• Title/Summary/Keyword: Characteristics of M&A

Search Result 16,848, Processing Time 0.052 seconds

A Study on Cutting Characteristics Evaluation of High Speed Feeing Type Laser Cutting M/C (고속 이송 방식 Laser Cutting M/C의 절단성 평가에 관한 연구)

  • 이춘만;임상헌
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1820-1823
    • /
    • 2003
  • A high speed feeding type laser cutting M/C is developed for precise cutting of sheet metal. This paper has been carried out to obtain cutting characteristics and optimal cutting conditions of the developed high speed feeding type laser cutting M/C by a design of experiments. Cutting speed. laser power. laser duty and gas pressure are control factors for the surface roughness. The major factors affecting the surface roughness and the optimum cutting conditions are studied with minimum experiments using Taguchi method.

  • PDF

A Study on the Architectural Characteristics and Planning for the Wards in A.F.M.H. - Focused on Case Studies - (군 통합병원 병동부의 건축적 특성과 계획에 관한 연구 - 사례분석을 중심으로 -)

  • Kim, Ho-Young;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.5 no.9
    • /
    • pp.69-79
    • /
    • 1999
  • Now new A.F.M.H. is under construction but it didn't reflect army hospital's characteristics. The purpose of this study was to get the design guidelines of the wards for the design of wards in army hospital. This research is accomplished through an understanding of the characteristics of wards in army hospitals by analyzing the plans of the bundang A.F.M.H. and behavior survey of other A.F.M.H. This study attempts to examine the current status of domestic and to establish the design guideline of the wards of the army hospitals.

  • PDF

Optical Pulse Compression at $1.319{\mu}m$ Through Fiber-grating Pair (광섬유와 회절격자를 이용한 $1.319{\mu}m$ 파장 광펄스의 압축)

  • 이재승;박희갑;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.13-19
    • /
    • 1991
  • Utilizing self-phase modulation effects of a dispersion-shifted fiber and delayline characteristics of two gratings, mode-locked 80 ps pulses at 1.319 $\mu \textrm m$ wavelength from a Nd:YAG laser are compressed to 2.1 ps. This experiment is suitable for studying the transmission characteristics of high energy short pulses along normal fibers in zero dispersion regime.

  • PDF

An Empirical Study on the Factors Affecting the Intention to Use M2E Services

  • Sang Hoon Lee;Min-Ju Kim;Su-Yeon Kim
    • Asia pacific journal of information systems
    • /
    • v.33 no.3
    • /
    • pp.792-811
    • /
    • 2023
  • Recently, Web 3.0 services such as virtual currency, block chain, and NFT are attracting public attention. Users who depended on platforms are moving away from being dependent on service providers and moving to Web 3.0 services. Representative services of Web 3.0 include P2E (Play to Earn) and M2E (Move to Earn). In the case of P2E, various studies have been conducted as it is widely covered in the press and media, but research on M2E is relatively lacking. This study attempts to identify the intention to use M2E by using the expanded technology acceptance model. External factors were selected based on M2E's own characteristics and personal characteristics, a research model was designed, and the proposed hypotheses were verified through factor analysis and goodness of model fit. As a result of the study, it was confirmed that profitability, innovativeness, and self-expression had a positive effect on perceived characteristics, and that perceived usefulness, perceived enjoyment, and social influence had a positive effect on intention to use. Through the research results, practical implications for efficient service operation that meets the needs of users are presented to M2E platform providers.

Analysis of MODFET Transport using Monte-Carlo Algorithm ` Gate Length Dependent Characteristics (몬테칼로 알고리즘을 이용한 MODFET소자의 전달특성분석;채널길이에 따른 특성분석)

  • Hak Kee Jung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.4
    • /
    • pp.40-50
    • /
    • 1993
  • In this paper, MODFET devices with various gate length are simulated using the Monte-Carlo method. The number of superparticle is 5000 and the Poisson equation is solved to obtain field distribution. The structure of MODFET is n-AlGaAs/i-AlGaAs/iGaAs and doping concentration of n-AlGaAs layer is 1${\times}10^{17}/cm^{3}$ and the thickness is 500.angs., and the thickness of i-AlGaAs is 50$\AA$. The devices with gate length 0.2$\mu$m, 0.5$\mu$m, 1.0$\mu$m respctively are simulated and the current-voltage curves and transport characteristics of that devices are obtained. Occupancy of each subband and electron energy distribution and conduction energy band in channel have been analyzed to obtain transport characteristics, and particles transposed from source to drain have been analyzed to current-voltage curves. Current level is highest for the device of Lg=0.2$\mu$m and transconductance of this device is 310mS/mm.

  • PDF

Implementation of Low Noise p-HEMT Using Spin processor (Spin processor에 의한 저잡음 p-HEMT 제작)

  • Kim, Song-Gang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.148-152
    • /
    • 2001
  • One set of MMIC library has been developed using gate recess etching by spin processor. It is superior than that of dipping Method in the uniformity and the reproducibility of gate recess. A DC characteristics of p-HEMT have a uniform characteristics in the whole wafer than that of dipping method. The low noise p-HEMT with the $0.6{\mu}m$ and $200{\mu}m$ of gate length and gate width, respectivily, has a uniform characteristics of Idss 130~145 mA, conductances 190~220mS/nm, and threshold voltage -0.7~-1.1V in the drain voltage of 2V.

