• Title/Summary/Keyword: Channel Form Discharge

Search Result 15, Processing Time 0.031 seconds

Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers (국내 하천 강턱유량시의 홍수빈도 추정)

  • Son, Min-Woo;Lee, Du-Han;Kim, Chang-Wan;Kim, Myoung-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1571-1575
    • /
    • 2006
  • Channel form discharge which determines shape and character of a channel is named as dominant discharge. Assuming that fixed discharge flows in the fluvial plain for a long time, it is channel form discharge of a certain channel if it changes the fluvial plain into shape of the channel. Channel form discharge can be demonstrated by concept of bankfull or effective discharge. 1.01, 1.58, 2, 2.33 and 5 year flood discharge were used in order to determine channel form discharge. Each frequency discharge was determined by 80 year flood discharge by a research result conducted by Kim and Won. 1.01 year frequency discharge was selected as the most similar discharge to bankfull discharge. 1.58 year frequency discharge habitually used in Korea exceeded bankfull discharge.

  • PDF

Assessment of Flood Frequency of Bankfull Discharge in Korea Rivers (국내 하천 강턱유량시의 홍수빈도 추정)

  • Son, Min-Woo;Lee, Du-Han;Kim, Chang-Wan;Kim, Myoung-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1107-1111
    • /
    • 2006
  • Channel form discharge which determines shape and character of a channel is named as dominant discharge. Assuming that fixed discharge flows in the fluvial plain for a long time, it is channel form discharge of a certain channel if it changes the fluvial plain into shape of the channel. Channel form discharge can be demonstrated by concept of bankfull or effective discharge. 1.01, 1.58, 2, 2.33 and 5 year flood discharge were used in order to determine channel form discharge. Each frequency discharge was determined by 80 year flood discharge by a research result conducted by Kim and Won. 1.01 year frequency discharge was selected as the most similar discharge to bankfull discharge. 1.58 year frequency discharge habitually used in Korea exceeded bankfull discharge.

  • PDF

A Method of Rating Curve Adjustment (수위유량곡선보정방법에 대하여)

  • 박정근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.2
    • /
    • pp.4116-4120
    • /
    • 1976
  • With the use of many rivers increased nearly to the capacity, the need for information concerning daily quantities of water and the total annual or seasonal runoff has became increased. A systematic record of the flow of a river is commonly made in terms of the mean daily discharge Since. a single observation of stage is converted into discharge by means of rating curve, it is essential that the stage discharge relations shall be accurately established. All rating curves have the looping effect due chiefly to channel storage and variation in surface slope. Loop rating curves are most characteristic on streams with somewhat flatter gradients and more constricted channels. The great majority of gauge readings are taken by unskilled observers once a day without any indication of whether the stage is rising or falling. Therefore, normal rating curves shall show one discharge for one gauge height, regardless of falling or rising stage. The above reasons call for the correction of the discharge measurements taken on either side of flood waves to the theoretical steady-state condition. The correction of the discharge measurement is to consider channel storage and variation in surface slope. (1) Channel storage As the surface elevation of a river rises, water is temporarily stored in the river channel. There fore, the actual discharge at the control section can be attained by substracting the rate of change of storage from the measured discharge. (2) Variation in surface slope From the Manning equation, the steady state discharge Q in a channel of given roughness and cross-section, is given as {{{{Q PROPTO SQRT { 1} }}}} When the slope is not equal, the actual discharge will be {{{{ { Q}_{r CDOT f } PROPTO SQRT { 1 +- TRIANGLE I} CDOT TRIANGLE I }}}} may be expressed in the form of {{{{ TRIANGLE I= { dh/dt} over {c } }}}} and the celerity is approximately equal to 1.3 times the mean watrr velocity. Therefore, The steady-state discharge can be estimated from the following equation. {{{{Q= { { Q}_{r CDOT f } } over { SQRT { (1 +- { A CDOT dh/dt} over {1.3 { Q}_{r CDOT f }I } )} } }}}} If a sufficient number of observations are available, an alternative procedure can be applied. A rating curve may be drawn as a median line through the uncorrected values. The values of {{{{ { 1} over {cI } }}}} can be yielded from the measured quantities of Qr$.$f and dh/dt by use of Eq. (7) and (8). From the 1/cI v. stage relationship, new vlues of 1/cI are obtained and inserted in Eq. (7) and (8) to yield the steady-state discharge Q. The new values of Q are then plotted against stage as the corrected steadystate curve.

