• Title/Summary/Keyword: Chemical derivatization

Search Result 80, Processing Time 0.027 seconds

Comparison of isoButoxycarbonyl derivatives, tert.-butyldimethylsilyl derivatives, with US EPA Method in the sensitivity of Alkylphenols, Chlorophenols, and Bisphenol A Potential field-screening applications of GC/MS-SIM (기체 크로마토그래피/질량분석기를 이용한 field-screening 적용을 위한 알킬페놀류, 클로로페놀류 및 비스페놀 A의 isoBOC 유도체, TBDMS 유도체와 US EPA 방법의 비교)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.196-213
    • /
    • 2002
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode followed by three work-up methods for comparison; EPA method, isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in water samples were extracted with dichloromethane. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1~109.9% (EPA method) and 90.3~126.6% (isoBOC derivatization and TBDMS derivatization), respectively. The method detection limit of bisphenol A for SIM were 0.732 ${\mu}g/{\ell}$ (EPA method), 0.002 ${\mu}g/{\ell}$ (isoBOC derivatization) and 0.021 ${\mu}g/{\ell}$ (TBDMS derivatization). The SIM responses were linear with the correlation coefficient varying 0.9755~0.9981 (isoBOC derivatization), and 0.9908~0.9996 (TBDMS derivatization). When these methods were applied to treated wastewater sample from a polyethylene plant, the concentrations of 11 phenols were below the method detection limit.

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Papers Materials

  • Kim, Hyub;Kim, Jin-Ho;Kim, Yong-Hwa
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.120.2-121
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. (omitted)

  • PDF

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.26 no.9
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

EFFECT OF ARGON AND OXYGEN PLASMAS ON VARIOUS POLYETHYLENE SHEETS

  • Chen, Yashao;Hirayama, Naoki;Gomi, Masaki;Kiuchi, Kenji;Momose, Yoshihiro
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.344-350
    • /
    • 1999
  • The surface chemical structure of three kinds of polyethylene (PE): high density (HD) PE, low density (LD) PE and linear (L)-LDPE exposed to Ar and $O_2$ plasmas has been investigated using XPS. Oxygen was incorporated in a more increased amount for HDPE than for L-LDPE and LDPE. Ar plasma tended to incorporate more oxygen than $O_2$ plasma. The XPS valence band spectra for Ar plasma exhibited a clear peak assigned to $O_2$s character. By chemical derivatization method it was found that the amount of -COOH group at the surface was much greater than that of -OH group. The hydrophilic nature of plasma-treated PE increased in the order: LDPE

  • PDF

Determination of phenols in water by derivatization and GC/MS (유도체화와 GC/MS를 이용한 물중의 페놀류 분석)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.453-459
    • /
    • 2005
  • Phenol compounds in water were simultaneously analyzed by extractive derivatization. Aqueous solution was controlled to pH 13 with sodium hydroxide, and then $500{\mu}L$ of benzoyl chloride was added to the solution. The solution was shaken for 15 minutes and extracted with diethyl ether and then analyzed using GC/MS-SIM. The calibration curves of phenolic compounds in the range of 0.05 to $5.0{\mu}g/mL$ showed a good linearity having the correlation coefficient of $r^2=0.9915$ and standard deviation of ${\leq}8.5%$, respectively. The recoveries by this method ware 58.4-114.0%.

