• Title/Summary/Keyword: Chemical substances

Search Result 1,150, Processing Time 0.025 seconds

Generation of calibration standard gases using capillary gas divider: uncertainty measurement and method validation (다중 모세관을 이용한 교정용 표준가스의 제조: 불확도와 유효성 평가)

  • Lee, Sangyun;Hwang, Eun-Jin;Jung, Hye-Ja;Lee, Kwang-Woo;Chun, Ki-Joon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.369-375
    • /
    • 2006
  • Calibration gas mixtures were prepared using dynamic volumetric method according to ISO 6145-5 and the uncertainty was evaluated. Ten identical capillaries with 0.25 mm in inner diameter and 50 cm in length were applied in this system. Dilution ratio of parent gas was determined by the number of capillaries that passes parent gas and that passes balance gas through. Capillaries were made of Teflon which had good chemical stability against adsorption of gaseous substances. Mechanical valves were introduced in this system in order to minimize the thermal effect of solenoid valves. Concentration of prepared gases were compared with master grade standard gases in cylinders made by RiGAS Co. and calibration of the instrument were completed using comparison method according to ISO 6143. Experimental results showed that the coefficient of variance of diluted oxygen standard gases showed less then 0.2% in most dilution range, that of diluted hydrogen sulfide standard gases showed less then 1.0%. Therefore, it is proven that the standard gases prepared by this system are appropriate to be used as a calibration standards in ambient monitoring, etc.

Ultrastructure of the Granular Glands in the Amphibian Skin (양서루 피부 과립선의 미세구조)

  • Kim, Han-Hwa;Noh, Yong-Tai;Chung, Young-Wha;Chi, Young-Duk
    • The Korean Journal of Zoology
    • /
    • v.22 no.3
    • /
    • pp.103-114
    • /
    • 1979
  • The authors observed the ultrastructure of the granular glands in the amphibian skin with an electron microscope. The specimens from the experimental animals (Bombina orientalis, Bufo bufo gargarizans, Rana nigromaculata and Rana rugosa) were fixed in 2.5% glutaraldehyde-paraformaldehyde fixative in phosphate buffer at pH 7.2 prior to fixation in 1% osmium tetroxide, dehydrated in graded ethanol and acetone, embedded in Epon 812 mixture, and sectioned with a LKB-ultramicrotome. the ultrathin sections were contrasted with uranyl acetate and lead citrate and observed with a JEOL-100B electron microscope. The results were as follws: 1. The granular gland in the amphibian skin consisted of the glandular epithelial and the myoepithelial cells. 2. The epithelial cells of the granular gland in the amphibian skin consisted of the dark cells but the light cells were also observed in that of Bombina orientalis. 3. The granular glands of the amphibian skin were in holocrine fashion. 4. The nuclei of the epithelial cells of the amphibian cutaneous granular glands were round or oval and showed small and large inforldings of nuclear envelope. Heterochromatins were mainly distributed near the nuclear envelope. Mitochondria were mainly distributed in the perinuclear portion and rough-surfaced endoplasmic reticulums were developed in the cytoplasm but smooth-surfaced endoplasmic reticulums were not well developed. 5. Secretory granules were round or oval and electron-dense and less electron-dense granules were observed. 6. The authors infer that the differences in electron density of the secretory granules in the granular glands of the amphibian skin are due to difference in the concentrations of secretory substances as related to the processes of its formation, and that those chemical components are identical.

  • PDF

Electrochemical Mass Transport Control in Biomimetic Solid-State Nanopores (생체모사형 나노포어를 활용한 전기화학 기반 물질전달 조절 시스템)

  • Soongyu Han;Yerin Bang;Joon-Hwa Lee;Seung-Ryong Kwon
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.4
    • /
    • pp.43-55
    • /
    • 2023
  • Mass transport through nanoporous structures such as nanopores or nanochannels has fundamental electrochemical implications and many potential applications as well. These structures can be particularly useful for water treatment, energy conversion, biosensing, and controlled delivery of substances. Earlier research focused on creating nanopores with diameters ranging from tens to hundreds of nanometers that can selectively transport cationic or anionic charged species. However, recent studies have shown that nanopores with diameters of a few nanometers or even less can achieve more complex and versatile transport control. For example, nanopores that mimic biological channels can be functionalized with specific receptors to detect viruses, small molecules, and even ions, or can be made hydrophobic and responsive to external stimuli, such as light and electric field, to act as efficient valves. This review summarizes the latest developments in nanopore-based systems that can control mass transport based on the size of the nanopores (e.g., length, diameter, and shape) and the physical/chemical properties of their inner surfaces. It also provides some examples of practical applications of these systems.

