• Title/Summary/Keyword: Checking Errors

Search Result 148, Processing Time 0.024 seconds

Software Implementation of Welding Bead Defect Detection using Sensor and Image Data (센서 및 영상데이터를 이용한 용접 비드 불량검사 소프트웨어 구현)

  • Lee, Jae Eun;Kim, Young-Bong;Kim, Jong-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.185-192
    • /
    • 2021
  • Various methods have been proposed to determine the defect detection of welding bead, and recently sensor data and image data inspection have been steadily announced. There are advantages that sensor data inspection is highly accurate, and two-dimensional-based image data inspection is able to determine the position of the welding bead. However, when analyzing only with sensor data, it is difficult to determine whether the welding has been performed at the correct position. On the other hand, the image data inspection does not have high accuracy due to noise and measurement errors. In this paper, we propose a method that can complement the shortcomings of each inspection method and increase its advantages to improve accuracy and speed up inspection by fusing sensor data inspection which are average current, average volt, and mixed gas data, and image data inspection methods and is implemented as software. In addition, it is intended to allow users to conveniently and intuitively analyze and grasp the results by performing analysis using a graphical user interface(GUI) and checking the data and inspection results used for the inspection. Sensor inspection is performed using the characteristics of each sensor data, and image data is inspected by applying a morphology geodesic active contour algorithm. The experimental results showed 98% accuracy, and when performing the inspection on the four image data, and sensor data the inspection time was about 1.9 seconds, indicating the performance of software that can be used as a real-time inspector in the welding process.

Development of Graph based Deep Learning methods for Enhancing the Semantic Integrity of Spaces in BIM Models (BIM 모델 내 공간의 시멘틱 무결성 검증을 위한 그래프 기반 딥러닝 모델 구축에 관한 연구)

  • Lee, Wonbok;Kim, Sihyun;Yu, Youngsu;Koo, Bonsang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.3
    • /
    • pp.45-55
    • /
    • 2022
  • BIM models allow building spaces to be instantiated and recognized as unique objects independently of model elements. These instantiated spaces provide the required semantics that can be leveraged for building code checking, energy analysis, and evacuation route analysis. However, theses spaces or rooms need to be designated manually, which in practice, lead to errors and omissions. Thus, most BIM models today does not guarantee the semantic integrity of space designations, limiting their potential applicability. Recent studies have explored ways to automate space allocation in BIM models using artificial intelligence algorithms, but they are limited in their scope and relatively low classification accuracy. This study explored the use of Graph Convolutional Networks, an algorithm exclusively tailored for graph data structures. The goal was to utilize not only geometry information but also the semantic relational data between spaces and elements in the BIM model. Results of the study confirmed that the accuracy was improved by about 8% compared to algorithms that only used geometric distinctions of the individual spaces.

Study on the Plan to Reduce the EVENT of the Gas Regulator (정압기 EVENT 감소방안 연구)

  • Kang-ok Yun;Tae-jun Eom;Ki-beom Kim;Yong-woo Lee;Hyoung-Min Lee;Byeong-Geun Gong
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • The Gas Regulator EVENT is a signal sent by the Remote Terminal Unit(RTU) installed in each local gas regulator (hereinafter referred to as "regulator"), and is an abnormal alarm that can be intuitively checked in our client server. This is an important data that enables immediate dispatch order and initial action in the situation room when a regolator abnormality occurs, and can analyze the cause of the regulator abnormality. Looking at the trend of EVENT data for regulator over the past three years, there is a clear trend of increasing unchecked EVENT data. The increase in non-checking event (actual abnormality or noise event) may mean that firstly, mechanical or pressure abnormality occurs in the actual regulator, and secondly, there is no abnormality in the actual regulator, but communication error occurred in the RTU, reset. EVENT Data may be formed as if an abnormality occurred in the static voltage due to an error, sensor error, power failure (instantaneous power failure), etc. Among them, this study analyzed the recently generated unchecked EVENT data to identify critical noise events among RTU errors, which are noise events, and reviewed ways to increase the reliability of Regulator EVENTs by reducing them.

The Psychological Structure and Characteristic of Hasteful Behaviors: Understanding the Relation between Hasteful Behaviors, Omission of Checking and Achievement Striving (서두름 행동의 심리적 구조 및 특성 파악: 서두름 행동, 확인생략행동, 성취욕구 간의 관계 이해)

