• Title/Summary/Keyword: Chloride ions

Search Result 572, Processing Time 0.151 seconds

Conservation of copper objects in marine sites (해저 인양 구리 유물의 보존처리 연구)

  • Moon, Whan-Suk;Hwang, Jin-ju;Kim, Sun-Duk;Kang, Dai-Ill;Jung, Ki-Jung;Jung, Young-Dong
    • 보존과학연구
    • /
    • s.16
    • /
    • pp.41-58
    • /
    • 1995
  • Several comparisons of treatment methods for stabilizing corroded Chinese coins at Shin-an marine sites were investigated. In aqueous solution, the seexamination were performed to show whether chloride ions are gradually removed, patination changes are acceptable and archaeological details are identified. The six desalting methods showed that the orders of removal of chloride ions were ranked electrolysis (electolyte : 0.1M sodium sesqui.)> 5% sodium dithionite(1M NaOH)> 5%sodium dithionite(0.1M sesqui.)> 5% citric acid> 0.1M sodium sesquicarbonate>deionized water. As the examinations of moisture absorption to the relative humidity has compared for bronze disease, all of desalted coins for the R.H 53% and R.H 75%except to R.H 95% are showed serious bronze disease.

  • PDF

The Effect of Arabic Gum on the Copper Electrodeposition using Titanium Substrate (티타늄 기지을 이용한 구리 전해도금 시 Arabic Gum 첨가제의 영향)

  • Woo, Tae-Gyu;Park, Il-Song;Lee, Hyun-Woo;Seol, Kyeong-Won
    • Korean Journal of Materials Research
    • /
    • v.16 no.12
    • /
    • pp.725-730
    • /
    • 2006
  • The purpose of this study is to identify the effect of additives during copper electrodeposition. Additives such as arabic gum, chloride ions and glue were used in this study. Electrochemical experiments allied to SEM and roughness examination were performed to characterize of the copper foil in the presence of additives. In the production of electrodeposited copper foil, the surface roughness and grain size of the copper foil can be controlled by addition additives. on this study, the more uniform and hemispherical copper crystals are during the initial stages, the smaller crystal size and surface roughness of copper foil are. The surface roughness of copper foil electrodeposited at the current density of 500 $mA/cm^2$ under galvanostatic mode for 60 seconds has a minimum value of 0.136 ${\mu}$m when adding 2 ppm of arabic gum.

Characteristics of Water Soluble Ions in Fine Particles during the Winter and Spring in Daegu (대구지역 겨울철과 봄철 미세먼지의 수용성 이온성분 특성)

  • Park, Ji-Yeon;Lim, Ho-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.627-641
    • /
    • 2006
  • Atmospheric $PM_{2.5}$ and $PM_{10}$ were measured to investigate their levels and water-soluble ions(${SO_4}^{2-},\;{NO_3}^-,\;{NO_2}^-,\;Cl^-,\;{NH_4}^+,\;Na^+,\;Ca^{2+},\;Mg^{2+},\;and\;K^+$) in Daegu between February 17 and April 18, 2006. Four Asian dust episodes during the period were examined for the influence of Asian dust on the particulate properties. Daily $PM_{2.5}\;and\;PM_{2.5-10}$ concentrations ranged between $10.83{\sim}136.76{\mu}g/m^3$ with a mean of $38.43{\mu}g/m^3$ and $16.13{\sim}409.13{\mu}g/m^3$ with a mean of $79.98{\mu}g/m^3$, respectively. For all measured ions the mean fractions of $PM_{2.5}\;and\;PM_{2.5-10}$ were 51.8% and 28.9% being lowered to 30.7% and 9.4%, respectively, during the dust episodes. Secondary ions (i.e., non-sea salt ${SO_4}^{2-},\;{NO_3}^-,\;and\;{NH_4}^+$) contributed 44.3% and 14.8% to $PM_{2.5}\;and\;PM_{2.5-10}$, respectively, with a decreased contribution during the episodes. The average equivalent ratio of ${NH_4}^+$ to the sum of ${SO_4}^{2-}\;and\;{NO_3}^-$ was 0.99 and 0.89 for $PM_{2.5}\;and\;PM_{2.5-10}$, respectively, indicating high source strength of $NH_3$ and its dominance in the neutralization of the acidic ions. Correlations and charge balance between ions suggest that neutralization of the acidic ions results in substantial depletions of carbonate both in $PM_{2.5}\;and\;PM_{2.5-10}$ and chloride only in $PM_{2.5}$.

