• Title/Summary/Keyword: Charge and discharge control for the battery

Search Result 56, Processing Time 0.024 seconds

Embedded System Design for Precision Control of the Secondary Battery Charge/Discharge Production Process (2차 전지 충.방전 생산 공정 정밀제어를 위한 임베디드 시스템 개발)

  • Choi, Joong-Hyun;Kim, Jong-Tae;Oh, Jae-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.150-152
    • /
    • 2004
  • The battery charge/discharge process, the final step of the secondary battery production process, requires real-time precision controls for improving both lifetime and performance of the battery cell. In this paper, we present embedded system design for precision control of the secondary battery charge/discharge production process using low power embedded processor based on embedded linux. This system receive charge/discharge command from the main server through ethernet. Compared to existing charge/discharge control system, our design makes low cost and precision control system possible.

  • PDF

The Improved Characteristics of the Stand-alone PV System by the Independent Battery Control Method (밧데리 개별 제어 방식에 의한 소규모 독립형 태양광 발전 시스템의 특성 개선)

  • 강신영;이양규;김광헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.482-489
    • /
    • 2002
  • This paper studies the stand-alone photovoltaic system for the solar lighting lamp. The solar lighting lamp has PV modules, batteries, and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50% and the depth of discharge control can be controlled in the discharge cut off voltage. It can be effective of the battery use. If a battery is out of order, this system can be executed for a regular period. So we saved the repair cost and developed of system's stabilization. It Is possible to make economical effects to apply for solar lighting lamp used photovoltaic system.

The improved efficiency Study of PV system for the Solar lamp lighting (태양광 가로등 발전 효율개선 연구)

  • Kang, Sin-Young;Lee, Yang-Guy;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.304-308
    • /
    • 2002
  • This paper studies stand-alone photovoltaic array for solar lighting lamp. The solar lighting lamp has PV modules, batteries. and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50%. and the depth of discharge control can be controlled in the discharge cut off voltage. This can be effective of battery use. If a battery is out of order, this system can be executed for a regular period. so we saved the repair cost and developed of system's stabilization. It is possible economical effect to apply for solar lighting lamp used photovoltaic array.

  • PDF

A Study on the Configuration of BOP and Implementation of BMS Function for VRFB (VRFB를 위한 BOP 구성 및 BMS 기능구현에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Chung, Dong-Hwa;Park, Byung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.74-83
    • /
    • 2014
  • This paper proposes a study on the configuration of balancing of plant(BOP) and implementation of battery management system(BMS) functions for vanadium redox flow battery(VRFB) and propose a method consists of sensor and required design specifications BOP system configuration. And it proposes an method of the functions implementation and control algorithm of the BMS for flow battery. Functions of BMS include temperature control, the charge and discharge control, flow control, level control, state of charge(SOC) estimation and a battery protection through the sensor signal of BOP. Functions of BMS is implemented by the sensor signal, so it is recognized as a very important factor measurement accuracy of the data. Therefore, measuring a mechanical signal(flow rate, temperature, level) through the BOP test model, and the measuring an electrical signal(cell voltage, stack voltage and stack current) through the VRFB charge-discharge system and analyzes the precision of data in this paper. Also it shows a good charge-discharge test results by the SOC estimation algorithm of VRFB. Proposed BOP configuration and BMS functions implementation can be used as a reference indicator for VRFB system design.

Design of Battery Charge-Discharge Controller for Renewable Energy System -Focusing on Solar Battery Charge-Discharge Controller - (신재생 에너지 시스템을 위한 축전지 충방전 컨트롤러 설계 -태양광 발전 축전지 충방전 컨트롤러를 중심으로-)

  • Lee, Jae-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1363-1368
    • /
    • 2007
  • In order to utilize renewal energy such as solar power and wind power, high performance battery charge-discharge controller is essentially needed. In this paper, a PIC microprocessor-based battery charge-discharge controller for solar power system is designed and implemented. The PIC16C711 microprocessor and CCS-C compiler are used to realize stable and accurate operation of the battery controller. The proposed controller is designed to utilize the charged battery power during daytime to provide convenience to user. Current control function is included in proposed controller to cope with various type of new material energy system coming in the near future.

