• 제목/요약/키워드: Charged liquid Particle

검색결과 28건 처리시간 0.019초

제어전극을 갖는 쌍극성 하전장치의 입자응집 특성 (Particle Agglomeration of a Bipolar Charging System with a Control Grid)

  • 문재덕;안창진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

Electrospray technique for preparation of core-shell materials : A mini-review

  • Tran, Vinh Van;Lee, Young-Chul
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.49-63
    • /
    • 2018
  • During the last decade, electrospray (ES) techniques have been used as potential methods for preparing of core-shell materials. Depending on the architecture of nozzle and design of devices, the ES techniques includes monoaxial, coaxial, multiple coaxial nozzle ES and microfluidic ES devices. ES operates based on a basic principle, in which a spray of monodisperse droplets is formed by dispensing an electrically conductive liquid through a capillary charged to a sufficiently high potential. In review of many recent research papers, we take a closer look at ES techniques and their applications for fabrication of core-shell materials. Several advantages of ES technique compared with other methods were emphasized and it may be regarded as a potential tool for fabrication of core-shell materials current and near future.

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

노즐 막힘이 미세 오리피스형 다단 임팩터의 입자 채취 성능에 미치는 영향 (Effect of Particle Clogging in Orifices on the Particle Collection Efficiency of a Micro-Orifice Impactor)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.197-205
    • /
    • 2003
  • A cascade impactor is a multistage impaction device used to separate airborne particles into aerodynamic size classes. A micro-orifice impactor uses micro-orifice nozzles to extend the cut sizes of the lower stages to as small as 0.05 ${\mu}{\textrm}{m}$ in diameter without resorting to low pressures or creating excessive pressure drops across the impactor stages. In this work, the phenomenon of particle clogging in micro-orifice nozzles was experimentally investigated for a commercial micro-orifice uniform deposit impactor (MOUDI). It was observed, using an optical microscope, that the micro-orifice nozzles of the final stages were partially clogged due to particle deposition during the aerosol sampling. Therefore the pressure drops across the nozzles were higher than the nominal values given by the manufacturer. To examine the effect of particle clogging in micro-orifice nozzles, the particle collection efficiency of the MOUDI was evaluated using an electrical method for fine particles with diameters in the range of 0.1-0.6 ${\mu}{\textrm}{m}$. The monodisperse liquid dioctyl sebacate (DOS) particles were used as test aerosols. A faraday cage was employed to measure the low-level current of the charged particles upstream and downstream of each stage. It was found that the collection efficiency curves shifted to correspond to smaller orifice sizes, and the 50-% cutoff sizes were much smaller than those given by the manufacturer for the three stages with nozzles less than 400 ${\mu}{\textrm}{m}$ in diameter.

전기수력학적 힘이 분무특성에 미치는 영향 (Effects of the Electrohydrodynamic Forces on Characteristics of Spray)

  • 이종호;권순도;김상헌;문수연;이충원
    • 한국분무공학회지
    • /
    • 제6권1호
    • /
    • pp.44-51
    • /
    • 2001
  • The distributions of the SMD and behavior of 2% $NH_4H_2PO_4$ spray discharged from a fan-spray twin fluid type nozzle are measured and observed. The spray characteristics, according to the variation in the applied voltages, are demonstrated using the PMAS (particle Motion Analysis System) and the CCD camera, respectively. The preliminary experiments are executed to select an optimum condition for solidifying a galvanized coating layer in the uncharged condition before carrying out the main experiments. The liquid and air pressure of $0.07kgf/cm^2\;and\;0.15kgf/cm^2$ can be considered the optimum conditions to use in the main experiment. As the applied voltage increases, the frequent range of relatively large droplets diminishes. Thus, the distributions of drop diameter in the charged spray are more uniform than these in the uncharged condition. This is explained by recognizing that repulsive forces among droplets with the charges of the same sign cause them to be uniform.

