• Title/Summary/Keyword: Chest x-ray

Search Result 1,074, Processing Time 0.025 seconds

A Case of Cryptococcosis involving Lung and CNS without Underlying Disease (폐와 중추신경계를 침범한 효모균증(Cryptococcosis) 1예)

  • Lee, Min-Su;Park, Sang-Seon;Koh, Young-Il;Jang, An-Soo;Lim, Sung-Chul;Yang, Ju-Yeoul;Park, Hyung-Kwan;Na, Hyun-Joo;Kim, Young-Chul;Choi, In-Seon;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.618-623
    • /
    • 1995
  • Cryptococcosis is a systemic mycosis that most often involves the lungs and central nervous system and, less frequently, the skin, skeletal system, and prostate gland. Cryptococcus neoformans, the causative organism, is a yeastlike round or oval fungus, 4 to $6{\mu}m$ in diameter, which is surrounded by a polysaccharide capsule and reproduces by budding and found in soil and other environmental areas, especially those contaminated by pigeon droppings. Humans and animals acquire infection after inhalation of aerosolized spores. Condition or factors that predispose to cryptococcosis include corticosteroid therapy, lymphoreticular malignancies, HIV infection, and sarcoidosis etc. We discribed a case of cryptococcosis involving lung and CNS coincidently without specific underlying disease and the literature on subject were reviewed. A fifty-six year-old previously healthy female presented with headache of 3 months of duration. She had no history suggesting immunologic suppression and we could not find any abnormal laboratory findings including blood sugar, serum immunoglobulin and complement level, HIV antibody, and T cell subsets. Chest roentgenogram and CT scan showed a solitary soft tissue mass in LUL with distal pneumonitis. Brain MRI showed granulomatous lesion in cerebellum and parasagittal cortex of right frontal lobe. The diagnosis was made by bronchoscopic brushing cytology, transthoracic fine needle aspiration, and sputum KOH mount and culture. She was treated 6 weeks course of Amphotericin B and switched to oral fluconazole therapy for 3 months. Her symptoms and X-ray findings were improved gradually and she is now under regular clinical follow up.

  • PDF

Interstitial Lung Disease Associated with Polymyositis: Response to Cyclophosphamide and Prednisolone Combination Treatment (Cyclophosphamide와 Prednisolone 병합요법에 치료반응을 보인 다발성근염에 동반된 간질성폐질환 1예)

  • Moon, Jong-Ho;Park, Jun-Young;Lee, Sang-Moo;Kim, Hyeon-Tae;Uh, Soo-Taek;Chung, Yeon-Tae;Kim, Yong-Hoon;Park, Choon-Sik;Lee, Kyung-Soo;Kang, Dae-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.197-202
    • /
    • 1993
  • Polymyositis (PM) is a inflammatory connective tissue disease involving predominantly skeletal muscles, characterized by symmetrical, proximal muscle weakness, inflammation, and frequently, degeneration. Interstitial lung disease in association with PM occurs in 5~10% of cases and carries an especially grave prognosis. Although the cause of lung involvement in PM is not known, the underlying pathologic process in the lung is an immune mediated inflammation of alveolar structures, alveolitis. It is of interest, therefore, that cyclophosphamide, an immune modulating agent, has been reported to be effective in the treatment of PM. We report a case of corticosteroid resistant PM associated with interstitial lung disease, successfully treated with cyclophosphamide. A 37-year-old female was presented with 8 months duration of cough, exertional dyspnea, and muscle weakness. She had typical symptoms, physical findings, and elevated muscle enzyme levels in serum with characteristic findings of muscle biopsy. She also had typical interstitial lung disease pattern on chest X-ray and high resolution CT with restrictive pattern on pulmonary function test. The findings of transbronchial lung biopsy was compatible with interstitial lung disease. She failed to respond to corticosteroid initially. Subsequently steroids and cyclophosphamide were given with excellent clinical improvement.

  • PDF

Mediastinal Lymphangioma in Adults : Three Case Reports (성인에서 발생한 종격동 림프관종 3례)

  • Kim, Kyung Chan;Koh, Won-Jung;Kwon, O Jung;Lee, Byoung-Hoon;Hwang, Jung Hye;Kang, Eun Hae;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Han, Joungho;Ko, Young Hyeh;Kim, Jhingook;Kim, Tae Sung;Lee, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.303-310
    • /
    • 2003
  • Background : Lymphangioma of the mediastinum is an uncommon benign tumor of lymphatic origin that is most often seen in children, is very rare in adults and is frequently discovered incidentally on chest x-ray exams. While radiology (CT and MRI) may suggest the diagnosis and allow an assessment of the operative difficulties, the histology of the surgical specimen is required for precise diagnosis. Complete resection is the only treatment; however, in some patients resection was incomplete because of the infiltrating character of these tumors, leading to recurrence. We report three cases of mediastinal lymphangioma with a review of the literature.