  • Soon Chul Lee;Sun Jin Park
    • Korean Journal of Culture and Social Issue
    • /
    • v.14 no.2
    • /
    • pp.63-81
    • /
    • 2008
  • Hasteful behavior means choosing the best suited methods while behaving fast and quickly. We can't conclude whether hasteful behavior is totally bad or good. Striving for achievement of own certain purpose reflects achievement motivation or need for achievement. However, this striving also has potentiality of missing confirmation, therefore the potentiality may cause errors. The aim of this study is to investigate the psychological structure and characteristic of the hasteful behavior. One hundred ninety-one students conducted Hasteful Behavior Questionnaire, Achievement Motivation Measuring Scale, and NEO Personality Inventory. We analyzed data of 188 respondents, because of missing value. The result of factor analysis showed that hasteful behavior consisted of 5 factors- 「Uncomfortableness」, 「Time Pressure」, 「Isolation」, 「Boring Condition」, and 「Expecting Rewards」. According to correlations among the hasteful behavior factors and the relationship between hasteful behavior and achievement motivation, we found that hasteful behavior had two aspects, one was "Missing Confirmation(MC)" and the other was "Need for Achievement(NA)". We also found that 「Time Pressure」 was related to the both aspects. MC had a positive relation to Neuroticism, whereas MC correlated negatively with Conscientiousness. On the other hand, NA had a positive relationship with Extraversion and Achievement Striving.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Validation of Satellite SMAP Sea Surface Salinity using Ieodo Ocean Research Station Data (이어도 해양과학기지 자료를 활용한 SMAP 인공위성 염분 검증)

  • Park, Jae-Jin;Park, Kyung-Ae;Kim, Hee-Young;Lee, Eunil;Byun, Do-Seong;Jeong, Kwang-Yeong
    • Journal of the Korean earth science society
    • /
    • v.41 no.5
    • /
    • pp.469-477
    • /
    • 2020
  • Salinity is not only an important variable that determines the density of the ocean but also one of the main parameters representing the global water cycle. Ocean salinity observations have been mainly conducted using ships, Argo floats, and buoys. Since the first satellite salinity was launched in 2009, it is also possible to observe sea surface salinity in the global ocean using satellite salinity data. However, the satellite salinity data contain various errors, it is necessary to validate its accuracy before applying it as research data. In this study, the salinity accuracy between the Soil Moisture Active Passive (SMAP) satellite salinity data and the in-situ salinity data provided by the Ieodo ocean research station was evaluated, and the error characteristics were analyzed from April 2015 to August 2020. As a result, a total of 314 match-up points were produced, and the root mean square error (RMSE) and mean bias of salinity were 1.79 and 0.91 psu, respectively. Overall, the satellite salinity was overestimated compare to the in-situ salinity. Satellite salinity is dependent on various marine environmental factors such as season, sea surface temperature (SST), and wind speed. In summer, the difference between the satellite salinity and the in-situ salinity was less than 0.18 psu. This means that the accuracy of satellite salinity increases at high SST rather than at low SST. This accuracy was affected by the sensitivity of the sensor. Likewise, the error was reduced at wind speeds greater than 5 m s-1. This study suggests that satellite-derived salinity data should be used in coastal areas for limited use by checking if they are suitable for specific research purposes.

Development of Internet Information Push-Delivery System Design of Smoking Cessation for Health Promotion (지역주민의 건강증진을 위한 인터넷 금연 강화 프로그램 개발)

  • Kim, Young-Bok;Shin, Jun-Ho;Kim, Shin-Woel
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.287-301
    • /
    • 2004
  • Objectives: The development of internet programs for smoking cessation was motivated to quit smoking in the large group of smokers. This personalized program consisted of tailored message to consider the smokers characteristics, and contain the informations on the outcomes of smoking cessation and the skills to be used in the quit attempts. The purpose of this study was to develop the internet management program and information push-delivery system for smoking cessation to encourage the personal intention to quit smoking. Methods: We conducted in 3 steps as developing push service to encourage intention of smoking cessation, analyzing problems of smoking cessation program through the pilot test and suggesting improvements by implication stages. Results: This program is delivered for 30 days. if the participants do not fail to quit smoking. The contents consisted of 13 stages which were divided on starting period. practical period, maintenance period and success period. And push service afforded the tailored message to participants using their e-mail. According to the evaluation of pilot test, the problems of internet information push-delivery service for smoking cessation were the over-tasks per visiting time, recording style of participants, difficulty of terms and sentences, lack of visual effects, absence of follow-up module and unsuitable link with main homepage. Improvements were divided on 3 stages by implication period. The first stage included the immediate improvements as improving link with homepage, modifying menu of smoking information and upload file of notice part. The second stage included the short term improvements as alleviating condition of withdrawal, coordinating start stage of retrial, modifying errors of information push-delivery service and addition of educational materials. The third stage included the long term improvements as development of follow-up module, cost-effectiveness evaluation, reducing contents quantity, introduction of checking style, compensation of graphics effect and review for SMS utilization. Conclusions: This program contribute to improving smoking cessation rate. Therefore this program should be tested in a community to evaluate the effectiveness. To promote the effectiveness, this program should be developed the contents and the strategies for various targets, and established the follow-up system for ex-smokers.

  • PDF