• Title/Summary/Keyword: Chest Radiography

Search Result 366, Processing Time 0.029 seconds

Congenital hernia of the lung through the azygoesophageal recess (Azygoesophageal recess를 통한 선천 폐탈장)

  • Choi, Young Seok;Son, Young Jun;Bae, Si Young;Min, Kyung Sun;Cho, Young Kuk;Choi, Woo Yeon;Choi, Young Youn;Ma, Jae Sook;Hwang, Tai Ju
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.10
    • /
    • pp.1123-1126
    • /
    • 2008
  • A lung hernia, defined as the protrusion of pulmonary tissue and pleural membranes through a defect in the thoracic wall, is a rare event. It can be congenital or acquired, and cervical, thoracic, or diaphragmatic in location. We report the rare occurrence of a congenital atraumatic lung herniation through the azygoesophageal recess. An 8-month-old male infant, who was born at 35 weeks gestation, had a chronic cough. Chest radiography showed haziness at the right lower lobe of the lung (RLL). Chest computed tomography (CT) revealed herniation of the RLL through the azygoesophageal recess. If persistent unilateral haziness is observed on chest radiography, the possibility of lung herniation should be considered.

Visual Evaluation of Rib Shadow and Lung Marking during High-voltage Chest Radiography (흉부 고관전압 촬영에 있어서의 늑골음영과 폐문리의 시각적 평가)

  • Choi, Kwon-Kyu;Lee, Chang-Yup;Shin, Dong-Sik;Kim, Chang-Nam;Choi, Ki-Young;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 1992
  • Visual evaluation of rib shadow and lung marking during high voltage chest radiography. The Purpose of this study is to improvement of visual discrimination of pulmonary structures on the conventional chest radiogram. The author prepared an artificial lung using an acryl plate, 8 cm in thickness, which is nearly equivalent to human lung, and 0.6 cm thickness of an aluminum plate for an artificial rib, and 0.5 cm of an acryl plate as a pulmonary vessel as well. And they were used as objects for experimental radiograms. This study performed with gradual increasing densities of film bases in the sequences of densities of 0.6, 0.9, 1.1 and 1.3. We made two combinations of images after multiple and regular cuts, with width of 1 cm, of 4 radiograms at the above mentioned densities of film bases. One image consisted of alternative combination of radiograms taken at densities of 0.6 and 1.3, and the other did at 0.9 and 1.1. The latter image provided better visual perception of pulmonary structures than the former. Experimental radiograms were also taken with 60 kV and 120 kV respectively. After careful evaluation and comparison to images taken on varieties of different densities with combinations and kV, the author had a conclusion that it is advisable to use a high kV X-ray which makes rib shadow subtle, for better visual delineation of pulmonary structures behind ribcage, eventhough contrast of pulmonary structures are decreased at high kV radiogram.

  • PDF

Reverse V-Shape Kinking of the Left Lower Lobar Bronchus after a Left Upper Lobectomy and Its Surgical Correction

  • Kim, Min-Seok;Hwang, Yoohwa;Kim, Hye-Seon;Park, In Kyu;Kang, Chang Hyun;Kim, Young Tae
    • Journal of Chest Surgery
    • /
    • v.47 no.5
    • /
    • pp.483-486
    • /
    • 2014
  • A 76-year-old male underwent a left upper lobectomy with wedge resection of the superior segment of the left lower lobe using video-assisted thoracoscopic surgery (VATS) for non-small-cell lung cancer of the left upper lobe. He presented with shortness of breath, fever, and leukocytosis. Chest radiography showed atelectasis at the remaining left lower lobe. Bronchoscopy revealed narrowing of the left lower bronchus with purulent secretion, and computed tomography showed downward kinking of the left lower lobar bronchus. He underwent exploratory VATS, and intraoperative findings showed an inferiorly kinked left lower lobar bronchus with upward displacement of the left lower lobe. After adhesiolysis, the kinked bronchus was straightened, and bronchopexy was performed to the pericardium to prevent the recurrence of bronchial kinking. Also, the inferior pulmonary ligament was reattached to prevent upward displacement. Postoperative follow-up bronchoscopy revealed no evidence of residual bronchial obstruction, and chest radiography showed no atelectasis thereafter.

