• Title/Summary/Keyword: Charging Technique

Search Result 134, Processing Time 0.027 seconds

Analysis of Current-Voltage Characteristics Caused by Electron Injection in Metal-Oxide-Semiconductor Devices (전자주입에 의해 야기되는 MOS 소자의 전류-전압 특성 분석)

  • Jeon Hyun-Goo;Choi, Sung-Woo;Ahn, Byung-Chul;Roh, Yong-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.11
    • /
    • pp.25-35
    • /
    • 2000
  • A simple two-terminal cyclic current0voltage(I-V) technique was used to measure the current-transients in metal-oxide-semiconductor capacitors. Distinct charging/discharging currents were measured and analyzed as a function of the hold time, the delay time, the gate polarity during the FNT electron injection, the injection fluence and the annealing time after the injection had stopped. The charge-exchange current was distinguished from total current-transients containing the displacement current components. Charging/discharging current caused by the charge exchange was strongly dependent not only on the density of positive charges in the $SiO_2$, but also on the density of interface traps generated during the FNT electron injection. Several tentative mechanisms were suggested.

  • PDF

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

Understanding the role of hydrogen on creep behaviour of Zircaloy-4 cladding tubes using nanoindentation

  • Suman, Siddharth
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2041-2046
    • /
    • 2020
  • The present article investigates the influence of hydrogen concentration on the creep performance of cold-worked stress-relieved unirradiated Zircaloy-4 cladding tube using nanoindentation technique. The as-received Zircaloy-4 tube is hydrided to the concentrations of 600 ppm and 900 ppm using gaseous hydrogen charging method. Constant load indentation creep tests are performed for a dwell period of 600 s in the temperature range of 300℃-500 ℃ at 1000 μN, 2000 μN, and 3000 μN. The impact of hydrogen is evaluated in terms of steady state power law creep exponent and activation energy. The power law creep exponent decreases with increase in hydrogen concentration, however, it remains fairly constant with increase in temperature up to 500 ℃. Moreover, activation energy too decreases significantly with increase in hydrogen concentration. The mean stress exponent and activation energy are found to be 3.58 and 28.67 kJ/mol, respectively, for as-received sample.

Machining of Micro Grooves using Hybrid Electrochemical Processes with Voltage Pulses (펄스 전기화학 복합가공기술을 적용한 미세 그루브 가공)

  • 이은상;박정우;문영훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.32-39
    • /
    • 2003
  • Pulse electrochemical machining process with high or low current density may produce a non-lustrous surface on workpiece surface. The usual polishing process to remove a black layer from the surface has been hand polish the part. But the milli-to-micro meter scale structure formed by the electrochemical machining process may be destroyed while polishing process. The application of ultra short voltage pulses based on the analysis of electrical double layer charging process allows high resolution electrochemical machining and polishing. This technique was based on the specific polarization resistance from the comparison of ideal and experimental potential variation during short voltage pulses.

Slow Noble Ion - Induced Secondary Electron Emission Characteristics of MgO Layer.

  • Lee, Sang-Kook;Kim, Jae-Hong;Lee, Ji-Hwa;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.221-223
    • /
    • 2002
  • We have measured the secondary electron emission yield ${\gamma}_i$ from MgO films deposited on $SiO_2/Si$ for low energy noble ions. A pulsed ion beam technique was employed in order to suppress the surface charging effect during the measurement. From the measurement of the ion - induced secondary electron emission coefficients ${\gamma}_i$ for 5 noble ions with energies ranging from 50 eV to 225 eV, it was shown that, with increasing the kinetic energies of the incident ions, the ${\gamma}_i$ increased

  • PDF

Surface Relief Holograms on azo-polymer film

  • Yatagai, Toyohiko;Harada, Kenji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.293-296
    • /
    • 2002
  • Surface relief holograms are fabricated by means of irradiation of laser interference patterns. The diffraction efficiency and the surface relief depth depend on the writing energy and the polarization of the writing laser beam. This structure is very stable at temperatures under glass transition temperature $T_g$ and can be erased by heating above $T_g$. We proposed a new technique to control the surface relief structure. The electric charge was deposited on the surface relief grating in a corona-depositing poling setup in an oven. The first-order diffraction efficiency measured before and after corona discharge increased from about 0.24 % to about 28 %. This diffraction efficiency increase is mainly caused by the increase of the relief depth caused by the electric charge. The relief depth is increased from 20 nm to 350 nm by corona charging. .