MALDI-MS-Based Quantitative Analysis of Bioactive Forms of Vitamin D in Biological Samples

  • Ahn, Da-Hee;Kim, Hee-jin;Kim, Seong-Min;Jo, Sung-Hyun;Jeong, Jae-Hyun;Kim, Yun-Gon
    • Korean Chemical Engineering Research
    • /
    • v.58 no.1
    • /
    • pp.106-112
    • /
    • 2020
  • Analyzing vitamin D levels is important for monitoring health conditions because vitamin D deficiency is associated with various diseases such as rickets, osteomalacia, cardiovascular disorders and some cancers. However, vitamin D concentration in the blood is very low with optimal level of 75 nmol/L, making quantitative analysis difficult. The objective of this study was to develop a highly sensitive analysis method for vitamin D using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS). 25-hydroxyvitamin D (25(OH)D), which has been used as an indicator of vitamin D metabolites in human biofluids was chemically derivatized using a secosteroid signal enhancing tag (SecoSET) with powerful dienophile and permanent positive charge. The SecoSET-derivatized 25(OH)D provided good linearity (R2 > 0.99) and sensitivity (limit of quantitation: 11.3 fmol). Chemical derivatization of deuterated 25-hydroxyvitamin D3 (d6-25(OH)D3) with SecoSET enabled absolute quantitative analysis using MALDI-MS. The highly sensitive method could be successfully applied into monitoring of quantitative changes of bioactive vitamin D metabolites after treatment with ketoconazole to inhibit 1α-hydroxylase reaction related to vitamin D metabolism in human breast cancer cells. Taken together, we developed a MALDI-MS-based platform that could quantitatively analyze vitamin D metabolites from cell products, blood and other biofluids. This platform may be applied to monitor various diseases associated with vitamin D deficiency such as rickets, osteomalacia and breast cancer.

Fast Determination of Multiple-Reaction Intermediates for Long-Chain Dicarboxylic Acid Biotransformation by Gas Chromatography-Flame Ionization Detector

  • Cho, Yong-Han;Lee, Hye-Jin;Lee, Jung-Eun;Kim, Soo-Jung;Park, Kyungmoon;Lee, Do Yup;Park, Yong-Cheol
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.5
    • /
    • pp.704-708
    • /
    • 2015
  • For the analysis of multiple-reaction intermediates for long-chain dicarboxylic acid biotransformation, simple and reproducible methods of extraction and derivatization were developed on the basis of gas chromatography with flame ionization detector (GC-FID) instead of mass spectrometry. In the derivatization step, change of the ratio of pyridine to MSTFA from 1:3 to 9:1 resulted in higher peak intensity (p = 0.021) and reproducibility (0.6%CV) when analyzing 32 g/l ricinoleic acid (RA). Extraction of RA and ω-hydroxyundec-9-enoic acid with water containing 100 mM Tween 80 showed 90.4-99.9% relative extraction efficiency and 2-7%CV compared with those with hydrophobic ethyl acetate. In conclusion, reduction of the pyridine content and change of the extraction solvent to water with Tween 80 provided compatible derivatization and extraction methods to GC-FID-based analysis of longchain carboxylic acids.

A study on the derivatization technique for tamoxifen metabolites in human urine by gas chromatography/mass spectrometry (기체크로마토그래피/질량분석기를 이용한 인체 내 뇨시료에서의 Tamoxifen 대사체 검출을 위한 유도체화 연구)

  • Kim, Yunje;Lee, Yoonjung
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.322-336
    • /
    • 2004
  • The improved derivatization technique of tamoxifen metabolite in human urine is described for the acylation method that they are substituted by derivatization reagent like acyl anhydride for use of gas chromatography/mass spectrometry. The hydroxyl group of tamoxifen metabolite was derivatized by trifluoroacetic anhydride (TFAA), pentafluoroacetic anhydride (PFPA) and heptaflorobutylic anhydride (HFBA). It was investigated to the gas chromatography/mass spectrometry (GC/MS) technique use negative ion chemical ionization (NCI), positive ion chemical ionization (PCI) and electron impact (EI). In acylation of the metabolites of tamoxifen, the effective reaction temperature and time were shown to be at $50^{\circ}C$ for 30 min. The 4-hydroxytamoxifen, which is known to major metabolite of tamoxifen, was not detected in human urine, whileas the hydroxymethoxytamoxifen was detected. We thought that this result was from the single dose of tamoxifen.