Congenital Thoracic Ectopic Kidney associated with Diaphragmatic Hernia in a 15-month-old Boy (선천성 횡격막 탈장과 동반된 이소성 흉강내 신장 1례)

  • Yang, Eu Jeen;Jeong, Yeon Jun;Hwang, Pyoung Han;Lee, Dae-Yeol;Kim, Min Sun
    • Childhood Kidney Diseases
    • /
    • v.18 no.2
    • /
    • pp.106-110
    • /
    • 2014
  • Congenital thoracic ectopic kidney is a very rare developmental disorder and the rarest type of ectopic kidney. This condition is usually asymptomatic and detected incidentally on routine chest radiography. Most cases of thoracic ectopic kidney develop in adulthood and during the neonatal period, and congenital thoracic ectopic kidney rarely develops in children. Most patients are asymptomatic, and the treatment depends on the diagnosis. Herein, we report a rare case of ectopic thoracic kidney associated with a diaphragmatic hernia in a 15-month-old male infant, who presented with periodic severe irritability. The thoracic ectopic kidney was detected as a mass in the right base of the chest on routine chest radiography.

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Left Diaphragmatic Eventration Diagnosed as Congenital Diaphragmatic Hernia by Prenatal Sonography (선천성 횡격막 헤르니아로 오인된 좌측 횡격막 내장탈출 2예)

  • Yeom, Jung-Sook;Park, Ji-Sook;Park, Eun-Sil;Seo, Ji-Hyun;Lim, Jae-Young;Park, Chan-Hoo;Woo, Hyang-Ok;Jung, Eun-Jung;Jo, Jae-Min;Youn, Hee-Shang
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.92-97
    • /
    • 2006
  • Congenital diaphragmatic eventration is the abnormal elevation of the diaphragm into the thoracic cavity. Sometimes, it is not easy to differentiate congenital diaphragmatic eventration from diaphragmatic hernia by either prenatal sonography or postnatal chest radiography. However, differential diagnosis of both diseases is practical because of different prognosis and surgical approaches. Careful interpretation of postnatal serial chest X-rays is mandatory to differentiate between both diseases. We report two neonates with congenital diaphragmatic eventration of left diaphragm that initially misdiagnosed as diaphragmatic hernia by prenatal sonography and postnatal chest radiography.

  • PDF

A late onset solitary mediastinal cystic lymphangioma in a 66-year-old woman who underwent kidney transplantation

  • Lee, Jung Mo;Lee, Sang Hoon;Park, Youngmok;Kim, Chi Young;Goag, Eun Kyoung;Lee, Eun Hye;Park, Ji Eun;Lee, Chang Young;Kim, Se Kyu
    • Journal of Yeungnam Medical Science
    • /
    • v.32 no.2
    • /
    • pp.155-158
    • /
    • 2015
  • Lymphangioma is a congenital abnormality of the lymphatic system detected primarily in early childhood. There are rare reports of mediastinal lymphangioma in older adults. We hereby report on a 66-year-old female patient who underwent kidney transplantation 20 years previously and who developed pathologically confirmed solitary mediastinal lymphangioma 1 year ago. Chest radiography showed a mediastinal nodule, which was not observed 2 year previously, therefore she was referred to the pulmonary division. She had no symptoms, and chest computed tomography demonstrated a 25-mm, well-defined, low-density nodule located at the anterior mediastinum. The size of the nodule had increased from 25 mm to 34 mm 1 year later, and it was completely resected via video-assisted thoracic surgery. The histological diagnosis was cystic lymphangioma. Therefore, we recommend that clinicians consider cystic lymphangioma as a possible diagnosis even in older patients with a mediastinal cystic mass that shows progressive enlargement.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

A case report of gastrointestinal perforation in patient after biliary stent insertion and the overview of gastrointestinal perforation (담도 스텐트 시술 후 장천공 증례보고 및 장천공에 대한 고찰)

  • Ga-Young Lee;Chan-Ran Park;Jung-hyo Cho;Chang-gue Son;Nam-hun Lee
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.195-203
    • /
    • 2022
  • Objectives: This study aimed to emphasize the importance of accurate and timely diagnosis of acute abdominal pain with simple radiography by reporting a case of gastrointestinal perforation. Methods: We closely observed the diagnosis and progress of acute abdominal pain after biliary stent and reviewed the outline of gastrointestinal perforation. Results: Patient diagnosed with urethral cancer metastasis to lung and peritoneum was treated with complex Korean medicinal treatments to deal with anorexia, abdominal pain, jaundice and oliguria. During hospitalization, the patient's acute abdominal pain after biliary stent was diagnosed with gastrointestinal perforation by using plain chest and abdominal radiography. Conclusion: Using simple radiography to find out the emergency diseases such as perforation in acute abdominal pain is important clinically.

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF