• 제목/요약/키워드: Chest projection

검색결과 47건 처리시간 0.023초

저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량 (Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography)

  • 문태준;김기정;이혜남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.261-267
    • /
    • 2017
  • 저 선량 흉부 전산화단층촬영(low dose computed tomography; LDCT)검사 시 기존의 검사방법인 필터보정역투영법인 FBP(filted back projection)와 적응식 통계적 반복 재구성법인 ASIR(adaptive statistical iterative reconstruction)의 적용 및 관전압 변화에 따른 영상의 화질과 피폭선량을 비교 평가해 보고자 하였다. 흉부 phantom을 이용하여 재구성방법에 따라 FBP와 ASIR적용(10%, 20%)을 하였고, 관전압(100kVp, 120kVp)에 변화를 주어 실험을 하였다. 화질평가를 위해 back-ground noise와 signal-noise ratio(SNR), contrast-noise ratio(CNR)를 구하였으며, 선량평가를 위해 CTDIvol과 DLP를 구하였다. 화질평가에 있어 kVp에 따른 ascending aorta(AA) SNR과 inpraspinatus muscle(IM) SNR은 AA SNR과 IM SNR은 유의한 차이가 있었다(p < 0.05). 선량평가에 있어 CTDIvol과 DLP는 유의한 차이가 있었으며(p < 0.05), CTDIvol은 120 kVp, FBP가 2.6 mGy, 120 kVp, 10%-ASIR가 2.38 mGy, 120kVp, 20%-ASIR가 2.17 mGy로 0.43 mGy 감소하였고, 100 kVp, FBP가 1.61 mGy, 100 kVp, 10%-ASIR가 1.48 mGy, 100 kVp, 20%-ASIR가 1.34 mGy로 0.27 mGy 감소하였다. 또한 DLP에서는 120 kVp, FBP가 $103.21mGy{\cdot}cm$, 120 kVp, 10%-ASIR가 $94.57mGy{\cdot}cm$, 120 kVp, 20%-ASIR가 $85.94mGy{\cdot}cm$$17.27mGy{\cdot}cm$(16.7%) 감소하였고, 100 kVp, FBP가 $63.87mGy{\cdot}cm$, 100 kVp, 10%-ASIR가 $58.54mGy{\cdot}cm$, 100 kVp, 20%-ASIR가 $53.25mGy{\cdot}cm$$10.62mGy{\cdot}cm$(16.7%)로 감소하였다. 재구성방법에 따른 FBP와 ASIR 10%, 20%에서는 화질의 변화 없이 선량을 줄일 수 있어 흉부 low dose CT검사 시 ASIR 20%적용하여 검사하는 것이 좋으며, 관전압 변화에 따른 120 kVp와 100 kVp에서는 선량은 크게 줄어들었지만, noise가 증가하여 화질이 떨어지는 것으로 나타났다.

PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구 (The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT)

  • 도용호;송호준;이형진;이홍재;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Siemens사의 CT 선량 감소 소프트웨어인 IRIS의 적용을 통하여 CT 선량 감소 시 노이즈 감소 효과와 해상력의 보존 그리고 ACCT에 IRIS 각 kernel의 적용 시 SUV 변화를 확인하는데 목적을 두었다. Biograph mCT 40 slice 스캐너를 이용하여 AAPM CT performance phantom, Anthropomorphic chest phantom을 관전압 120 kVp로 고정하고 100-10 mAs까지 15%감소하여 스캔 후 FBP, IRIS 각 kernel을 적용하여 재구성 하여 영상의 노이즈, 해상력, 영상 평가를 시행하였다. NEMA IEC body phantom을 이용하여 55.5 MBq를 background에 주입하고 열소와 배후 방사의 비를 8:1이 되도록 모형을 제작하였다. 120 kVp, 50 mAs 조건으로 1분, 2분, 3분, 4분 스캔하여 영상을 획득한 후 ACCT에 IRIS 각 kernel을 적용하여 기존 FBP 방식을 적용한 SUV와의 평가를 시행하였다. IRIS의 적용 시 기존 FBP 방식에 비하여 45% 선량을 감소하였음에도 불구하고 해상력 저하 없는 노이즈 감소 효과가 확인 되었으며 SUV 평가 실험에서 IRIS의 I70f kernel을 제외하고는 기존 FBP 방식을 통하여 획득된 SUV와 유의한 차이가 나타나지 않았다. 본 연구를 통하여 IRIS 적용 시 기존 FBP 방식에 비하여 CT 피폭선량 감소와 해상력 저하 없는 노이즈 감소 효과를 입증하였으며 IRIS kernel의 적절한 적용을 통하여 PET/CT 검사 시 환자 피폭선량 감소는 물론 FBP 방식에 비하여 우수한 영상의 획득이 가능할 것이라 사료된다.

  • PDF

견갑골 측방향 촬영에서 견갑골 정측면상을 얻기 위한 환자의 회전각도에 관한 연구 (The Study of patient rotation angle to get the scapular true lateral image in scapular lateral projection)

  • 박기봉;강인희;최남길;장영일;전주섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권3호
    • /
    • pp.203-209
    • /
    • 2005
  • 목 적 : 견갑골의 골절 유 무와 외상에 의한 탈구를 진단하는데 있어 견갑골의 정측면상의 영상을 얻는 것이 매우 중요하다. 본 연구의 목적은 견갑골 측방향 촬영시 한국인 성인을 대상으로 견갑골의 정측면상을 얻는데 가장 적합한 회전 각도를 알아보는데 있다. 대상 및 방법 : 견갑골의 촬영을 위해 내원한 환자 30명(여 8명)을 대상으로 하였고 이들의 평균연령은 35.4세(15세부터 66세)였다. 수동각도기의 거상각도를 $32^{\circ}$, $37^{\circ}$, $42^{\circ}$로 하여 전 후방향 촬영하였다. 영상의 평가는 전문가 5명이 내측연과 외측연의 완전겹침이 있는 영상은 4점, 내측연과 외측연이 불완전 겹침이 있는 영상은 3점, 견갑골체 내측연과 외측연이 겹침이 없는 영상은 2점, 내측연과 외측연이 사방향으로 나타난 영상은 1점으로 4단계로 나누어 blind test를 하여 평가하였다. 결 과 : 평가한 각도별 평균점수는 $32^{\circ}$$1.53{\pm}0.39$점, $37^{\circ}$$3.83{\pm}0.15$점, $42^{\circ}$$2.17{\pm}0.43$ 점으로 나타났다. 또한 가슴둘레가 100 cm이상인 군과 100 cm이하인 군 간에는 유의한 차이가(p<0.05) 없었고, 남자와 여자 간에도 역시 유의한 차이가 없는 것으로 나타났다. 결론 및 고찰 : 지금까지 견갑골 정측면상을 얻는데 적합한 환자의 회전각도에 관한 연구가 없었으나, 본 연구를 통해 검사측을 $37^{\circ}$회전하며 검사측 상완골을 반대쪽으로 들며 촬영하는 것이 한국인 성인에서 견갑골의 정측면상을 얻는데 가장 적합하다는 결론을 얻었다. 본 연구 결과는 향후 견갑골의 측방향 촬영을 하는데 유용할 것으로 사료된다.

  • PDF

병원 내원한 환자 견갑골(scapula) 진단을 위한 연구 (The shoulder diagnosis Scapula study of patients who visited the hospital)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제4권2호
    • /
    • pp.13-20
    • /
    • 2010
  • 견갑골의 골절 유 무와 외상에 의한 탈구를 진단하는데 있어 견갑골의 정측면상의 영상을 얻는 것이 매우 중요하다. 본 연구의 목적은 견갑골 측방향 촬영시 한국인 성인을 대상으로 견갑골의 정측면상을 얻는데 가장 적합한 회전 각도를 알아보는데 있다. 견갑골의 촬영을 위해 내원한 환자 20명(여 8명)을 대상으로 하였고 이들의 평균연령은 35.4세(15세부터 66세)였다. 수동각도기의 거상각도를 $30^{\circ}$, $40^{\circ}$, $45^{\circ}$로 하여 전 후방향 촬영하였다. 영상의 평가는 전문가 5명이 내측연과 외측연의 완전겹침이 있는 영상은 4점, 내측연과 외측연이 불완전 겹침이 있는 영상은 3점, 견갑골체 내측연과 외측연이 겹침이 없는 영상은 2점, 내측연과 외측연이 사방향으로 나타난 영상은 1점으로 4단계로 나누어 blind test를 하여 평가하였다. 평가한 각도별 평균점수는 $30^{\circ}$$1.53{\pm}0.39$점, $40^{\circ}$$3.83{\pm}0.15$점, $45^{\circ}$$2.17{\pm}0.43$ 점으로 나타났다. 도한 가슴둘레가 100cm이상인 군과 100cm이하인 군 간에는 유의한 차이가(p<0. 05) 없었고, 남자와 여자 간에도 역시 유의한 차이가 없는 것으로 나타났다. 지금까지 견갑골 정측면상을 얻는데 적합한 환자의 회전각도에 관한 연구가 없었으나, 본 연구를 통해 검사측을 $40^{\circ}$ 회전하며 검사측 상완골을 반대쪽으로 들며 촬영하는 것이 한국인 성인에서 견갑골의 정측면상을 얻는데 가장 적합하다는 결론을 얻었다. 본 연구 결과는 향후 견갑골의 측방향 촬영을 하는데 유용할 것으로 사료된다.

Impact of Model-Based Iterative Reconstruction on the Correlation between Computed Tomography Quantification of a Low Lung Attenuation Area and Airway Measurements and Pulmonary Function Test Results in Normal Subjects

  • Kim, Da Jung;Kim, Cherry;Shin, Chol;Lee, Seung Ku;Ko, Chang Sub;Lee, Ki Yeol
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1187-1195
    • /
    • 2018
  • Objective: To compare correlations between pulmonary function test (PFT) results and different reconstruction algorithms and to suggest the optimal reconstruction protocol for computed tomography (CT) quantification of low lung attenuation areas and airways in healthy individuals. Materials and Methods: A total of 259 subjects with normal PFT and chest CT results were included. CT scans were reconstructed using filtered back projection, hybrid-iterative reconstruction, and model-based IR (MIR). For quantitative analysis, the emphysema index (EI) and wall area percentage (WA%) were determined. Subgroup analysis according to smoking history was also performed. Results: The EIs of all the reconstruction algorithms correlated significantly with the forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) (all p < 0.001). The EI of MIR showed the strongest correlation with FEV1/FVC (r = -0.437). WA% showed a significant correlation with FEV1 in all the reconstruction algorithms (all p < 0.05) correlated significantly with FEV1/FVC for MIR only (p < 0.001). The WA% of MIR showed the strongest correlations with FEV1 (r = -0.205) and FEV1/FVC (r = -0.250). In subgroup analysis, the EI of MIR had the strongest correlation with PFT in both eversmoker and never-smoker subgroups, although there was no significant difference in the EI between the reconstruction algorithms. WA% of MIR showed a significantly thinner airway thickness than the other algorithms ($49.7{\pm}7.6$ in ever-smokers and $49.5{\pm}7.5$ in never-smokers, all p < 0.001), and also showed the strongest correlation with PFT in both ever-smoker and never-smoker subgroups. Conclusion: CT quantification of low lung attenuation areas and airways by means of MIR showed the strongest correlation with PFT results among the algorithms used, in normal subjects.

Feasibility of Single-Shot Whole Thoracic Time-Resolved MR Angiography to Evaluate Patients with Multiple Pulmonary Arteriovenous Malformations

  • Jihoon Hong;Sang Yub Lee;Jae-Kwang Lim;Jongmin Lee;Jongmin Park;Jung Guen Cha;Hui Joong Lee;Donghyeon Kim
    • Korean Journal of Radiology
    • /
    • 제23권8호
    • /
    • pp.794-802
    • /
    • 2022
  • Objective: To evaluate the feasibility of single-shot whole thoracic time-resolved MR angiography (TR-MRA) to identify the feeding arteries of pulmonary arteriovenous malformations (PAVMs) and reperfusion of the lesion after embolization in patients with multiple PAVMs. Materials and Methods: Nine patients (8 females and 1 male; age range, 23-65 years) with a total of 62 PAVMs who underwent percutaneous embolization for multiple PAVMs and were subsequently followed up using TR-MRA and CT obtained within 6 months from each other were retrospectively reviewed. All imaging analyses were performed by two independent readers blinded to clinical information. The visibility of the feeding arteries on maximum intensity projection (MIP) reconstruction and multiplanar reconstruction (MPR) TR-MRA images was evaluated by comparing them to CT as a reference. The accuracy of TR-MRA for diagnosing reperfusion of the PAVM after embolization was assessed in a subgroup with angiographic confirmation. The reliability between the readers in interpreting the TR-MRA results was analyzed using kappa (κ) statistics. Results: Feeding arteries were visible on the original MIP images of TR-MRA in 82.3% (51/62) and 85.5% (53/62) of readers 1 and 2, respectively. Using the MPR, the rates increased to 93.5% (58/62) and 95.2% (59/62), respectively (κ = 0.760 and 0.792, respectively). Factors for invisibility were the course of feeding arteries in the anteroposterior plane, proximity to large enhancing vessels, adjacency to the chest wall, pulsation of the heart, and small feeding arteries. Thirty-seven PAVMs in five patients had angiographic confirmation of reperfusion status after embolization (32 occlusions and 5 reperfusions). TR-MRA showed 100% (5/5) sensitivity and 100% (32/32, including three cases in which the feeding arteries were not visible on TR-MRA) specificity for both readers. Conclusion: Single-shot whole thoracic TR-MRA with MPR showed good visibility of the feeding arteries of PAVMs and high accuracy in diagnosing reperfusion after embolization. Single-shot whole thoracic TR-MRA may be a feasible method for the follow-up of patients with multiple PAVMs.

CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰 (A Study on the Frequency of Occurrence of the Aortic Dissection using CT)

  • 동경래;최성관;장영일;노상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.115-121
    • /
    • 2008
  • 목적: 혈관의 내층과 외층을 급속히 해리시키는 예후가 매우 위험한 질환으로 대동맥 박리증(aortic dissection)의 임상적 진단을 위해 CT를 시행하여 대동맥 박리 증으로 판명된 환자 수와 연령별로 발생 빈도를 조사하고자 하였다. 방법 및 대상: 2005년 1월부터 2006년 12월까지 2년간 C대학병원에 내원한 환자 중 CT를 시행한 환자 112명을 대상으로 연도별로 증감 추세를 조사해 보고, 성별, 연령별, 진료과별로 조사 해 보았으며, 정확한 관찰을 위해 CT scan 후의 재구성 영상인 MIP와 SSD 그리고 VRT영상을 획득하여 CT와 일반 Chest PA 상을 비교하여 결과를 조사 연구하였다. 결과 및 결론: 1. CT를 시행한 환자 112명을 대상으로 연도별 검사건수는 2005년도 37명으로 41.9%를 보였고, 2006년도는 65명으로 58.1%로 2005년에 비해 2006년에 1.4배 증가되었다. 2. CT를 시행한 환자의 성별분포는 남성이 45명으로 40.1%, 여성이 67명으로 59.9%를 차지하고 있고 남성 45명 중 대동맥 박리증 환자는 9명으로 20%, 여성은 67명 중 21명으로 31.3%로 대동맥 박리증 환자가 남성에 비해 여성이 1.6배 많이 발생되었다. 또한 검사자 수도 남성에 비해 여성이 1.5배 많은 것으로 나타났다. 3. CT를 시행한 환자의 연령별 분포는 30세 미만에서는 거의 볼 수 없었으며 41세에서 80세까지가 전체에 88.3%를 차지하였으며 연령이 높을수록 대동맥 박리증 질환의 발생빈도가 높게 나타났다. 연령별 발생빈도의 차이는 통계적으로 유의하였다(p < 0.01). 4. CT를 의뢰한 과는 응급의학과에서 46명(41.1%), 순환기 내과에서 37명(33.0%), 흉부외과에서 13명(11.6%), 기타 과에서 16명(14.3%)으로 응급의학과와 순환기내과가 전체의 74.1%로 나타났다. 따라서 대동맥 박리증 질환의 환자는 주로 응급실로 내원하는 매우 위험한 질환이라는 것을 알 수 있다. 5. 대동맥 박리 환자 30명 중 22명(73.3%)은 일반 X-ray상 정상으로 판독되었고, 8명(26.7%)만이 일반 X-ray상 이상소견이 나왔다. 따라서 대동맥 박리 질환을 정확히 평가하기 위해서는 반듯이 CT를 시행해야 할 것으로 사료되었다.

  • PDF