• Title/Summary/Keyword: Charge balance

Search Result 150, Processing Time 0.031 seconds

A study on the runner system for filling balance in multi-cavity injection molds (다수 캐비티 사출금형에서의 균형 충전을 위한 러너 시스템 연구)

  • Jeon, Kang-Il;Noh, Seung-Kyu;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1581-1588
    • /
    • 2011
  • In this study, flow characteristics in a multi-cavity injection molding process were investigated. One of main problems occurred in the multi-cavity molding is a flow imbalance among cavities since it affects physical properties and quality of products. Charge imbalance is caused by the uneven shear stress. Therefore, changes in viscosity affect the physical properties of resin and injection conditions differ in the filling imbalance phenomenon. Through, this study focus on experimental studies of flow imbalance for PC and PP resin occurring in a balanced delivery system. Experimental results were compared with CAE results. By experimental and CAE analysis, main cause for the flow imbalance is temperature distribution in cross section of runner. New runner system with a simple change of runner shape was suggested to avoid the flow imbalance. A series of simulation to confirm feasibility of Volume Runner's effects was conducted using injection molding CAE.

A New Current-Balancing Multi-Channel LED Driver for a Large Screen LCD Backlight Unit (대화면 LCD Backlight를 위한 새로운 전류평형 다채널 LED 구동회로)

  • Lee, Sang-Hyun;Cho, Sang-Ho;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.111-118
    • /
    • 2010
  • Recently, LCD TV using LED backlight has a great attention due to its low power consumption, slim construction, mercury free, wide color gamut and fast response. For the uniform brightness of the LCD panel, multi channel LEDs and DC/DC converter for each LED are required in conventional system. Therefore energy conversion efficiency is poor, the system size bulky and the cost of production high. To overcome these above mentioned drawbacks, a new current-balancing multi-channel LED driver is proposed in this paper. It can not only drive multi-channel LEDs with one DC/DC converter but also provide all LEDs with constant balanced current. To confirm the validity of the proposed driver, its operation and performance are verified on a prototype for 46" LCD TV.

Solvent Extraction Equilibria of Gd with PC88A from Chloride Solution (염산용액에서 PC88A에 의한 Gd 용매추출의 평형)

  • Lee Gwang-Seop;Lee Jin-Young;Kim Sung-Don;Kim Joon-Soo;Park Jang-Hyun;Lee Man-Seung
    • Resources Recycling
    • /
    • v.13 no.2
    • /
    • pp.24-32
    • /
    • 2004
  • Solvent extraction equilibria of Gd with PC88A from chloride solutions were analyzed by considering chemical equilibria. phase equilibria, mass and charge balance equations. The following solvent extraction reaction and equilibrium constant were evaluated from the experimental data performed in this study. $Gd^{3+}$ $+2H_2$$A_2$,$or=GdA_3$HA.or+3 $H^{+}$ , K=3.3 A procedure was suggested to calculate the initial concentration of chloride ion from initial pH and initial concentration of Gd. By applying ionic equilibria, the distribution of Gd complexes with Gd and HCl concentration was obtained. The predicted distribution coefficients of Gd agreed well with the experimental results.

A Research Trend on Film Thickness Dependence of Ac High Feld for Low Density Polyethylene (저밀도 폴리에틸렌을 위한 고전계 파형의 필름 두께의존성에 관한 연구 동향)

  • Jung, Sung-Chan;Rho, Jung-Hyun;Lee, Joo-Hong;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1988-1989
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. We have already reported that the dissipation currents of $40\;{\mu}m$ thick LDPE film at 10 kV/mm and over 140 Hz, it starts to show nonlinearity and odd number's harmonics were getting large. To investigate the conduction mechanis ms in this region, especially space charge effect, various kinds of estimation, such as time variations of instantaneous resistivity for one cycle, FFT spectra of dissipation current waveforms and so on, has been examined. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

A Problem of Locating Electric Vehicle Charging Stations for Load Balancing (로드밸런싱을 위한 전기차 충전소 입지선정 문제)

  • Kwon, Oh-Seong;Yang, Woosuk;Kim, Hwa-Joong;Son, Dong-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.9-21
    • /
    • 2018
  • In South Korea, Jeju Island has a role as a test bed for electric vehicles (EVs). All conventional cars on the island are supposed to be replaced with EVs by 2030. Accordingly, how to effectively set up EV charging stations (EVCSs) that can charge EVs is an urgent research issue. In this paper, we present a case study on planning the locations of EVCS for Jeju Island, South Korea. The objective is to determine where EVCSs to be installed so as to balance the load of EVCSs while satisfying demands. For a public service with EVCSs by some government or non-profit organization, load balancing between EVCS locations may be one of major measures to evaluate or publicize the associated service network. Nevertheless, this measure has not been receiving much attention in the related literature. Thus, we consider the measure as a constraint and an objective in a mixed integer programming model. The model also considers the maximum allowed distance that drivers would detour to recharge their EV instead of using the shortest path to their destination. To solve the problem effectively, we develop a heuristic algorithm. With the proposed heuristic algorithm, a variety of numerical analysis is conducted to identify effects of the maximum allowed detour distance and the tightness of budget for installing EVCSs. From the analysis, we discuss the effects and draw practical implications.

Structure analysis, and magnetic study of a new Gd-metal-organic framework single crystal grown by the slow-evaporation method (증발법으로 합성된 신규 가돌리늄 금속-유기골격체의 단결정 구조 분석 및 자성학적 특성 연구)

  • Song, Jeong Hwa
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.5
    • /
    • pp.199-204
    • /
    • 2022
  • A new three-dimensional Gd-MOF, [Gd(p-XBP4)4(H2O)]·W(CN)8; (1; p-XBP4 = N,N'-p-phenylenedimethylenbis (pyridin-4-one)) has been synthesized by slow-evaporation and its crystal structure was characterized by single-crystal X-ray diffraction (SCXRD) analysis. For each GdIII ion, there are seven coordination sites, which are occupied by six oxygen atoms of six p-XBP4 ligands and one oxygen atom from the water molecule. The [W(CN)8]3- anion exists for charge balance with cationic framework. The GdII ions are interconnected by the p-XBP4 ligand to form the three-dimensional structure. Considering the magnetic property of lanthanide ions, magnetic studies of Gd-MOF were investigated by direct-current (DC) magnetic susceptibilities measurements.

The Effect of PNF Technique application Using Thera-Band on the Balance and Gait of Females over 65 years old (세라밴드를 이용한 PNF 기법 적용이 65세 이상 여성노인의 균형과 보행에 미치는 영향)

  • Kang, Dal-Won;Kang, Mi-Kyoung;Kang, Eun-Sil;Go, Yu-Ri;Kim, Da-Woon;Kim, Dae-Yong;Kim, Jung-Eun;Kim, Won-Hwang;Kim, Ja-Yeon;Kim, Hwan;Jung, Dae-In;Kim, Myung-Hoon;Kim, Sang-Yup;Lee, Dong-Jin;Kim, Chan-Kyu;Kim, Hyun-Jin
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Purpose: Study on the effect of the use of Proprioceptive Neuromuscular Facilitation(PNF) method by use of the direction and charge regulation which is the advantage of the Thera-band therapy on the walks and balances in old people and comparison with the result after applying the general PNF technique. Method: The study has been performed on 30 females over 65 years old. The study has been done by dividing the object group in 3 patterns, which are number 1, the comparison group of 10, two ones that are applied the PNF technique using Thera-band and third, the ones that are applied only the PNF technique. For the PNF and the Thera-band using PNF, we have divided the group into Combination of Isotonic technique and the Rhythmical stabilization technique according to the patient's acquaintance pattern and applied them to the patient's body. Evaluation was the balancing ability which was calculated by using the BIODEX Balance system / FRT and for the evaluation of walking ability, we have used the speed of walking for 10M / TUG. Result: In the comparison group of 10, the balancing ability and the walking ability did not change much before and after the experiment, which made it possible to compare the group with the other two easily(p>0.05). For the other two groups, we have recognized the enhancement both in the balancing ability and the walking ability, but they did not know much difference between themselves(p<0.05). Conclusion: Though there were not a big difference in the sense of improvement between the Thera-band using PNF and the PNF technique only, we could infer that these two therapy has enhanced much in the walking and balancing ability for people over 65 and through these result we can foresee that not only using the method shown in this study but also by using many advantages of Thera-band, we could diminish the tiredness of healer, enhance the efficiency of exercise in them and also by forming self training program for older people we could help them build the prevention program from falls.

  • PDF

Levodopa Transport through Skin using Iontophoresis: the Role of Electroosmosis and Electrorepulsion (이온토포레시스를 이용한 levodopa의 경피전달: electroosmosis 및 electrorepulsion의 역할)

  • Jung, Shin-Ae;Gwak, Hye-Sun;Chun, In-Koo;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • The objective of this work is to study transdermal delivery of levodopa using iontophoresis and evaluate various factors which affect the transdermal transport. Levodopa is unstable in aqueous solution, and, in order to establish a stable condition for levodopa for the duration of experiment, we investigated the stability of levodopa in aqueous solutions of different pHs with/without the addition of dextrose or the application of current. Using stable aqueous solution, we have studied the effect of pH, polarity and penetration enhancer (ethanol) on transdermal flux and compared the results. We also investigated the iontophoretic flux from hydroxypropyl cellulose (HPC) hydrogel. In vitro flux study was performed at $33^{\circ}C$, using side-by-side diffusion cell. Full thickness hairless mouse skin and rat skin were used for this work. Current densities applied were 0.4 or $0.6mA/cm^2$ and current was off after 6 hour application. Stability study showed that levodopa solution with a pH 2.5 or 4.5 maintained the initial concentration of levodopa for 24 hours with the addition of 5% dextrose. However, at pH 9.5, levodopa was unstable and 30 to 40% of levodopa degraded within 24 hours, even with the addition of 5% dextrose. Hydrogel swollen with dextrose added levodopa solution maintained about 97% of the initial concentration of levodopa for 13 days, when stored in $4^{\circ}C$. The application of current did not affect the stability of levodopa in hydrogel. Flux study from levodopa solution with pH 2.5 showed that cathodal delivery of levodopa was higher than passive or anodal delivery. When the pH of the donor solution was 4.5, anodal delivery of levodopa was higher than passive or cathodal delivery. These results seem to indicate that electroosmosis plays more dominant role than electrorepulsion in the flux of levodopa at pH 2.5, and the reverse situation applies for pH 4.5. The passive flux was unexpectedly high for the ionized levodopa. Similar to the results from aqueous solution, cumulative amount of levodopa transported trom HPC hydrogel by cathodal delivery was significantly higher than passive or anodal delivery. The treatment of 70% ethanol cotton ball by scrubbing increased passive, anodal and cathodal flux, with the largest increase for anodal flux. These results indicate that iontophoretic delivery of zwitterion such as levodopa is much complicated than that can be expected from small ionic molecules with single charge. The results also indicate that the balance between electroosmosis and electrorepulsion plays a very important role in the transport through skin.

