• 제목/요약/키워드: Channel Section

검색결과 563건 처리시간 0.021초

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

회전하는 터빈 블레이드 이차유로내 요철 배열이 열/물질전달에 미치는 영향 (Effect of Heat/Mass Transfer in the turbine blade internal passage with various rib arrangement)

  • 이세영;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.22-29
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements and rotating on heat/mass transfer in the cooling passage of gas turbine blades. The cooling passage has very complex flow structure, because of the rib turbulator and rotating effect. Experiments and numerical calculation are conducted to investigate the complex flow structures and heat transfer characteristics; the numerical computation is performed using a commercial code, FLUENT ver.5, to calculate the flow structures and the experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. For the rotating duct tests, the test duct, which is the cross section of is $20mm\times40mm$ (the hydraulic diameter, $D_h$, of 26.7 mm, has two-pass with $180^{\circ}$ turning and the rectangular ribs on the wall. The rib angle of attack is $70^{\circ}$ and the maximum radius of rotation is $21.63D_h$. The partition wall has 10 mm thickness, which is 0.5 times to the channel width, and the distance between the tip of the partition wall and the outer wall of the turning region is 26.7 mm $(1D_h)$. The turning effect of duct flow makes the very complex flow structure including Dean type vortex and high turbulence, so that the heat/mass transfer increases in the turning region and at the entrance of the second pass. The Coriolis effect deflects the flow to the trailing surface, resulting in enhancement of the heat/mass transfer on the trailing surface and reduction on the leading surface in the first pass. However, the opposite phenomena are observed in the second pass. The each rib arrangement makes different secondary flow patterns. The complex heat/mass transfer characteristics are observed by the combined effects of the rib arrangements, duct rotation and flow turning.

  • PDF

STAR 망 TDMA시스템의 계층적 망동기 방식 (Hierarchical Network Synchronization of STAR Network based on TDMA)

  • 윤주현
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권1호
    • /
    • pp.77-84
    • /
    • 2014
  • 본 논문에서는 기존 Star 망 기반의 위성통신 시스템 성능 향상과 기존 시스템과의 하드웨어 호환성을 예상할 수 있는 계층적 망동기 획득 방안을 제안하도록 한다. 여기에서의 시스템 성능이란 시스템 설계 시 대역 효율성과 구현 복잡도 및 모뎀 변복조 성능 간의 관계, 그리고 실제 시스템 적용성의 우수한 정도를 말한다. 제안한 방식은 DVB-S2/RCS 표준을 기반으로 하는 TDM / MF-TDMA(Time Division Multiplexing / Multi-Frequency Time Division Multiple Access) Star 망에서의 단말 시스템이 가지고 있는 높은 하드웨어 복잡도와 비교적 낮은 정확성의 망동기 획득 구조를 보완할 수 있다. 이밖에, 최초에는 위성방송 시스템을 목적으로 설계되었지만 시스템 기능의 업그레이드로 인해 통신 시스템 구조로 변경되어야 하는 경우에 비용 및 성능적인 면에서 높은 효과를 얻을 수 있다. 본문에서는 제안된 망동기 획득방안 알고리즘을 이론적 접근 방식으로 분석하여 구현 복잡도 및 시스템 성능을 예측해보고 그것을 검증하기 위해 컴퓨터 시뮬레이션을 통해 확산율, 심볼율 등의 관련 파라미터와 제어채널의 BER 성능 데이터를 도출하여 실제 시스템에 적용 가능한지를 분석해보도록 한다.

2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험 (Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators)

  • 오명도;유경훈
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF

덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 - (Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs-)

  • 이세영;최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.

Numerical study of the seismic behavior of steel frame-tube structures with bolted web-connected replaceable shear links

  • Lian, Ming;Cheng, Qianqian;Zhang, Hao;Su, Mingzhou
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.305-325
    • /
    • 2020
  • Beams of steel frame-tube structures (SFTSs) typically have span-to-depth ratios of less than five. This makes a flexural beam unsuitable for such an application because the plastic hinges at the beam-ends cannot be adequately developed. This leads to lower ductility and energy dissipation capacities of SFTSs. To address this, SFTSs with bolted web-connected replaceable shear links (SFTS-BWSLs) are proposed. In this structural system, a web-connected replaceable shear link with a back-to-back double channel section is placed at the mid-length of the deep beam to act as a ductile fuse. This allows energy from earthquakes to be dissipated through link shear deformation. SFTS and SFTS-BWSL buildings were examined in this study. Several sub-structures were selected from each designed building and finite element models were established to study their respective hysteretic performance. The seismic behavior of each designed building was observed through static and dynamic analyses. The results indicate that the SFTS-BWSL and SFTS have similar initial lateral stiffness and shear leg properties. The SFTS-BWSL had lower strength, but higher ductility and energy dissipation capacities. Compared to the SFTS, the SFTS-BWSL had lower interstory drift, base shear force, and story shear force during earthquakes. This design approach could concentrate plasticity on the shear link while maintaining the residual interstory drift at less than 0.5%. The SFTS-BWSL is a reliable resistant system that can be repaired by replacing shear links damaged due to earthquakes.