  • PDF

Light and electron microscopical characteristics of Perkinsus sp. from Manila clam, Ruditapes philippinarum, in Korea

  • Ahn Kyoung Jin;Huh Sung-Hoi;Kim Ki Hong
    • Fisheries and Aquatic Sciences
    • /
    • v.3 no.3_4
    • /
    • pp.205-212
    • /
    • 2000
  • Light and electron microscopical characteristics of Perkinsus sp. parasitizing in Manila clam, Ruditapes philippinarum, in Korea were investigated. Trophozoite within the tissue was spherical or ovoid and ranged $2.5-10.5\mu m$ $(mean = 6.2\mu m)$ in diameter. Trophozoite had a nucleus with a prominent nucleolus and a large cytoplasmic vacuole within the cytoplasm. Single trophozoite was phagocytozed by host hemocyte and cluster cells were encapusulated by hemocytes aggregation within the host tissues. Hypnospores incubated in thioglycollate medium (FTM) for 1 to 15 days were also spherical or ovoid and ranged $10-132\mu m$ $(mean\pm S.D.\;:\;44.25\pm 7.91\mu m)$ in diameter. Zoospores were spherical or ovoid, had a nucleus and two flagella. Zoospores contained apical complex, which consisted of conoid, subpellicular microtubules, rhoptries and rectilinear micronemes.

  • PDF

Study on Thermal Characteristics of Smart LED Driver ICs Package (일체형 스마트 LED Driver ICs 패키지의 열 특성 분석)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2016
  • This research was analyzed thermal characteristics that was appointed disadvantage when smart LED driver ICs was packaged and we applied extracted thermal characteristics for optimal layout design. We confirmed reliability of smart LED driver ICs package without additional heat sink. If the package is not heat sink, we are possible to minimize package. For extracting thermal loss due to overshoot current, we increased driver current by two and three times. As a result of experiment, we obtained 22 mW and 49.5 mW thermal loss. And we obtained optimal data of 350 mA driver current. It is important to distance between power MOSFET and driver ICs. If thhe distance was increased, the temperature of package was decreased. And so we obtained optimal data of 3.7 mm distance between power MOSFET and driver ICs. Finally, we fabricated real package and we analyzed the electrical characteristics. We obtained constant 35 V output voltage and 80% efficiency.

A Study on the Effects of Rotation Rate and Flow Rate on the Operating Characteristics in Centrifugal Pump (원심펌프에서 회전수 및 유량변화가 운전특성에 미치는 영향)

  • Lim, Kwang-Mook;Lee, Sung-Ill
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.56-62
    • /
    • 2019
  • This study examined effects of the operating characteristics of a pump according to the rotational speed of a pump and the change in flow rate when a centrifugal pump operates under the following conditions: regulated flow rate, head, rotational speed, and specific speed of 0.7 m/min, 8 m, 1750 rpm, an 182 (m, ㎥/min, rpm), respectively. The pump in the experiment did not have a guide vane and was connected directly to the rim, so that the rotational speed of the volute pump in a spiral or volute casing increased by 100 rpm from 1350 to 1750 rpm. The result of the relationship between the H-Q, L-Q, and 𝜂-Q characteristics and the dimensionless performance characteristics, such as the head coefficient, power coefficient and efficiency were studied. The change in pump performance could be estimated depending on the increase in the number of revolutions. The maximum efficiency of the pump was 52% with 1450 rpm, 0.165 ㎥/min flux, and 4.73 m of lift. The efficiency reached 50% with a maximum of 1750 rpm, 0.183 ㎥/min of flux, and 6.72 m of lift. The efficiency curve on the performance characteristics of the lift versus flux curve became oval not a curve from a quadratic equation that passes through the starting point according to the similarity law of the pump. Finally, when the flux coefficient increased, the power coefficient increased and the lift coefficient decreased. When the flux coefficient was 0.08, the maximum efficiency was 52%. Therefore, the change in flux affects the driving characteristics.

A Study of Caregiver Stress as related to the Level of Self-care in Patients Who had a Cerebro Vascular Accident(CVA) (뇌졸중환자의 자가간호 수준에 따른 보호자의 스트레스)

  • 최은숙;소희영
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.602-616
    • /
    • 1993
  • The purpose of this study was to explore the degree of stress in caregivers caring for patients who had had a cerebro vascular accident as the stress is related to the self- care ability of the patient. The subjects for the study were caregivers of 111 CVA patients, hospitalized at two University affiliated hospitals and two general hospitals in Daejon. The survey instruments used in the study were Kang’s ADL Check List and a modified form of Lee’s Stress Inventory. The survey was conducted from July 16th to August 30th, 1992. The survey results were analyzed using the Statisitical Package for Social Sciences (SPSS) and can be sumerized as follows: 1. The level of self- care for the CVA patients was : 1) complete dependence (M=34.7, 31.2%), 2) complete independence (M=14.8. 13.3%), 3) in-complete independence ( M=17.5, 15.8% ), 4) in-complete dependence (M=14.8, 13.3%) and 5) dependence and independence (M=14.1, 12.7%). The items for which there was a high level of self-care were 1) drinking (M=3.640), 2) returning (M=2.351) and 3) eating (M=2.351) : and the items for which there was a low level of self -care were : 1) ascending and descending stairs (M=2.351), 2) dressing and undressing trousers (M=2.514) and 3) dressing and undressing jacket (M :2.532). 2. There was a statistically difference between the paralytic status and the level of self- care accord-ing to their demographic characteristics ( F=24. 7056, p(.001). 3. There was no significant difference in the degree of caregiver stress according to patient's demo-graphic characteristics. 4. There was a statistically significant difference in the degree of caregiver stress according to the following demographic characteristics : age (F=7.4189, p(.001), education level (F=5.8336, P(.01), family structure (t=2.10, p(.05) and their relationship with the patient (F=6.5099, P〈.01). 5. There was no significant difference in the degree of caregiver stress according to the level of patient self - care.

  • PDF