• Title/Summary/Keyword: Chemical derivatization

Search Result 80, Processing Time 0.023 seconds

Chemical Derivatization of Catecholamines for Gas Chromatography-Mass Spectrometry

  • Park, Sun-Young;Kang, Bo-Xin;Li, Quing;Kim, Hoon-Sik;Lee, Jun-Gae;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1497-1504
    • /
    • 2009
  • GC/MS analysis of catecholamines (CAs) in biological sample may produce poor reproducible quantitaion when chemical derivatization is used as the technique to form a volatile derivative. Significant quantities of the side products can be formed from CAs with primary amine during the derivatization reaction under un-optimized conditions. We have tested various chemical derivatization techniques in an attempt to find an optimum derivatization method that will reduce side product formation, enable to separate several catecholamine derivatives in GC chromatogram, and obtain significant improvement of detection sensitivity in GC/MS analysis. Whereas several derivatization techniques such as trimethylsilylation (TMS), trifluoroacylation (TFA), and two step derivatization methods were active, selective derivatization to form O-TMS, N-heptafluorobutylacyl (HFBA) derivative using N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) and N-methyl-bis(heptafluorobutyramide) (MBHFBA) reagents was found to be the most effective method. Moreover, this derivative formed by selective derivatization could provide sufficient sensitivity and peak separation as well as produce higher mass ion as base peak to use selected ion in SIM mode. Calibration curves based on the use of an isotopically labeled internal standard show good linearity over the range assayed, 1 ~ 5000 ng/mL, with correlation coefficients of > 0.996. The detection limits of the method ranged from 0.2 to 5.0 ppb for the different CAs studied. The developed method will be applied to the analysis of various CAs in biological sample, combined with appropriate sample pretreatment.

Derivatization of a-ketoacid for the Analysis of Aminotransferase Reaction Using Mass Spectrometry (질량 분석기를 이용한 트렌스아미나제 반응 분석을 위한 케토산 화학 수식법 개발)

  • Lee Chang Soo;Kim Yun Gon;Kim Eun Mi;Kim Byung Gee
    • KSBB Journal
    • /
    • v.19 no.5
    • /
    • pp.394-398
    • /
    • 2004
  • A derivatization method in mass spectrometry for small molecular analysis was developed to solve the problems of volatility of many analytes, difficult ionization of analytes, and undiscriminating isobaric analytes. This derivatization method, oximation of $\alpha$-ketoacid, in the transaminase reaction leads to change of mass difference between amine reactants and ketoacid products. In addition, regardless of the kinds of ketoacid, the linear relationship between the peak intensity and its concentration (from 1 mM to 10 mM) shows that quantitative analysis of the conversion of the reaction can be executed by the analysis of peak intensity of the corresponding oximated ketoacids. Furthermore, this method can be used for identifying transaminase as well as determining its substrate specificity

Identification of Nandrolone and its Metabolite 5α-Estran-3β, 17α-Diol in Horse Urine after Chemical Derivatization by Liquid Chromatography Tandem Mass Spectrometry

  • Dubey, Saurabh;Beotra, Alka
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.90-97
    • /
    • 2017
  • Androgenic anabolic steroids (AASs) are synthetic derivatives of testosterone with a common structure containing cyclopentanoperhydrophenanthrene nucleus. Their use enhances the muscle building capacity and is beneficial during performance. The AASs are one of the most abused group of substances in horse doping. Liquid chromatography tandem mass spectrometry ($LC/MS^n$) has been successfully applied to the detection of anabolic steroids in biological samples. However, the saturated hydroxysteroids viz: nandrolone, $5{\alpha}-estrane-3{\beta}$, $17{\alpha}-diol$ exhibit lower detection responses in electrospray ionisation (ESI) because of their poor ionisation efficiency. To overcome this limitation pre-column chemical derivatization has been introduced to enhance their detection responses in $LC-ESI-MS^n$ analysis. The aim of present study was to develop a sensitive method for identification and confirmation of nandrolone and its metabolite in horse urine incorporating pre-column derivatization using picolinic acid. The method consists of extraction of targeted steroid conjugates by solid phase extraction (SPE). The eluted steroid conjugates were hydrolysed by methanolysis and free steroids were recovered with liquid-liquid extraction. The resulting steroids were derivatized to form picolinoyl esters and identification was done using LC-ESI-MS/MS in positive ionization mode. The picolinated steroid adduct enhanced the detection levels in comparison to underivatized steroids.