A Comparative Study of Predicted Environmental Concentrations from ECETOC TRA Based on Environmental Release Categories/Specific Environmental Release Categories and K-CHESAR Using Main/Industrial/Use Categories (환경배출범주/특수환경배출범주 기반 ECETOC TRA 및 주요/산업/용도 분류체계 이용의 K-CHESAR에 의한 환경예측농도 비교 연구)

  • Hyun Pyo Jeon;Jisu Yang;Hana Jo;Eun Kyung Choe;Sanghun Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.312-323
    • /
    • 2023
  • Background: Environmental concentrations of substances can be estimated by K-CHESAR based on main, industrial, and use categories (MC/IC/UC) and ECETOC TRA based on environmental or specific environmental categories (ERC or spERC). Objectives: Three different systems for estimating environmental concentrations were compared to figure out their order with possible reasons along with relationship of regional predicted environmental concentrations (PECregional) and final PEClocal for various uses of a substance. Methods: Typical uses of the case substance and their corresponding ERCs were selected from the webpage of the European Chemical Agency. Proper MC/IC/UC and spERC were assigned to each ERC. Emission fractions were compared for each assessment code from the available database. PECs were calculated by three estimating systems: K-CHESAR using MC/IC/UC, ECETOC TRA using ERC, and ECETOC TRA using spERC with their default values for input parameters. Percentage of PECregional to PEClocal were manually calculated for each use. Results: Emission factors decreased in the order of ERC > MC/IC/UC > spERC. Values of the final PEClocal derived as sum of PECregional and Clocal decreased in the order of calculations using ECETOC TRA-ERC>KCHESAR with MC/IC/UC>ECETOC TRA-spERC for all environmental media. Percentages of PECregional,water to PEClocal,water ranged from 0 to 10.3% in industrial uses calculated with MC/IC/UC and ERC but 96.3 to 100% in wide dispersive uses of ERC and spERC where values of Clocal,water are estimated to be very low. Conclusions: ECETOC TRA generated the most refined PNEC values with spERC and the least with ERC, while K-CHESAR with MC/IC/UC generated values between the two results. The ratio of PECregional to PEClocal can be a good measure for performing suitable estimation of PNECs according to use.

Research on the Rheological Properties of Aqueous Film Forming Foam to Respond to Ship Oil Fires (함정 유류화재 대응을 위한 수성막포의 유변학적 특성 연구)

  • Kil-Song Jeon;Hwi-Seong Kim;Jung-Hoon You;Yong-Ho Yoo;Jin-Ouk Park
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.603-607
    • /
    • 2023
  • Aqueous film forming foam (AFFF) is a critical fire suppression agent used in combating hydrocarbon fires. This type of fire suppressant is highly effective due to its ability to form a protective film, dissipate heat, inhibit combustion, and utilize a blend of chemical substances to extinguish fires. While these properties offer significant advantages in responding to hydrocarbon fires, AFFF is distinct in its deployment as it is dispensed in the form of foam. Therefore, the rheological analysis of AFFF foam using a rheometer plays a crucial role in predicting the spray characteristics of AFFF for combating hydrocarbon fires, and this is closely associated with effective fire suppression. In this study, we conducted rheometer experiments to confirm the non-Newtonian behavior (shear-thinning) of AFFF foam and obtained data on the form's stability. These experimental data are expected to contribute to enhancing the efficiency of fire suppression systems utilizing AFFF.

