• Title/Summary/Keyword: Charge extraction

Search Result 91, Processing Time 0.024 seconds

Design of clock/data recovery circuit for optical communication receiver (광통신 수신기용 클럭/데이타 복구회로 설계)

  • Lee, Jung-Bong;Kim, Sung-Hwan;Choi, Pyung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.1-9
    • /
    • 1996
  • In the following paper, new architectural algorithm of clock and data recovery circuit is proposed for 622.08 Mbps optical communication receiver. New algorithm makes use of charge pump PLL using voltage controlled ring oscillator and extracts 8-channel 77.76 MHz clock signals, which are delayed by i/8 (i=1,2, ...8), to convert and recover 8-channel parallel data from 662.08 Mbps MRZ serial data. This circuit includes clock genration block to produce clock signals continuously even if input data doesn't exist. And synchronization of data and clock is doen by the method which compares 1/2 bit delayed onput data and decided dta by extracted clock signals. Thus, we can stabilize frequency and phase of clock signal even if input data is distorted or doesn't exist and simplify receiver architecture compared to traditional receiver's. Also it is possible ot realize clock extraction, data decision and conversion simulataneously. Verification of this algorithm is executed by DESIGN CENTER (version 6.1) using test models which are modelized by analog behavior modeling and digital circuit model, modified to process input frequency sufficiently, in SPICE.

  • PDF

Correction for Scanning Errors of a CCD Camera Scanner (CCD Camera Scanner의 스캐닝 왜곡 보정기법 연구)

  • 안기원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.173-180
    • /
    • 1994
  • One can see more and more photograrmmetric applications dealing with the extraction of information from images obtained with CCD (Charge Coupled Device) camera scanners. In order for this information to be useful, the scanning errors of scanners must be known through a calibration. Investigation of this study is given to the detailed procedure of the correction for scanning errors created during the scanning of photographs with CCD camera scanner using the three kinds of high resolution reseal plates prepared. The geometric corrected digital images for scanning errors were generated and the accuracy of the resulting new images for each types of plates were checked comparing its image coordinates with there corresponding ground coordinates for the check points.

  • PDF

SIMS glancing anlge을 적용한 tunnel oxide 내 Nitorgen 깊이 분해능 향상 연구

  • Lee, Jong-Pil;Choe, Geun-Yeong;Kim, Gyeong-Won;Kim, Ho-Jeong;Han, O-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.41-41
    • /
    • 2011
  • Flash memory에서 tunnel oxide film은 electron tunnelling 현상을 이용하여 gate에 전하를 전달하는 통로로 사용되고 있다. 특히, tunnel oxide film 내부의 charge trap 현상과 불순물이 소자 특성에 직접적인 영향을 주고 있어, 후속 N2O/NO 열처리 공정에서 SiO2/Si 계면에 nitrogen을 주입하여 tunnel oxide film 특성을 개선하고 있다. 따라서 N2O/NO 열처리 공정 최적화를 위해서는 tunnel oxide film 내 N 농도와 분포에 대한 정확한 평가가 필수적이다[1]. 본 실험에서는 low energy magnetic SIMS를 이용하여 N2O로 열처리된 tunnel oxide film 내의 N농도를 보다 정확하게 평가하고자 하였다. 사용된 시료는 Si substrate에 oxidation 이후 N2O 열처리를 진행하여 tunnel oxide를 형성시켰으며, 분석 impact energy는 surface effect최소화와 최상의 depth resolution 확보를 위해 250eV를 사용하였으며, matrix effect와 mass interference를 방지하기 위해 MCs+ cluster mode[2]로 CsN signal를 검출하였다. 실험 결과, 특정 primary beam 입사각도에서 nitrogen depth resolution 저하 현상이 발생하였고, SIMS crater 표면이 매우 거칠게 나타났다. 이에, Depth resolution 저하 현상을 개선하기 위해 극한의 glancing 입사각 조건으로 secondary extraction voltage 변화를 통해 depth resolution이 개선되는 최적의 impact energy와 primary beam 입사각 조건을 확보하였다. 그 결과 nitrogen의 depth resolution은 1.6nm의 depth resolution을 확보하였으며, 보다 정확한 N 농도와 분포를 평가할 수 있게 되었다.

