• Title/Summary/Keyword: Chest CT

Search Result 1,001, Processing Time 0.024 seconds

Non-rigid Registration Method of Lung Parenchyma in Temporal Chest CT Scans using Region Binarization Modeling and Locally Deformable Model (영역 이진화 모델링과 지역적 변형 모델을 이용한 시간차 흉부 CT 영상의 폐 실질 비강체 정합 기법)

  • Kye, Hee-Won;Lee, Jeongjin
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.6
    • /
    • pp.700-707
    • /
    • 2013
  • In this paper, we propose a non-rigid registration method of lung parenchyma in temporal chest CT scans using region binarization modeling and locally deformable model. To cope with intensity differences between CT scans, we segment the lung vessel and parenchyma in each scan and perform binarization modeling. Then, we match them without referring any intensity information. We globally align two lung surfaces. Then, locally deformable transformation model is developed for the subsequent non-rigid registration. Subtracted quantification results after non-rigid registration are visualized by pre-defined color map. Experimental results showed that proposed registration method correctly aligned lung parenchyma in the full inspiration and expiration CT images for ten patients. Our non-rigid lung registration method may be useful for the assessment of various lung diseases by providing intuitive color-coded information of quantification results about lung parenchyma.

Development and Radiation Shield effects of Dose Reduction Fiber for Scatter ray in CT Exams (피폭선량저감 섬유의 개발과 CT 검사시 산란선 차폐 효과)

  • Kim, Sunghwan;Kim, Yong Jin;Kwak, Jong Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1871-1876
    • /
    • 2013
  • In this study, we developed and characterized the shielding properties of dose reduction fiber (DRF, Buffalo Co.) sheet during brain and chest CT examinations. The DRF sheet was composed of $1{\sim}500{\mu}m$ oxide Bismuth ($Bi_2O_3$) and 5 ~ 50 nm nano-barium sulfate ($BaSO_4$). Phantom and clinical studies were performed for characterization of the DRF shielding properties. In clinical study, we measured doses of eye, chest, abdomen and reproductive system of 60 patients in 3 hospitals during brain and chest CT examinations. We could determined the shielding effect of the DRF by comparing the doses when we used the DRF sheet or not. When we used the sheet during CT examination, the scattered dose were reduced about 20~50%. So, we suggest that the fiber should be used in radiological examinations for reducing patients doses.

p53 Expression in a Malignant Mesothelioma Patient during Seven-Year Follow-up

  • Koo, So-My;Uh, Soo-Taek;Kim, Dong Won;Kim, Ki-Up;Kim, Yang-Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.6
    • /
    • pp.284-288
    • /
    • 2014
  • Malignant mesothelioma (MM) is the aggressive tumor of serosal surfaces. There are crude pathogenetic results regarding the biology of MM. Coordinated upregulations of p53 gene expression are shown in malignancies. We believed that there are changes in the p53 expression with transformation from reactive hyperplasia to MM. A 65-year-old male was admitted the hospital because of left pleuritic chest pains in 2004. Chest computed tomography (CT) results showed left pleural effusions with loculation and pleural thickening. Pathologic findings revealed reactive mesothelial hyperplasia. In 2008, the patient again felt left pleuritic chest pains. Chest CT showed progressive thickening of the left pleura. Pathologic diagnosis was atypical mesothelial hyperplasia. In 2011, chest CT showed progressive thickening of his left pleura. He was diagnosed with well-differentiated papillary mesothelioma. Serial change was analyzed by immunohistochemical staining for p53 of pleural tissues. There were no remarkable changes in p53 expressions during the transformation to MM.

Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines - (진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 -)

  • Lee, Won-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.206-212
    • /
    • 2014
  • We report here on the results of evaluating the radiation doses using chest computed tomography (CT) for patients with pneumoconiosis complication. For the first time, we visited the 17 MIPs to evaluate the dose-length product (DLP, $mGy{\cdot}cm$), CT unit, and protocols of scanning and image reconstruction those is routinely used for treating patients with pneumoconiosis who have complication. All statistical analysis was performed using the Statistical Program for Social Sciences (SPSS ver. 19.0, Chicago, IL, USA). Mean of total DLP was $727.7mGy{\cdot}cm$, ranging from 272.0 to $1228.7mGy{\cdot}cm$. DLP from obtaining parenchymal lung images was significantly reduced than that from obtaining total lung images (555.9 vs. 707.2, p<0.001). Third quartile of total and pre-scanning DLP was 1036.1 and $504.1mGy{\cdot}cm$, respectively. Chest CT radiation doses for patients with pneumoconiosis complication are similar with korean diagnostic reference level as well as international guidelines.

Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry (인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.933-939
    • /
    • 2019
  • The purpose of this study is to provide basic clinical data by evaluating images, measuring absorbed dose and effective dose by using high resolution CT and low dose CT by using anthropomorphic chest phantom and glass dosimeter. Tissue dose was measured by inserting a glass dosimeter into the anthropomorphic chest phantom. A 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany) and CARE Dose 4D were used, and the parameters of the high resolution CT were 120 kVp, Eff. Scan parameters of mAs 104, scan time 7.93 s, slice 1.0 mm (Acq. 64 × 0.6 mm), convolution kernel (B60f sharp) were used, and low dose CT was 120 kVp, Eff. mAs 15, scan time 7.41 s, slice 3.0 mm (Acq. 64 × 0.6 mm), scan of convolution kernel B50f medium sharp. CTDIvol was measured at 8.01 mGy for high resolution CT and 1.18 mGy for low dose CT. Low dose CT scans showed 85.49% less absorbed dose than high resolution CT scans.

