• 제목/요약/키워드: Chest CT scan

Search Result 302, Processing Time 0.029 seconds

The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans (PET 검사에서 CT 장비의 차이에 따른 PET/CT의 SUV 비교 평가)

  • Kim, Woo Hyun;Go, Hyeon Soo;Lee, Jeong Eun;Kim, Ho Sung;Ryu, Jae Kwang;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Purpose: Among different PET/CT devices which are composed of same PET model but different CT models, SUV, usually used for quantitative evaluation, was measured to assess the accuracy of follow up scans in different PET/CT and confirm that interequipment compatibility is useful in arranging the PET/CT exam appointment. Materials and Methods: Using ACR PET Phantom, PET NEMA IEC Body Phantom, SNM Chest Phantom and Ge-68 cylinder Phantom, $SUV_{mean}$ and $SUV_{max}$ was measured by 3 different models of PET/CT (Discovery 690, Discovery 690Elite and Discovery 710, GE) made in same company. ANOVA was used to evaluate the significant difference in the result. Results: In the result, the average of $SUV_{max}$ was D690 (25 mm-1.82, 16 mm-1.75, 12 mm-1.73, 8 mm-1.44), D690E (25 mm-1.76, 16 mm-1.92, 12 mm-1.78, 8 mm-1.55) and D710 (25 mm-1.84, 16 mm-1.89, 12 mm-1.77, 8 mm-1.61) in ACR Phantom, D690 (25 mm-2.26, 16 mm-2.25, 12 mm-1.92, 8 mm-1.85), D690E (25 mm-2.45, 16 mm-2.25, 12 mm-2.05 8 mm-1.91) and D710(25 mm-2.49, 16 mm-2.20, 1 2mm-2.30, 8 mm-2.05) in PET NEMA IEC Body Phantom, D690-1.04, D690E-1.10 and D710-1.09 in SNM Chest Phantom and D690-0.81, D690E-0.81, D710-0.84 in Ge-68 cylinder Phantom. The differences between average SUV of 4 phantoms were $SUV_{mean}$-1.87%, $SUV_{max}$-2.15%. And also as a result of ANOVA analysis, there was no significant difference statistically. Conclusion: If different models of PET/CT have same specification of PET system, there was no significant difference in $SUV_{mean}$ and $SUV_{max}$ even though they have different CT system. And also differences of $SUV_{mean}$ and $SUV_{max}$ in phantom images were under 5% which many manufacturers recommend. Therefore, follow up scan will be possible using different PET/CT if it has same specification of PET system with the previous PET/CT. This information will enable the accurate comparative analysis when conducting follow up scans and be helpful to schedule PET/CT exam more effectively.

  • PDF

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

Correlation of Pre-treatment FDG Uptake to Therapeutic Response and Relapse in Patients with Small Cell Lung Cancer (소세포폐암의 치료전 FDG섭취와 치료반응 및 재발과의 연관성)

  • Seo, Young-Soon;Kwon, Seong-Young;Jeong, Shin-Young;Song, Ho-Chun;Min, Jung-Joon;Kim, Kyu-Sik;Kim, Young-Chul;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.538-545
    • /
    • 2007
  • Purpose: We evaluated correlation of $^{18}F$-FDG uptakes, therapeutic response and relapse in pre-treatment $^{18}F$-FDG PET/CT in patients with SCLC. Materials and methods: We included 26 patients with pathologically proven small cell lung cancer. Total 102 lesions (26 lungs, 69 lymph nodes and 8 metastatic lesions) were evaluated. All patients underwent $^{18}F$-FDG PET/CT for staging. The maxSUV was used as a parameter of $^{18}F$-FDG uptake. The patients were divided into responders and non-responders according to response criteria on chest CT scan after 3 cycles of chemotherapy. We compared maxSUV between two groups by using independent t-test. To access correlation with $^{18}F$-FDG uptake and relapse, maxSUV and interval time to relapse was analyzed by correlation analysis. The cutoff value of maxSUV was evaluated by ROC curve. Results: Twelve-one patients (81%) were responders and five patients were non-responders on follow-up chest CT scan. The mean maxSUV of main lung lesions in responders and non-responders were $14.15{\pm}3.72$ and $9.17{\pm}2.15$, respectively. The maxSUV in the responders was significantly lower than that in non-responders (p<0.05). According to ROC curve, point of cut that predicts therapeutic response was 8.98 with 100% sensitivity and 57% specificity. The correlation analysis between $^{18}F$-FDG uptakes and interval time to relapse showed a significant negative correlation (p<0.05, r=-0.757). Conclusion: The pre-treatment $^{18}F$-FDG uptake of responders was significantly lower than that of non-responders. Patients with high $^{18}F$-FDG uptake in pre-treatment $^{18}F$-FDG PET/CT relapse earlier.

