• 제목/요약/키워드: Characteristic chart

검색결과 92건 처리시간 0.023초

건물의 전기부하특성에 따른 BIPV시스템의 부하매칭에 관한 연구 (A Study on BIPV system generation matching by electricity load characteristic of Building)

  • 박재완;신우철;김대곤;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.67-74
    • /
    • 2013
  • These days, although thermal energy is decreasing, electric energy is increasing in building. Also, it is very important to research and distribute BIPV(Building Integrated photovoltaic) because our society consider electricity more significant than other energy in building. Therefore, in this paper, our research team analyzed difference between BIPV yield and building energy consumption through experimental research. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV. As a result, yearly building energy consumption was 104,602.4kWh and BIPV yield was 105,267kWh. And then, totally counterbalanced time took up 26%, reduced electric load time took up 16%. In other words, peak load could be reduced up to 42% by BIPV.

Prediction of medication-related osteonecrosis of the jaw (MRONJ) using automated machine learning in patients with osteoporosis associated with dental extraction and implantation: a retrospective study

  • Da Woon Kwack;Sung Min Park
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권3호
    • /
    • pp.135-141
    • /
    • 2023
  • Objectives: This study aimed to develop and validate machine learning (ML) models using H2O-AutoML, an automated ML program, for predicting medication-related osteonecrosis of the jaw (MRONJ) in patients with osteoporosis undergoing tooth extraction or implantation. Patients and Methods: We conducted a retrospective chart review of 340 patients who visited Dankook University Dental Hospital between January 2019 and June 2022 who met the following inclusion criteria: female, age ≥55 years, osteoporosis treated with antiresorptive therapy, and recent dental extraction or implantation. We considered medication administration and duration, demographics, and systemic factors (age and medical history). Local factors, such as surgical method, number of operated teeth, and operation area, were also included. Six algorithms were used to generate the MRONJ prediction model. Results: Gradient boosting demonstrated the best diagnostic accuracy, with an area under the receiver operating characteristic curve (AUC) of 0.8283. Validation with the test dataset yielded a stable AUC of 0.7526. Variable importance analysis identified duration of medication as the most important variable, followed by age, number of teeth operated, and operation site. Conclusion: ML models can help predict MRONJ occurrence in patients with osteoporosis undergoing tooth extraction or implantation based on questionnaire data acquired at the first visit.

Pressure drop characteristics of concentric spiral corrugation cryostats for a HTS power cable considering core surface roughness

  • Youngjun Choi;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.19-24
    • /
    • 2023
  • Recently, interest in renewable energy such as solar and wind power has increased as an alternative to fossil fuels. Renewable energy sources such as large wind farms require long-distance power transmission because they are located inland or offshore, far from the city where power is required. High-Temperature Superconducting (HTS) power cables have more than 5 times the transmission capacity and less than one-tenth the transmission loss compared to the existing cables of the same size, enabling large-capacity transmission at low voltage. For commercialization of HTS power cables, unmanned operation and long-distance cooling technology of several kilometers is essential, and pressure drop characteristic is important. The cryostat's spiral corrugation tube is easier to bend, but unlike the round tube, the pressure drop cannot be calculated using the Moody chart. In addition, it is more difficult to predict the pressure drop characteristics due to the irregular surface roughness of the binder wound around the cable core. In this paper, a CFD model of a spiral corrugation tube with a core was designed by referring to the water experiments from previous studies. In the four cases geometry, when the surface roughness of the core was 10mm, most errors were 15% and the maximum errors were 23%. These results will be used as a reference for the design of long-distance HTS power cables.

향기가 강한 연노랑색 겹꽃 프리지아 '스윗레몬(Sweet Lemon)' 육성 (Double Flower Freesia 'Sweet Lemon' with Strong Fragrance)

  • 최윤정;정향영;구대회;강윤임;이영란
    • 화훼연구
    • /
    • 제26권4호
    • /
    • pp.216-220
    • /
    • 2018
  • 프리지아 'Sweet Lemon'은 2007년 농촌진흥청 국립원예특작과학원에서 흰색 겹꽃 'Teresa'품종과 노랑색 반겹꽃 'Yvonne'품종을 교배하여 획득한 종자로부터 2007년 연노랑색 향기가 강한 겹꽃 프리지아 계통을 선발하여 품종으로 개발되었다. 2008년부터 2014년까지 개화 생육특성검정 및 육성계통평가회의 기호도 평가를 통해 선발되어 2015년 'Sweet Lemon' 으로 명명되었다. 'Sweet Lemon'은 연노랑색(RHS color chart Y2B) 겹꽃 프리지아 품종으로 화폭은 6.8cm이며 분지수는 6.7개로 다수확성 품종이다. 초장은 99cm로 초세가 강하며 대조품종 'Yvonne' 91.7cm에 비해 34.7cm 더 크다. 'Sweet Lemon'의 소화수 및 소화장은 각각 10.7개, 7.7cm로 'Yvonne' 9.7개, 8.3이며 개화소요일수는 126일로 대비품종 보다 약 20일 정도 빠르다. 이 품종의 절화수명은 약 8.7일이며 자구번식력은 5.6배로 대조품종에 비해 우수하다. GC/MS를 이용한 향기분석 결과 총 58개의 방향성 화합물이 검출되었으며 주요성분은 linalool, alpha-Terpineol, alpha-Selinene, limonene이었다.