Simultaneous Quantitative Determination of Monosaccharides Including Fructose in Hydrolysates of Yogurt and Orange Juice Products by Derivatization of Monosaccharides with p-Aminobenzoic Acid Ethyl Ester Followed by HPLC

  • Ko, Joung-Ho;Huang, Huazi;Kang, Gyoung-Won;Cheong, Won-Jo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.10
    • /
    • pp.1533-1538
    • /
    • 2005
  • We have determined the contents of monosaccharides in the hydrolysates of some yogurt and orange juice products by derivatizing monosaccharides with p-aminobenzoic acid ethyl ester (ABEE). The separation of the ABEE-derivatized monosaccharides was efficiently carried out by HPLC using a microcolumn packed with the Alltima $C_{18}$ stationary phase. The concentrations of monosaccharides were determined based on the measured peak area/height counts. ABEE derivatization of fructose and its detection have never been successfully carried out before this work. In this study, two peaks were observed in a fixed ratio for ABEE-fructose, and the ratio was maintained over a wide range of fructose concentration. In order to prove the validity of the above method, we compared the concentrations of glucose, galactose and fructose determined by ABEE derivatization and UVD (ultraviolet detector) chromatography with those determined by RID (refractive index detector) chromatography without derivatization. The determined concentrations of monosaccharides obtained from the two chromatographic methods were found close to each other within acceptable error ranges.

Recent Advances in MALDI-MS Based Quantitative Targeted Glycan Analysis (MALDI-MS 기반 당단백질 당쇄의 정량분석 기술 개발 연구 동향)

  • Kim, Kyoung-Jin;Kim, Yoon-Woo;Hwang, Cheol-Hwan;Park, Han-Kyu;Jeong, Jae Hyun;Kim, Yun-Gon
    • KSBB Journal
    • /
    • v.30 no.5
    • /
    • pp.230-238
    • /
    • 2015
  • Abnormal glycosylation can significantly affect the intrinsic functions (i.e., stability and solubility) of proteins and the extrinsic protein interactions with other biomolecules. For example, recombinant glycoprotein therapeutics needs proper glycosylation for optimal drug efficacy. Therefore, there has been a strong demand for rapid, sensitive and high-through-put glycomics tools for real-time monitoring and fast validation of the biotherapeutics glycosylation. Although liquid chromatography tandem mass spectrometry (LC-MS/MS) is one of the most powerful tools for the characterization of glycan structures, it is generally time consuming and requires highly skilled personnel to collect the data and analyze the results. Recently, as an alternative method, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS), which is a fast, robust and easy-to-use instrumentation, has been used for quantitative glycomics with various chemical derivatization techniques. In this review, we highlight the recent advances in MALDI-MS based quantitative glycan analysis according to the chemical derivatization strategies. Moreover, we address the application of MALDI-MS for high-throughput glycan analysis in many fields of clinical and biochemical engineering.

Simultaneous Gas Chromatography-Mass Spectrometric Determination of Total and Individual Phthalic Esters Utilizing Alkaline Hydrolysis and Silyl Derivatization Technique

  • Kim, Min-Seon;Li, Dong-Hao;Shim, Won-Joon;Oh, Jae-Ryoung;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.432-438
    • /
    • 2007
  • Environmentally important phthalic esters have been analyzed by GC-MS in terms of individual phthalic esters or total phthalic esters directly or after derivatization. Derivatization improves the chromatographic characteristics of the highly polar phthalic esters. This study focused on the GC-MS determination of the total phthalic esters and the individual phthalic esters simultaneously. The phthalic esters were hydrolyzed to phthalate and corresponding alcohols in 1 M NaOH solution at 90 oC for 30 min followed by extraction with ethyl acetate after acidifcation. The phthalic acid and alcohols were simultaneously silyl derivatized using bis(trimethylsilyl)trifluoroacetamide (BSTFA) to their corresponding silyl ester and ethers in the mixture of 60% acetone and 40% ethyl acetate at room temperature within 30 min. Because of the high reactivity of BSTFA with the phthalic acid and alcohols effective silyl derivatization was possible simultaneously. GC-MS analysis of the silyl derivatives of phthalic acid and alcohols was performed. The total phthalic ester content was estimated from the analytical result of phthalic silyl ester, while the individual phthalic ester was quantified from the analytical results of alcoholic silyl ethers. This technique was applied to spiked tab water and real seawater samples from the Lake Shihwa in Korea. The results were checked against the results from the direct GC-MS analysis of the phthalic esters and reasonable recoveries with high sensitivity were achieved. The recoveries were higher than 75% with low relative standard deviation (below 10%).