  • PDF

Fabrication of Atmospheric Coplanar Dielectric Barrier Discharge and Analysis of its Driving Characteristics (평면형 대기압 유전장벽방전장치의 제작 및 동작특성분석)

  • Lee, Ki-Yung;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.80-84
    • /
    • 2014
  • The discharge characteristics of Surface Dielectric Barrier Discharge (SDBD) reactor are investigated to find optimal driving condition with adjusting various parameter. When the high voltage with sine wave form is applied to SDBD source, successive pulsed current waveforms are observed owing to multiple ignitions through the long discharge channel and wall charge accumulation on the dielectric surface. The discharge voltage, total charge between dielectrics, mean energy and power are calculated from measured current and voltage according to electrode gap and dielectric thickness. Discharge mode transition from filamentary to diffusive glow is observed for narrow gap and high applied voltage case. However, when the diffusive discharge is occurred with high applied voltage, the actual firing voltage is always lower than that with low driving voltage. The $Si_3N_4$, $MgF_2$, $Al_2O_3$ and $TiO_2$ are considered for dielectric protection and high secondary electron emission coefficient. SDBD with $MgF_2$ shows the lowest breakdown voltage. $MgF_2$ thin film is proposed as a protection layer for low voltage atmospheric dielectric barrier discharge devices.

Removal Efficiency of Heavy Metals in Acidic Mine Drainage from Microbial Mats (바이오매트 형성에 의한 산성광산배수 내 중금속 유출질량 제거효율)

  • Yu, Hun-Sun;Kwon, Byung-Hyuk;Kim, Park-Sa;So, Yoon-Hwan;Kang, Dong-Hwan
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.667-676
    • /
    • 2012
  • This research investigated to reduce mass of heavy metals in AMD(acid mine drainage) by microbial mats formed on the channel bed. As, Cd, Cu, Fe, Mn and Zn components were monitored in water and microbial mats, at three points (AMD1, AMD2 and AMD3), in a total of six times. Average daily discharge mass of heavy metals was highest in July, Fe component contained more than 76% of total discharge mass. Discharge mass of heavy metals of AMD and heavy metal contents in microbial mats decreased with downstream at channel. Heavy metal components that average daily discharge mass is over 0.5 kg were Fe, Cu and Zn, and they were highest in July. Average removal efficiency of heavy metals in AMD was highest about 21% in Fe, this microbial mats were due to form from precipitation of Fe component in AMD by aerobic iron bacteria. Relative content for As component in microbial mats than AMD was over 16 times, this As components were due to absorb at iron oxide and iron hydroxide on the surface of microbial mats.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

Time-series Changes in Particle Size Characteristics of Suspended Sediment at the Seungchon and the Juksan Weir in the Yeongsan River (영산강 부유하중의 시계열적 입도 특성 변화: 승촌보, 죽산보를 중심으로)

  • Lim, Young Shin;Kim, Jin Kwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.26 no.4
    • /
    • pp.1-20
    • /
    • 2019
  • In order to establish appropriate policy to control sediment-associated problems, it is necessary to identify the physical characteristics of the reservoir sediments in particulate form in the Yeongsan River. Two time-integrated suspended sediment samplers were installed at Seungchon and Juksan weir on the upper and middle Yeongsan River in July 2012. Reservoir sediment samples were obtained at monthly intervals until October 2014. During the monitoring period, a total of 38 sediment samples were obtained and analyzed. Seasonal trends of suspended sedimentation rates and grain size distributions were examined based on variations in precipitation and discharge fluctuations. Moreover, stream flow characteristics, which has a great influence on the physical characteristics of the river sediment, was analyzed using flow duration curve for the period 2003-2019 at Naju gauging station. Sedimentation rates during summer, when heavy rainfall was concentrated due to the monsoonal front and typhoon, were very high, indicating the positive relationship between sediment concentration and discharge. Particle size analysis of the collected sediment showed that coarse silt and very fine sand-sized sediment dominated most of the Seungchon weir sediment. On the other hand, medium silt-sized sediment dominated the downstream Juksan weir except for a few summer samples. These results implied that the physical characteristics of the suspended sediment are determined not only due to flow fluctuations, but also with regard to the antecedent rainfall conditions, hillslope-channel connectivity, and the supply of materials from various contributing regions. This information about flow characteristics and temporal variations in reservoir sediment can be used for safe management of the weir and discussing the issues on the dismantling of the weirs.

