• Title/Summary/Keyword: Chemical reactions

Search Result 2,729, Processing Time 0.03 seconds

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

Cation Exchange Capacities, Swelling, and Solubility of Clay Minerals in Acidic Solutions : A Literature Review

  • Park, Won Choon
    • Economic and Environmental Geology
    • /
    • v.12 no.1
    • /
    • pp.41-49
    • /
    • 1979
  • A literature review is made on the physical and chemical characteristics of clay minerals in acidic solutions from the mineralogical and hydrometallurgical viewpoints. Some of the important characteristics of clays are their ability to cation exchange, swelling, and incongruent dissolution in acidic solutions. Various clay minerals can take up metallic ions from solution via cation exchange mechanism. Generally, cation exchange capacity increases in the following order : kaolinite, halloysite, illite, vermiculite, and montmorillonite. In acidic solutions, the cation uptake such as copper by clay minerals is strongly inhibited by hydrogen and aluminum ions and thus is not economically significant factor for recovery of metals such as uranium and copper. In acidic solutions, the cation uptake is substial. Swelling is minimal at lower pH, possibly due to lattice collapse. Swelling may be controllable with montmorillonite type clays by exchanging interlayer sodium with lithium and/or hydroxylated aluminum species. The effect of add on clay minerals are : 1. Division of aggregates into smaller plates with increase in surface area and porosity. 2. Clay-acid reactions occur in the following order: (i) $H^+$ replacement of interlayer cations, (ii) removal of octahedral cations, such as Al, Fe, and Mg, and (iii) removal of tetrahedral Al ions. Acid attack initiates, around the edges of the clay particles and continued inward, leaving hydrated silica gel residue around the edges. 3. Reaction rates of (ii) and (iii) are pseudo-1st order and proportional to acid concentration. Rate doubles for every temperature increment of $10^{\circ}C$. Implications in in-situ leaching of copper or uranium with acid are : 1. Over the life span of the operation for a year or more, clays attacked by acid will leave silica gel. If such gel covers the surface of valuable mineral surfaces being leached, recovery could be substantially delayed. 2. For a copper deposit containing 0.5% each of clay minerals and recoverable copper, the added cost due to clay-acid reaction is about 1.5c/lb of copper (or 0.93 lbs of $H_2SO_4/1b$ of copper). This acid consumption by clay may be a factor for economic evaluation of in-situ leaching of an oxide copper deposit.

  • PDF

Monitoring Ground-level SO2 Concentrations Based on a Stacking Ensemble Approach Using Satellite Data and Numerical Models (위성 자료와 수치모델 자료를 활용한 스태킹 앙상블 기반 SO2 지상농도 추정)

  • Choi, Hyunyoung;Kang, Yoojin;Im, Jungho;Shin, Minso;Park, Seohui;Kim, Sang-Min
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_3
    • /
    • pp.1053-1066
    • /
    • 2020
  • Sulfur dioxide (SO2) is primarily released through industrial, residential, and transportation activities, and creates secondary air pollutants through chemical reactions in the atmosphere. Long-term exposure to SO2 can result in a negative effect on the human body causing respiratory or cardiovascular disease, which makes the effective and continuous monitoring of SO2 crucial. In South Korea, SO2 monitoring at ground stations has been performed, but this does not provide spatially continuous information of SO2 concentrations. Thus, this research estimated spatially continuous ground-level SO2 concentrations at 1 km resolution over South Korea through the synergistic use of satellite data and numerical models. A stacking ensemble approach, fusing multiple machine learning algorithms at two levels (i.e., base and meta), was adopted for ground-level SO2 estimation using data from January 2015 to April 2019. Random forest and extreme gradient boosting were used as based models and multiple linear regression was adopted for the meta-model. The cross-validation results showed that the meta-model produced the improved performance by 25% compared to the base models, resulting in the correlation coefficient of 0.48 and root-mean-square-error of 0.0032 ppm. In addition, the temporal transferability of the approach was evaluated for one-year data which were not used in the model development. The spatial distribution of ground-level SO2 concentrations based on the proposed model agreed with the general seasonality of SO2 and the temporal patterns of emission sources.

