Parametric Modeling and Numerical Simulation of 3-D Woven Materials (3차원 엮임 재료의 파라메트릭 모델링 및 수치적 재료 특성 분석)

  • Sim, Kichan;Ha, Seung-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.331-338
    • /
    • 2020
  • In this study, the characteristic of a 3-D micro-woven material, which is one of the newly developed periodic open-cell structure, is analyzed through various computational simulations. To increase the accuracy of the numerical simulations, the distance between each directional wire is parameterized using six design variables, and its model geometry is precisely discretized using tetrahedron elements. Using the improved computational model, the material properties of the mechanical, thermal, and fluidic behavior are investigated using commercial software and compared with the previous experimental results. By changing the space between the x- and y-directional wires, a parametric test is performed to determine the tendency of the change in the material properties. In addition, the correlation between two different material properties is investigated using the Ashby chart. The result can further be used in determining the optimal pattern and wire spacing in 3-D micro-woven materials.

An Analysis on Co-relationships Between In-situ Investigation Methods and End Bearing Capacity of A Drilled Shaft Socketed into the Weathered Zone (풍화대소켓 현장타설말뚝의 극한단위선단지지력과 원위치 지반조사방법들과의 상관관계 분석)

  • Choi, Yongkyu;Kwon, Oh Sung;Lee, Jong Seong;Choi, Sung Soon;Jung, Sung Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.95-107
    • /
    • 2010
  • To calculate the end bearing capacity of a drilled Shaft socketed into the rockmass, the unconfined compression strength could be used. But it is difficult to find the unconfined compression strength because it is impossible to get undisturbed samples in weathered soils and rocks. So, to calculate the end bearing capacity, the existing bearing formula could not be used. In this study, for five zones (near pile tip, tip~lower 1D, tip~lower 2D, upper 1D~lower 1D, upper 1D~lower 2D), the relationships between the characteristic values of in-situ tests(SPT, DCPT PMT, BST) and the end bearing capacity of drilled shafts were analysed. As a result, DCPT results were represented the best credibility. Also, a design chart of end bearing capacity using DCPT was suggested.

CTQ derived using the new Module device convergence and QFD can be mounted on the dominance Products : Focusing on the sparkling water purifier Case (시장지배제품에 장착 가능한 새로운 Module장치 융합 및 QFD를 활용한 CTQ 도출 : 탄산수 정수기 사례를 중심으로)

  • Song, In-Cheol;Hwang, Dong-Ryong;Lee, Seung-Hee
    • Journal of Digital Convergence
    • /
    • v.13 no.5
    • /
    • pp.195-204
    • /
    • 2015
  • This paper CTQ(Critical to Quality) to draw, aim to derive a key quality factor reflects the customer's requirements by utilizing the QFD technique for sparkling water purifier device that combines the new module. Tasting participants, consumers and New Module device intended for developers who develop and conduct a survey and FGI (Focus Group Interview) VOC(Voice of Customer) to draw, drawn by the EC through the developer VOC and EC (Engineering Characteristic) and charts the relationship between the phases was prepared HOQ(House of Quality). Sparkling water purifier through the HOQ chart certain taste, sound, running water, CO2 cylinder replacement cycle, we obtain results that element is an important quality factors such as ease of use. These factors are closely related to each component regulators and Module device (mixing) associated with the taste of water, booster pumps, and deliver results that the solenoid is considered the most critical part.

Evaluation of Automatic Exposure Control Systems (X선자동노출(X線自動露出) 제어장치(制御裝置)에 관한 검토(檢討))

  • Kim, Chung-Min;Kim, Keon-Chung;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • Automatic exposure control systems are now readily available and widly used in radiography. A device that automatically determines the amount of radiation required to produce an acceptable level of film blackness is called a phototimer, or automatic exposure control. There are limitations in the use of phototimers ; however, equipment can be used much more effectively if one recognize these limitations, and the goal of obtaining a properly exposed, reproducible radiography can be achieved. We have some results in this experimental study. The variations of film density due to kVp are in propotion to below 80 kVp range. But indicate constant level above 80 kVp to 120 kVp. The characteristic density variation by phantom thickness shows the higher the thiner in exit type. AEC system have a density control that is designed to make adjustments increase or decreas the density 10% per step or 25% per step. The automatic exposure control circuits must meet the several regulations of the HEW. Some forms of technique chart is recomened for use of AEC.

  • PDF

Microwave Properties of High Tc Superconducting Microstrip Antenna with Temperature Dependence (고온초전도 마이크로스트립 안테나의 온도 종속 초고주파 특성)

  • Chung, Dong-Chul;Choi, Myung-Ho;Kang, Hyeong-Gon;Lim, Sung-Hun;Han, Byoung-Sung
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.124-128
    • /
    • 1999
  • We report microwave properties of high-T$_c$ superconducting (HTS) microstrip antennas without impedance matching circuits, where the impedance mismatching is obvious under the critical temperature (T$_c$). The superconducting thin films used in this report were YBa$_2Cu_3O_{7-x}$ (YBCO) films deposited on MgO substrates produced by pulse laser deposition (PLD) technique. At around T$_c$, 86 K the reflection coefficient rapidly drops, and the standing wave ratio (SWR) becomes almost unity, and the characteristic impedance based on the Smith chart is nearly 50 ${\Omega}$. The reflection coefficient and the SWR of the HTS microstrip antenna were - 62.52 dB and 1.0015, respectively, at the resonant frequency of 11.812 CHz at 86 K.

  • PDF

A Study on the Calculation Model for the Emissivities of Carbon Dioxide and Water Vapor

  • Kim, Chong-Bo;Hur, Byung-Ki;Kim, Nam-Jin;Seo, Tae-Beom
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.248-258
    • /
    • 2001
  • The main mode of heat transfer of combustion gases at high temperature is thermal radiation of the participating gases, which are mainly carbon dioxide and water vapor. Therefore, the information of the emissivities of carbon dioxide and water vapor would be very important in the thermal performance analysis of a furnace. In this study, an exponential model for the emissivities of carbon dioxide and water vapor is derived as a function of the product of the partial pressure and characteristic length and a polynomial of reciprocal of temperature. Error analysis of the calculated values from the present model is performed for the temperature ranges of 555.6∼2777.8K and the partial-pressure-length product ranges of 0.09144∼609.6 cm-atm. For carbon dioxide, the difference between the values from the present model and the Hottels chart is less than 2.5% using a polynomial in 1/T of degree of 4. For water vapor, the model can predict the emissivity within 2.5% difference using a polynomial in 1/T of degree of 3.

  • PDF

Vibration Analysis of Shaft with Impeller for Resin Chock Mixing Machine (Resin Chock 교반기용 임펠러가 달린 축의 진동해석)

  • Hong, Do-Kwan;Park, Jin-Woo;Baek, Hwang-Soon;Ahn, Chan-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.970-977
    • /
    • 2008
  • This paper deals with the dynamic characteristics of the shaft with impeller model which is the most important part in developing the resin mixing machine. Through reverse engineering, it is possible to make the shaft with impeller geometry model which is necessary vibration characteristic analysis by commercial impeller. The natural frequency analysis and structural analysis using finite element analysis software are performed on the imported commercial shaft with impeller model. The most important fundamental natural frequency of the shaft with impeller model is around 14.5 Hz, which well agrees with modal testing. The most effective design variables were extracted by ANOM(analysis of means) and pareto chart. This paper presents approximation 2nd order polynomial as design variables using RSM(response surface methodology). Generally, RSM take 2 or 3 design variables, but this method uses 5 design variables with table of mixed orthogonal array. Further more, the analyzed result of the commercial shaft with impeller is to be utilized for the structural design of resin chock mixing machine.

A Study on the Clinical Use of 7-zone-Diagnostic System (2) - the Comparative Analysis of the Rule and the Decipher for each Equipment - (7구역진단기의 임상응용에 대한 고찰 (2) - 각 제품에 따른 원리와 판독의 비교 -)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.11-21
    • /
    • 2006
  • The 7-zone-diagnostic system(ABR-2000, BIO MEDIC 700Plus, CP-6000A, OMD 3000, VEGA-DFM 722) is a diagnostic device which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result charts. And these result represents various characteristic signals are assisted diagnosis and care. These result chart contains disorder flow wave forms and some valuable diagnostic hints or marks. But we have several various products for the 7-zone-diagnostic system. I think that we need the comparative analysis of the general rule and the decipher for each equipment. Because these letters(marks) each product are different, we necessary various plentiful research and suitable statistics in these points. And we must carry out many various research in the future.

  • PDF

Comparison of the Autism Diagnostic Observation Schedule and Childhood Autism Rating Scale in the Diagnosis of Autism Spectrum Disorder: A Preliminary Study

  • Park, Hyung Seo;Yi, So Young;Yoon, Sun Ah;Hong, Soon-Beom
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.29 no.4
    • /
    • pp.172-177
    • /
    • 2018
  • Objectives: We examined the agreement between the Autism Diagnostic Observation Schedule (ADOS) and the Childhood Autism Rating Scale (CARS) in the diagnosis of autism spectrum disorder. Methods: The ADOS and CARS scores of 78 children were retrospectively collected from a chart review. A correlation analysis was performed to examine the concurrent validity between the two measures. Using the receiver operating characteristic (ROC) curve, we determined the optimal cut-off score of the CARS for identifying autism spectrum disorder. Results: The CARS score was significantly correlated with the ADOS score (r=0.808, p<0.001). Taking ADOS as the ideal standard, the optimal cut-off scores of CARS for identifying autism and autism spectrum were 30 and 24.5, respectively. Conclusion: We determined the optimal cut-off scores of CARS for screening and diagnosing autism spectrum disorder.

Selecting the Best Prediction Model for Readmission

  • Lee, Eun-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.4
    • /
    • pp.259-266
    • /
    • 2012
  • Objectives: This study aims to determine the risk factors predicting rehospitalization by comparing three models and selecting the most successful model. Methods: In order to predict the risk of rehospitalization within 28 days after discharge, 11 951 inpatients were recruited into this study between January and December 2009. Predictive models were constructed with three methods, logistic regression analysis, a decision tree, and a neural network, and the models were compared and evaluated in light of their misclassification rate, root asymptotic standard error, lift chart, and receiver operating characteristic curve. Results: The decision tree was selected as the final model. The risk of rehospitalization was higher when the length of stay (LOS) was less than 2 days, route of admission was through the out-patient department (OPD), medical department was in internal medicine, 10th revision of the International Classification of Diseases code was neoplasm, LOS was relatively shorter, and the frequency of OPD visit was greater. Conclusions: When a patient is to be discharged within 2 days, the appropriateness of discharge should be considered, with special concern of undiscovered complications and co-morbidities. In particular, if the patient is admitted through the OPD, any suspected disease should be appropriately examined and prompt outcomes of tests should be secured. Moreover, for patients of internal medicine practitioners, co-morbidity and complications caused by chronic illness should be given greater attention.