Analysis on Channel Morphology and Rock Resistance by Difference of Bedrock Types between Upper and Lower Reach (상.하류의 기반암 차이에 따른 하천의 형태와 암석의 저항력 분석)

  • Lee, Gwang-Ryul
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.1 s.118
    • /
    • pp.27-40
    • /
    • 2007
  • The streams evolve to diverse forms influenced by various factors such as rock resistance tectonic process, sediments and discharge. This study focuses on erosion resistance of rocks among these factors. The morphology of plane and longitudinal profile has been analysed in upper and lower reach of 6 streams using GIS; Yeoryong-cheon, Heungjeong-cheon, Duhak-cheon, Daehwa-cheon, Namcheon-cheon, Guryong-cheon, having distinct bedrock types between upper and lower reach. While the basins of granite have gentle slope, low concavity and wide valley area, those of gneiss form steep slope, high concavity and narrow valley area. However, the basins of sedimentary rock make steep slope and high relief in main channel, the other features show some differences in each stream. Among the various morphological features, the indices on slope and concavity of main channel, drainage density, ratio of valley area, average slope and average relief of the basin which have clear differences between rocks in upper and lower reach are calculated to interpret the erosion resistance of rocks in upper and lower reach. As a result, the upper reaches composed of gneiss have the highest erosion resistance, sedimentary rocks in upper and lower reaches show moderate resistance, and granite reaches generally have the lowest resistance except the upper reaches bordered by sedimentary rock.

Backwater Computation in River Channel by the Runoff-Frequency (유출변화(流出変化)에 의한 배수현상(背水現象) 해석(解析))

  • Suh, Seung Duk;Suk, Ki Hong
    • Current Research on Agriculture and Life Sciences
    • /
    • v.2
    • /
    • pp.77-90
    • /
    • 1984
  • Results investigated backwater phenomena at Geumho river basin to get a basic data for Daegu basin area development plan are as the follows. 1. It is a A=0.35 L 1.848 (r = 0.97), the relationship between basin area and river length at Geumho river. 2. Dividing the rainfall of Geumho river basin as two parts, a first half rainfall and a second half rainfall, the amount of a first half rainfall appeared 57.5% comparison with total rainfall. 3. The maximum flood discharge appeared 12 hrs. continuous rainfall rather than 24 hrs. continuous rainfall. 4. Results investigated backwater phenomena from Geumho II bridge to chungchun appeared the rising water level of 69 cm, 55 cm, 44 cm, at section III in the starting point water level of 1.8 m, 2.4 m, 4.0 m respectively. 5. Results investigated backwater phenomena by the flood water level appeared a similar form. There was a average rising water level of 30 cm at section III. At the results of this computation, it was confirmed that section III was affected the highest backwater phenomena among the observed river reaches in Geumho river. In addition, this paper should be given a assistance to decide a economic and safe section in construction of bank of river and estuary barrage.

  • PDF

Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position (필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석)

  • Park, Jee Min;Moon, Joo Hyun;Lee, Hyung Ju;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.69-76
    • /
    • 2018
  • The present study analyzed the effect of film hole position of 45 degree ribbed cooling channel on film cooling performance of gas turbine blades. We also investigated the influence of the ribs under the fixed blowing ratio. Three-dimensional numerical model was constructed and extensive simulation was conducted using the commercial code (Fluent ver. 17.0) under steady-state condition. Base on the simulation results, We investigated the cooling effectiveness, flow velocity, streamline, and pressure coefficient. Moreover, We analyzed the effect of cooling hole position on ejection of the secondary flow caused by the rib structure. From the results, It was found that internal flow of the cooling channel forms a vortex pair in the counterclockwise from the top side, and clockwise from the bottom side. For the channels with ribs, the vortex flow generated by the ribs caused a higher pressure difference near the hole outlet, resulting in at least 12% higher cooling effectiveness than the channel without ribs. Additionally, when the hole is located on the left side of the ribbed channel (Rib-Left), it can be found that the secondary flow generated by the ribs hits against wall surface near the hole to form a flow in the direction of the hole inclination angle. Therefore, It is considered that the region where the cooling gas discharged to the blade surface stays in the main flow boundary layer is wider than the other cases. In this case, The largest pressure coefficient difference was observed near the outlet of the hole, and as a result, the discharge of the cooling gas was accelerated and the cooling efficiency was slightly increased.