Coexistence of Hodgkin's Lymphoma and Tuberculosis in the Same Axillary Lymph Nodes (결핵과 호지킨 림프종이 액와부 림프절에 공존하였던 1예)

  • Ban, Woo-Ho;Kang, Hyeon-Hui;Baeg, Myong-Ki;Kim, Jae-Gyung;Kim, Hyun-Jin;Baek, In-Woon;Kim, Eun-Oh;Ko, Sun-Hye;Lee, Sang-Haak;Moon, Hwa-Sik;Min, Ki-Ouk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.4
    • /
    • pp.342-346
    • /
    • 2011
  • Herein we report the case of a 71-year-old woman who complained of fatigue and enlarged right axillary lymph nodes for 18 months. At her first visit, her chest X-ray showed diffuse nodular opacities in both lung fields. Initial excisional biopsy of the axillary lymph nodes showed granulomatous lesions and acid fast bacilli were seen on Ziehl-Neelsen staining. However, even after 15 months of anti-tuberculosis (TB) medication, her right axillary lymph nodes were enlarged. We re-performed an excisional biopsy of the nodes, which showed Hodgkin's lymphoma (HL). A retrograde review of the biopsy before anti-tuberculous medication, revealed HL coexisting with TB. HL and TB cause difficulties in differential diagnosis due to similarities in clinical course, imaging procedures and histopathological analysis of the involved tissue. Therefore, it is important to consider the possibility of concurrent HL and TB when patients who undergo treatment for TB or chemotherapy for lymphoma complain of persistent systemic symptoms or enlarged lymph nodes.

The Prevalence, Health behaviors, and Control of Hypertension in Rural Areas in Korea (보건진료소 관할 농촌지역 주민의 고혈압 유병률, 건강행태 및 고혈압 관리 양상)

  • Chungbuk CHP research team, Chungbuk CHP research team;Jeon, Mi-Yang
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.3
    • /
    • pp.507-519
    • /
    • 2003
  • Purpose: The purpose of this study was to identify the prevalence, health behaviors, and control of hypertension in rural areas in Korea. Method: A total of 927 subjects above age 20 were selected from the areas which fell under the jurisdiction of the 24 Community Health Center located in Chungcheongbuk-do. The employees in the Community Health Center visited and interviewed patients. Data were collected using a questionnaire from July to October 2002. Result: The result showed that women had higher hypertension prevalence rates than men and the increment of its rate leveled up according to age. The hypertension prevalence rate was significantly high when the monthly income was less than 1 million won, their type of the Medical Insurance was the Guardian, they were only able to read Korean characters, and they were bereaved of spouses. In the Health behavior related to hypertension, the hypertension group showed a significantly lower level than the non- hypertension group in terms of drinking rate, smoking rate, intake of salt and intake of meat. There was no significant difference in the exercise rate and coffee intake rate between these groups. In the degree of the obesity the hypertension group was significantly higher than the non-hypertension group. The factors related to hypertension were that the duration for the incidence of hypertension was 12 to 60 months and took up 41.2%. The places where the medical check-ups occurred were the Community Health Center at 46.6%, the medical institution was mostly hospitals recording 46.5%. There were 66.1% of the targets who knew well about their blood pressure and there were 64.7% people who received education about it. As for the education place, the rate of Community Health Center was mostly high and it stood at 77.0%. In the aspect of the management of hypertension, the targets who took medicine on a regular basis were up to 76.1% and the targets who measured blood pressure once a month happened to be about 46.1 %. The targets who always recorded their blood pressure were 3.8%, chest X-ray as a related examination of hypertension reached 32.6%, electrocardiogram examination was 36.2%, cholesterol and serum lipid examination took up 33.6%, and the eye ground examination took 7.3%, which showed the lowest level of all.

