• 제목/요약/키워드: Charge Balance

검색결과 150건 처리시간 0.024초

A Numerical Solution of Transport of Mono- and Tri-valent Cations during Steady Water Flow in a Binary Exchange System

  • Ro, Hee-Myong;Yoo, Sun-Ho
    • Journal of Applied Biological Chemistry
    • /
    • 제43권1호
    • /
    • pp.18-24
    • /
    • 2000
  • A one-dimensional transport of displacing monovalent ion, $A^+$, and a trivalent ion being displaced, $B^{3+}^ in a porous exchange system such as soil was approximated using the Crank-Nicolson implicit finite difference technique and the Thomas algorithm in tandem. The variations in the concentration profile were investigated by varying the ion-exchange equilibrium constant (k) of ion-exchange reactions, the influent concentrations, and the cation exchange capacity (CEC) of the exchanger, under constant flux condition of pore water and dispersion coefficient. A higher value of k resulted in a greater removal of the native ion, behind the sharper advancing front of displacing ion, while the magnitude of the penetration distance of $A^+$ was not great. As the CEC increased, the equivalent fraction of $B^{3+}^ initially in the soil was greater, thus indicating that a higher CEC adsorbed trivalent cations preferentially over monovalent ions. Mass balance error from simulation results was less than 1%, indicating this model accounted for instantaneous charge balance fairly well.

  • PDF

기본상수를 이용한 SI 기본단위의 재정의 (Redefinition of the SI Base Units with Fundamental Constants)

  • 이호성
    • 한국광학회지
    • /
    • 제30권4호
    • /
    • pp.133-141
    • /
    • 2019
  • 기본상수를 이용한 국제단위계 개정이 2018년 11월에 개최된 제26차 국제도량형총회에서 채택되었다. 국제단위계에 속한 4개의 기본단위(킬로그램, 암페어, 켈빈, 몰)가 각각 그 값이 고정된 플랑크 상수 h, 기본 전하 e, 볼츠만 상수 k, 아보가드로 상수 $N_A$를 기반으로 재정의되었다. 이 논문에서는 키블 저울을 이용하여 플랑크 상수로부터 킬로그램을 재정의한 원리를 설명한다. 개정된 국제단위계는 2019년 5월 20일부터 발효된다.

충전 프로파일 및 셀 밸런스 제어기술을 활용한 대용량 리튬이온 배터리 고속충전시스템 개발 (Development of a Fast Charging System Utilizing Charge Profile and Cell Balance Control Technology for Large Capacity Lithium-ion Batteries)

  • 가니 도가라 유나나;안재영;박찬원
    • 산업기술연구
    • /
    • 제40권1호
    • /
    • pp.7-12
    • /
    • 2020
  • Lithium-ion cells have become the go-to energy source across all applications; however, dendritic growth remains an issue to tackle. While there have been various research conducted and possible solutions offered, there is yet to be one that efficiently rules out the problem without, however, introducing another. This paper seeks to present a fast charging method and system to which lithium-ion batteries are charged while maintaining their lifetime. In the proposed method, various lithium cells are charged under multiple profiles. The parameters of charge profiles that inflict damage to the cell's electrodes are obtained and used as thresholds. Thus, during charging, voltage, current, and temperature are actively controlled under these thresholds. In this way, dendrite formation suppressed charging is achieved, and battery life is maintained. The fast-charging system designed, comprises of a 1.5kW charger, an inbuilt 600W battery pack, and an intelligent BMS with cell balancing technology. The system was also designed to respond to the aging of the battery to provide adequate threshold values. Among other tests conducted by KCTL, the cycle test result showed a capacity drop of only 0.68% after 500 cycles, thereby proving the life maintaining capability of the proposed method and system.

Differential Power Processing System for the Capacitor Voltage Balancing of Cost-effective Photovoltaic Multi-level Inverters

  • Jeon, Young-Tae;Kim, Kyoung-Tak;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1037-1047
    • /
    • 2017
  • The Differential Power Processing (DPP) converter is a promising multi-module photovoltaic inverter architecture recently proposed for photovoltaic systems. In this paper, a DPP converter architecture, in which each PV-panel has its own DPP converter in shunt, performs distributed maximum power point tracking (DMPPT) control. It maintains a high energy conversion efficiency, even under partial shading conditions. The system architecture only deals with the power differences among the PV panels, which reduces the power capacity of the converters. Therefore, the DPP systems can easily overcome the conventional disadvantages of PCS such as centralized, string, and module integrated converter (MIC) topologies. Among the various types of the DPP systems, the feed-forward method has been selected for both its voltage balancing and power transfer to a modified H-bridge inverter that needs charge balancing of the input capacitors. The modified H-bridge multi-level inverter had some advantages such as a low part count and cost competitiveness when compared to conventional multi-level inverters. Therefore, it is frequently used in photovoltaic (PV) power conditioning system (PCS). However, its simplified switching network draws input current asymmetrically. Therefore, input capacitors in series suffer from a problem due to a charge imbalance. This paper validates the operating principle and feasibility of the proposed topology through the simulation and experimental results. They show that the input-capacitor voltages maintain the voltage balance with the PV MPPT control operating with a 140-W hardware prototype.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

일-가정 균형을 위한 지역사회의 자녀 돌봄 지원 실태에 대한 연구 -서울, 경기지역 맞벌이 가정을 중심으로 (The Study on Supporting Situation of the Community Child Care Service for the Work-Family Balance - Focused on Dual Income Families Living in Seoul and Gyeonggi Province)

  • 조성은;정지영;한지수
    • 가족자원경영과 정책
    • /
    • 제13권1호
    • /
    • pp.147-168
    • /
    • 2009
  • The purpose of this study is to research support systems of the community child care services for optimum work-family balance. For this purpose, the questionnaire to be completed combined four areas: the workplace, school, community and home. Then questions concerning demographic factors and community-related aspects were analysed for this article. After analyzing 197 questionnaires, supplementary questions were asked, by interview to 10 samples. Full-time working wives (eg. working from 9am to 6pm) who have 1 or more children under 10 years old, living in Seoul and Gyeonggi province were collected as samples. The results were as follows: First, child care from family and relatives, and community services was properly used during the week, but dual working parents took complete charge of child care on Saturdays. Second, emergency child care was usually provided by the family, while relatives and community child care services were used less. Third, parents spent 17% of their monthly income on total child care expenditure. Fourth, community child care services were not used often, but the level of satisfaction with them was very high. Finally, they used relatives' services for safety reasons and community services for location, and only based on informed decisions. Therefore, Saturday child care programmes need to be initiated to help physically and mentally tired parents, with more general provision of positive and diverse public support systems.

  • PDF

EML doping 위치에 따른 적색 인광 OLED 특성 변화 연구

  • 현영환;최병덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.230.1-230.1
    • /
    • 2016
  • 본 연구에서는 Host-Dopant system 기반 적색 인광 OLED의 Emitting layer(EML)에서 doping 위치에 따른 특성 변화를 분석하였다. EML은 host 물질로 60 nm 두께의 CBP를 사용하고, 적색 발광을 위해 10 %의 $Ir(btp)_2$를 CBP의 Front, Middle, Back side에 각각 20 nm씩 doping하였다. 본 구조의 적색 인광 OLED는 current density, luminance, efficiency, EL spectrum 등을 통해 전기적, 광학적 특성 변화를 확인하였다. Front, Back side에 doping으로 인한 CBP의 Energy level이 3.6 eV에서 1.9 eV로 감소하여 각각 HTL/EML, EML/HBL의 경계에 carrier direct injection이 활성화 되었고, 이로 인한 charge balance의 저하를 확인하였다. EL spectrum결과 각 소자는 CBP의 618 nm 파장 외에도, 추가적으로 TPBi의 398 nm, NPB의 456 nm의 파장을 보였다. 이를 통해 doping 위치에 따라 exciton이 형성되는 recombination zone이 이동하고 있음을 확인하였고, Front side는 6 V의 인가전압에서는 발광 파장이 398 nm에서 높은 값을 보이나 8 V, 10 V, 12 V에서 618 nm에서 높은 값을 보이는 것으로 인가전압에 의해 recombination zone이 HTL쪽으로 이동되는 것 또한 확인하였다.

  • PDF

이중촉매 MEA의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Double-Layered Catayst MEA)

  • 김홍건;강성수;곽이구;강영우
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.50-59
    • /
    • 2006
  • An experimental and numerical study is carried out to investigate the performance and the efficiency humidifying Membrane Electrolyte Assembly and having the double-layered catalyst in a fuel cell system which is taken into account the physical and thermal concept. Based on the principals of the problem, the equation of electronic charge conservation equation, gas-phase continuity equation, and mass balance equation are used for the numerical calculation. A unit cell for $200cm^2$ MEA is assembled and measured for finding better operational situation. After finding the optimal condition, 10 cell stacked PEMFC is fabricated. For the performance evaluation, V-I and power curves are examined in detail by changing the condition of humidity, temperature, pressure, thickness of catalyst and oxidant. It is found that the power is maximized around 500W at 80A.

  • PDF

Effect of Discharging Process on Electrical and Optical Properties in Charged Particle-type Reflective Electronic Display

  • Kim, Young-Cho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권6호
    • /
    • pp.333-337
    • /
    • 2014
  • In this study, the use of a discharging process for charged particles is proposed to achieve an ideal electrical balance or neutralization and to improve the electrical and optical properties of a reflective electronic display. Here, negatively charged particles (white) and positively charged particles (black) are used. The q/m (charge per mass for a particle) values of the black and white particles are $+4.5{\mu}C/g$ and $-4.5{\mu}C/g$, respectively. We compared the movement of the charged particles by varying their discharging time. Stable movement of the charged particles is obtained with an appropriate discharging time, which resulted in improvements of the optical properties of the panel.

Formation and Physical Properties of Yogurt

  • Lee, W.J.;Lucey, J.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권9호
    • /
    • pp.1127-1136
    • /
    • 2010
  • Yogurt gels are a type of soft solid, and these networks are relatively dynamic systems that are prone to structural rearrangements. The physical properties of yogurt gels can be qualitatively explained using a model for casein interactions that emphasizes a balance between attractive (e.g., hydrophobic attractions, casein cross-links contributed by calcium phosphate nanoclusters and covalent disulfide cross-links between caseins and denatured whey proteins) and repulsive (e.g., electrostatic or charge repulsions, mostly negative at the start of fermentation) forces. Various methods are discussed to investigate the physical and structural attributes of yogurts. Various processing variables are discussed which influence the textural properties of yogurts, such as total solids content, heat treatment, and incubation temperatures. A better understanding of factors contributing to the physical and structural attributes may allow manufacturers to improve the quality of yogurt.