Congenital cystic adenomatoid malformation (선천성 낭종성 선종양기형)

  • 육을수
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.196-200
    • /
    • 1995
  • Congenital Cystic Adenomatoid Malformation [C.C.A.M. is rare, cause acute respiratory distress in the newborn infants. The histologic features are cystic areas and marked proliferation of terminal respiratory structures. On case 1, the patient was 8-month-old male, and suffered from acute respiratory distress and cyanosis. The pulmonary cystic lesion was detected in right lung at birth and has been evaluated since birth. The study for diagnosis were chest x-ray and chest CT. A right upper lobectomy was urgently performed and he was discharged with a satisfactory postoperative course. On case 2, the patient was 20-year-old female, and suffered from cough and sputum for 2 months. The study for diagnosis were chest x-ray, chest CT, and pulmonary angiography. The cystic lesion was detected in left lung and difficult to distinguish from pulmonary sequestration. A left lower lobectomy was performed and she was discharged with a satisfactory postoperative course. We report two cases of C.C.A.M. with differential clinical course.

  • PDF

The Role of Chest CT Scans in the Management of Empyema (농흉에서 전산화 단층촬영의 의의)

  • Heo, Jeong-Suk;Kwun, Oh-Yong;Sohn, Jeong-Ho;Choi, Won-Il;Hwang, Jae-Seok;Han, Seung-Beom;Jeon, Young-June;Kim, Jung-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.397-404
    • /
    • 1994
  • Background: To decide the optimal antibiotics and application of chest tube, examination of pleural fluid is fundamental in the management of empyema. Some criteria for drainage of pleural fluid have been recommended but some controversies have been suggested. Recently, newer radiologic methods including ultrasound and computed tomography scanning, have been applied to the diagnosis and management of pleural effusions. We undertook a retrospective analysis of 30 patients with pleural effusion who had CT scans of the chest in order to apply the criteria of Light et al retrospectively to patients with loculation and to correlate the radiologic appearance of pleural effusions with pleural fluid chemistry. Method: We analyzed the records of 30 out of 147 patients with pleural effusion undergoing chest CT scans. Results: 1) Six of the pleural fluid cultures yielded gram negative organisms and three anaerobic bacterias and one Staphylococcus aureus and one non-hemolytic Streptococci. No organism was cultured in ninteen cases(63.0%). 2) The reasons for taking chest CT scans were to rule out malignancy or parenchymal lung disease(46.7%), poor response to antibiotics(40.0%), hard to aspirate pleural fluid(10.0%) and to decide the site for chest tube insertion(3.3%). 3) There was no significant correlations between ATS stages and loculation but there was a tendency to loculate in stage III. 4) There was a significant inverse relationship between the level of pH and loculation(p<0.05) but there appeared to be no relationship between pleural fluid, LDH, glucose, protein, loculation and pleural thickening. 5) In 12 out of 30, therapeutic measures were changed according to the chest CT scan findings. Conclusion: We were unable to identify any correlations between the plerual fluid chemistry, ATS stages and loculations except pH, and we suggest that tube thoracotomy should be individualized according to the clinical judgement and serial observation. All patients with empyema do not need a chest CT scan but a CT scan can provide determination of loculation, guiding and assessing therapy which should decrease morbidity and hospital stay.

  • PDF

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

Chest Radiographs and CT Findings during Healthcare Workers' Tuberculosis Screening Using Interferon- Gamma Release Assay: Retrospective Observational Study (인터페론-감마 분비 검사를 이용한 의료 종사자의 결핵 스크리닝에서 흉부 X선 사진 및 CT 소견: 후향적 관찰 연구)

  • Ye Ra Choi;Jung-Kyu Lee;Eun Young Heo;Deog Kyeom Kim;Kwang Nam Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1524-1533
    • /
    • 2021
  • Purpose To investigate the incidence of tuberculosis (TB) in healthcare workers (HCWs) with positive interferon-gamma release assay (IGRA) results based on chest X-ray (CXR) and CT findings and determine the role of imaging in the diagnosis of TB. Materials and Methods Among 1976 hospital personnel screened for TB using IGRA, IGRApositive subjects were retrospectively investigated. Clustered nodular and/or linear streaky opacities in the upper lung zone were considered positive on CXR. The CT findings were classified as active, indeterminate, inactive, or normal. The active or indeterminate class was considered CT-positive. Results IGRA was positive in 255 subjects (12.9%). CXR and CT were performed in 249 (99.2%) and 113 subjects (45.0%), respectively. CXR- and CT-positive findings were found in 7 of 249 (2.8%) and 9 of 113 (8.0%) patients, respectively. Among the nine CT-positive subjects, active and indeterminate TB findings were found in 6 (5.3%) and 3 (2.7%) patients, respectively. Microbiological tests, including acid-fast bacilli staining, culture, and polymerase chain reaction for TB, were negative in all nine CT-positive subjects. Empirical anti-TB medications were administered to 9 CT-positive subjects, and 3 of these nine subjects were CXR-negative for pulmonary TB.