• Title/Summary/Keyword: Chiller capacity

Search Result 78, Processing Time 0.028 seconds

Rotor Dynamic Design of the Centrifugal Chiller Using Offset Bearing (Offset 베어링을 활용한 터보냉동기의 회전체동역학 설계)

  • Lee Chang-Joong;Park Yong Suk;Lee Joonkeun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.239-246
    • /
    • 2005
  • A rotor dynamic analysis is implemented to confirm the vibration stability of the high speed centrifugal chiller coupled with gear system. As the rotating speed of the centrifugal chiller under investigation is increased up to 17605rpm at the pinion rotating part, the bearing instability is getting higher and, furthermore, the rotor-bearing system might experience a few critical speed which lead to system failure due to the excessive vibration. In this study, considering the loading capacity and stability conditions, offset journal bearings are adopted for the pinion rotating system and general cylindrical bearings are used for motor part. From the modal analysis, the system is found to be stable as the critical damping ratio which shows the damping characteristics of the system are positive over all operating ranges, and in addition, the synchronous rotating frequency does not come across with any whirl natural frequency. From these results the authors confirm the vibration stability of the rotor-bearing system suggested in this study.

Design Effect of Different Components and Economic Evaluation of an Adsorption Chiller on the System Performance

  • Bidyut B. Saha;Shigeru Koyama;K.C. Amanul Alam;Lee, Jong-Boong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.17-22
    • /
    • 2002
  • A conventional silica gel/water adsorption chiller has been analyzed numerically. A novel non-dimensional mathematical model has been presented to analyze the design effect of different components of an adsorption chiller. The design parameters of this system are characterized by the number of transfer unit, NTU, of different components and the inert material alpha number, ${\alpha}$of different components of the systems. Results show that condenser NTU$\sub$a/ has the most influential effect on the system performance, which is fellowed by absorber NTU$\sub$e/. It is also seen that coefficient of performance (COP) and non-dimensional specific cooling capacity increases with the increase of NTU$\sub$a/ and NTU$\sub$e/, but decreases with the increase of inert material alpha number. A thermo-economic data of the adsorption chiller and some other heat pump systems those are in practical operation are also presented.

  • PDF

Rotor Dynamic Analysis of the High Speed Centrifugal Chiller (고속회전용 터보냉동기의 회전체 동역학 해석)

  • 이준근;박용석
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.193-198
    • /
    • 2003
  • A rotor dynamic analysis is implemented to confirm the vibration stability of the high speed centrifugal chiller coupled with gear system. As the rotating speed of the centrifugal chiller under investigated is increased up to 17,605 rpm at the pinion rotating part, the bearing instability is getting higher and, furthermore, the rotor-bearing system might experience a few critical speed which lead to system failure due to the excessive vibration. In this study, considering the loading capacity and stability conditions, offset journal bearings are adopted for the pinion rotating system and general cylindrical bearing are used for motor part. From the modal analysis, the system is found to be stable as the synchronous rotating frequency does not come across with any whirl natural frequency and, in addition, the critical damping ratio which shows the damping characteristics of the system are positive over the all operating ranges. From these results the authors confirm the vibration stability of the rotor-bearing system suggested in this study.

  • PDF

An Economic Analysis of Ice Thermal Storage and Absorption Chiller-Heater Systems (빙축열 시스템과 흡수식 냉온수기 공조 방식의 경제성 분석)

  • Lim, Hyun-Woo;Kim, Young-Il;Kim, Kang-San;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.218-223
    • /
    • 2009
  • Cost related to building equipment accounts for about 85% of the life cycle cost of buildings. Therefore proper selection of air-conditioning system is important for reducing the overall cost of buildings. In this study, large capacity ice thermal storage and absorption chiller-heater for air-conditioning a building with a floor area of $9,900\;m^2$ are compared economically. For easy input and analysis, an Ms Excel VBA program has been developed. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. Under the assumptions made in this study, overall cost of an absorption chiller-heater is less than that of an ice thermal storage, but this is not absolute and different outcome may result if different assumptions are made. This study is useful for those who are interested in choosing an economical air-conditioning system for large-size buildings with simple calculations.

