• Title/Summary/Keyword: Check system

Search Result 3,301, Processing Time 0.031 seconds

Prototype Design of Medicine Information System to check medicinal misusing (약물 남용 방지를 위한 의약품 정보 시스템의 프로토타입 설계)

  • Kim, Ha-Gang;Oh, Su-Hee;Kim, Nam-Ho;Cha, Byung-Rae
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.448-458
    • /
    • 2009
  • Recently, the Korean Pharmaceutical Association has a public service advertisements for medicinal misusing prevention and environment protection by medicinal substances. And the cost and procedure complexity was increased by specialization of dispensary and medical practice. To overcome this situation, we felt the need of a medicine information system. Ubiquitous and convergence technology have become trends in the IT field. In this research, we designed prototype of medicine information system for management and prevention of medicinal misusing using IT technologies.

  • PDF

A Case Study of a Mobile Hospital Information System Usability (모바일 병원정보시스템 사용성에 대한 실증연구)

  • Ahn, Myong-Jin;Yang, Joon-Young;Ryu, Hyo-Seon;Park, Chan-Seok
    • Korea Journal of Hospital Management
    • /
    • v.18 no.4
    • /
    • pp.97-112
    • /
    • 2013
  • This study is a proposal of quality scale and measurement for the Mobile Hospital Information System Usability used to the Chungnam National University Hospital in Daejeon Korea. This study is to provide decision- making guideline for hospital managers and to provide feedback for the users' information needs in Mobile Hospital Information System. The target people of the study were medical doctors in Chungnam National University Hospital. The service contexts of usability were request of medical Care, Vital sign check of Patient, Care Agreement of Patient, Blood management, Check of care state, Sign of choice doctors, Query of doctor order and patient measurement result. The Usability factors were the efficiency, effectiveness and satisfaction of quality model ISO9241-11. This study shows that the Mobile HIS is used for the communication and education between doctor and patients. Especially, The Care Agreement of Patient is a part of the most utilized in the Mobile HIS.

  • PDF

Development of Section Load Estimation Program for Smart Distribution Management System (스마트배전 운영시스템용 구간부하 추정 프로그램 개발)

  • Yun, Sang-Yun;Chu, Chul-Min;Kwan, Seung-Chul;Song, Il-Keun;Lim, Sung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1083-1090
    • /
    • 2012
  • In this paper, we present the section load estimation program of distribution system for smart distribution management system. The proposed program is composed with three parts. One is the consistency check part for switch measurements which consist a section. The consistency check is divided into the current and angle test. For the current test, we examine the input and output power flow for the switch group. For the angle test, the result of power flow calculation at previous step is used. Another is the voltage estimation part for the measured switches. We use the weighted least square (WLS) method for the voltage estimation. The third is the part of final section load calculation. The database structure for accomplishing the developed estimation program is also proposed. To verify the accuracy of the experimental results, case studies are performed using a actual data of Jeju island. The developed program can be effectively applied to the distribution operation systems.

A Study on the Scheme of Information System Audit for Institute of Knowledge Information (지식정보 관리기관을 위한 정보시스템 감리 추진방안에 관한 연구)

  • Lee, Sang-Jun;Ra, Jong-Hei;Go, Hyung-Dae;Shin, Ki-Jung
    • Journal of Information Technology Services
    • /
    • v.5 no.3
    • /
    • pp.121-135
    • /
    • 2006
  • With the growth and maturation of IT industry, the necessity of audit about development, maintenance and management of high-quality information system is gradually increasing. In addition, the necessity of inner auditing system, which could totally verify and evaluate the effectiveness of project according to the characteristics of organization conducting information-oriented business, also being proposed. Government offices including Korea Institute of Science and Technology(KISTI) collectively controlling nationwide science-technology related information have no guiding principle or organization within themselves even though performing information-oriented businesses are becoming more bigger and complicated. In this paper, we propose scheme for devising framework, which can audit construction and operation of knowledge information, check list and guideline. In addition, we present concrete ways for adapting these schemes to institutes which manage science-technology knowledge information. Audit framework consists of points of time in audit, audit domain and audit criterion. Points of time in audit are defined as three phases as followings: pre-audit, in-progress audit and post-audit. Audit domain includes 16 detail audit domains and especially we set 11 check items and 40 detail investigation items for database implementation business. We expect that management level of science-technology implementation business of organizations using this research result will increase and they could offer high-quality information service.

