• 제목/요약/키워드: Chiral capillary electrophoresis

검색결과 30건 처리시간 0.025초

Cyclodextrins' effect on the enatioseparation of some PPIs and capillary electrophoresis method development for determining rabeprazole enantiomers

  • Choi, Yusung;Pham, Thuy-Vy;Mai, Xuan-Lan;Truong, Quoc-Ky;Le, Thi-Anh-Tuyet;Nguyen, Thi-Ngoc-Van;Lee, Gunhee;Kang, Jong-Seong;Mar, Woongchon;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제32권5호
    • /
    • pp.185-195
    • /
    • 2019
  • Over the past decades, chiral switch of the proton pump inhibitors (PPIs) has been received widespread attention in therapeutic advantages as well as pharmaceutical analysis. In present study, the influence of cyclodextrins (CDs) on the chiral separation of four common PPIs (lansoprazole, omeprazole, pantoprazole, and rabeprazole) was investigated. The results demonstrated that capillary electrophoresis (CE) with dual CDs as a chiral selector system is a possible and promising method for the enantioseparation of these PPIs. Rabeprazole, which is the most challenging and acid-labile candidate among four PPIs, was selected for further development of the technique. To optimize CE condition, the effects of capillary parameters and background electrolytes on the enantioseparation were investigated. Finally, the best chiral separation was acheived by using sulfobutyl ether-${\beta}$-CD, and ${\gamma}$-CD as dual chiral selectors. The developed CE method not only provided the effective chiral separation but also showed the good stability of rabeprazole. The proposed method was successfully validated according to the International Conference on Harmonization guideline and effectively applied to determine rabeprazole enantiomers in commercial rabeprazole tablets, with recoveries ranging from 97.17 % to 103.29 % of the label content.

Chiral Separation of ${\beta}_2$-Agonists by Capillary Electrophoresis Using Hydroxypropyl-${\alpha}$-Cyclodextrin as a Chiral Selector

  • Kim, Kyeon-Ho;Kim, Hyu-Ju;Jeun, Eu-Young;Seo, San-Hun;Hong, Seon-Pyo;Kang, Jong-Seong;Youm, Jeong-Rok;Lee, Sang-Cheal
    • Archives of Pharmacal Research
    • /
    • 제24권4호
    • /
    • pp.281-285
    • /
    • 2001
  • Enantiomers of five racemic ${\beta}_2$-agonists were investigated by capillary electrophoresis employing a hydroxypropyl-${\beta}$-cyclodextrin (HP-${\beta}$-CD). The effects of the concentration of HP-${\beta}$-CD added to the background electrolyte and of the pH of the buffer on the effective mobility and resolution of the studied compounds were examined. Very good resolution was achieved for terbutaline and clenbuterol; salbutamol and bambuterol was able to be partially resolved. Enantioselectivity and resolution were influenced by the concentration of the HP-7-CD, buffer composition and pH.

  • PDF

Chiral Separation of ($\pm$)-Higenamine by Capillary Electophoresis

  • Choi, One-Kyun;Jung, Kyo-Soon;Choi, Heisook-Yun;Yang, Deok-Chun
    • Plant Resources
    • /
    • 제6권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Higenamine [1-(4-hydroxy-6, 7-dihydroxy-l, 2, 3, 4-tetrahydroisoquinoline) is a cardiotonic constituent of Aconiti tuber, one of the most widely prescribed oriental medicines. S-(-)higenamine was reported to have a stronger cardiotonic activity than R-(+)-higenamine and known as a central intermediate in the biosynthesis of various benzyl isoquionoline alkaloids in plants. The separation of higenamine enantiomers has been accomplished with capillary electrophoresis using cyclodextrins (CDs) as chiral selectors. Good resolution of this enantiomers was obtained using a 50 mM sodium phosphate buffer containing hydroxypropyl $\beta$-CDs using 27 cm fused silica capillary (50${\mu}{\textrm}{m}$ i.d., 20 cm to detector) at 25 $^{\circ}C$. With the electric field of 340 V/cm, the separation time of higenamine enantiomers was less than 6 min. Under this optimum conditions, the relative standard deviations of migration time and peak area were less than 1.6% and 3.2%. A 512-channel diode array detector was confirmed for the higenamine. The detection limits (S/N = 3) of these enantiomers are $1.5mutextrm{m}$/mL. We confirmed the chiral form of higenamine in medicinal plants.

  • PDF

Determination of Terbutaline Enantiomers in Human Urine by Capillary Electrophoresis Using $Hydroxypropyl-{\beta}-cyclodextrin$ as a Chiral Selector

  • Kim, Kyeong-Ho;Seo, Sang-Hun;Kim, Hyun-Ju;Jeun, Eun-Young;Kang, Jong-Seong;Mar, Woong-Chon;Youm, Jeong-Rok
    • Archives of Pharmacal Research
    • /
    • 제26권2호
    • /
    • pp.120-123
    • /
    • 2003
  • A method for the determination of terbutaline enantiomers in human urine by capillary elctrophoresis has been developed. Optimum resolution was achieved using 50 mM phosphate buffer, pH 2.5, containing 15 mM of hydroxypropyl-$\beta$-cyclodextrin as a chiral selector. Urine samples were prepared by solid-phase extraction with Sep-pak silica, followed by CE. The assay was linear between 2-250 ng/mL (R = 0.9998 for (S)-(+)-terbutaline and R = 0.9999 for (R)-(-)-terbutaline) and detection limit was 0.8 ng/mL. The intra-day variation ranged between 6.3 and 14.5% in relation to the measured concentration and the inter-day variation was 8.2-20.1%. It has been applied to the determination of (S)-(+)-terbutaline and (R)-(-)-terbutaline in urine from healthy volunteer dosed with racemic terbutaline sulfate.