  • PDF

입자 영상 처리 시스템을 이용한 콜로이드 입자의 제타포텐셜 측정 및 나노유체 분산 특성 연구 (A Study on the Zeta Potential Measurement and the Stability Analysis of Nano Fluids using a Particle Image Processing System)

  • 이재근;김성찬;김희중;이창건;주찬홍;이래철
    • 한국분무공학회지
    • /
    • 제8권1호
    • /
    • pp.16-22
    • /
    • 2003
  • Zeta potential measurements of colloid particles suspended in a liquid are performed by a Zeta Meter developed. There are many applications of colloid stability in spray technology, paints, wastewater treatment, and pharmaceuticalse. Zeta potentials of charged particles are obtained by measuring the electrophoretic velocities of the particles using video enhanced microscopy and image analysis program. The values of zeta potential of polystyrene latex(PSL), $silica(SiO_2)$M, polyvinylidence difluoride(PVDF), silicon nitride, and alumina particles in deionized (DI) water were measured to be -40.5, -31.9, -25.2, -15.1 and -10.1mV, respectively. The particles having high zeta potential less than -20 mV are stable in DI water, because the double layers of them have strong repulsive forces mutually, and the particles having low zeta potential over -20mV are unstable due to Van Der Waals forces. Silica(>20nm), PSL, aluminum and PVDF particles were found to be stable that would remain separate and well disperse, while silicon nitride and alumina particles were found to be unstable that would gradually agglomerate in DI water.

  • PDF

HPLC-CAD에 의한 산양삼의 극성 및 비극성 ginsenoside 동시 분석 (Simultaneous Analysis Method for Polar and Non-polar Ginsenosides in Cultivated Wild Ginseng by Reversed-phase HPLC-CAD)

  • 옥선;강재선;김강민
    • 생명과학회지
    • /
    • 제26권2호
    • /
    • pp.247-252
    • /
    • 2016
  • 산양삼은 식품 또는 약초로써 많이 사용되고 있다. 이번 연구의 목표는 high performance liquid chromatography (HPLC) - charged aerosol detection (CAD)에 의해 산양삼의 추출물에 사포닌들의 분석을 최적화 하는 것이다. CAD는 물리적인 특성은 물론이고 입자크기, 스펙트럼 특성과는 무관하게 비휘발성 물질도 분석할 수 있다. 산양삼 추출물 중 Gensenoside Rb1, Rd, Rg1, Rf, Re 및 Rh1을 분석하였다. HPLC-CAD분석을 위한 사포닌 추출물은 건조 산양삼 10 g에 95% 에탄올 100 ml을 넣어 80℃에서 24시간 동안 추출하여 사포닌을 얻었다. 6개의 주요한 사포닌을 정량화하였을 경우 값은 다음과 같다. 사포닌들의 함량은 Rb1 (5.48±0.12 mg/g), Rd (5.33±0.14 mg/g), Rg1 (12.80±0.05 mg/g), Rf (19.08±0.68 mg/g), Re (19.87± 0.05 mg/g), 및 Rh1 (16.47±0.16 mg/g)로 확인하였다. 대체적으로 산양삼 추출물의 사포닌은 protopanaxatriol (Rg1, Rf, Re, Rh1)의 값이 protopanaxadiol (Rb1, Rd)보다 높게 확인 되었다. 이번 연구에서는 산양삼 사포닌의 분석조건을 HPLC-CAD를 이용하여 최적화하였고 제품화를 위해 약리활성에 관한 연구도 매우 중요할 것이다.

공기 압력과 전기장이 접목된 액적 분무에 관한 연구 (Atomization of Liquid Via a Combined System of Air Pressure and Electric Field)

  • 황상연;성백훈;변도영
    • 한국가시화정보학회지
    • /
    • 제12권2호
    • /
    • pp.9-12
    • /
    • 2014
  • Conventional electrospray and air spray methods have the vulnerabilities of limited flow rate (throughput) and droplet size, respectively. Since high throughput with uniform size of droplet is required for various applications, an improved technique should be adopted. Here, we report a combined system of an air pressure and an electric field and evaluate the atomization performance of it. The air flow allowed applying high flow rate range and the electric field reinforced the atomization process to generate fine droplets. A correlation between two forces was investigated by comparing the droplet produced by each method. The atomized droplets were measured and visualized by image processing and a particle image velocimetry (PIV). The quantitative results were achieved from the parametric space and the effect of both forces was analyzed. The motion of charged droplets followed the outer electric field rather than the complex vortex in the shear layer so that the droplets accelerated directly toward the grounded collector.