• Title/Summary/Keyword: Charge Pump

Search Result 297, Processing Time 0.02 seconds

Design of 2-Ch DC-DC Converter with Wide-Input Voltage Range of 2.9V~5.6 V for Wearable AMOLED Display (2.9V~5.6V의 넓은 입력 전압 범위를 가지는 웨어러블 AMOLED용 2-채널 DC-DC 변환기 설계)

  • Lee, Hui-Jin;Kim, Hak-Yun;Choi, Ho-Yong
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.859-866
    • /
    • 2020
  • This paper proposes a 2-ch DC-DC converter with a wide-input voltage range from 2.9V~5.6V for wearable AMOLED displays. For positive voltage VPOS, a boost converter is designed using an over-charged voltage permissible circuit (OPC) which generates a normal output voltage even if over-input voltage is applied, and a SPWM-PWM dual mode with 3-segmented power transistors to improve efficiency at light load. For negative voltage VNEG, a 0.5x regulated inverting charge pump is designed to increase power efficiency. The proposed DC-DC converter was designed using a 0.18-㎛ BCDMOS process. Simulation results show that the proposed DC-DC converter generates VPOS voltages of 4.6 V and VNEG voltage of -0.6V~-2.3V for input voltage of 2.9V to 5.6V. In addition, it has power efficiency of 49%~92%, output ripple voltage has less than 20 mV for load current range of 1 mA~70 mA.

A Micro-Scale Photovoltaic Energy Harvesting Circuit Using Energy Distribution Technique (에너지 분배 기능을 이용한 마이크로 빛에너지 하베스팅 회로)

  • Lee, Shin-woong;Lee, Chul-woo;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.581-584
    • /
    • 2014
  • In this paper, a micro-scale photovoltaic(PV) energy harvesting system is proposed where an MPPT(Maximum Power Point Tracking) control is implemented using an energy distribution technique. Miniature PV cells output very low energy and low voltages, and thus, they cannot be used to directly power the MPPT controller. In the proposed system, a start-up circuit boosts an internal Vcp, and the boosted Vcp is used to operate the internal MPPT control block. When the Vcp reaches a predefined value, a detector circuit makes the start-up block turn off and provide a power converter with the energy from the PV cell. When the Vcp decreases such that the MPPT controller can not be operated, the energy transferred to the power converter is blocked and the start-up circuit is reactivated. In this way, the MPPT function is achieved by alternately operating the start-up circuit and the power converter using the energy distribution technique, and the harvested energy is transferred to a load through a PMU(Power Management Unit). The proposed circuit is designed in a 0.35um CMOS process and its functionality has been verified through extensive simulations. The designed chip area including pads is $1430um{\times}1110um$.

  • PDF

A Low Jitter Delay-Locked Loop for Local Clock Skew Compensation (로컬 클록 스큐 보상을 위한 낮은 지터 성능의 지연 고정 루프)

  • Jung, Chae-Young;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.309-316
    • /
    • 2019
  • In this paper, a low-jitter delay-locked loop that compensates for local clock skew is presented. The proposed DLL consists of a phase splitter, a phase detector(PD), a charge pump, a bias generator, a voltage-controlled delay line(VCDL), and a level converter. The VCDL uses self-biased delay cells using current mode logic(CML) to have insensitive characteristics to temperature and supply noises. The phase splitter generates two reference clocks which are used as the differential inputs of the VCDL. The PD uses the only single clock from the phase splitter because the PD in the proposed circuit uses CMOS logic that consumes less power compared to CML. Therefore, the output of the VCDL is also converted to the rail-to-rail signal by the level converter for the PD as well as the local clock distribution circuit. The proposed circuit has been designed with a $0.13-{\mu}m$ CMOS process. A global CLK with a frequency of 1-GHz is externally applied to the circuit. As a result, after about 19 cycles, the proposed DLL is locked at a point that the control voltage is 597.83mV with the jitter of 1.05ps.

A Study on the Optimal Operation and Policy of the Boryeong Dam Diverion Pipe Line Using the SWAT Model (SWAT 모형을 이용한 보령댐 도수로 운영 방안 및 정책 연구)

  • Park, Bumsoo;Yoon, Hyo Jik;Hong, Yong Seok;Kim, Sung Pyo
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.546-558
    • /
    • 2020
  • While industrialization has provided in abundance, the pollution it creates has caused untold damage to the environment, increasing the frequency and severity of natural disasters through changes in global climate patterns. The World Risk Forum's (WEF) World Risk Report presented the results of a survey of experts from around the world detailing the most influential risk factors over the next decade. Notably, the failure to respond to climate change ranked first and the global water crisis third. The extreme drought in the western Chungnam province was unexpected in 2016. At the time, the water level of Boryeong Dam was drastically decreased due to receiving less than half the average recorded rainfall in the region that year. The Boryeong Dam diversion pipeline has the capacity to solve the water shortage problem between these two regions by providing water from Geumgang to the western part of Chungnam, including Boryeong City. Current weather trends suggest drought is likely to continue in western Chungnam, which uses the Boryeong Dam as an intake source. This makes it necessary to operate Boryeong Dam diversion pipeline in an efficient and effective manner. SWAT is a watershed scale model developed to predict the impact of land management practices on water. The SWAT model was used in this study to evaluate the adequacy of the Boryeong Dam diversion pipeline operational plan by comparing it to present Boryeong Dam diversion pipeline operation. By investigating the number of days required to reach each reservoir stage, we determined that the number of days required to reach the boundary stage was less than that of the current operation. This determination accounts for the caveats that the Boryeong Dam waterway was not operated and only one pump will be operated from October to May of next year. As our results suggest, the most stable operation scenario is to operate two pumps at all times. This can be accomplished by operating two pumps from the caution stage to increase the number of pumps whenever the stage is raised. In addition to the stable operation of the Boryeong Dam pipeline, policy considerations are required with regard to imposing a water use charge on users of the Boryeong Dam region.

Financial Impact of Off-Pump Coronary Artery Bypass (체외순환 없이 시행하는 관상동맥우회술의 경제성 분석)

  • Lim, Cheong;Chang, Woo-Ik;Kim, Ki-Bong;Kim, Yoon
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.365-368
    • /
    • 2002
  • Background: Coronary artery bypass grafting(CABG) imposes large amount of medical costs, which are greatly affected by the surgical approach, quality of perioperative care and associated co-morbidities. Recently, off-pump CABG(OPCAB) has been introduced and performed with increasing frequency. To evaluate the efficacy of OPCAB in view of financial impact, we analyzed the costs and medical resources of OPCAB and compared with conventional CABG. Material and Method: From January 1998 to July 1999, 184 patients underwent CABG operation; 111 patients with OPCAB(group I) and 73 patients with conventional CABG(group II). We prospectively collected clinical data including risk factors and retrospectively reviewed the hospital resources. Result: Preoperative parameters including risk factors, postoperative mortality, morbidity and length of hospital stay were not different between the two groups, Duration of stay in the intensive care unit(ICU) (51.3 vs 128.3 hours, p<0.01) and ventilator, support time(14.9 vs 56.2 hours, p<0.01) were significantly shorter in the OPCAB group. Total hospital coats were 17,220,000 add 21,250,000(Korean Won) in group I and II, respectively(p<0.01). There were significant differences in operation fee, costs for operative materials, transfusion and diagnostic radiology between two groups. In group I, all the resources except diagnostic radiology were significantly decreased compared with group II. Conclusion: OPCAB has a beneficial effect on hospital charge and resource utilization. Shorter duration of the ICU stay and ventilatory support time may reduce the total hospital costs.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.