positive and there were no differences in sex, birth weight, gestational age. Monthly positive rate of rotavirus antigen showed diversity from 10% to 36%. According to birth hospitals, positive rate showed diversity from 3.5% to 53.6%. Out of 957 neonates, 655 cases (68.4%) were born of vaginal delivery and mean hospitalized duration was 2.4 days, 302 cases (31.6%) were born of cesarean section and mean hospitalized duration was 5.7 days. 17.6% of vaginal delivery and 33.4% of cesarean section were rotavirus antigen positive. The positive rate was higher in neonates by cesarean section than vaginal delivery (P<0.001). According to feeding types, positive rate of rotavirus antigen was lower in breast-fed group than formula-fed group (P<0.001). Proportion of symptomatic case among rotavirus antigen positive was 34.7%. Most common clinical manifestation was diarrhea (61.3%), following poor feeding (45.3%), fever (40.0%), vomiting (25.3%), delayed weight gain (12.0%), and decreased urine amount (5.3%). Conclusion : Some neonates were already infected before admission to a postpartum-care center. Without meticulous management, nosocomial rotavirus infection would transmit rapidly in a postpartum-care center spreading to the community. Recommendation of breast-feeding, routine rotavirus screeing test with or without symptom, and isolation of all rotavirus antigen positive neonates in a postpartum-care center seem to be necessary. Also attentive hygiene education and further investigations of rotavirus infection in a postpartum-care center would be needed.

  • PDF

Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery (방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구)

  • Kim, Mi-Sook;Ha, Seong-Hwan;Lee, Dong-Han;Ji, Young-Hoon;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Seo, Young-Seok;Park, Chan-Il;Kim, Il-Han;Ye, Seong-Jun;Park, Jae-Hong;Kim, Kum-Bae
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.268-277
    • /
    • 2007
  • Purpose: Respiratory motion is a considerable inhibiting factor for precise treatment with stereotactic radiosurgery using the CyberKnife (CK). In this study, we developed a moving phantom to simulate three-dimensional breathing movement and investigated the distortion of dose profiles between the use of a moving phantom and a static phantom. Materials and Methods: The phantom consisted of four pieces of polyethylene; two sheets of Gafchromic film were inserted for dosimetry. Treatment was planned to deliver 30 Gy to virtual tumors of 20, 30, 40, and 50 mm diameters using 104 beams and a single center mode. A specially designed robot produced three-dimensional motion in the right-left, anterior-posterior, and craniocaudal directions of 5, 10 and 20 mm, respectively. Using the optical density of the films as a function of dose, the dose profiles of both static and moving phantoms were measured. Results: The prescribed isodose to cover the virtual tumors on the static phantom were 80% for 20 mm, 84% for 30 mm, 83% for 40 mm and 80% for 50 mm tumors. However, to compensate for the respiratory motion, the minimum isodose levels to cover the moving target were 70% for the $30{\sim}50$ mm diameter tumors and 60% for a 20 mm tumor. For the 20 mm tumor, the gaps between the isodose curves for the static and moving phantoms were 3.2, 3.3, 3.5 and 1.1 mm for the cranial, caudal, right, and left direction, respectively. In the case of the 30 mm tumor, the gaps were 3.9, 4.2, 2.8, 0 mm, respectively. In the case of the 40 mm tumor, the gaps were 4.0, 4.8, 1.1, and 0 mm, respectively. In the case of the 50 mm diameter tumor, the gaps were 3.9, 3.9, 0 and 0 mm, respectively. Conclusion: For a tumor of a 20 mm diameter, the 80% isodose curve can be planned to cover the tumor; a 60% isodose curve will have to be chosen due to the tumor motion. The gap between these 80% and 60% curves is 5 mm. In tumors with diameters of 30, 40 and 50 mm, the whole tumor will be covered if an isodose curve of about 70% is selected, equivalent of placing a respiratory margin of below 5 mm. It was confirmed that during CK treatment for a moving tumor, the range of distortion produced by motion was less than the range of motion itself.

Global Charity Operations of Cleft Lip and Palate by Korean Cleft Lip and Palate Association ; Charity Operations in Kenya, east Africa (대한구순구개열학회의 글로벌 자선 수술 활동 : 케냐에서의 자선 수술 활동)

  • Choung, Pill-Hoon;Park, Joo-Young;Park, Joo-Young;Ahn, Kang-Min;Baek, Jin-Woo;Cho, Il-Hwan;Choi, Cheol-Min;Choi, Seon-Hyu;Chung, Il-Hyuk;Gao, En-Feng;Hong, Jong-Rak;Hyun, Seung-Don;Jang, Hyon-Seok;Jun, Sang-Ho;Jung, Sung-Uk;Kang, Na-Ra;Kang, Young-Ho;Kim, Byung-Ryul;Kim, Dong-Hyun;Kim, Eun-Seok;Kim, Ho-Sung;Kim, In-Soo;Kim, Ji-Hyuck;Kim, Jong-Ryoul;Kim, Joong-Min;Kim, Myung-Jin;Kim, Soung-Min;Ko, Bong-Hwa;Koh, Sung-Hee;Lee, Bu-Kyu;Lee, Eui-Seok;Lee, Jong-Ho;Lee, Ui-Lyong;Lee, Won;Lee, Won-Deok;Min, Byong-Il;Nam, Il-Woo;Paeng, Jun-Young;Park, Jong-Chul;Park, Jung-Seok;Park, Sung-Hee;Park, Young-Wook;Pyo, Sung-Woon;Rim, Chae-Hong;Rim, Jae-Suk;Seo, Byoung-Moo;Suh, Je-Duck;Yoon, Jeong-Ho;Yoon, Jung-Ju;Yun, Hyung-Jin
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.9 no.2
    • /
    • pp.85-92
    • /
    • 2006
  • Korean Cleft Lip and Palate Association (KCLPA) was founded in 1996. The first overseas charity operation was in Karachi, Pakistan, 2002 and our association has visited fourteen times in six countries for the free cleft surgery: Pakistan, Egypt, Kenya, Morocco, Jordan and Vietnam. The cumulated number of operated patients reaches to 280. Before our association, many Korean oral and maxillofacial surgeons have performed charity operations individually since 1964. It was started from Vietnam but the activity is now carried on in Africa, middle-east Asia, south-east Asia, China, and Korea as an official team. LG electronics, a Korean company helped to propagate our team's activity to middle-east Asia to Africa. This paper is a report concerning about the results of our association's charity activities especially in Kenya, east Africa. We provided free cleft surgery for 30 patients in 2004 and 27 patients in 2005, in Nairobi. As the blood test for HIV of the cleft patients was not allowed before and during surgery, our surgeons and nurses were cautious about every movement during the surgeries. Thus the operation time for each patient was longer than any other time. The attitude of the local hospital and the doctors seemed to be accustomed to this situation. They helped us in case of needle injuries. Safety of medical staff and patients is more important than the number of the patients operated in charity operation. This belief should be approached being parallel and multidisciplinary as an international cooperation, focusing on international funding for medical support and continuous education for local doctors who are willing to devote to their people.

  • PDF

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF