• Title/Summary/Keyword: Chest Radiography

Search Result 369, Processing Time 0.032 seconds

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System (디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구)

  • Park, Ji-Koon;Jung, Bong-Jae;Park, Hyong-Hu;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2016
  • Despite of increasing the use of the digital imaging device in the radiology area, the setting on the optimal irradiation conditions are insufficient. In this study, the exposure dose and image quality by exposure condition of digital radiography device were compared. The exposure doses were obtained by adjusting the exposure condition as 5 steps respectively based on the exposure conditions that are currently used of CR and DR radiography devices. The acquired image has been assessed by 20 medical image professors using the assessment method of the Japanese Society for Tuberculosis Prevent. As a result, in the case of the CR system, the better image quality was obtained in the condition of 120 kVp and 1.5 mAs~2.4 mAs (quality score 91~95.5 points) than standard exposure condition(110 kVp, 3.2 mAs, 86 points). And exposure dose was evaluated as low with $61.3{\sim}98.4{\mu}Gy$ than standard condition($105.11{\mu}Gy$). In DR system, however, the image quality score was higher as 97~98.6 points in the lower tube voltage range (112 kVp, 2.4~3.2 mAs) condition than the standard exposure condition (125 kVp, 3.2 mAs, 91 points). In addition, the exposure dose was $61.5-77.2{\mu}Gy$ lower than standard condition($93{\mu}Gy$). In addition, the exposure dose was low as $61.5-77.2{\mu}Gy$ than standard condition($93{\mu}Gy$). With the results of this study, we confirmed that it is possible to reduce the patient exposure dose with the same image quality by adjusting the optimal exposure condition of digital device.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

Study of the Optimize Radiotherapy Treatment Planning (RTP) Techniques in Patients with Early Breast Cancer; Inter-comparison of 2D and 3D (3DCRT, IMRT) Delivery Techniques (유방암 방사선치료 시 최적의 방사선치료계획기법에 대한 고찰)

  • Kim, Young-Bum;Lee, Sang-Rok;Chung, Se-Young;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • Purpose: A various find of radiotherapy treatment plans have been made to determine appropriate doses for breasts, chest walls and loco-regional lymphatics in the radiotherapy of breast cancers. The aim of this study was to evaluate the optimum radiotherapy plan technique method by analyzing dose distributions qualitatively and quantitatively. Materials and Methods: To evaluate the optimum breast cancer radiotherapy plan technique, the traditional method(two dimensional method) and computed tomography image are adopted to get breast volume, and they are compared with the three-dimensional conformal radiography (3DCRT) and the intensity modulated radiotherapy (IMRT). For this, the regions of interest (ROI) such as breasts, chest walls, loco-regional lymphatics and lungs were marked on the humanoid phantom, and the computed tomography(Volume, Siemens, USA) was conducted. Using the computed tomography image obtained, radiotherapy treatment plans (XiO 5.2.1, FOCUS, USA) were made and compared with the traditional methods by applying 3DCRT and IMRT. The comparison and analysis were made by analyzing and conducting radiation dose distribution and dose-volume histogram (DVH) based upon radiotherapy techniques (2D, 3DCRT, IMRT) and point doses for the regions of interest. Again, treatment efficiency was evaluated based upon time-labor. Results: It was found that the case of using 3DCRT plan techniques by getting breast volume is more useful than the traditional methods in terms of tumor delineation, beam direction and confirmation of field boundary. Conclusion: It was possible to present the optimum radiotherapy plan techniques through qualitative and quantitative analyses based upon radiotherapy plan techniques in case of breast cancer radiotherapy. However, further studies are required for the problems with patient setup reproducibility arising from the difficulties of planning target volume (PVT) and breast immobilization in case of three-dimensional radiotherapy planning.

  • PDF

Shape and Incidence of Rib Variations in Chest Radiographs (단순흉부촬영상 관찰되는 늑골 변이의 양상 및 빈도)

  • Joo, Ji-Seon;Bae, In-Young;Kim, Sung-Tae;Kwak, Seung-Min;Cho, Chul-Ho;Cho, Seung-Wook;Park, Chan-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • Background: The literature on variations of rib is limited. Very little has been written in the radiological journal of this country on the subject. It seemed of interest to investigate the nature and incidence of congenital variations in a series of routine chest roentgenograms. The topic of rib variations has not been covered extensively in the radiological journals in Korea. This has presented an opportunity to investigate the nature, type, shape and incidences of congenital rib variations in normal Korean adults from a series of routine roentgenograms. Methods: Chest radiographs of 5,000 adults, who visited our hospital for a routine check-up or for employment physical examinations from January 1996 to September 1998, were consecutively reviewed. The sex distribution consisted of 2,827 male males and 2,173 female females(ratio of 1.3:1) with the age range aged between 19 and 65 years(mean age: 34.6 years) were included. The chest PAs were analyzed for the presence, type, location, and shape of the rib variations. From this data the incidence of each type of variations was calculated. Results: Seventy-six of the 5,000 adults(1.52%), 63 male(2.23%) and 13 female(0.6%), showed 88 cases of rib variation(Table 1). The most common variation was the bifid rib(n=35), followed by hypoplasia of the rib(n=22), flaring of the rib(n=18), bridging of the ribs(n=7), cervical ribs(n=3), and fusion of between ribs(n=3)(Table 2). The bifid rib(Table 1) was found most frequent in the right fourth rib(12/35, 34.3%), followed by the left fifth rib(6/35, 17.1%) and right third rib(6/35, 17.1%). Hypoplasia of the rib was common in first rib(20/22, 90.9%). Flaring of the rib was common at fourth rib(8/18, 44.4%, right and left combined), and bridging between ribs was common between first and second rib(3/7, 42.9%). Conclusion : The percentage of incidence of rib variations in adults was 1.52%. Bifid rib was the most common variation, followed by hypoplasia, flaring, bridging, cervical rib, and fusion of ribs, in decreasing order.

  • PDF

Spontaneous Pneumomediastinum: Clinical Investigation (자연성 종격동 기종의 임상적 고찰)

  • Park Jae Hong;Chei Chang Seck;Hwang Sang Won;Kim Han Yong;Yoo Byung Ha;Kim Dae Hwan
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.220-225
    • /
    • 2006
  • Background: Spontaneous pneumomediastinum is an uncommon, benign, self-limited disorders that usually occurs in young adults without any apparent precipitating factors or disease. The purpose of this study was to review our experience in dealing with this entity and describe a reasonable course of assessment and management. Material and Method: A retrospective case series was conducted to identify adults patients with SPM who were diagnosed and treated in a single institution between 2001 and 2005. Result: Fifteen patients were identified who included 14 men and 1 women with a mean age of 26 years. Presenting symptoms were chest pain in 12 patients ($80\%$), dyspnea in 5 patients ($33\%$), and throat discomfort in 4 patients ($26\%$). Two cases were associated with use of inhalational drugs and 3 cases were associated with exercise. The predisposing factors were asthma, excessive exercise, and vomiting in spontaneous pneumomediastinum. The physical findings were subcutaneous emphysema in 10 patients ($77\%$). Chest radiography and computerized tomography were the diagnostic methods in all cases with CT scan revealing six cases with associated pulmonary abnormalities. Esophagogram and flexible bronchoscopy were selectively used. Fifteen patients ($100\%$) were admitted to the hospital. Their mean hospital stay was 3 days. All patients were conservatively treated. In a follow-up of 3 years no complications or recurrences were observed. Conclusion: Most simple spontaneous pneumomediastinum cases were benign diseases and most of them ($77\%$) had shown typical chest pain, dyspnea and subcutaneous emphysema. Inhalational drug use was not a major cause of SPM; however, increased use of bronchoinhalers was a suspicious cause of SPM.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

A Study of the Improvement of Clinical and Practical Trainings in the Education of Radiologic Technologists (방사선사(放射線士) 교육(敎育)의 임상실습(臨床實習) 개선(改善)에 관(關)한 연구(硏究))

  • Lee, Man-Koo;Kang, Se-Sik;Yoon, Han-Sik;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.117-129
    • /
    • 1983
  • This study, in order to improve clinical and practical trainings in the education of radiologic technologists, applies to 76 medical institutions of 91 ones which are used as the hospitals of clinical and practical training in 9 existing junior colleges except 3 new ones of 12 ones throughout all over the country from November 1, in 1982 to April 30, in 1983. And the purpose of this study is to research the percent conditions of basic practical trainings and clinical ones enforced in each college, and the percent conditions, equipments, contents, and opinions in clinical and practical trainings enforced in each hospital. The results are summarized as follows; 1. In the case of junior colleges in the whole country the curriculum of basic practical trainings averages 336.66 hours and the limits are between 120 and 510 hours. The actual hours in practice average 140 hours and the limits are between 60 and 240 hours, which correspond to 41.58% of the curriculum of basic practical trainings. 2. There were three junior colleges among nine that had a reserved hospital for clinical and practical trainings(only 33.33%). 3. The period of the practice was almost vacation in 4 junior colleges. The practice was conducted only for students to want the practice(44.45%), junior colleges that all students in them conducted the practice was 2 junior colleges and presented 22.22%. 4. In the field of students engaging in the practice, each field of radiation therapy and nuclear medicine presented 16.5%, 20.3% and almost students didin't have experience for the practice. 5. In medical institutions the educational institutions for intern showed 67.11%. Hospital with radiologist showed 26.32%. Radiotechnologist who had experience below 5 years presented 60.17%. 6. In the equipment for radiation diagnosis, each hospital had no difference. The number of hospitals passessing diagnostic equipments above 125 KVP was 56.26%. But radiation therapy equipment and nuclear medicine equipment had extremely low rate. 7. In the diagnosis of patient in the practice hospital, conventional radiography-to Skull, Chest, Abdomen, Skeleton, Urogenital system-reached the criterion. But special radiography was comparatively low. There appeared low rate, 32.89% in the field of nuclear medicine, 15.79% in the field of radiation therapy. 8. Students who carried out the practice were 1-89 students, days in practice were 1-30 days. There were differences in that point among among hospitals. Junior colleges conducting the practice were 2 colleges per hospital. Scope of the object were 1-8 junior colleges. 9. The practice conducted for the request of the colleges presented 72.37%, in addition, The prctices were conducted for growth of the younger generation and the same coperation with the colleges establishment of sisterhood with the colleges, relationship with students. 10. The practice conducted without the establishment of plan presented 59.21% The need for guiding book to the practice and evaluating was recognized over 90%. 11. In the relation between the practice with achievement of credit. There were big differences in opinion between hospitals-Group and the colleges-Group; hospital-Group had opinion that must follow achievement of credit with the practice. The colleges-Group had opinion that must conduct the practice after achieving credit. 12. After conducting the practice, in the practice leaders satisfaction degree dissatisfactory opinion presented the most rate 80.26%. Very much satisfactory opinion, as one hospital, presentd only 1.32%. 13. Both hospitals-Group and the colleges-Group had an opinion that the practice leader must have actual experiences, lectures and achievement, an opinion that actual experiences is over 5 years. 14. In the guide of human relation, cooperation, responsibility, courtesy to patients. Both hospitals-Group and the colleges-Group had an opinion that the guide must be involved in the period of the practice and must be instructed.

  • PDF