• 제목/요약/키워드: Chewing force

검색결과 56건 처리시간 0.025초

임플란트용 실링 어버트먼트의 개발 및 구조해석을 통한 성능분석 (Development of a Sealing-Type Abutment for Implant and the Performance Evaluation via Structural Analysis)

  • 김정민;홍대선
    • 한국정밀공학회지
    • /
    • 제33권9호
    • /
    • pp.769-775
    • /
    • 2016
  • Currently, dental implants are widely used as artificial teeth due to their good chewing performance and long life cycle. Generally, a dental implant consists of an abutment as the upper part and a fixture as the lower part. When chewing forces are repeatedly applied to a dental implant, a gap is often generated at the interfacial surface between the abutment and the fixture, and it results in some deterioration such as loosening of the fastening screw, dental retraction and fixture fracture. To enhance the sealing performance for coping with such problems, this study proposes a new sealing-type abutment having a number of grooves along the conical surface circumference, and it carries out finite element analysis in consideration of the external chewing force and pretension between the abutment and the fixture. The result shows that the proposed sealing-type abutment shows an enhanced sealing performance in terms of the contact pressure in comparison with a conventional abutment.

Functional evaluation of orthopedic and orthodontic treatment in a patient with unilateral posterior crossbite and facial asymmetry

  • Kwak, Yoon-Young;Jang, Insan;Choi, Dong-Soon;Cha, Bong-Kuen
    • 대한치과교정학회지
    • /
    • 제44권3호
    • /
    • pp.143-153
    • /
    • 2014
  • An 8-years old boy with facial asymmetry and unilateral posterior crossbite on the left side received orthopedic and orthodontic treatment. During the first phase of treatment, the narrow maxillary arch was expanded using an acrylic plate. Then, the acrylic plate was used as a bite block with occlusal indentations from the construction bite that was obtained with the incisors in a coincident dental midline. After the position of the mandible was stabilized, the second phase of orthodontic treatment was initiated using fixed appliances for detailing of the occlusion. Skeletal symmetry, ideal occlusion, and coincident dental midlines were thus achieved. Functionally, occlusal force balance and masticatory muscle activity were improved, and the chewing patterns were normalized.

20대 일부 성인의 교합력 관련 요인 (Influencing factors on bite force of adults in twenties)

  • 이미라;정수진
    • 한국치위생학회지
    • /
    • 제14권3호
    • /
    • pp.303-310
    • /
    • 2014
  • Objectives : The purpose of the study is to investigate the effects of bite force by gender and physical features. Methods : A self-reported questionnaire was filled out by 212 college students in Chungnam province from October to December, 2013. The questionnaire consisted of oral health condition. The bite force of the first molar teeth was measured. Results : Males showed the greater bite force than females(p<0.001). Those who had temporomandibular joint(TMJ) disorder suffered from mouth opening difficulty and weaker bite force than those who had not(p<0.05). Those who had malocclusion showed weaker bite force (p<0.01). Those who had a habit of chewing gums tended to have greater bite force than those who had not(p<0.05). The bite force was correlated with height(r=0.309), weight(r=0.345), and BMI(r=0.249)(p<0.01). Conclusions : Males showed greater bite force than females. The temporomandibular joint (TMJ) disorder, subjective malocclusion, and eating habit also affected the bite force.

교모면적과 교합접촉양태 간의 관계에 대한 연구 (A Study on the Relation between Occlusal Wear Area and Occlusal Contact Patterns)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제19권2호
    • /
    • pp.153-168
    • /
    • 1994
  • The aim of the present study was to investigate a relation between occlusal wear area and occlusal contact patterns. For the purpose, occlusal wear area were measured in 58 dental students and in 129 patients with temporomandibular disorders(TMDs) from dental casts. Teeth used in this study were from canine to second molar on both sides in upper arch, totally ten. Occlusal wear area on casts was marked by pencil and photocopies, and then, the area was measured with planimeter. Occlusal relation was clinically examined with regard to Angle's classification, chewing side preference, lateral guidance pattern and bruxing and/or clenching habit. T-Scan, electronic occlusal contact analyzer, was used to record occlusal contact number, contact force, contact time and occlusal balance that is TLR(total left-right statistics) during tooth contact. All measurement were repeated 3 times and the average value was used for data processing. The obtained results were as follows : 1. Mean value of occlusal wear area did not differ significantly between dental students and patients. 2. There ws not significant difference in wear area between chewing side and non-chewing side in both groups. 3. Occlusal wear area was significantly increased with age in both groups. 4. Three subgroups divided by Angle's classification did not show any difference in occlusal wear area among them, but three subgroups divided by lateral guidance pattern showed slightly significant difference between canine guide subgroup and group function subgroup in patients. Occlusal wear ares\a in group function subgroup wear larger than canine guide subgroup. 5. Mean value of wear area in patients with bruxing and/or clenching habit did not differ from those in patients without such habit. 6. Correlationship among items related to occlusal contact pattern were highly consistent and significant in dental students and only one item significantly correlated with occlusal wear area was tooth contact time.