Development of Mixed-bed Ion Exchange Resin Capsule for Water Quality Monitoring (수질 중 질소와 인 모니터링을 위한 혼합이온교환수지 캡슐의 개발)

  • Park, Chang-Jin;Kim, Dong-Kuk;Ok, Yong-Sik;Ryu, Kyung-Ryul;Lee, Ju-Young;Zhang, Yong-Seon;Yang, Jae-E
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.344-350
    • /
    • 2004
  • This study was conducted to develop and assess the applicability of mixed-bed ion exchange resin capsules for water quality monitoring in small agricultural watershed. Recoveries of resin capsules for inorganic N and P ranged from 96 to 102%. The net activation energies and pseudo-thermodynamic parameters, such as ${\Delta}G^{o\ddag},\;{\Delta}H^{o\ddag},\;and\;{\Delta}S^{o\ddag}$ for ion adsorption by resin capsules, exhibited relatively low values, indicating the process might be governed by chemical reactions such as diffusion. However, those values increased with temperature coinciding with the theory. The reaction reached pseudo-equilibrium within 24 hours for $NH_4-N\;and\;NO_3-N$, and only 8 hours for $PO_4-P$, respectively. The selectivity of resin capsules were in the order of $NO_3\;^-\;>\;NH_4\;^+\;>\;PO_4\;^{3-}$, coinciding with that of encapsulated Amberlite IRN-150 resin. At the initial state of equilibrium, the resin adsorption quantity was linearly proportional to the mass of ions in the streams, but the rate of movement leveled off, following Langmuir-type sorption isotherm. The overall results demonstrated that the resin capsule system was suitable for water quality monitoring in small agricultural watershed, judging from the reaction mechanism(s) of the resin capsule and the significance of model in field calibration.

Adsorption of Arsenic on Goethite (침철석(goethite)과 비소의 흡착반응)

  • Kim, Soon-Oh;Lee, Woo-Chun;Jeong, Hyeon-Su;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.177-189
    • /
    • 2009
  • Iron (oxyhydr)oxides commonly form as secondary minerals of high reactivity and large surface area resulting from alteration and weathering of primary minerals, and they are efficient sorbents for inorganic and organic contaminants. Accordingly, they have a great potential in industrial applications and are also of substantial interest in environmental sciences. Goethite (${\alpha}$-FeOOH) is one of the most ubiquitous and stable forms of iron (oxyhydr)oxides in terrestrial soils, sediments, and ore deposits, as well as a common weathering product in rocks of all types. This study focused on adsorption reaction as a main mechanism in scavenging arsenic using goethite. Goethite was synthesized in the laboratory to get high purity, and a variety of mineralogical and physicochemical features of goethite were measured and related to adsorption characteristics of arsenic. To compare differences in adsorption reactions between arsenic species, in addition, a variety of experiments to acquire adsorption isotherm, adsorption edges, and adsorption kinetics were accomplished. The point of zero charge (PZC) of the laboratory-synthesized goethite was measured to be 7.6, which value seems to be relatively higher, compared to those of other iron (oxyhydr)oxides. Its specific surface area appeared to be $29.2\;m^2/g$ and it is relatively smaller than those of other (oxyhydr)oxides. As a result, it was speculated that goethite shows a smaller adsorption capacity. It is likely that the affinity of goethite is much more larger for As(III) (arsenite) than for As(V) (arsenate), because As(III) was observed to be much more adsorbed on goethite than As(V) in equivalent pH conditions. When the adsorption of each arsenic species onto goethite was characterized in various of pH, the adsorption of As(III) was largest in neutral pH range (7.0~9.0) and decreased in both acidic and alkaline pH conditions. In the case of As(V), the adsorption appeared to be highest in the lowest pH condition, and then decreased with an increase of pH. This peculiarity of arsenic adsorption onto goethite might be caused by macroscopic electrostatic interactions due to variation in chemical speciation of arsenic and surface charge of goethite, and also it is significantly affected by change in pH. Parabolic diffusion model was adequate to effectively evaluate arsenic adsorption on goethite, and the regression results show that the kinetic constant of As(V) is larger than that of As(III).

Investigation on Characteristics of High PM2.5 Pollution Occurred during October 2015 in Gwangju (광주 지역에서 2015년 10월에 발생한 PM2.5 고농도 사례 특성 분석)