Spontaneously Occurring Chemodectoma in a Yorkshire Terrier Dog

  • Park, Chul;Yoo, Jong-Hyun;Kim, Dae-Young;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.187-191
    • /
    • 2008
  • A 7-year-old, intact female Yorkshire terrier dog was presented for coughing, anorexia, chest pain and dyspnea. Right lateral thoracic radiograph demonstrated a large mass shape on the heart base with decreased cardiac silhouette and severe right deviation of the trachea with the heart shifted to the left thoracic wall was observed on the ventrodorsal thoracic projection. Echocardiographic examination revealed a large rounded mass compressing left atrium around the heart base without signs of pericardial effusion. On computed tomographic (CT) findings, sagittal CT images depicted the possibility of cranial vena caval invasion and heart base involvement of the mass associated with biatrial compression. Dorsal CT image revealed the right deviation of trachea due to the heart base mass and markedly shrunk lung space was detected on the transverse CT image. Because the dog suddenly had died during the recovery from anesthesia after finishing CT scan, necropsy was performed. On gross findings, a large and lobulated mass was located at the base of the heart. A poorly-demarcated, infiltrative, multilobulated tumor composed of polyhedral cells in solid cellular sheets was confirmed based on histopathologic examination. This dog was diagnosed as a chemodectoma. This case report describes the clinical findings, diagnostic consistency of thoracic radiography, echocardiography and CT, and histopathologic confirmation in a spontaneously occurring chemodectoma with a Yorkshire terrier dog.

Descending Necrotizing Mediastinitis Secondary to Peritonsillar Abscess -A Case Report- (편도주위농양에 합병된 하행 괴사성 종격동염 -치험 1례-)

  • 최필조;이용훈;우종수;이기남;손춘희;박헌수;이인규
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.686-689
    • /
    • 1999
  • Descending necrotizing mediastinitis(DNM) is a rare complication of the oropharyngeal and cervical infection. Descending necrotizing mediastinitis requires an early and aggressive surgical approach to reduce the high morbidity and mortality associated with this disease. A 39-year-old man complained of odynophagia, neck swelling, and disturbance of swallowing with dyspnea. CT scans of the neck suggested a peritonsillar abscess and retropharyngeal and peripharyngeal abscess. He underwent cervical drainage. He remained febrile and complained of severe both pain in both shoulders. On postoperative day 5, a follow-up CT scan confirmed a mediastinal abscess. Reexploration of the neck and right thoracotomy for debridement and drainage of the mediastinal abscess were performed.. A large amount of pus was drained from the anterior and posterior mediastinum and its necrotic tissue was debrided. The patient's condition and radiologic findings gradually improved. Cultures of the drain fluid revealed Klebsiella pneumoniae. He was discharged on the 85th hospital day. In our experience, both transcervical drainage and aggressive mediastinal exploration via thoracotomy can lead to an improvement in the survival of the patient with descending necrotizing mediastinitis. CT scanning is useful for early diagnosis of mediastinitis and for follow up.

  • PDF

Prestenotic Bronchial Radioaerosol Deposition: A New Lung Scan Sign of Bronchial Obstruction (기관지 협착 근위부의 연무 침착: 폐스캔에서 기관지 폐색의 특이한 지표)

  • Chung, Soo-Kyo;Kim, Hak-Hee;Choi, Byung-Gil;Lee, Sang-Hoon;Kang, Si-Won;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.307-312
    • /
    • 1995
  • The present study has been carried out to assess the diagnostic usefulness of radioaerosol lung scan in complete bronchial obstruction (n=7) and bronchial narrowing (n=1) of varying causes. $^{99m}Tc$-phytate lung scan was performed using the aerosol generated by a BARC nebulizer. Scan alterations were correlated with those of chest radiography, bronchography, lung CT and/or brochoscopy. In every case scan showed characteristic intense deposition of radioaerosol in a short slightly dilated, bronchial segment immediately proximal to obstruction or stenosis. Characteristically it was accompanied by an airspace aerosol deposition defect distally. The finding of a short, clubbed, bronchial radioaerosol deposition with distal airspace defect is a sensitive, specific indicator of bronchial obstruction or stenosis. It was especially useful in the detection of the obstruction of a small bronchus at the lobar and sublobar levels. We propose to name it the prestenotic aerosol deposition sign.