  • PDF

Development of Inorganic Metal Oxide based Hole-Transporting Layer for High Efficiency Perovskite Solar Cell (고효율 페로브스카이트 태양전지용 무기 금속 산화물 기반 정공수송층의 개발)

  • Lee, Haram;Mai, Cuc Thi Kim;Jang, Yoon Hee;Lee, Doh-Kwon
    • Current Photovoltaic Research
    • /
    • v.8 no.2
    • /
    • pp.60-65
    • /
    • 2020
  • In perovskite solar cells with planar heterojunction configuration, selection of proper charge-transporting layers is very important to achieve stable and efficient device. Here, we developed solution processible Cu doped NiOx (Cu:NiOx) thin film as a hole-transporting layer (HTL) in p-i-n structured methylammonium lead trihalide (MAPbI3) perovskite solar cell. The transmittance and thickness of NiOx HTL is optimized by control the spin-coating rate and Cu is additionally doped to improve the surface morphology of undoped NiOx thin film and hole-extraction properties. Consequently, a perovskite solar cell containing Cu:NiOx HTL with optimal doping ratio of Cu exhibits a power conversion efficiency of 14.6%.

Capacitor Failure Detection Technique for Microgrid Power Converter (마이크로그리드 전력변환장치용 커패시터 고장 검출 기법)

  • Woo-Hyun Lee;Gyang-Cheol Song;Jun-Jae An;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

An Illumination-Robust Driver Monitoring System Based on Eyelid Movement Measurement (조명에 강인한 눈꺼풀 움직임 측정기반 운전자 감시 시스템)

  • Park, Il-Kwon;Kim, Kwang-Soo;Park, Sangcheol;Byun, Hye-Ran
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.3
    • /
    • pp.255-265
    • /
    • 2007
  • In this paper, we propose a new illumination-robust drowsy driver monitoring system with single CCD(Charge Coupled Device) camera for intelligent vehicle in the day and night. For this system that is monitoring driver's eyes during a driving, the eye detection and the measure of eyelid movement are the important preprocesses. Therefore, we propose efficient illumination compensation algorithm to improve the performance of eye detection and also eyelid movement measuring method for efficient drowsy detection in various illumination. For real-time application, Cascaded SVM (Cascaded Support Vector Machine) is applied as an efficient eye verification method in this system. Furthermore, in order to estimate the performance of the proposed algorithm, we collect video data about drivers under various illuminations in the day and night. Finally, we acquired average eye detection rate of over 98% about these own data, and PERCLOS(The percentage of eye-closed time during a period) are represented as drowsy detection results of the proposed system for the collected video data.

Pulp Bleaching Effect and Ionization Rate of Chlorine Dioxide by Additive and Various pH Conditions (II) (pH와 첨가제에 의한 이산화염소의 분해율 및 펄프 표백효과(2)-첨가제가 chlorate 생성량의 감소와 펄프 표백 효과에 미치는 영향)

  • 윤병호;왕립군
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.4
    • /
    • pp.49-57
    • /
    • 1999
  • In CLO2 delignification and bleaching process, formation of chlorate corresponds to a loss of 20-36% of the original CKO2 charge. Because chlorate is inactive and harmful to environmental, it will be of benefit to find methods that can reduce the formation of chlorate during chlorine dioxide bleaching. Chlorate is mainly formed by the reaction HCIO +ClO2 $\longrightarrow$H+ + Cl_ +ClO3-2 On the other hand, AOX in chlorine dioxide bleacing is formed also due to the in-situ produced hypochlorous acid. THus both AOX and chlorate could be reduced by addition of hypochlorous acid. Some paper son the reduction of AOX by additives appeared , but systematic data on chlorate reduction as well as pulp and effluent properties are not available. THus this paper of focused on the effects on the reduction of chlorate and chlorine dioxide bleachability. The additives, fulfamic a챵, AMSO, hydrogen peroxide, oxalic acid were found to eliminate chlorine selectively in chlorine and chlorine dioxide mixture.However, when they were added to bleaching process, sulfamic acid and DMSO showed significant reduction of chlorate formation but hydrogen peroxide and oxalic aicd did not, and significant amount ofhydrogen peroxide was found resided in the bleaching effluent , In addition, sulfamic acid and DMSO decreased the bleaching end ph values while hydrogen peroxide and oxalic acid did not, which also indicated that hydrogen peroxide and oxalic acid were ineffective. The difference might be ascribed to the competitives of hypochlorous acid with lignin, chlorite (CKO2) and additives. Sulfamic acid and DMSO showed better pulpbrightness development but less alkaline extraction efficiency than hydrogen peroxide , oxalic acid and control, which means that insitu hypochlorous acid contributes to the formation of new chromophore structures that can be easily eliminated by alkaline extraction. DMSO decreased the delignification ability of chlorine dioxide due to the elimination of hypochlorous acid, but sfulfamic acid did to because the chlroinated sulfamic acid had stable bleachability. In addition, sulfamic acid, and SMSO shwed decreased color and COD of bleaching effluents, hydrogen peroxide decreased effluent color but not COD content, and oxalic acid had no statistically significant effects. No significant decreases of pulp viocosity were found except for hydrogen peroxide. Based on our results , we suggest that the effectiveness of hydrogen peroxide on the reduction of AOX in literature might be explained by other mechanisms not due to the elimination of hypochlorous acid , but to the direct decomposition of AOX by hydrogen peroxide.