메틸나이트로이미다졸 유도체의 성능-감도 이차원적 분석 (Two dimensional analysis between the performance and the sensitivity of methylnitroimidazole derivatives)

  • 임완권
    • 분석과학
    • /
    • 제28권6호
    • /
    • pp.430-435
    • /
    • 2015
  • 메틸나이트로이미다졸계 유도체들에 관한 화약 성능과 충격감도 간의 이차원 분석이 이들 물질의 효용성을 판단하기 위해 진행되었다. 화약 성능은 Cheetah 프로그램으로 계산되었으며, 충격감도는 인공신경망 연구로 예측했다. 연속적인 나이트로기의 치환이 분자들을 민감하게 하지만 메틸트라이나이트 이미다졸까지도 비교적 안전한 상태를 유지하는 것으로 예측된다. 최근에 국방과학연구소에서는 성능과 감도를 X, Y축에 도시하고 신규화약물질의 유용성을 전체적으로 분석하는 방안을 개발하였다. 이들 성능-감도 이차원 그래프에 따르면 메틸다이나이트로이미다졸계 유도체들은 둔감화약조성에 사용이 가능할 것으로 판단되고, 반면 메틸트라이나이트로이미다졸은 고폭화약조성에 사용할 수 있을 것으로 판단된다.

Respiratory Severity Score as a Predictive Factor for the Mortality of Congenital Diaphragmatic Hernia

  • Ahn, Ja-Hye;Jung, Young Hwa;Shin, Seung Han;Kim, Hyun-Young;Kim, Ee-Kyung;Kim, Han-Suk
    • Neonatal Medicine
    • /
    • 제25권3호
    • /
    • pp.102-108
    • /
    • 2018
  • Purpose: Congenital diaphragmatic hernia (CDH) is rare but potentially fatal. The overall outcome is highly variable. This study aimed to identify a simple and dynamic parameter that helps predict the mortality of CDH patients in real time, without invasive tests. Methods: We conducted a retrospective chart review of 59 CDH cases. Maternal and fetal information included the gestational age at diagnosis, site of defect, presence of liver herniation, and lung-to-head ratio (LHR) at 20 to 29 weeks of gestational age. Information regarding postnatal treatment, including the number of days until surgery, the need for inhaled nitric oxide (iNO), the need for extracorporeal membrane oxygenation (ECMO), and survival, was collected. The highest respiratory severity score (RSS) within 24 hours after birth was also calculated. Results: Statistical analysis showed that a younger gestational age at the initial diagnosis (P<0.001), a lower LHR (P=0.001), and the presence of liver herniation (P=0.003) were prenatal risk factors for CDH mortality. The RSS and use of iNO and ECMO were significant factors affecting survival. In the multivariate analysis, the only remaining significant risk factor was the highest preoperative RSS within 24 hours after birth (P=0.002). The area under the receiver operating characteristic curve was 0.9375, with a sensitivity of 91.67% and specificity of 83.87% at the RSS cut-off value of 5.2. The positive and negative predictive values were 82.14% and 92.86%, respectively. Conclusion: Using the RSS as a prognostic predictor with simple calculations will help clinicians plan CDH management.

경주 및 포항 지역에서 발생한 쯔쯔가무시병에 관한 연구 - 항체 유무를 중심으로 - (A Case-Control, Restrospective Study on Tsutsugamushi Disease Occurred in Gyeongju and Pohang Provinces, Korea)

  • 백설향
    • 농촌의학ㆍ지역보건
    • /
    • 제29권1호
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives: Tsutsugamushi disease is one of the most significant acute febrile illnesses, increasing in frequency of occurrence during the late autumn in rural areas of Korea. Methods: I have conducted a case-control study on 30 cases who had the fever as a chief complaint, then had been ruled out as having the Tsutsugamushi disease. Data was collected retrospectively by review of chart regarding their general characteristics, clinical and laboratory findings, then was analysed by chi-test. Results: Of 30 cases, 16 cases were seropositive and 14 cases were seronegative against O. tsutsugamushi. Of seropositive for tsutsugamushi disease, 56.3% were female; 37.5% were in their seventies; 50.0% were farmers; 62,6% had chances of exposure to fields or mountains. And 75.0% occurred in November. The main symptoms and signs were fever and chill(100.0%), headache(75.0%). weakness and fatigue(93.8%), and eschar(68.8%). The characteristic laboratory findings were elevated AST(50.0%), ALT(62.5%), and abnormal urinalysis(56.3%). On the other hand, of seronegative cases, 57.1% were male; 50.0% were in their fifties; 42.9% were farmers; 57.2% had chances of exposure to fields or mountains. And 71.4% occurred in November. The symptoms and signs were fever and chill(100.0%), headache(85.7%), eschar(64.3%). weakness, fatigue and skin(57.1%). The laboratory findings were elevated AST(71.4%) and ALT(64.3%), and abnormal urinalysis(42.9%). However, there were no significant differences between the seropositive and seronegative cases(P>.05). Conclusions: Acute febrile community inhabitants who have the epidemiological, clinical as well as laboratory features should be focused upon for the early diagnosis and treatment for tsutsugamushi disease whether or not possessing the serological antibody against O. tsutsugamushi.