Power spectral density method performance in detecting damages by chloride attack on coastal RC bridge

  • Mehrdad, Hadizadeh-Bazaz;Ignacio J., Navarro;Victor, Yepes
    • Structural Engineering and Mechanics
    • /
    • v.85 no.2
    • /
    • pp.197-206
    • /
    • 2023
  • The deterioration caused by chloride penetration and carbonation plays a significant role in a concrete structure in a marine environment. The chloride corrosion in some marine concrete structures is invisible but can be dangerous in a sudden collapse. Therefore, as a novelty, this research investigates the ability of a non-destructive damage detection method named the Power Spectral Density (PSD) to diagnose damages caused only by chloride ions in concrete structures. Furthermore, the accuracy of this method in estimating the amount of annual damage caused by chloride in various parts and positions exposed to seawater was investigated. For this purpose, the RC Arosa bridge in Spain, which connects the island to the mainland via seawater, was numerically modeled and analyzed. As the first step, each element's bridge position was calculated, along with the chloride corrosion percentage in the reinforcements. The next step predicted the existence, location, and timing of damage to the entire concrete part of the bridge based on the amount of rebar corrosion each year. The PSD method was used to monitor the annual loss of reinforcement cross-section area, changes in dynamic characteristics such as stiffness and mass, and each year of the bridge structure's life using sensitivity equations and the linear least squares algorithm. This study showed that using different approaches to the PSD method based on rebar chloride corrosion and assuming 10% errors in software analysis can help predict the location and almost exact amount of damage zones over time.

Chloride Penetration Properties of Portland Cement Mortar Substituted with Anion Exchange Resin Powder (음이온교환수지 분말이 치환된 포틀랜드 시멘트 모르타르의 염소이온 침투 특성)

  • Lee, Yun-Su;Lim, Seung-Min;Park, Jang-Hyun;Jung, Do-Hyun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2020
  • Chloride ion, which penetrates into the cement composites from the outside, generally diffuses by the concentration gradient. Chloride ions are adsorbed by the chemical reaction with cement hydrates. Recent studies have shown that anion exchange resin (AER) powder can effectively adsorb the chloride ion in the cement composites, and thus, the cement composites containing AER have a high chloride adsorption capacity and a good resistance for chloride penetration. In this study, the chloride adsorption ability of the AER powder was investigated under the conditions of distilled water and calcium hydroxide saturated solution to determine if the AER powder is less effective to increase the chloride adsorption ability after grinding process. The chloride adsorption ability of AER powder was compared with the previous research about the chloride adsorption of AER bead. In addition, the compressive strength, chloride diffusion coefficient (using NT Build 492 method), and the chloride profile of cement mortar substituted with AER powder were investigated. There was no decrease in the chloride adsorption capacity of AER powder but increase in the kinetic property for chloride adsorption after the grinding process. The AER powder could absorb the chloride ion in the mortar quickly, and showed better chloride ion adsorption ability than the cement hydrates.

Investigation of Mechanical Behavior and Hydrates of Concrete Exposed to Chloride Ion Penetration (염해를 받은 콘크리트의 역학적 거동 및 수화 생성물 조사)

  • Yunsuk Kang;Gwihwan Lim;Byoungsun Park
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.381-390
    • /
    • 2023
  • In this study, the mechanical performance of concrete exposed to chloride ion penetration was investigated. And a compressive stress-strain model was presented. CaCl2 solution was added when mixing concrete to simulate long-term chloride ion penetration, and the concentration of chlorine ions was set to 0, 1, 2, and 4 % based on the weight of the binder. To investigate the compressive stress-strain curve after the peak stress of concrete, the compressive strength was measured by displacement control. When the chlorine ion concentration was 1 %, peak stress increased, but when the chlorine ion concentration was 2 % or more, peak stress decreased. In the case of peak strain, no trend according to chloride ion concentration was observed at 7 days. At 28 days, peak strain decreased as the chloride ion concentration increased. A compressive stress-strain curve model based on the Popovics model was presented using changes in peak stress and peak strain at 28 days. Microstructure analyses were performed to investigate the cause of the decrease in mechanical performance as the concentration of chlorine ions increased. It was confirmed that as the concentration of chlorine ion increased, Friedel's salt increased and portlandite decreased.

CU+ ION EXTRACTION FROM A MODIFIED BERNAS ION SOURCE IN A METAL-ION IMPLANTER

  • Hong, In-Seok;Lee, Hwa-Ryun;Trinh, Tu Anh;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.709-714
    • /
    • 2009
  • An ion implanter, which can serve as a metal-ion supply, has been constructed and performance tested. Copper ions are generated and extracted from a Bernas ion source with a heating crucible that provides feed gases to sustain the plasma. Sable arc plasmas can be sustained in the ion source for a crucible temperature in excess of $350^{\circ}C$. Stable extraction of the ions is possible for arc Currents less than 0.3 A. Arc currents increase with the induced power of a block cathode and the transverse field in the ion source. $Cu^+$ ions in the extracted beam are separated using a dipole magnet. A $20{\mu}A$ $Cu^+$ ion current can be extracted with a 0.2 A arc current. The ion current can support a dose of $10^{16}ions/cm^2$ over an area of $15\;cm^2$ within a few hours.