  • PDF

Studies on Ion-Selective Crown Ether Dyes (이온선택성 크라운 에테르 염료에 관한 연구)

  • Sam-Woo Kang;Chong-Min Park;Won-Fae Koo;Keun-Jae Kim;Soo-Min Lee;Choo-Hwan Chang
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.443-451
    • /
    • 1988
  • New crown ether dye-Ⅰ and dye-Ⅱ having an azo group(-N=N-) were synthesized from monobenzo-15-crown-5 and dibenzo-18-crown-6. These dyes showed ${\lambda}_{max}$ of 377 and 383nm respectively. The complexes of alkali metal ions ($Na^+$, $K^+$, $Cs^+$) with dye ligands showed band shift (390~400nm) and intensity increased. For a given anion, the extraction constants are in the order of $K^+$ < $Cs^+$ < $Na^+$ for dye-Ⅰ and $Cs^+$ < $Na^+$ < $K^+$ for dye-Ⅱ. These results show that the selectivity of crown ethers toward the alkali metal ions is dependant on the charge density of cation and the size of crown ether cavity. For a given cation, the order of the extraction constant is $Cl^-$ < $Br^-$ < $I^-$ < picrate. This order coincides with the degree of anion solvation effect.

  • PDF

Technology Trends of Metal Recovery from Wastewater (폐수(廢水) 중(中) 유가금속(有價金屬) 회수기술(回收技術) 동향(動向))

  • Hwang, Young-Gil;Kil, Sang-Cheol;Kim, Jong-Heon
    • Resources Recycling
    • /
    • v.22 no.3
    • /
    • pp.91-99
    • /
    • 2013
  • Steel industry which has been accomplishes the base of our country economy, automobile and electronic industry are taking charge of the role, whose electroplating is important. Large amount of wastewater and various metal salts, including hazardous materials was generated from the electroplating pre-treatment, plating, washing and post-plating. Currently, the general wastewater follows in the environmental law and neutralization after controlling, sludge where the various metal is mixed reclaims below multiple regulative and trust it is controlling. The sludge which includes the gas price metal reclaims in the field and trust it controls. a reclamation price of land it is insufficient but and the control expense holds plentifully and it loses the gas price metal which is valuable. Consequently, The research regarding to recover a gas price metal actively from this waste water, it is advanced. A new method to recover valuable metals from electroplating wastewater synthesis of metal sulfides using topical methods utilizing iron oxidizing bacteria, reagent of sulfides and solvent extraction using an organic solvent, such as the development of the law to recover these metals and metal sulfides of wastewater using selective recovery have been studied. By using these wastewater treatment method under frequency above 95%, it has been obtained the valuable metal from the wastewater, where the metal ion of Fe, Cu, Zn and Ni complexes was mixed. As we discuss the wastewater, which has been discharged from electroplating process, it is important and will be applied to the resources of metal in the urban mine.

Method for Screening and Confirming Meldonium in Human Urine by High-Resolution Mass Spectrometry and Identification of Endogenous Interferences for Anti-Doping Testing

  • Kim, Yongseok;Jeong, Dawon;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.39-43
    • /
    • 2017
  • Meldonium is a drug for treating ischemia by expanding the arteries but it can also enhance the performance of sports players. The World Anti-Doping Agency (WADA) has included it in the list of prohibited substances since 2016. Meldonium is one of the challenging substances for anti-doping testing because it is difficult to recover by general liquid-liquid or solid phase extraction due to its permanent charge and high polarity. Therefore, high-performance liquid chromatography (HPLC) is currently used by injecting a diluted urine sample (known as the "dilute-and-shoot" strategy). There is no loss of target compounds in the extraction/cleanup procedure but its high matrix effect could interfere in their separation or detection from the endogenous urinary compounds. We report a single method using high-resolution mass spectrometry that can be used for both screening and confirmation, which follows the "dilute-and-shoot" strategy. In this method, the endogenous compounds' interfering peaks in the mass spectrum are separated at a high resolution of FWHM 140,000, and the results are suitable for substance detection following the WADA guidelines. The interferences in the obtained mass spectrum of the urine matrix are identified as acetylcholine, lysine, and glutamine by further analysis and database searching. Validation of the method is performed in routine anti-doping testing, and the limit of detection is 50 ng/mL. This method uses simple sample preparation and a general reverse phase HPLC column, and it can be easily applied to other substances.