• Title/Summary/Keyword: Charged refrigerant amount

Search Result 9, Processing Time 0.026 seconds

Effect of Charged Refrigerant Amount on Operating Characteristics and Development of Detecting Program for System Air-Conditioner (시스템에어컨의 냉매충전량에 따른 사이클 운전특성 및 냉매량 판독 프로그램 개발)

  • Tae, Sang-Jin;Kim, Hun-Mo;Mun, Je-Myeong;Kim, Jong-Yeop;Gwon, Hyeong-Jin;Jo, Geum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.427-432
    • /
    • 2005
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant were ranged from 60% to 140% with 10% increasement. Fuzzy algorithm were emploeed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. membership function were determined for whole ranges of experimentally measured data and rulebase were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.

  • PDF

Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm (퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발)

  • Tae S. J.;Choi C. S.;Kim H. M.;Cho K.;Moon J. M.;Kim J. Y.;Kwon H. J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

Studies on Correct Refrigerant Amount Detection for Multi-Evaporative Vapor Compression Cycle using Fuzzy Clustering (Fuzzy Clustering 기법을 이용한 Multi-Evaporator Vapor Compression Cycle의 적정 냉매량 판정에 관한 연구)

  • Kim, Sung-Hwan;Choi, Chang-Min;Kwon, Ki-Baik;Chung, Baik-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.459-464
    • /
    • 2009
  • This study has been conducted on how to determine the multi-evaporator vapor compression cycle system is charged correctly by using sensor readings which are used to control system. In this paper, the characteristics of the multi-evaporator were presented and sensor values were classified using fuzzy clustering. finally classification logic and it's performance were discussed by applying commercial VRF system.

  • PDF

Cycle Analysis of Diffusion Absorption Refrigerator (확산형 흡수식 냉장고의 사이클 해석)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

Development of Classification Model on SAC Refrigerant Charge Level Using Clustering-based Steady-state Identification (군집화 기반 정상상태 식별을 활용한 시스템 에어컨의 냉매 충전량 분류 모델 개발)

  • Jae-Hee, Kim;Yoojeong, Noh;Jong-Hwan, Jeung;Bong-Soo, Choi;Seok-Hoon, Jang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.6
    • /
    • pp.357-365
    • /
    • 2022
  • Refrigerant mischarging is one of the most frequently occurring failure modes in air conditioners, and both undercharging and overcharging degrade cooling performance. Therefore, it is important to accurately determine the amount of charged refrigerant. In this study, a support vector machine (SVM) model was developed to multi-classify the refrigerant mischarge through steady-state identification via fuzzy clustering techniques. For steady-state identification, a fuzzy clustering algorithm was applied to the air conditioner operation data using the difference between moving averages. The identification results using the proposed method were compared with those using existing steady-state determination techniques studied through the inversed Fisher's discriminant ratio (IFDR). Subsequently, the main features were selected using minimum redundancy maximum relevance (mRMR) considering the correlation among candidate features, and an SVM multi-classification model was devised using the derived features. The proposed method achieves satisfactory accuracy and robustness from test data collected in the new domain.

Performance of Heat Pumps Charged with R170/R290 Mixture (R170/R290 혼합냉매 적용 히트펌프 성능 평가)

  • Park, Ki-Jung;Lee, Cheol-Hee;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.590-598
    • /
    • 2008
  • In this study, performance of R170/R290 mixtures is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5kW. All tests are conducted under the summer cooling and winter heating conditions of $7/45^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2%. Test results show that the coefficient of performance (COP) and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for both conditions respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of 4%R170/96%R290 shows the similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is $16{\sim}30^{\circ}C$ lower than that of R22. There is no problem with mineral oil since the mixture is mainly composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.

Development of Fugitive Emission Model of HFC-134a from Mobile Air Conditioner of Passenger Automobiles (승용차 냉방장치로부터의 온실가스 냉매인 HFC-134a 탈루배출모델에 대한 연구)

  • Kim, Seungdo;Kim, Suna;Kim, Eui-Kun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.5
    • /
    • pp.518-526
    • /
    • 2012
  • The objective of this research was to develop fugitive emission models of HFC-134a (Hydrofluorocarbon-134a) at the operation and disposal stages of passenger cars. It is essential to estimate the emission of HFC-134a from mobile air conditioner (MAC) due to its high Global Warming Potential (GWP) and extensive use as a refrigerant in MAC. The first-order emission model was introduced and the emission rate constant was assumed to be unvaried with time. A commercial recovery station of refrigerants was used to recover the HFC-134a from the MAC. Average emission rate constant and annual emission rate during the operation period of vehicle are estimated to be $0.0538{\pm}0.0092$ (n=21) $yr^{-1}$ and $5.2{\pm}0.6%$, respectively within a confidence interval of 95%. According to the model results, about 50% of HFC-134a would be emitted from the MAC during the 10 years operation of passenger cars. On the other hand, average remaining portion of HFC-134a in the MACs of scrap cars is $58.2{\pm}4.8%$ (n=50) within a confidence interval of 95%, suggesting that over 40% of the initially charged amount could be released fugitively after disposal provided that the HFC-134a would not be properly treated or recycled.