A Study on the Hydraulic Vibration Characteristics of the Prefill Check Valve (프리필용 체크밸브의 유압진동 특성에 관한 연구)

  • Park, Jeong Woo;Han, Sung-Min;Lee, Hu Seung;Yun, So-Nam
    • Journal of Drive and Control
    • /
    • v.18 no.3
    • /
    • pp.8-15
    • /
    • 2021
  • A rear axle steering (RAS) system is attached to the rear of medium and large commercial vehicles that transport large cargo. The existing RAS systems are driven by electro-hydraulic actuator (EHA), and most commercialized EHAs consist of electric motors, hydraulic pumps, relief valves, prefill valves and cylinders. The prefill valve required for such EHAs is a type of check valve with extremely low cracking pressure that should not allow RAS to have noise or vibration, and the prefill valve prevents system negative pressure as well as unstable operation. Most papers on this topic rely on experiments to predict valve performance, and theoretically detailed modeling of valves or pipelines is performed, but it is very rare to evaluate hydraulic vibration characteristics by analysing everything from hydraulic pumps to valves comprehensively. In this study, we proposed an experimental circuit that can predict the performance of the prefill valve. The study also analysed the pressure-flow pulsation that is transmitted to the valve through the pipeline, and how the transmitted pressure-flow pulsation affects the valve vibration.

The Proposal of System Structure for Using Safe Personal Mobility Devices (안전한 개인형 이동장치 사용을 위한 시스템 구조 제안)

  • Kim, Wantae;Park, Byungjoon;Kim, Hyunsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.3
    • /
    • pp.33-41
    • /
    • 2022
  • Recently the use of personal mobility devices is rapidly increasing, and the businesses related to personal mobility devices are quickly growing as well. Although the use of personal mobility devices provides convenience for short distance movements, many problems occur due to the lack of safety devices and the absence of associated road traffic laws. The number of accidents caused by using personal mobility devices continues increasing every year, and the injuries or deaths are seriously happening with those accidents. When using personal mobility devices, there are basic safety precautions such as wearing a helmet, prohibiting boarding with more than two people, prohibiting boarding with more than 100kg, prohibiting using after drinking alcohol, and so on. However, it is exposed to traffic accidents because there is no way to check before using the system. Therefore, to ensure the user's safety in using the electric kickboard among personal mobility devices, this paper proposes a system that can check the user's safety state before using the electric kickboard. It is possible to safely use personal mobility devices and prevent accidents by proposing a system structure of the electric kickboard that can be used after checking for the use of more than two people, overweight, wearing a helmet, and drinking alcohol.

Health Problem of the Middle-Aged Women (종합 건강검진 과정에서 나타난 일부 중년기 여성의 건강문제)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.258-270
    • /
    • 1999
  • This study was carried out to offer the basic data for more qualitative lives of the middle-aged women through their health maintenance and control. So, the researcher reviewed and analyzed the health problems of the middle-aged women, the differences of main symptoms in each subject, positive ratcs in screening tests, the difference of screening tests with age and the correlation of obesity and blood pressure with screening tests. All subjects were 218 women(40-59years) who had a check-up at a comprehensive health check-up center in K University Hospital in Seoul from July 1, 1998 to August 31. 1998. Questionaires were developed to get subjects, general characteristics. main symptoms, medical examination and diagnosed disease by the researcher referring through the questionaires of comprehensive health check-up center and the medical recorders were used as a tool of study. The researcher analyzed the data with SPSS PC+ ; the distribution of the subjects, general characteristics and main symptoms with percentage : the difference between main symptoms and screening tests with X$^2$-test, ANOVA. The results are as follows. 1) Among the age distribution, most were 40-45 years old and unemployed. 2) The most common complaints were indigestion in digestive system, cough in respiratory system, heart beat in cardiovascular system, general sweat in endocrine system. edema in urinary system, easy bruise in hematologic system, backache in musculoskeletal system, headache in psychoneurologic system, lochia in gynecology, itch in dermatology system, eye ball pain in visual system and tinnitus in auditory system. 3) In main symptoms according to age, the 40-45 age group had a higher rate of complaints in digestive system and gynecology than other age group ; the 46-49 age group in endocrine system. 4) The main symptoms according to diagnosis had no difference statistically. 5) The screening tests which showed high rates of abnormality were mammography(the highest), abdominal ultrasonography, upper gastrointestinal series/gastrofiberscopy, PFT. In all age group the highest rate of abnormality was seen in mammography. 6) In screening tests according to age. the 46-49 age group showed higher positive rates of pap smear, blood sugar test, urine test than any other age group ; the 50-55 age group showerd higher positive rates of obesity, BP, chest X-ray, abdominal ultrasonography, ESR, SGOT, CRP and urine micro. 7) In correlation of obesity with screening test, the obesity group showed higher positive rates of blood pressure, chest X-ray, abdominal ultrasonography, HCT and CRP than the normal weight group. 8) In correlation of blood pressure with screening test, the hypertension group showed higher positive rate of obesity, chest X-ray, abdominal ultrasonography, pap smear and blood sugar than the normal blood pressure group. In conculusion, the middle-aged women have various physical symptoms and affected by age. The obesity and BP have an important effect on the health of the middle aged women. Therefore, this study is considered significant as data for qualitative lives of the middle-aged women playing an important part of family health care by catching of their health problem complaints for prevention of disease and promotion of health.