  • PDF

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor (자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석)

  • Park, Sung-Tae;Yoon, Chong-Hyun;Park, Kwang-Bo;Auh, Yong-Ho;Lee, Hyoung-Jin;In, Kyung-Hwan;Kim, Keon-Chung
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

Development of Activation Program through the Evaluation of University Health Center - on the women's university in Seoul - (대학보건소의 현황과 활성화 방안 연구 - 서울시 여자대학을 중심으로 -)

  • Kwon, Su-Kyung
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.2 no.1
    • /
    • pp.41-52
    • /
    • 2001
  • The purpose of this research is to plan the activation of university health business through the appraisal of the function and role of university health centers. To be more specific: Firstly, analyze the facility, personnel, health service of the health centers, Secondly, appraise the role and function of the health centers, and Thirdly, consider the activation plans of health centers. The research method taken was the study of surveys conducted and written research materials on 5 women's universities in Seoul. These materials where descriptively analyzed by converting the surveys, facility and usage of health center and current personnel status in to percentage. The major results of the research are as follows: Unlike as stated in each university's additional clause on the number of personnel were working. This lack of specialized personnel resulted into lack of specialized and various services. Medicine for external application were stocked well whereas only simple medicine for internal application were on shelf and were issued only with a doctor's prescription. Universities with a full-time doctor had various available equipments. One university conducting dental treatment was equipped with indirect chest camera, dental X-ray, unit, chair(dental treatment chair) and even supersonic, electrocardiogram were available. In the case of D women's university, the number of beds compared to the number of students was lower than that of the other 3 universities, to the total size of the university was smaller than that of the other 3 universities. Among health prevention and care matters, health consultation was the only matter practised by all universities. Uniquely, there was one university that hosted epidemic prevention business. There are various tests given by each university, with each showing many differences, but some universities did not even conduct these tests. Vaccinations were usually being conducted through commission. All universities provided basic treatment, therefore matters concerning treatment at health centers were being conducted well. Concerning the management of equipment and documents, all the matters were being conducted except one university where instead of a student medical record, they were using a daily record. Because these were women's universities, most of the educations were on women's health. The subjects of these educations included: sex, contraception, prevention and control of tuberculosis, obesity, mouth hygiene, alcohol, geriatric disease, mental health and first-aid. The rate of health center usage is growing. Being women's universities, the service and treatment practised were mostly concerning sex education.

  • PDF

CT Findings and Accuracy of Preoperative Pathologic Diagnosis in Bronchial Carcinoid According to Subtype (기관지 유암종의 아형에 따른 CT 소견과 수술전 병리학적 진단의 정확성)

  • 임준석;홍용국;정경영;최규옥
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.380-387
    • /
    • 1998
  • We evaluated CT findings of bronchial carcinoid and accuracy of preoperative pathological diagnosis according to two subtypes. The subjects were 10 cases(typical;5, atypical;5), confirmed by surgery and tissue pathology. Sputum cytology(n=10), percutaneous aspiration(n=1) and bronchoscopic biopsy (n=8) were performed, preoperatively. The CT findings were analysed according to two subtypes. Typical carcinoid shows central location in all, and bronchial lumens just proximal to tumor were widened in two, whereas atypical carcinoid presented as peripheral leison in two. Among central atypical carcinoid, two cases showed flat meniscus appearance of lumen. Remaining one showed diffuse wall thickening. Intratumoral low density by necrosis was noted in one. Both subtypes show contrast enhancement. For preoperative diagnosis, sputum cytology & percutaneous aspiration were not conclusive at all. As for bronchoscopic biopsy, only 3 cases were accurately diagnosed as typical carcinoid. Typical carcinoid presented as endobronchial mass in all, whereas atypical carcinoid presented in various appearance. In all atypical & some typical carcinoid were misdiagnosed as primary lung cancer, preoperatively. However, in typical carcinoid, conservative surgery was possible. In conclusion, if there is discrepancy between CT findings & preoperative pathological diagnosis, full understanding of CT findings of bronchial carcinoid is imperative to choose appropriate surgical modality.

  • PDF

A Analysis of Effectiveness of Aluminium Filter in the added Compound Filtration by Detective Quantum Efficiency and Image Quality Evaluation (복합부가여과에서 알루미늄 여과판 사용 시 양자검출효율과 화질평가를 통한 효율성 분석)

  • Kim, Sang-Hyeon;Kim, Yun-Min;Kwon, Kyoung-Tae;Ma, Sang-Chull;Han, Dong-Gyoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.362-373
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation from high atomic number material by DQE and image evaluation. 1mm Al was applied to each 0.1, 0.2, 0.3 mm copper and befere and after use were evaluated. Beam quality and DQE were tested by IEC regulations and image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by 7 items for resolution and contrast from chest x-ray criteria of national cancer checkup. MTF 10 and 50% were the same by 4.6, 2.54 cycle/mm and NPS, DQE, PSNR MAE, MSE, CNR, SNR and qualitative analysis were all the same or slightly better when Al was not used. PSNR is over 30dB and all significant and at the qualitative analysis, the p-value of t-test was over 0.05. The DQE and image quality evaluation have little difference between before and after use of Al filter and it is effective to use the Al filter for the reduction of skin dose by removal of characteristic radiation.