  • PDF

Fuzzy Algorithm for FDD Technique Development of System Multi-Air Conditioner (퍼지 알고리즘을 이용한 시스템 멀티 에어컨의 고장진단 알고리즘 개발)

  • Choi, C. S.;Tae, S. J.;Kim, H. M.;Cho, K. N.;Moon, J. M.;Kim, J. Y.;Kwon, H. J.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1220-1228
    • /
    • 2005
  • Fault detection and diagnostic (FDD) systems have the potential to reduce equipment downtime, service costs, and utility costs. In this study, model based algorithm and fuzzy algorithm were used to detect and diagnose various fault at System multi-air conditioner. various fault include the Refrigerant Low charging, Fouling of Indoor Heat Exchanger, Fouling of Outdoor Heat Exchanger A experimental verification was conducted in the 6HP System multi-air conditioner on an 8-floor building. Test results showed diagnosis result about 78 $\~$ 90$\%$ for given faults. This Study lays the foundation fur future work on develope the real-time fault detection and diagnosis system for the System multi-air conditioner.

Development of Charging Control Device Using the Intelligent Control Method (지능제어기법에 의한 충전제어 장치의 개발)

  • Kim, Dong-Wan;Hwang, Gi-Hyun;Lee, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.116-119
    • /
    • 2001
  • In this research, we detect the charge state within $0.1{\sim}0.3[A]$ and develop the intelligent digital charge device by applying a fine pulse signal using PWM inverter and Proportional-Integral(PI) controller which uses micro -processor and intelligent technique. The ripple rate is within ${\pm}1%$, and the indicator error rate of full charge state is within ${\pm}1%$, and the voltage stability is within ${\pm}0.1[V]$, and the accuracy of voltage detect is 48[V] and ${\pm}0.5[V]$ in the reference of 100[A].

  • PDF

A study on the safety assessment of Hydrogen refueling system (수소 충전 시스템의 안전성 평가에 관한 연구)

  • Kim, Tae Hun;Oh, Young Dal;Lee, Man Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.167-173
    • /
    • 2014
  • Hydrogen energy is expanding in range for civil use together with development of pollution-free power sources recently, and it is judged that the use of hydrogen will increase more as a part of carbon dioxide reduction measures according to the Climatic Change Convention. Especially, it is thought that the securement of safety of the used dispenser will be the biggest obstacle in the use of high-pressure hydrogen because the hydrogen station is operated in a high pressure. This study found risks in the process and problems on operation by making use of HAZOP(6 kinds), a qualitative safety evaluation technique, and FMEA(5 kinds), a fault mode effect analysis, for the hydrogen charging system at a hydrogen gas station, derived 6 risk factors from HAZOP and 5 risk factors from FMEA, and prepared measures for it.

Battery charging system Using Parallel Operation Control Technique. (병렬운전 제어기법을 적용한 베터리 충전 장치)

  • Yoon, Ju-Houc;Lee, Jong-Hun;Kim, Hong-Min;Ahn, Jin-Woo;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.365-366
    • /
    • 2010
  • 본 논문은 큰 용량의 배터리 충전을 위해 PWM 인버터 방식을 적용한 개별 전원장치를 병렬로 구성하여 제어하는 방식을 제안한다. 대용량의 단일 전원장치는 전력소자의 정격으로 인해 사이리스터를 사용하게 되고, 이와같은 방법은 급격한 부하 변동에 대해 응답성이 낮고 대용량의 파워필터를 사용해야 하는 단점이 발생한다. PWM 인버터 기술을 적용한 개별 전원장치를 병렬로 구성하여 제어하게 되면, 위 단점을 해소할 수 있게 되고, 전부하 영역에서 고효율의 안정적인 제어 운전이 가능하다. 제안된 방식은 PWM 인버터와 변압기 및 전력 필터로 구성하였고, 별도의 병렬 제어기가 없이 부하 전류의 분담이 가능하도록 설계 하였다.

  • PDF