  • PDF

Development of An Evaluation System for the Interim Check of Integrated Rural Village Development Project (농촌마을종합개발사업 중간 점검을 위한 평가지표 적용사례)

  • Han, Kyung-Soo;Kim, Ki-Hyun;Jun, Teak-Ki;Um, Dae-Ho;Choi, Youn-Sang
    • Journal of Korean Society of Rural Planning
    • /
    • v.13 no.2
    • /
    • pp.121-132
    • /
    • 2007
  • In this study, We developed an evaluation system for the interim check of Integrated Rural Village Development Project and analyzed its applicability to an actual evaluation process through a pilot evaluation on regions selected. The evaluation system consists of documentary assessments(30%) and field inspections(70%). The documentary assessments are quantitative assessments on check-lists reports by self-evaluation prepared by local governments. The field inspections are qualitative assessments by evaluation teams. Sixteen evaluation indices were developed for documentary assessments and seven criteria were designed for field inspections. For a pilot evaluation, one region in each province excluding Jeju Do, eight regions was selected and the field inspections due to circumstances was proceeded in two regions. The results of documentary assessments indicate that most of regions are evaluated low in project performance attributable to the delay in security for sites. In the field inspections, it appears that most of the regions evaluated high at the documentary assessments got a high point from them. They also show that coordination of action plans, rather than quantitative achievements, is a base determining success of the projects.

ACCURACY ASSESSMENT BY REFINING THE RATIONAL POLYNOMIALS COEFFICIENTS(RPCs) OF IKONOS IMAGERY

  • LEE SEUNG-CHAN;JUNG HYUNG-SUP;WON JOONG-SUN
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.344-346
    • /
    • 2004
  • IKONOS 1m satellite imagery is particularly well suited for 3-D feature extraction and 1 :5,000 scale topographic mapping. Because the image line and sample calculated by given RPCs have the error of more than 11m, in order to be able to perform feature extraction and topographic mapping, rational polynomial coefficients(RPCs) camera model that are derived from the very complex IKONOS sensor model to describe the object-image geometry must be refined by several Ground Control Points(GCPs). This paper presents a quantitative evaluation of the geometric accuracy that can be achieved with IKONOS imagery by refining the offset and scaling factors of RPCs using several GCPs. If only two GCPs are available, the offsets and scale factors of image line and sample are updated. If we have more than three GCPs, four parameters of the offsets and scale factors of image line and sample are refined first, and then six parameters of the offsets and scale factors of latitude, longitude and height are updated. The stereo images acquired by IKONOS satellite are tested using six ground points. First, the RPCs model was refined using 2 GCPs and 4 check points acquired by GPS. The results from IKONOS stereo images are reported and these show that the RMSE of check point acquired from left images and right are 1.021m and 1.447m. And then we update the RPCs model using 4 GCPs and 2 check points. The RMSE of geometric accuracy is 0.621 m in left image and 0.816m in right image.

  • PDF

Design and Performance Evaluation of Improved Turbo Equalizer (개선된 터보 등화기의 설계와 성능 평가)

  • An, Changyoung;Ryu, Heung-Gyoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.28-38
    • /
    • 2013
  • In this paper, we propose a improved turbo equalizer which generates a feedback signal through a simple calculation to improve performance in single carrier system with the LMS(least mean square) algorithm based equalizer and LDPC(low density parity check) codes. LDPC codes can approach the Shannon limit performance closely. However, computational complexity of LDPC codes is greatly increased by increasing the repetition of the LDPC codes and using a long parity check matrix in harsh environments. Turbo equalization based on LDPC code is used for improvement of system performance. In this system, there is a disadvantage of very large amount of computation due to the increase of the repetition number. To less down the amount of this complicated calculation, The proposed improved turbo equalizer adjusts the adoptive equalizer after the soft decision and the LDPC code. Through the simulation results, it's confirmed that performance of improved turbo equalizer is close to the SISO-MMSE(soft input soft output minimum mean square error) turbo equalizer based on LDPC code with the smaller amount of calculation.