The study about the cause of the Korean professional pitchers' injury and its classification (한국 프로야구투수들의 부상 발생원인 및 분류에 관한 연구)

  • Nam Joung-Chul;Kim Sang-Su;Lee Dong-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.172-182
    • /
    • 2002
  • Objectives: We did research in the cause of the Pitchers' injury and their recovery process to make a detailed injury list for the purpose of finding the cause of the Korean professional pitchers' injury and its classification. We drew the conclusion through the results as following. Methods: We posed a question to the 80 pitchers playing in the first team of the eight Korean professional baseball team and analyzed the 62 pieces of question paper except the paper having a mistake. We used SAS/PC statistical package in analyzing the data. Results: In the frequency of the pitchers' shoulder injury in the last three years, the injured of all the players were 61.3$\%$ and the injury free players were 28.7$\%$. The cause of the injury was 45.2$\%$ wrong pitching motion, which was the highest value. For the shape of a pain when injured, the reverberation ache feeling when he is hit in the weight commanded an absolute majority as 19.4$\%$. Those who had muscular pain were 17.7$\%$, which was felt mostly at the pitching motion. The most trouble name of the injured shoulder was bicepstendinitis as 16.1$\%$ while the injury of shoulder joint was the lowest as 1.6$\%$. As the most widely used treatment, 25.8 percent of all the players had taken an electronical thraphy after injury. 14.5 percent of the players who had an injury to the shoulder told that they have an operation and 85 percent of them didn't. As a sort of the operation, a repairing of labrum was 44.4 percent, which is the highest value and the 77.8 percent pitchers are performing a normal pitching through rehabilitation after the operation and 22.2 percent of them are undergoing rehabilitation training. Conclusion: The research have shown that the main cause of the injury, concerning the Korean professional pitchers throwing lots of ball in both matches and practices, is overuse syndrome, bad mechanism, muscle weakness and instability of balance. I think that the role of trainer, physical therapy, and team physician taking charge of the players' injury must learn physical test method by heart exactly to check up the state of the injury definitely at the initial phase. Moreover, when the cause of the injury part after a close examination is discovered, the scientific and good surgery is essential to the rehabilitation success and making a classification of shoulder instability is useful to make a operation plan as well as the players' rehabilitation, treatment.

  • PDF

Characteristics of the Problem Solving Process of the Balancing Redox Equations by Senior and Science High School Students' Mental Capacity and Problem Solving Methdos (일반고와 과학고 학생들의 정신용량과 풀이 방법에 따른 산화 환원 반응식 완결 과정의 특성)

  • Kim, Chung-Ho;Lee, Sang-Gwon
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.4
    • /
    • pp.353-363
    • /
    • 2002
  • In this study, characteristics of the problem solving process of the balancing redox equations was ana-lyzed by mental capacity and problem solving methods, and the pertinent teaching and learning guidance for oxidation-reduction unit was suggested. Participants were 79 senior high school students and 57 science high school students. Tests were conducted to measure the mental capacity, the understanding of the oxidation-reduction concepts and the com-pletion of the balancing redox equations. The framework was made to find the patterns of failure and success. As the analysis of the influence on the performance of mental capacity,understanding of the oxidation-reduction concepts, and problem solving methods, students who had lower understanding of oxidation-reduction concepts selected the trial and error method, and their performance were influenced by mental capacity. The students that had higher understanding of the oxidation-reduction concepts had good performance by using oxidation number method regardless of their mental capacity. As the results of analysis for the patterns, the success patterns of solving the problems, those of mostly the sci-ence high school students, were the cases of using oxidation number method well and lessening problem solving steps. The patterns of failure in solving problems by using trial and error method showed that students had mistakes in cal-culating, errors in making unknown equations, no consideration for all variables, or stopped solving the complicated problems. The patterns of failure in solving problems by using oxidation number method showed that many students had wrong oxidation number or no consideration for mass and charge balance.