A Study on the Impact of Protection Layers on Workplace Workers in the Event of a Toxic Substance Release (독성물질 누출 시 방호계층 적용에 따른 사업장 내 근로자 피해 영향 연구)

  • Sun Jae Hwang;Joon Won Lee;Deuk Hwan Kim;Sang Chan Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.43-49
    • /
    • 2023
  • Hydrofluoric acid is a less acidic substance than hydrochloric acid, nitric acid, and sulfuric acid, but it is one of the most dangerous substances for humans. In recent years, it has become an indispensable substance in industries such as chemical plants and the semiconductor industry, and although it is a threat to the human body, its use is increasing for various purposes, and the amount of use is constantly increasing due to the expansion and development of the industry. The dangers of hydrogen fluoride have been highlighted since the 2012 accident, which led to a more than fivefold increase in management standards for handling facilities. Hydrogen fluoride converts to hydrofluoric acid when exposed to the air, which can be fatal to humans. This study simulates the effects of a release of a toxic substance in the workplace, even though a protection layer has been provided to minimize the damage caused by the released toxic substance, and recommend ways to control the risk to workers in the event of a release in the workplace.

Application of the Latest European Standard(EN 15522-2) for Marine Oil Spill Analysis: A Study on its Effectiveness in Analyzing Samples from Korean Incidents (해양 기름유출사고 분석을 위한 최신 유럽표준(EN 15522-2) 적용: 한국 사고 샘플 분석의 효율성에 관한 연구)

  • Youjeong Park;Duwon Lee;Heejin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.1
    • /
    • pp.58-64
    • /
    • 2024
  • Approximately 250 marine oil spill accidents have occurred in Korea, with profound impact on local communities and the environment. The restoration process necessitates significant resources and costs to return affected areas to their pre-accident state. In accordance with the polluter pays principle, compensation is demanded from polluter, as stipulated in both international conventions and national laws. Consequently, investigations are conducted to determine civil and criminal liability. As the importance of investigation actors in oil spill accidents increases, standards such as CEN 15522-2 and ASTM D 3248 are employed to determine the similarity between the spilled oil and the oil of the suspected ship. Among these standards, CEN 15522-2, the most actively used European standard, underwent its third revision and is now known as EN 15522-2, as of 2023. This study used EN 15522-2 to analyze samples from marine oil spill accidents that occurred in Korea. The results indicated that, considering the characteristics of domestic spills where light fuel oil spills account for more than 40%, the application of EN 15522-2, which includes low-boiling point substances such as Adamantanes, was confirmed to be highly effective.

Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department (핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰)

  • Sim, Seong-Jae;Shin, Young-Kyun;Moon, Hyeong-Ho;Yoo, Seon-Hee;Jo, Shi-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: The object evaluation method about medical institutes of these days increases credibility of consumers about medical services by conducting a certification system about medical institutes. In addition, as nuclear medicine test rooms and diagnosis test medicine room adopt many kinds of international certification systems, the matters regarding safety management of test rooms are being regarded as important. Since the blood test rooms of nuclear medicine are exposed to many harmful factors such as infection from clinical specimen and radioactive isotope reagent, there is a need to pay lots of attention to the safety management of staff and patients. Therefore, this study discusses safety management activities of staff and patients, which are conducted in the blood test rooms of the nuclear medicine department in Asan Medical Center. Materials and Methods: In the blood test rooms of the nuclear medicine department in Asan Medical Center, the matters regarding comprehensive safety management by the person in charge of safety management are offered and all staff members of the test rooms apply them into work. Safety management education is regularly conducted according to established regulations, and infection is prevented through implementation of wearing personal protectors and hand sanitation during test work. In addition, technical safety guides and accident guides for interruption of electric power are provided against emergencies. Through infection management guides, infection prevention and preparation methods for infection are learned and radioactive isotope management, safety management about reagent use and safety guides about harmful chemical substances are being applied to work. Results: The blood test rooms of the nuclear medicine department apply safety management regulations to work. Under the situation where hand sanitation should be conducted, hands are washed to prevent infection between staff and patients, and for preventing infection from clinical specimen, personal protectors are worn. The reagent, which is classified as harmful substance, is separately stored to be easily recognized, radioactive wastes and general medical wastes are also safely managed. Through these lots of safety management activities, safety management awareness of staff members is enhanced, and patients are protected from many dangers. Conclusion: Staff members of the blood test rooms of the nuclear medicine department should be fully aware of safety management regulations and apply them to work. When better safety management suggestions are made, they need to be examined and applied for increasing quality of safety management for staff and patients.