  • PDF

The PV MPPT & Charge and Discharge Algorithm for the Battery Included Solar Cell Applications (배터리 내장형 초소형 태양광 장치용 PV MPPT 및 충방전 제어 알고리즘)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lae, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.69-75
    • /
    • 2013
  • To increase the efficiency of the photovoltaic, almost photovoltaic appliances are controlled by Maximum Power Point Tracking(MPPT). Existing most of the PV MPPT techniques have used power which multiplies sensed output current and voltage of the solar cell. However, these algorithms are unnecessarily complicated and too expensive for small and compact system. The other hand, the proposed MPPT technique is only one sensing of the MPPT converter's output current, so there is no need to insert another sensors of battery side. Therefore, this algorithm is simpler compared to the traditional approach and is suitable for low power solar system. Further, the novel proper charge/discharge algorithm for the battery with PV MPPT is developed. In this algorithm, there is CC battery charge mode and load discharge mode of the PV cell & battery dual. Also we design current control to regulate allowable current during the battery charging. The proposed algorithm will be applicable to battery included solar cell applications like solar lantern and solar remote control car. Finally, the proposed method has been verified with computer simulation.

Charge/discharge Properties of Flyash as a Anode for Lithium Polymer Battery (리튬 폴리머 전지용 Flyash 부극의 충방전 특성)

  • Song, Hee-Woong;Kim, Jong-Uk;Park, Gye-Choon;Gu, Hal-Bon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.968-970
    • /
    • 1999
  • The trend of increasing of portable electric devices and demand for global environmental conservation have demands the development of high energy density rechargeable batteries. Lithium polymer battery has excellent theoretical energy density and energy conversion efficiency. Lithium polymer battery, included solid polymer electrolyte(SPE), can be viewed as a system suitable for wide applications from thin film batteries for microelectronics to electric vehicle batteries. The purpose of this paper is to research and development of flyash anode for lithium polymer battery. We investigated AC impedance response and charge/discharge characteristics of flyash/SPE/Li cells. The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell increased very slowly during discharge process from 3.11V to 0.478V. And then the cell resistance was decreased at discharge process from 10% SOC to 0% SOC. Also, The radius of semicircle associated with the interfacial resistance of flyash/SPE/Li cell decreasing very slowly during charge process. And then the cell resistance was increased after 20th discharge precess. The discharge capacity based on flyash of 1st and 20th cycles was 276mAh/g and 143mAh/g.

  • PDF

The Battery Management System for UPS Lead-Acid Battery (UPS용 납축전지를 위한 배터리관리시스템)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.127-133
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system control the currents and voltages of battery for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It proved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

A Study on Adaptive Operation Control to Stabilize bus Voltage of GEO Satellite Power Supply Module (정지궤도 위성용 전력공급 모듈의 버스 전압 안정화를 위한 최적동작 제어에 관한 연구)

  • Ahn, Tae-Young;Choe, Hyun-Su
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.123-129
    • /
    • 2016
  • In this paper, results of produced PCU(Power Control Unit) prototype was showed by suggesting and maintaining optimal operation status which let the three functional modules automatically operate with its necessity by prioritizing operation process. In order to validate effectiveness of the suggested method, we produced a test PCU and examined the results. PCU consists of S3R(Sequential Switching Shunt Regulator), BCR(Battery Charge Regulator), and BDR(Battery Discharge Regulator): converting photovoltaic power into constant voltage at linked bus voltage; storing dump power in the battery which is an auxiliary energy storage device; and supplying power charged in battery to the load. To maintain its high reliability and optimal condition of these three power conversion modules, each module operates in parallel and stable bus voltage is required to be retained at all-time due to the nature of power supply for satellite.

Design on Algorithm of Power Control Unit for Charging Satellite Battery (위성 배터리 충전을 위한 전력제어유닛의 알고리즘 설계)

  • Park, JeongEon;Lee, Byoung-Hee
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.95-99
    • /
    • 2017
  • The lifetime of a battery that supplies all the power required by a satellite in the eclipse is directly related to the lifetime of the satellite. Because the lifetime of the battery is influenced by the charging method of the battery, the power control unit that controls the charging of the battery should be designed in consideration of battery life. The battery charging is performed by controlling the charge current in the power control unit generated from the solar cell in the daytime. In order to prevent overcharge of the battery and for considering frequency of eclipse in each season, parameters related battery charging should be designed differently according to the season and to prevent over-current charging and over-voltage charging during charging, charge current is controlled by monitoring battery charge / discharge status, charge current amount, battery voltage, battery capacity, battery temperature and battery cell voltage. In satellite, tapering method is used to control charge current by reflecting each condition. In this paper, design battery charging algorithm of satellite power control unit using tapering charging method. convert the designed algorithm into a code that can be uploaded to satellites and verify the operation through testing in the established satellite environment.