Multivariate Optimization of a Sulfated- β-Cyclodextrin-Modified Capillary Zone Electrophoretic Method for the Separation of Chiral Arylalcohols

  • Zhang, Yu-Ping;Noh, Hyun-Joo;Choi, Seong-Ho;Ryoo, Jae-Jeong;Lee, kwang-Pill;Ohta, Kazutoku;Fujimoto, Chuzo;Jin, Ji-Ye;Takeuchi, Toyohide
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권3호
    • /
    • pp.377-381
    • /
    • 2004
  • Chiral separation of aryalcohols such as 1-phenyl-propanol, 1-phenyl-2-proanol, and 2-phenyl-1-propanol by capillary electrophoresis has been optimized using the overlapping resolution mapping (ORM) scheme. Three critical parameters of the electrophoretic media, i.e. phosphate concentration, sulfated ${\beta}$-cyclodextrin (CD) concentration and pH, were chosen for optimization. The working ranges were initially presumed by 7 preexperiments. Further optimization was carried out by another seven experiments within the narrow working ranges. From the final overlapping resolution mapping all peak pairs, the area of maximum separations were located. Using the conditions of a point in this area, we found that the target compounds were a baseline separated within 30 min. The maximum separation conditions of arylalcohols were a chiral selector concentration of 5.4%, a phosphate concentration of 28 mM, and a pH of 5.0.

모세관 전기 영동을 이용한 퀴놀린계 항생제의 광학 이성질체 분석 (Chiral Separation of Quinolone Antibacterial Agent by Capillary Electrophoresis)

  • 강대천;조승일;정두수;최규성;김용성
    • 대한화학회지
    • /
    • 제46권5호
    • /
    • pp.412-429
    • /
    • 2002
  • (+)(18crown6)-tetracarboxylic acid ($18C6H_4$)를 퀴놀린계 항생제인 gemifloxacin을 모세관 전기영동법으로 키랄 분리하였다. Body fluid에서 퀴놀린계 항생제인 gemifloxacin의 직접적인 분석은 빠른 분석 시간, 다성분 분석등의 여러 가지 장점을 가진다. 그러나 Body fluid내의 높은 농도의 나트륨 이온은 $18C6H_4$와 강한 전하 상호작용으로 인하여 gemifoxacin과 $18C6H_4$의 상호작용을 방해한다. 키랄 선택제와 나트륨 이온 사이의 상호 작용을 줄이기 위해 완충 용액에 킬레이트 리간드 EDTA를 첨가하였다. 시료 용액에 150mM의 나트륨 이온이 존재 할 때에도 분리 효율의 향상과 이동 시간의 감소를 관찰 할 수 이었다.

Enantioseparation and Determination of Sibutramine in Pharmaceutical Formulations by Capillary Electrophoresis

  • Zhu, Hongmei;Wu, Enqi;Chen, Jianbo;Men, Chuvan;Jang, Yu-Seon;Kang, Won-Ku;Choi, Jung-Kap;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1496-1500
    • /
    • 2010
  • Sibutramine enantiomers were separated successfully by capillary zone electrophoresis using substituted cyclodextrins as chiral selectors. The effects of cyclodextrin concentration, pH, voltage, buffer type, and electrolyte concentration on the migration time and resolution of enantiomers were examined. Separation of sibutramine enantiomers on an unmodified fused silica capillary (total length, 54 cm; effective length, 45 cm) was achieved using a mixed buffer of 20 mM phosphate/10 mM citrate containing either 5 mM methyl-${\beta}$-cyclodextrin (pH 4.3) or 5 mM carboxymethyl-${\beta}$-cyclodextrin (pH 6.5). Samples were injected with a pressure of 50 mbar for 5 s and were detected at a wavelength of 223 nm. The established method showed good precision and accuracy, with intra- and inter-day variations of less than 2.9 and 4.7%, respectively, and recoveries of 95.7 - 103.8%. The stability constants of (R)- and (S)-sibutramine demonstrated that the resolution of sibutramine enantiomers was attributable primarily to the difference in stability constants. When this optimized method was applied to the determination of sibutramine enantiomers in commercial drug formulations, it proved to be economical and convenient, affording sufficient accuracy, precision, and reproducibility as well as sensitivity and selectivity.

Chiral Purity Test of Bevantolol by Capillaryelectrophoresis and High Performance Liquid Chromatography

  • Long, Pham Hai;Trung, Tran Quoc;Oh, Joung-Won;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • 제29권9호
    • /
    • pp.808-813
    • /
    • 2006
  • Two methods for the chiral purity determination of bevantolol were developed, namely capillary electrophoresis (CE) using carboxymethyl-${\beta}$-cyclodextrin (CM-${\beta}$-CD) as a chiral selector and high-perfomance liquid chromatography (HPLC) using a chiral stationary phase. In the HPLC method, the separation of bevantolol enantiomers was performed on a Chiralpak AD-H column by isocratic elution with n-hexane-ethanol-diethylamine (10:90:0.1, v/v/v) as mobile phase. In the CE method, bevantolol enantiomers were separated on an uncoated fused silica capillary with 50 mM amonium phosphate dibasic adjusted to a pH 6.5 with phosphoric acid containing 15 mM CM-${\beta}$-CD as running buffer. Validation data such as linearity, recovery, detection limit, and precision of the two methods are presented. The detection limits of S-(-)-bevantolol were 0.1% and 0.05% for CE and HPLC method, respectively and R-(+)-bevantolol were 0.15% and 0.05% for CE and HPLC method, respectively. There was generally good agreement between the HPLC and CE results.