• Title/Summary/Keyword: Chlorine effect

Search Result 369, Processing Time 0.024 seconds

Effect of Sodium Hypochlorite for Controlling Bacterial Blotch on Pleurotus ostreatus

  • Oh, Se-Jong;Kim, Han-Kyoung;Kim, Hee-Kyu;Fermor, T.R.
    • Mycobiology
    • /
    • v.28 no.3
    • /
    • pp.123-126
    • /
    • 2000
  • Sodium hypochlorite alkaline was tested against Pseudomonas tolaasii causing bacterial blotch on cultivated oyster mushroom (Pleurotus ostreatus). The minimum inhibitory concentration of sodium hypochlorite against P. tolaasii contained active chlorine (AC) at 1.4 mg/l on plate assay. The highest cultivation yield was obtained from the treatment of AC 5.7 mg/l. Treatment of sodium hypochlorite at the rate of higher than AC 11.4 mg/l resulted in reduced yields at the harvest. However, the population of total bacteria on the bed surface treated with AC 5.7 mg/l of sodium hypochlorite was maintained to some extent. Inhibitory concentration against total bacteria on the bed surface was over AC 22.8 mg/l. Mushroom mycelium was damaged and its growth strongly inhibited at the concentration of AC 200 mg/l. Mushroom caps showed yellowish symptom by chemical injury by treatments of AC 74.1 mg/l or higher. Sporocarps infected by P. tolaasii were irrevocable at any concentration of sodium hypochlorite. Routine watering with AC 5.7 mg/l from mushroom initiation to the end of picking resulted in reduced bacterial blotch incidence of 40% and 86% at two mushroom farms. The treatment resulted in higher quality mushroom production compared to that conventionally watered with tap water alone.

  • PDF

Water Quality Alteration during Passing through Small Water Tank and Improvement of Tap Water Quality by Direct Connection Service (옥상물탱크 경유에 따른 수돗물 수질 변화 및 직결급수방식 도입에 의한 수질개선 효과 연구)

  • Lee, Mok-Young;Chang, Hyun-Jung;Lee, Eu-Kwang;Oh, Se-Jong;Lee, Chae-Keun;Lee, Hyun-Dong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.328-336
    • /
    • 2000
  • In order to compare the effect of water quality on two service systems, tank and direct connection service, we selected randomly 30 rooftop tanks installed in the buildings with five or fewer floors, and collected water samples from each tank as well as tap water by direct service. At the same time each tank was investigated on their cleanliness and sanitary control. 30 water samples from direct service met Korean Drinking water quality standard. But 5 tank water samples(17%) were not able to meet Coliform or Total Colony Counts standard and free chlorine of 12 tank water samples(40%) were less than 0.2mg/L. Also Fe, Turbidity, TOC, Total Algae in tank water were higher than tap water on direct service. We concluded that thorough health control of water tank is necessary and conversion into direct connection service results in improving tap water quality importantly.

  • PDF

Reduction of Pesticide Residues in the Production of Red Pepper Powder

  • Chun, Mi-Hwa;Lee, Mi-Gyung
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Six organophosphorus, one organochlorine, and three synthetic pyrethroid pesticides were analyzed for their residues during washing and hot-air drying of red peppers conducted in the production of powder. The residue ratio in organophosphorus pesticides was 33% in chlorpyrifos, 31 % in diazinon, 50% in methidathion, 80% in EPN, 28% in fenitrothion, and 60% in profenofos. The ratio in pyrethroids was 109% in cypermethrin, 102% in deltamethrin, and 106% in fenvalerate. That in organochlorine was 56% in ${\alpha}$-endosulfan and 90% in ${\beta}$-endosulfan. The results were greatly different between organophosphorus and pyrethroid pesticides. UV irradiation along with hot-air drying brought about a remarkable reduction of the residues, up to 70% as compared with hot-air drying only. The removal effect was most remarkable in pyrethroids, which are hardly removed by hot-air drying. The color of the pepper was not changed during UV irradiation. The use of oxidizing agents such as hydrogen peroxide or chlorine dioxide during washing did not show a remarkable removal of residues. The residue ratio was not affected whether the pesticide is contaminated artificially or naturally.