  • PDF

Application of Low-Dose CT for Screening of Lung Disease (폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용)

  • Lee, Won-Jeong;Choi, Byung-Soon;Park, Young-Sun;Seon, Jong-Ryul;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.129-140
    • /
    • 2009
  • As CT has been increasingly used as an accurate screening tool for lung disease, radiation dose becomes an important issue for both radiographers and patients. Many researches have been done for a low-dose CT as a screening tool for early detection of asymptomatic lung diseases. From those studies, it has been reported that chest dose rate from the low-dose CT is considerably lower than from standard CT. The patient dose is determined by scanning parameters such as kVp, mAs, pitch, scan time and the radiation risk of lung in screening examination may not be negligible. Herein, we suggest that Low-dose CT is useful as a screening tool in routine clinical practice on the basis of published articles, but further study is necessary because Low-dose CT has poor sensitivity and specificity for screening early stage of lung cancer according to the results of the studies. This article is to provide a brief overview of the screening examinations by Low-dose CT.

  • PDF

Assessment of Allograft Function in Dog Single Lung Transplantation on CT (한국산 잡견에서 컴퓨터단층촬영을 이용한 이식폐의 기능평가)

  • 박기성;박창권
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1055-1061
    • /
    • 1997
  • In the field of the experimental lung transplantation, we analyzed the CT findings of acute rejection, infection in the left single allotransplanted lung of adult mongrel dogs, and the CT findings were compared with the histological findings obtained by the lung biopsy Twenty two adult mongrel dogs were divided into two groups(Donor and recipient group). Donor lungs were flushed with LPDG(low pota,ilium dextral glucose) solution(n=4) or modified Euro-collins solution(n=7) and preserved over 20 hours with $10^{\circ}C(1$ case preservation for 4hours). After left single lung transplantation, the chest X-ray and sequential computed tomogram were performed with concomitant hemodynamic study and arterial blood gas analysis on immediate postoperative period, postoperative 3rd day and postoperative 7th day. Two of eleven transplanted lungs had acute rejection which was represented as moderate infiltration at immediate or 1st postoperative d y but became extensive infiltration at postoperative 3rd day on CT. There were showed one case of bronchopleural fistula, six cases of pneumonia and two cases of pulmonary infarction. In one rejection cases, the opacity of transplanted lung was improved by injection of methylprednisolone 500mg daily during 3 days. We concluded that CT was a useful noninvasive evaluation parameter after lung transplantation and the serial CT scan enabled early detection of acute rejection.

  • PDF

A Clinical Study on the Factors that Influence Functional Evaluation of Stroke (중풍의 기능평가에 영향을 미치는 요인에 관한 임상적 고찰)

  • 박숙자;권정남;김영균
    • The Journal of Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.73-90
    • /
    • 2002
  • Objectives: This study investigated significant factors that influence functional evaluation of stroke so as to be a fundamental data for estimating prognosis of stroke patients. Methods: 204 patients were studied within 7 days of admission, after the diagnosis of stroke through brain CT scan, brain MRI scan and clinical observations. They were hospitalized in the oriental medical hospital of Dongeui University from February to July in 2001. They were examined at the early stage of onset, after 2 weeks, 4 weeks and 6 weeks, and measured for average mark and the degree of improvement by using the Activity Index. Results: Ischemic stroke, past history of stroke, hypertension, diabetes mellitus, risk factor of obesity, non-professional emergency treatment and hospitalizing time after 1 day from onset, high blood pressure, tachycardia pulse and high blood sugar in abnormal vital sign in acute stage, conscious, cognitive or communication disorder, motor aphasia, dysphagia, constipation for more than 3 days, urinary incontinence, visual field defect, insomnia, and chest discomfort in early stage of onset had a negative influence on functional evaluation. Conclusions: Type of stroke, past history, risk factors, emergency treatment and hospitalizing time after onset, abnormal vital sign and intercurrent symptoms in Acute stage were relevant factors in predicting functional evaluation of stroke.

  • PDF

A Case of Malignant T Cell Lymphoma of Chest Wall (흉벽에 발생한 악성 T 세포 임파종 1예)

  • Hwang, Eai-Suk;Kim, Hyung-Jung;Lee, Jong-Hwa;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young;Kim, Sang-Jin;Choi, Youn-Jung;Jung, Woo-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.192-196
    • /
    • 1993
  • Malignant T cell lymphoma is a morphologically and immunologically distinct subtype of non-Hodgkin's lymphoma. One of the most striking clinical findings is relatively high incidence in males in their twenties or thirties with cervical, supraclavicular and axillary lymphadenopathy (50%), mediastinal mass (50%) or less commonly with extranodal disease. More than 90% of patients present with stage III or IV disease and approximately 60% of patients develop bone marrow infiltration. Clinical trials are needed to optimize therapeutic strategies, since these tumors have a poor prognosis and need to be treated aggressively. A 17-year-old male was admitted to the hospital because of chest pain. Chest PA and CT scan revealed massive pleural effusion and soft tissue masses with destructive change of right third and eighth ribs Histologic diagnosis of pleura and chest wall mass revealed high grade, pleomorphic T cell type, malignant lymphoma.

  • PDF