  • PDF

일반병동 내 중증 패혈증 또는 패혈성 쇼크 환자의 중환자실 전동 예측에 대한 수정조기경고점수(Modified Early Warning Score)의 타당성 (Validation of a Modified Early Warning Score to Predict ICU Transfer for Patients with Severe Sepsis or Septic Shock on General Wards)

  • 이주리;최혜란
    • 대한간호학회지
    • /
    • 제44권2호
    • /
    • pp.219-227
    • /
    • 2014
  • Purpose: To assess whether the Modified Early Warning Score (MEWS) predicts the need for intensive care unit (ICU) transfer for patients with severe sepsis or septic shock admitted to general wards. Methods: A retrospective chart review of 100 general ward patients with severe sepsis or septic shock was implemented. Clinical information and MEWS according to point of time between ICU group and general ward group were reviewed. Data were analyzed using multivariate logistic regression and the area under the receiver operating characteristic curves with SPSS/WIN 18.0 program. Results: Thirty-eight ICU patients and sixty-two general ward patients were included. In multivariate logistic regression, MEWS (odds ratio [OR] 2.02, 95% confidence interval [CI] 1.43-2.85), lactic acid (OR 1.83, 95% CI 1.22-2.73) and diastolic blood pressure (OR 0.89, 95% CI 0.80-1.00) were predictive of ICU transfer. The sensitivity and the specificity of MEWS used with cut-off value of six were 89.5% and 67.7% for ICU transfer. Conclusion: MEWS is an effective predictor of ICU transfer. A clinical algorithm could be created to respond to high MEWS and intervene with appropriate changes in clinical management.

해도분석을 통한 낙동강 하구 사주 면적의 시.공간 변화 (Spatiotemporal Changes of the Sand Barrier using Marine Charts Analysis in the Nakdong River Estuarine)

  • 유창일;윤한삼;류청로;이인철
    • 한국해양공학회지
    • /
    • 제20권6호
    • /
    • pp.54-60
    • /
    • 2006
  • This study discusses characteristic of spatiotemporal changes of the sand barrier in the Nakdong estuarine for the last century, focusing on geomarphologic evolution and mobility of sand barriers in the view of coastal engineering. The Nakdong estuarine, the research subject, has a complexly changing natural environment by interaction between ground and marine elements such as ocean wave, tidal current, sediment, etc. Moreover, recently, unnatural geomorphologic changes (e.g., seaside reclamation, new harbor construction, etc.) has been radically increased in this area with increasing desire for coastal development. Because of this, its sand barrier has developed quite unstable condition. Therefore, to identify the development process of geomorphologic changes in this area, required is a close examination on historical characteristics of spatiotemporal changes of the sand barrier in relation to surrounding seaside reclamation and physical environmental changes. This study, based on the marine charts published in between 1927 and 1995 year, analyzes the length and area of the sand barrier for the last hundred years, and investigates the cause of the changes by looking into the change of water depth for the last two years and doing ocean-physical site observations. In conclusion, the sand barrier of the Nakdong estuarine expands toward the open sea by $7.4{\sim}26m$ in annual average, maintaining a fixed distance of $1,241{\sim}1.279m$, and its area is expected to increase about $2.8km^2$ annually. This is characterized by the wocean wave from the open sea and the discharge of Nakdong River.

기능적인 하지길이 차이에 따른 족저압 변화가 족부체열에 미치는 영향 (The Foot Pressure Change Caused by Functional Leg Length Having an Effect on the Foot Temperature)

  • 김민주;김주연;이혜원;임주연;하현진;안진호
    • 대한통합의학회지
    • /
    • 제1권2호
    • /
    • pp.37-46
    • /
    • 2013
  • Purpose : The purpose of the research was to analyze foot pressure, foot temperature, and correlation between foot pressure and foot temperature to grasp impact on foot pressure and body temperature distribution chart depending on functional difference of leg length. Method : After measuring leg length, put 15 students whose functional difference of leg length was over 10mm to difference group and 15 students whose functional difference of leg length was under 5mm to normal group and categorize soles of foot into 6 sections of hallux head, 1st metatarsal head, 2-4 metatarsal head, 5 metatarsal head, lateral heel, and then measure by foot pressure analyzer to analyze characteristic of pressure distribution and classify into front of the lower leg, back of the lower leg, soles of foot and measure by body temperature analyzer to analyze by checking body temperature. Result : Weight difference depending on foot pressure and body temperature was bigger when functional difference of leg length was bigger, and it could be confirmed that foot pressure and body temperature of short leg side were higher than those of short leg side. Thus, if difference exists in leg length, weight load on short leg side increases which results in higher foot pressure and body temperature, therefore enabling an assumption that mechanical problem will occur in short leg. Conclusion : When functional leg length inequality, weight bearing and pressure was getting high as a result, temperature was getting high in short leg.