  • PDF

츄잉검의 텍스쳐 : 물성간(物性間)의 상관관계와 기호도(嗜好度)의 여측(予測) (Texture of Chewing Gum: Correlation among Rheological Parameters and Prediction of Preference)

  • 유명식;이윤형;변유량
    • 한국식품과학회지
    • /
    • 제16권3호
    • /
    • pp.309-313
    • /
    • 1984
  • 츄잉검의 기계적(機械的) 물성(物性)과 관능적(官能的) 물성(物性) 및 기호성(嗜好性)과의 상관관계로부터 츄잉검의 텍스쳐를 잘 표현하는 물성(物性)을 찾아내었고 대표적(代表的)인 기계적(機械的) 물성(物性)으로부터 기호성(嗜好性)을 여측(予測)하는 식(式)과 ideal texture profile을 제시하였다. 츄잉검의 텍스쳐를 가장 잘 표현(表現)하는 대표적(代表的)인 물성(物性)은 초기(初期)의 관능적(官能約) stiffness와 기계적 puncture work, 중기(中期)의 관능적(官能的) firmness와 기계적(機械的) hardness, 후기(後期)의 관능적(官能的) firmness와 기계적(機械的) hardness, slope 및 관능적(官能的) lift 와 기계적(機械約) springiness이었다. 대표적(代表的)인 기계적(機械的) 물성(物性)으로 소비자(消費者)의 기호성(嗜好性)을 다음과 같이 여측(予測)하였다. 소비자(消費者)의 종합점수(綜合点數) = $7.336-0.369{\time}10^{-5}(Puncture work)+0.075{\time}10^{-5}(Intermediate\;hardness)+0.382{\time}10^{-5}(Final hardness)-0.806{\time}10^{-5}(Slope)-5.168(Springiness)$. 시대적(代表的)인 기계적(機械約) 물성(物性)으로 ideal texture profile을 작도하였다.

  • PDF

유전자알고리즘을 이용한 임플란트용 실링어버트먼트의 홈 깊이 최적화에 관한 연구 (Optimization of the Groove Depth of a Sealing-type Abutment for Implant Using a Genetic Algorithm)

  • 이현열;홍대선
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.24-30
    • /
    • 2018
  • Dental implants are currently widely used as artificial teeth due to their good chewing performance and long life cycle. A dental implant consists of an abutment as the upper part and a fixture as the lower part. When chewing forces are repeatedly applied to a dental implant, gap at the interface surface between the abutment and the fixture is often occurred, and results in some deteriorations such as loosening of fastening screw, dental retraction and fixture fracture. To cope with such problems, a sealing-type abutment having a number of grooves along the conical-surface circumference was previously developed, and shows better sealing performance than the conventional one. This study carries out optimization of the groove shape by genetic algorithm(GA) as well as structural analysis in consideration of external chewing force and pretension between the abutment and the fixture. The overall optimization system consists of two subsystems; the one is the genetic algorithm with MATLAB, and the other is the structural analysis with ANSYS. Two subsystems transmit and receive the relevant data with each other throughout the optimization processes. The optimization result is then compared with that of the conventional one with respect to the contact pressure and the maximum stress. The result shows that the optimized model gives better sealing performance than the conventional sealing abutment.

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • 대한소아치과학회지
    • /
    • 제51권1호
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

교합력 측정에 영향을 주는 요인 (Factors that affect the bite force measurement)

  • 임지호;이원섭;김명주;임영준;권호범
    • 구강회복응용과학지
    • /
    • 제32권1호
    • /
    • pp.1-7
    • /
    • 2016
  • 저작은 음식을 잘게 부수어 소화작용이 원활하게 진행될 수 있도록 돕는 행위이다. 이러한 저작계는 상하악골, 악관절, 인대, 치아 및 근육으로 구성된다. 교합력은 이러한 저작계를 평가하는 한 가지 수단이다. 교합력은 얼굴형태, 나이, 성별, 치주질환, 측두하악장애, 치아 상태 등에 의해 영향을 받는다. 최대교합력은 방형(square form)의 얼굴이 높으며 일반적으로 남자가 여성보다 높다. 또한 20세정도까지 증가하며 그 이후부터 40 - 50세까지 거의 일정하게 유지되다가 감소하는 경향을 보인다. 치주질환이 있을 경우 교합력 감소에 영향을 주며 측두하악장애의 경우 교합력의 영향에 논란이 있다. 치아의 상태가 최대교합력에 영향을 미치는 중요한 인자로 생각된다.

한국전통 김치의 다양화 및 세계화를 위한 스페인인의 기호도 조사연구 (A Survey of the Preference for Korean Kimchi by Spanish Natives)

  • 이명기;장대자;양혜정;정자경
    • 한국식품조리과학회지
    • /
    • 제24권6호
    • /
    • pp.871-875
    • /
    • 2008
  • This study was conducted to develop methods of promoting traditional Korean Kimchi globally. To accomplish this, 99 Spanish natives were surveyed for their sensory evaluation and awareness of Kimchi. The results revealed that a relatively high number (46.9%) of the respondents had eaten Korean Kimchi. After eating the Kimchi, women tended to provide a slightly higher overall acceptability than men. Furthermore, when the overall sensory evaluation was conducted, the characteristics of Kimchi that were most recognized were its red color, spicy smell and hot taste. In addition, 93.9% of the respondents said that Korean Kimchi was a suitable food based on its spicy flavor>chewing force>appearance>red color>fermented smell. However, 6.1 percent of the subjects responded that they did not find Kimchi appetizing due to its hot taste>fermented smell>chewing force. Interestingly, the hot taste was a common selection for the reason that individuals liked or disliked Kimchi. When ranked among traditional Spanish foods, Kimchi was reportedly similar to cooked cabbage, cooked bell peppers, cooked red peppers and Moheu ppikan, pickles, Spanish lettuce, chiseutora and oil pickled cheese, or to various vegetables pickled in vinegar. Taken together, the results of this study should facilitate the globalization of Kimchi. In addition, the findings of this study provide fundamental data that should assist in the development of a local style of Kimchi for Spain.