  • Yu, Geun-Hye;Park, Seung-Shik;Jung, Sun A;Jo, Mi Ra;Lim, Yong Jae;Shin, Hye Jung;Lee, Sang Bo;Ghim, Young Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.567-587
    • /
    • 2018
  • A severe haze event occurred in October 2015 in Gwangju, Korea. In this study, the driving chemical species and the formation mechanisms of $PM_{2.5}$ pollution were investigated to better understand the haze event. Hourly concentrations of $PM_{2.5}$, organic and elemental carbon, water-soluble ions, and elemental constituents were measured at the air quality intensive monitoring station in Gwangju. The haze event occurred was attributed to a significant contribution (72.3%) of secondary inorganic species concentration to the $PM_{2.5}$, along with the contribution of organic aerosols that were strongly attributed to traffic emissions over the study site. MODIS images, weather charts, and air mass backward trajectories supported the significant impact of long-range transportation (LTP) of aerosol particles from northeastern China on haze formation over Gwangju in October 2015. The driving factor for the haze formation was stagnant atmospheric flows around the Korean peninsula, and high relative humidity (RH) promoted the haze formation at the site. Under the high RH conditions, $SO{_4}^{2-}$ and $NO_3{^-}$ were mainly produced through the heterogenous aqueous-phase reactions of $SO_2$ and $NO_2$, respectively. Moreover, hourly $O_3$ concentration during the study period was highly elevated, with hourly peaks ranging from 79 to 95ppb, suggesting that photochemical reaction was a possible formation process of secondary aerosols. Over the $PM_{2.5}$ pollution, behavior and formation of secondary ionic species varied with the difference in the impact of LTP. Prior to October 19 when the influence of LTP was low, increasing rate in $NO_3{^-}$ was greater than that in $NO_2$, but both $SO_2$ and $SO{_4}^{2-}$ had similar increasing rates. While, after October 20 when the impact of haze by LTP was significant, $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations increased significantly more than their gaseous precursors, but with greater increasing rate of $NO_3{^-}$. These results suggest the enhanced secondary transformation of $SO_2$ and $NO_2$ during the haze event. Overall, the result from the study suggests that control of anthropogenic combustion sources including vehicle emissions is needed to reduce the high levels of nitrogen oxide and $NO_3{^-}$ and the high $PM_{2.5}$ pollution occurred over fall season in Gwangju.

Effect of Phenolic Mediators and Humic Acid on the Removal of 1-Indanone Using Manganese Oxide (망간산화물(Birnessite)을 이용한 1- Indanone 제거 시 페놀계 반응매개체와 휴믹산(HA) 영향 평가)

  • Choi, Chan-Kyu;Eom, Won-Suk;Shin, Hyun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.445-453
    • /
    • 2012
  • An investigation for removal of 1-indanone (1-ID), which were commonly produced from the biological and/or chemical treatment and natural weathering of the PAHs-contaminated soils, via oxidative transformation mediated by birnessite in the presence of various phenolic mediators is described. This study also examines the potential effect of the natural occurring substance humic acid (HA) on the oxidative transformation. The experiment was carried out in aqueous phase as a batch test (10 mg/L 1-ID, 0.3 mM phenolic mediators, $1.0g/L\;{\delta}-MnO_2$, at pH 5). All of the 11 tested phenoilic mediators belong to the group of natural occurring phenols and are widely used as model constituents of humic substances. From the results of HPLC analysis, it is demonstrated that 1-ID was not reactive to birnessite itself, but it can be effectively removed in birnessite-mediated cross coupling reactions in the presence of the phenolic mediators. The percent removals of 1-ID after 2 day incubation were ranged from 9.2 to 71.2% depending on the phenolic mediators applied. The initial rate constant ($K_{int}$, $hr^{-1}$) values for the 1-ID removals obtained from the pseudo-first-order kinetic plots also widely ranged from 0.18 to 15.0. Results of the correlative analysis between the removal efficiencies and structural characteristics of phenolic mediators indicate that the transformation of the 1-ID was considerably enhanced by the addition of electron-donating substituents (e.g., -OH, $-OCH_3$) at the benzne ring, and much less enhanced by the addition of electron-withdrawing substituents (e.g., -COOH, -CHO). The presence of HA showed that removal efficiencies of 1-ID in the birnessite-phenolic mediator systems decreased with increasing HA concentrations. However at low concentration of HA (< 2 mg/L), it caused some enhancement in the removals of 1-ID as compared to the control.