Electroanalytical Determination of Copper(II) Ions Using a Polymer Membrane Sensor

  • Oguz Ozbek;Meliha Burcu Gurdere;Caglar Berkel;Omer Isildak
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2023
  • In this study, a new potentiometric sensor selective to copper(II) ions was developed and characterized. The developed sensor has a polymeric membrane and contains 4.0% electroactive material (ionophore), 33.0% poly(vinyl chloride) (PVC), 63.0% bis(2-ethylhexyl)sebacate (BEHS) and 1.0% potassium tetrakis(p-chlorophenyl)borate (KTpClPB). This novel copper(II)-selective sensor exhibits a Nernstian response over a wide concentration range from 1.0×10-6 to 1.0×10-1 mol L-1 with a slope of 29.6 (±1.2) mV decade-1, and a lower detection limit of 8.75×10-7 mol L-1. The sensor, which was produced economically by synthesizing the ionophore in the laboratory, has a good selectivity and repeatability, fast response time and stable potentiometric behaviour. The potential response of the sensor remains unaffected of pH in the range of 5.0-10.0. Based on the analytical applications of the sensor, we showed that it can be used as an indicator electrode in the quantification of Cu2+ ions by potentiometric titration against EDTA, and can also be successfully utilized for the determination of copper(II) ions in different real samples.

ESTIMATION FOR DEWATERABILITY ON INTERACTION BETWEEN CATIONIC FLOCCULANTS AND IONIC MATERIALS IN DISSOLVING WATER

  • Bae, Young-Han;Lee, Sung-Sik
    • Environmental Engineering Research
    • /
    • v.11 no.5
    • /
    • pp.266-276
    • /
    • 2006
  • Commonly, the flocculant is dissolved in process or recycle water in industrial plant which has many ionic materials. Therefore, the polymer degradation in aqueous solution by chemical, mechanical or bacteriological may occur, sometimes rapidly. Even if the same flocculant is dissolved, the flocculation characteristics and the properties of dissolving polymer varied with the kind of dissolving water. In this study, we try to estimate the interaction between flocculants and ionic materials in dissolving water using self inversing emulsion polymer; polyacrylamide-co-trimethyl ammonium ethyl acrylate chloride flocculants which have varying molecular weights and structures at a several conditions. The polymeric flocculant is dissolved in artificial dissolving water with Potassium Chloride (PC), Calcium Chloride anhydrous (CC), Potassium Hydroxide (PH), Sodium Chloride (SC), Sodium Bromate (SB) and Iron (II) Sulfate Heptahydrate (IS) as ionic sources. Experimental results indicate that the cationic and anionic ions in dissolving water induce the hydrolysis, degradation of cationic functional group and uncoiling of polymeric flocculants, therefore, the flocculation efficiency decreased by undesired polymer. According that result, it is important to estimate not only its structures and physical properties but also the qualities of dissolving water to optimize the efficiency.

The Effects of Culture Conditions for Microbially Influenced Corrosion

  • Kim, Pill J.;Woo, Seung H.;Park, Jong M.
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.260-265
    • /
    • 2003
  • The experimental methods to rapidly and stably reproduce Microbially Influenced Corrosion (MIC) of stainless steel by sulfate-reducing bacteria such as Desulfovibrio vulgaris were developed. In this study, using two types of stainless steel, 304 and 444, obtained from Pohang Steel & Iron Co., Ltd. (POSCO)., three major factors were tested; overall medium composition, dilution ratio, and chloride concentration. In the overall medium tests, three different media were prepared according to $FeSO_4$ concentration; PM (original Postgate's medium No. 2), MPM 1 (modified PM, no $FeSO_4$, MPM 2 (modified PM, 1/10 $FeSO_4$). The effects of various dilution ratios (3, 1, 1/3, 1/10, 1/30, and 1/100 times) and chloride concentrations (0.0067M, 0.01M, 0.05M, and 0.1M) were examined during 2 months cultivation. Through SEM (Scanning Electron Microscopy) observation, the diluted and modified media, particularly the $1/3{\times}MPM$ I medium, showed more micro-pitting points on surfaces compared to the original PM medium. High concentrations of chloride ions (above 0.05M) were not adequate for observation of MIC since those brought about non-microbiologically induced corrosion. From this study, the optimization of medium composition was very effective to routinely observe MIC in a laboratory system.