Estimation of Tribological Properties on Surface Modified SiC by Chlorine Gas Reaction at Various Temperatures (다양한 온도에서 염소가스 반응에 의해 표면 개질된 SiC의 트라이볼로지 특성평가)

  • Bae, Heung-Taek;Jeong, Ji-Hoon;Choi, Hyun-Ju;Lim, Dae-Soon
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.515-519
    • /
    • 2009
  • Carbon layers were fabricated on silicon carbide by chlorination reaction at temperatures between $1000^{\circ}C$ and $1500^{\circ}C$ with $Cl_2/H_2$ gas mixtures. The effect of reaction temperature on the micro-structures and tribological behavior of SiC derived carbon layer was investigated. Tribological tests were carried out ball-on-disk type wear tester. Carbon layers were characterized by X-ray diffractometer, Raman spectroscopy and surface profilometer. Both friction coefficients and wear rates were maintained low values at reaction temperature up to $1300^{\circ}C$ but increased suddenly above this temperature. Variation of surface roughness as a function of reaction temperature was dominant factor affecting tribological transition behavior of carbon layer derived from silicon carbide at high temperature.

Disinfection Characteristics of Waterborne Pathogenic Protozoa Giardia lamblia

  • Kim, Kyongjoo;Wooksun Hong;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.6 no.2
    • /
    • pp.95-99
    • /
    • 2001
  • Giardia lamblia is a parasitic protozoa which is transmitted in the form of a cyst through untreated water and also treated drinking water. Since its presence in water has led to frequent outbreaks of giardiasis and death in many countries, the removal and disinfection of this protozoan cyst from the water supply are of great concern for public health. This study examined the disinfection characteristics of G. lamblia cysts isolated from a Korean patient with giardiasis. When using sodium hypochlorite including 5 or 10 ppm chlorine, the killing rate was initially rapid, however, the disinfection slowed down and a 3log reduction could not be achieved even after 2h. The disinfection effectiveness was also reduced at a lower temperature, thereby implying that the risk o a giardiasis outbreak will be higher in the winter season. A CT (concentration$.$time) curve was constructed based on the results with sodium hypochlorite for use in designing and predicting disinfection performance. The organic chlorination disinfectant SDIS (sodium dichloroisocyanurate) produced a lower pH and a much higher residual effect than sodium hypochlorite. The disinfection of cysts by SDIC continued steadily throughout 2h of contact, although the initial killing rate was lower than that with sodium hypochlorite.

  • PDF

A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3 I$ (HFC-152a와 HFC-1523에 $CF_3 I$를 혼합한 공비혼합냉매 특성에 관한 연구)

  • 이종인;하옥남;김재열;이연신;권일욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.102-108
    • /
    • 2001
  • To prevent green house effect and destruction of an ozone layer, an ozone destruction potential(OBP) must be zero and a refrigerant for low global warming potential(GWP) is needed. HFC-l34a, in which hydrogen is mixed instead of chlorine is a refrigerant used for automobile conditioners and its destruction potential is ecologically zero. However, it is not consid- ered as a perfect substitutive refrigerant as its GWP is high. It is studied refrigerant mixtures in which HFC-l52a and $CF_3 I$ in HFC-l52a with low GWP and zero ODP are mixed by experimentally and concluded as follows: 1) With the variation of speed of compressor outside temperature and flow rate, 7he heat of evaporator and compressor and coefficient of perfor- mance was varied, and influenced the air conditioner. 2) The pressure of evaporator was decreased with increasing the speed of compressor and the pressure of evaporator with the refrigerant HFC-l52a was higher 24% than that of azotrope refrigerant mixed with $CF_3 I$

  • PDF

Offsite Risk Assessment on Toxic Release (독성물질 저장설비의 사고시 사업장외에 미치는 영향평가)

  • Park, Kyoshik
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.9-16
    • /
    • 2017
  • Toxic release is one of the most interested area in evaluating consequence to the vicinity of industry facilities handling hazardous materials. Chloric acid production facility is selected and toxic release is evaluated to assess the risk impacted to its off-site. Accident scenarios were listed using process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling chloric acid is safe enough and needed no further protections at the moment.