Bacteriological and Physiochemical Water Quality of Seawater in Tongyeong Harbor, Korea (통영항 해수의 세균학적 및 이화학적 수질)

  • CHOI Jong-Duck;JEOWG Woo-Geon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.611-616
    • /
    • 2001
  • The bacteriological and physiochemical analysis of seawater in Tongyeong harbor was conducted to evaluate sanitary conditions, The samples were collected at 6 stations established once a month from January to December, 2000. During the study period, the ranges of temperature, transparency, chemical oxygen demand, dissolved oxygen, dissolved nitrogen, phosphate and chlorophyll-a were $6.8\sim25.2^{\circ}C,\;1.0\sim2.5\;m,\;1.79\sim2.41\;mg/L,\;5.7\sim10.1\;mg/L,\;6.59\sim10.53{\mu}g-at/L,\;0.56\sim1.01{\mu}g-at/L\;and\;1.21\sim9.54\;mg/m^3$, respectively, The viable cell counts of seawater in Tongyeong harbor ranged from $3.0\times10^4CFU/mL\;to\;6.9\times10^6CFU/mL$. The coliform group and fecal coliform MPN's of the samples were ranged $23\~4,600\;MPN/100\;mL$ (means 540 MPN/100 mL) and $11\~1,600\;MPN/100\;mL$ (means 210 MPN/100 mL), respectively, The coliform group was classified with IMViC reactions and pathogenic vibrios were analyzed. Two hundred eighteen strains that were obtained from seawater samples in Tongyeong harbor represented Escherichia coli group, $66.1\%$; Citrobacter freundii group, $11.0\%$; Enterobacter aerogenes, $9.6\%$; and unknown, $13.3\%$, respectively. During the study period, infectious bacteria such as Vibrio cholerae O1, Salmonella sp. and Shigella sp. were not detected from the samples, but detection ratios of V. parahaemolyticus, V cholerae non-O1 and V. vulnificus were $10.0\sim30.1\%$.

  • PDF

Evaluation of Nutrients Removal using Pyrolyzed Oyster Shells (소성온도에 따른 굴 패각의 영양염 제거 성능 평가)

  • Jeong, Ilwon;Woo, Hee-eun;Lee, In-Cheol;Kim, Jinsoo;Kim, Kyunghoi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.906-913
    • /
    • 2019
  • To evaluate the removal performance of PO4-P and NH3-N, laboratory experiments were conducted by filling a container with oyster shells, pyrolyzed at 100℃ (POS100), 600℃ (POS600) and 800℃ (POS800), and passing artificial wastewaters through the container. The pH in the ef luent was found to increase due to CaO eluted from oyster shell. Removal amounts of PO4-P of ~23.1 mg/kg, 16.1 mg/kg, and 15.9 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used; therefore, the highest PO4-P removal amount was obtained when POS100 was used. It is considered that Ca and dolomite in the oyster shells adsorbed and precipitated PO4-P. Removal amounts of NH3-N were of ~3.56 mg/kg, 5.72 mg/kg, and 3.97 mg/kg were obtained when POS100, POS600, and POS800, respectively, were used The low removal rate for NH3-N is probably due to unstable nitrification, use of sealed containers, and the effect of NH3-N being converted to NH4+ upon increasing pH. Based on these results, pyrolyzed oyster shell is expected to promote changes in PO4-P and NH3-N concentrations through chemical reactions. These results can also be used for basic research in the development of wastewater treatment.

Detection of Spoilage Odors in Beef Using R-index and Pseudomonas Growth during Storage (쇠고기의 저장 중 R-index에 의한 부패취 발생시점과 Pseudomonas의 증식과의 비교 분석)

  • Byeon, Ko Eun;Park, Han Jo;An, Soo Rim;Hong, Kwang Won;Min, Sang Gi;Chung, Ku Young;Won, Kee Hoon;Lee, Seung Ju
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.117-121
    • /
    • 2009
  • Detection of spoilage odors from beef during storage was investigated using sensory evaluation with R-index, and microbial assay for Pseudomonas. Beef samples were tested to measure the flavor changes, which were converted to R-index, and the Pseudomonas levels during storage. There was a steep rise in R-index until 36 hr after storage at 25$^{\circ}C$, and then a gentle rise from 48 hr, whereas, there was a steady rise in R-index in the whole range of storage at 5$^{\circ}C$. Detection time of spoilage odors according to R-index was statistically analyzed at $\alpha$=5% to be at 30.92${\pm}$3.47 hr and 169.80${\pm}$11.27 hr for 25 and 5$^{\circ}C$ storage, respectively, and analyzed at $\alpha$=1% to be 34.80${\pm}$4.01 and 176.41${\pm}$9.89 hr for 25 and 5$^{\circ}C$ storage, respectively. At the detection times of spoilage odors, the Pseudomonas levels were found to be almost the same, but less than 6-7 log CFU/g generally known as a standard level at occurrence of spoilage odors in beef. This indicated that some other factors than the Pseudomonas reactions could be associated with generation of spoilage odors.