  • PDF

A Study on Coagulation and Ozone Treatment of Nonbiodegradable Substances in Landfill Leachate (생물학적 난분해성물질을 함유한 매립장 침출수의 응집 및 오존처리에 관한 연구)

  • Kim, Jong Shik;Choi, Joon Ho
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.330-335
    • /
    • 1998
  • The objectives of this study are summarized with two. The one is to remove of $COD_{Cr}$, color and turbidity with coagulation and ozonation in nonbiodegradable landfill leachate, the other is to compare of water qualities with pre-ozonation and post-ozonation. The results are summarized as follows ; 1) 90 minutes ozonation with $75mgO_3/min$($4.5gO_3/hr$) was conducted at pH 4,7, 10 to remove $COD_{Cr}$. Removal efficiencies were investigated with 48.2%, 52.6%, and 62.3% respectively. As increasing pH, $COD_{Cr}$ removal efficiencies were increased, it was considered that hydroxyl radical($OH{\cdot}$) which strongly oxdize and nonselectively react with organic compounds, was rapidly produced by ozone self-decomposition at high pH. 2) Alum, ferric chloride and ferrous sulfate were used for coagulation as inorganic coagulant. Ferric chloride was investigated with optimal coagulant, and it removed $COD_{Cr}$ about 12.0% at pH5 and dosage of $2,000m{\ell}/{\ell}$. Cation(C-101P), anion(A-601P) and nonion(SC-050) were tested to remove organic pollutants in landfill leachate. Cation(C-101P) was investigated with the most effective organic coagulant, and removal efficiency of $COD_{Cr}$ was 19.8% at pH5 and dosage of $100m{\ell}/{\ell}$. 3) Color and turbidity were removed up to 88.6%, 97.0% at pH10, when contacted 90 minutes with ozone, respectively. These removal efficiencies were much higher than those of $COD_{Cr}$ and $COD_{Mn}$. It was considered that ozone could oxdize the triggering materials of color and turbidity selectively and preferentially. 4) $COD_{Cr}$, color and turbidity were more effectively removed with pre-ozonation than post-ozonation about 8%, 3.5% and 1% respectively. These results were well corresponed with other's studies that pre-ozonation will increase the effect of coagulation.

  • PDF

Difference in Physiological Responses to Environmental Stress in Protox Inhibitor Herbicide-Resistant Transgenic Rice and Non-transgenic Rice (Protox 저해형 제초제 저항성 형질전환벼와 비형질전환벼의 환경스트레스에 대한 생리적 반응 차이)

  • Yun, Young-Beom;Kwon, Oh-Do;Shin, Dong-Young;Hyun, Kyu-Hwan;Lee, Do-Jin;Jung, Ha-Il;Kuk, Yong-In
    • Korean Journal of Weed Science
    • /
    • v.32 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • The objective of this research was to confirm the difference in physiological responses to environmental stresses such as chilling, high temperature, NaCl, and chemical stress (paraquat) in Protox inhibitor resistant-transgenic rice (MX, PX, and AP37) and its non-transgenic counterpart (WT). Transgenic and non-transgenic rice plants were exposed to a chilling temperature of $5^{\circ}C$ for 1 day or a high temperature of $45^{\circ}C$ for 4 days and allowed to recover at $25^{\circ}C$ for 6 days after the chilling treatment or 8 days after the high temperature treatment. Leaf injury, shoot fresh weight, porphyrin biosynthesis substances, and chlorophyll content were investigated in transgenic and non-transgenic rice at 6 days after 0.5% and 1% NaCl treatments or at 5 days after 0~300 ${\mu}M$ paraquat treatments. No significant difference in leaf injury and shoot fresh weight were observed between transgenic and non-transgenic rice during chilling and recovery. Plant height and shoot fresh weight were also similar between transgenic and non-transgenic rice during the high temperature and recovery period (0~5 days). However, plant height and shoot fresh weight in transgenic rice line MX and PX were lower than in non-transgenic rice at 6 days for recovery. Leaf injury, chlorophyll, and Mg-Proto IX ME contents had no significant difference between transgenic rice and non-transgenic rice after NaCl treatment, but Proto IX content for AP37 and shoot fresh weight for PX and AP37 in 0.5% NaCl treatment were significantly reduced compared with non-transgenic rice. There was no difference in leaf injury and shoot fresh weight when comparing transgenic rice and non-transgenic rice after paraquat treatment. Although transgenic rice and non-transgenic rice showed a little difference at a particular measurement period in certain environmental stresses, there was generally no difference in physiological responses between transgenic rice and non-transgenic rice.