Effect of CF4 Addition on Ferroelectric YMnO3Thin Film Etching (강유전체 YMnO3 박막 식각에 대한 CF4첨가효과)

  • 박재화;김경태;김창일;장의구;이철인
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.4
    • /
    • pp.314-318
    • /
    • 2002
  • The etching behaviors of the ferroelectric $YMnO_3$ thin films were studied by an inductively coupled plasma (ICP). The maximum etch rate of $YMnO_3$ thin film is 300 ${\AA}/min$ at Ar/$Cl_2$of 2/8, RF power of 800W, dc bias voltage of 200V, chamber pressure of 15mTorr and substrate temperature of $30^{\circ}C$. Addition of $CF_4$ gas decrease the etch rate of $YMnO_3$ thin film. From the results of XPS analysis, nonvolatile $YF_x$ compounds were found on the surface of $YMnO_3$ thin film which is etched in Ar/$Cl_2$/CF$_4$plasma. The etch profile of YMnO$_3$film is improved by addition of $CF_4$ gas into the Ar/$Cl_2$ plasma. These results suggest that YF$_{x}$ compound acts as a sidewall passivants which reduce the sticking coefficient of chlorine on $YMnO_3$.

Variation of hazardous substances in sewage ecotoxicological assessment (하수 원수내 유해물질 변화에 따른 생태독성평가)

  • Seo, Byong-Won;Lee, Ju-Hwa;Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.603-610
    • /
    • 2013
  • According to industrialization, increased toxic chemicals discharge has been causing water pollution. Especially domestic sewage is a major source of water pollution. Sixty percent of the total wastewater discharged is domestic sewage. Self-purification capacity of rivers and streams is drastically reduced by the emission of domestic sewage, industrial wastewater and livestock wastewater. Although domestic sewage is managed by implementing standards and regulations, toxicity effect of domestic sewage to humans and the environment is not yet clearly understood. In this study, by using daphnia magna, the ecotoxicity of domestic swage was assessed. Cl, Cu, Pb, COD, T-N, DO, pH and residual chlorine were investigated as background concentrations. The experiments were conducted with water samples obtained from three local sewage treatment plants. The experiment results indicated that higher level of toxicity corresponds to the higher pollution concentrations. The higher level of combinations of background concentrations such as heavy metals leads to the worse ecotoxicity. Especially, the Cu concentration affects the TU value.

Effect of Temperature on Electrochemical Characteristics of Stainless Steel in Green Death Solution Using Cyclic Potentiodynamic Polarization Test (순환동전위 분극실험을 이용한 스테인리스강의 그린데스용액에서 전기화학적 특성에 미치는 온도의 영향)

  • Hwang, Hyun-Kyu;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.266-280
    • /
    • 2021
  • Since 2020, the International Maritime Organization (IMO) has updated regulations on the sulfur content to be less than 0.5% in exhaust gas emitted from ships. Accordingly, the exhaust gas post-treatment device for ships, which is SOx/NOx reduction technology, was introduced. However, the exhaust gas post-treatment device is suffering corrosion because of the harsh corrosive environment formed by sulfate and chlorine oxide through the desulfurization process. In this investigation, cyclic potentiodynamic polarization (CPDP) experiment for UNS S31603 and UNS N08367 was performed in a green death solution that simulates the environment of a desulfurization device. The corrosion rate of UNS S31603 at the highest temperature was about 3 times higher than that of UNS N83067. Also, electron microscope scan revealed corrosion type UNS N83067 presents intergranular corrosion tendency. On the other hand, UNS S31603 was observed as general corrosion. The α values of UNS N08367 at 30 ℃ and 60 ℃ were higher than those of UNS S31603, thus UNS N08367 is considered to have a higher local damage tendency. Whereas, since the α value of UNS S31603 at 90 ℃ is larger than that of UNS N08367, UNS S31603 is considered to have a higher local damage trend.