자연하천에 대한 Muskingum-Cunge 모형의 매개변수 산정 (Estimation of Muskingum-Cunge Parameters for Natural Streams)

  • 김진수;전경수
    • 한국수자원학회논문집
    • /
    • 제43권2호
    • /
    • pp.233-243
    • /
    • 2010
  • 하도의 횡단 및 종단 지형자료와 조도계수를 이용하여 자연하천에 대한 Muskingum-Cunge 모형의 매개변수들을 추정하는 방법을 제안하였다. 우선 각 단면에서의 다양한 수위에 대하여 통수단면 및 동수반경을 계산한 후, Manning 공식을 이용하여 유량을 산정한다. 이러한 과정은 하도에서의 모든 단면에 대하여 반복되며, 최종적으로 통수단면과 유량을 통한 회귀 분석에 의하여 매개변수들을 추정한다. 이와 같은 Muskingum-Cunge 모형의 매개변수 추정과정을 남한강 구간에 적용하였다. 추정된 매개변수들을 사용한 Muskingum-Cunge 모형의 계산결과는 무차원 RMS 오차, 첨두유량의 크기 및 발생시각 등 모든 면에서 HEC-1의 Muskingum-Cunge 모형에 비하여 동역학적 모형의 계산결과와 잘 일치하는 것으로 나타났다.

GIS와 수리학적 해석을 고려한 금만연결수로의 3차원 모델링에 관한 연구 (A Study on 3 Dimensional Modeling of Keum-man Connection Canal using GIS and considering Hydraulic Analysis)

  • 김대식;남상운;김태철
    • 한국농공학회논문집
    • /
    • 제50권5호
    • /
    • pp.3-15
    • /
    • 2008
  • This study aims to simulate the 3 dimensional (3D) model of Keum-man connection canal using geographic information system (GIS) as well as considering design in viewpoint of engineering. The canal connects from Keumkang to Mangyungkang in order to supply fresh water into Saemankeum lake. This study used 3 dimensional spatial planning model (3DSPLAM) process to generate the 3D model, which has not only several planning layers in actual process, but also their corresponding layers in modeling process to simulate 3D space of rural villages. The discharge of the canal is $20m^3/s$ on slope of 1/28,400 in the canal length of 14.2km, which consists of pipe line and open channel. This study surveyed the route of the canal and its surrounding environment for facilities to make images in the 3D graphic model. Besides, the present study developed data set in GIS for geogrphical surface modeling as well as parameters in hydraulic analysis for water surface profile on the canal using HEC-RAS model. From the data set constructed, this study performed analysis of water surface profile with HEC-RAS, generation of digital elevation model (DEM) and 3D objects, design of the canal section and route on DEM in AutoCAD, and 3D canal model and its surrounding 3D space in 3DMAX with virtual reality. The study result showed that the process making 3D canal model tried in this study is very useful to generate computer graphic model with the designed canal on the surface of DEM. The generated 3D canal can be used to assist decision support for the canal policy.

RADIOLOGICAL DOSE ASSESSMENT ACCORDING TO METHODOLOGIES FOR THE EVALUATION OF ACCIDENTAL SOURCE TERMS

  • Jeong, Hae Sun;Jeong, Hyo Joon;Kim, Eun Han;Han, Moon Hee;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.176-181
    • /
    • 2014
  • The object of this paper is to evaluate the fission product inventories and radiological doses in a non-LOCA event, based on the U.S. NRC's regulatory methodologies recommended by the TID-14844 and the RG 1.195. For choosing a non-LOCA event, one fuel assembly was assumed to be melted by a channel blockage accident. The Hanul nuclear power reactor unit 6 and the CE $16{\times}16$ fuel assembly were selected as the computational models. The burnup cross section library for depletion calculations was produced using the TRITON module in the SCALE6.1 computer code system. Based on the recently licensed values for fuel enrichment and burnup, the source term calculation was performed using the ORIGEN-ARP module. The fission product inventories released into the environment were obtained with the assumptions of the TID-14844 and the RG 1.195. With two kinds of source terms, the radiological doses of public in normal environment reflecting realistic circumstances were evaluated by applying the average condition of meteorology, inhalation rate, and shielding factor. The statistical analysis was first carried out using consecutive three year-meteorological data measured at the Hanul site. The annual-averaged atmospheric dispersion factors were evaluated at the shortest representative distance of 1,000 m, where the residents are actually able to live from the reactor core, according to the methodology recommended by the RG 1.111. The Korean characteristic-inhalation rate and shielding factor of a building were considered for a series of dose calculations.

The behaviour of a new type of connection system for light-weight steel structures applied to roof trusses

  • Kaitila, Olli;Kesti, Jyrki;Makelainen, Pentti
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.17-32
    • /
    • 2001
  • The Rosette-joining system is a completely new press-joining method for cold-formed steel structures. One Rosette-joint has a shear capacity equal to that of approximately four screws or rivets. The Rosette thin-walled steel truss system presents a new fully integrated prefabricated alternative to light-weight roof truss structures. The trusses are built up on special industrial production lines from modified top hat sections used as top and bottom chords and channel sections used as webs which are joined together with the Rosette press-joining technique to form a completed structure easy to transport and install. A single web section is used when sufficient but can be strengthened by double-nesting two separate sections or by using two lateral profiles where greater compressive axial forces are met. An individual joint in the truss can be strengthened by introducing a hollow bolt into the joint hole. The bolt gives the connection capacity a boost of approximately 20%. A series of laboratory tests have been carried out in order to verify the Rosette truss system in practice. In addition to compression tests on individual sections of different lengths, tests have also been done on small structural assemblies and on actual full-scale trusses of a span of 10 metres. Design calculations have been performed on selected roof truss geometries based on the test results, FE-analysis and on the Eurocode 3 and U.S.(AISI) design codes.