  • PDF

Study on the Performance Characteristics of Micro Gas Turbine (MGT) Co-generation System (마이크로 가스터빈 열병합장치 성능특성 연구)

  • Hur, Kwang-Beom;Kim, Jae-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.964-970
    • /
    • 2006
  • Micro gas turbine(MGT) has received attention recently as small-scale distributed power sources. With characteristics such as their small size, lightweight, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of ' applications, including residential and small-scale industrial use. It is very easier to start-up and stop the MGT system which is the friendly environmental power system has just below the 9ppm NOx emmission and good quality of noise level. The exhaust heat emitted by the MGT is in the form of about $300^{\circ}C$ clean exhaust gas. The exhaust gas is suitable for absorption chiller/heater system. 1 has researched performance characteristics of the 60 kW class MGT-absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated.

The Characteristics of Energy Consumption with Operational Conditions for the Central Cooling System (냉방시스템의 운전조건에 따른 에너지 소비특성 연구)

  • Park, Gi-Tae;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.39-45
    • /
    • 2019
  • The operational conditions such as cooling tower water pump flow rate, cooling tower fan flow rate, and chiller capacity in heat source equipment, and supply air temperature and chilled water temperature in air conditioner are considered to study the effects on energy consumption for central cooling system by using TRNSYS program. As a result, the optimal values of supply air temperature and chilled water temperature for minimal total energy consumption are 12℃ and 8℃. And if maximum values of cooling tower water pump and fan flow rate is decreased from 100% to 40%, energy consumptions are increased 170MJ/day and 63.2MJ/day, respectively.

Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water (저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석)

  • Kim, Byong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

Experimental Study on Heat Transfer Performance of Plate Type Absorber with Variation of Solution Flow Rate (용액유량에 따른 플레이트 흡수기의 흡수 열전달 특성 실험)

  • Moon, C.G.;Bang, G.S.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1548-1553
    • /
    • 2003
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of development of high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is the most effective to improve the performance of absorber with the largest heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which can increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, horizontal tube bundle type. The size of plate absorbers were made for $0.4m{\times}0.6m$ and the design object of a refrigeration capacity was lRT. In this experiment, three kind plate absorbers which were flat plate, dimple plate and groove plate were used. The results were less than the design object values, that is, the refrigeration capacity was about $0.3{\sim}0.4RT$ and the overall heat transfer coefficient was $500{\sim}600kcal/m^2h^{\circ}C$ at the standard conditions.

  • PDF

Simulation of the Economizer Performance of a Screw Compressor Using R22 and R407C (R22와 R407C를 적용한 스크류 압축기의 이코노마이저 성능 시뮬레이션)

  • Kim, Yeong-Il;Park, Sang-Hyeon;Jang, Yeong-Su;Kim, Yong-Chan;Nam, Im-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.465-473
    • /
    • 2002
  • Screw compressor type chiller is widely used in refrigeration for capacity over 30 RT. To enhance the chiller performance, an economizer which increases the cooling capacity and COP can be adopted. In this study the performance of an economizer is studied by using a simulation program. Simulation results are compared with experiment data to verify the validation of a simulation program. Maximum economizer injection pressure is estimated and the performance of an economizer for various evaporation and condensation temperatures is calculated. From the results, the performance enhancement of an economizer by using R22 and R407C is compared.

Evaluation of Apartment Cooling System by Multi-Criteria Decision Making Analysis (다기준 의사결정 분석에 의한 공동주택의 냉방시스템 평가)

  • Kang, Byoung-Min;Cho, Jin-Hwan;Kim, Young-Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.580-586
    • /
    • 2011
  • In this study, 3 cooling systems of apartment which are air-cooled air conditioner with indoor unit, water-cooled air conditioner with indoor unit and small capacity absorption chiller-heater with FCU have been evaluated by Multi-Criteria Decision Making Analysis. Weights of 7 selected factors which are economics, space, billing, constructability, human comfort, visibility and reliability are determined by expert group of 30 system designers and 30 construction engineers. Final weights were derived for 101 and 166 $m^2$ apartments. Analysis shows that small capacity absorption chiller-heater with FCU is the most favorable system for apartment cooling system.