• 제목/요약/키워드: Channel Diffuser

검색결과 51건 처리시간 0.024초

연료전지 채널 내 균일한 유량분배를 위한 연료전지 스택의 매니폴드 디자인 최적화 연구 (Optimizing the Manifold Design of a Fuel Cell Stack for Uniform Distribution of Reactant Gases within Fuel Cell Channels)

  • 조아래;강경문;오성진;주현철
    • 한국유체기계학회 논문집
    • /
    • 제15권5호
    • /
    • pp.11-19
    • /
    • 2012
  • The main function of fuel cell manifold is to render reactants distribution as uniform as possible into a fuel cell stack. The purpose of this study is to numerically investigate the effects of stack manifold design on reactants distribution within a fuel cell stack. Four manifold designs with different manifold entrance shapes (expansion or diffuser) and different values of the extra width between the cell outer channel and manifold side wall are considered and applied to the fuel cell stack consisting of 50 cells. Since the fuel cell stack geometry involves several millions of grid points for numerical calculations, a parallel computing methodology is employed to substantially reduce the computational time and overcome the memory requirement. The numerical simulations are carried out and calculated results clearly demonstrate that both the manifold entrance shape and extra width have a substantial influence on manifold performance, controlling the degree of flow separation and entrance length for fully developed flow in the manifold channel. Finally, we suggest the optimum design of fuel cell manifold based on the simulation results.

Study on Performance Improvement of an Axial Flow Hydraulic Turbine with a Collection Device

  • Nishi, Yasuyuki;Inagaki, Terumi;Li, Yanrong;Hirama, Sou;Kikuchi, Norio
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.47-55
    • /
    • 2016
  • The portable hydraulic turbine we previously developed for open channels comprises an axial flow runner with an appended collection device and a diffuser section. The output power of this hydraulic turbine was improved by catching and accelerating an open-channel water flow using the kinetic energy of the water. This study aimed to further improve the performance of the hydraulic turbine. Using numerical analysis, we examined the performances and flow fields of a single runner and a composite body consisting of the runner and collection device by varying the airfoil and number of blades. Consequently, the maximum values of input power coefficient of the Runner D composite body with two blades (which adopts the MEL031 airfoil and alters the blade angle) are equivalent to those of the composite body with two blades (MEL021 airfoil). We found that the Runner D composite body has the highest turbine efficiency and thus the largest power coefficient. Furthermore, the performance of the Runner D composite body calculated from the numerical analysis was verified experimentally in an open-channel water flow test.

패션유통시장에서 시장 전문가의 쇼핑 행동과 멀티채널 이용현황 분석 (An Analysis of Market Maven's Shopping Behavior and Multi-Channel Usage in the Fashion Retailing Market)

  • 성희원;성정환
    • 패션비즈니스
    • /
    • 제20권2호
    • /
    • pp.134-148
    • /
    • 2016
  • In this study, we determined the characteristics and importance of market maven to today's fashion retailers. Market maven is defined as an individual who is highly involved in the marketplace and takes a role as an information diffuser. In order to identify market maven, a total of 415 data were collected from 30-40 consumers who purchased fashion items from the various types of retailers. The data were divided into three groups based on the average score of summated market maven's scale, and the high group was referred to as "market mavens." Results suggested that the market mavens existed in the fashion retailing market and presented the differences from the other two groups. The market maven group spent more and purchased more fashion items than the other groups. With respect to shopping behavior, the market maven group was more likely to browse and bargain hunt when shopping, and showed higher mean scores on impulse buying and overall satisfaction. In addition, market maven tended to purchase fashion items from different types of retailers including online channel. Accordingly, market mavens seemed to present common characteristics with heavy browser, recreational shopper, and/or multi-channel shopper. Market mavens showed shopping enjoyment characteristics when searching for market-related information from various retailers, hence this segment should be the essential target market in the multi-channel retailing environment.

다단 원심펌프 임펠러의 개량 수력설계 (Impeller Redesign of Multi-stage Centrifugal Pumps)

  • 오종식;김동수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.177-184
    • /
    • 2001
  • For two kinds of the multi-stage centrifugal pump with diffuser vanes and return channel vanes the meanline performance prediction is applied to get information of hydraulic performance at each internal flow station, because only flange-to-flange test curves are available. As a first step of redesign fur higher efficiency, the impeller geometry is numerically investigated in the present study. Quasi-3D inviscid loading distributions are obtained, for the two impellers, using the state-of-the-art method of impeller 3D design, which provides a guide to optimal redesign. Full 3D turbulent flow fields are thereafter analyzed, using the specialized CFD code, to confirm the redesign results. The inherent limitation of the traditional graphic method of impeller design, which most of domestic pump manufacturers are now employing, is found.

  • PDF

마이크로펌프를 이용한 PCR Chip의 구동 (Operation of PCR chip by micropump)

  • 최종필;반준호;장인배;김헌영;김병희
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.463-467
    • /
    • 2004
  • This paper presents the fabrication possibility of the micro actuator which uses a micro-thermal bubble, generated b micro-heater under pulse heating. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, he middle plate, the upper plate. The lower plate includes the channel and chamber are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The middle plate includes the chamber and diaphragm d the upper plate is the micro-heater. The Micropump is fabricated by bonding process of the three layer. This paper resented the possibility of the PCR chip operation by the fabricated micropump.

  • PDF

열공압 방식의 polydimethylsiloxane 마이크로 펌프의 제작 및 특성 (Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Micropump)

  • 김진호;문민철;김주호;김영호;김한수;한경희;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.342-346
    • /
    • 2004
  • A thermopneumatic-actuated polydimethylsiloxane (PDMS) micropump has been fabricated and their properties are characterized. The diffusers are used as a flow-rectifying element instead of passive check valves. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using PDMS and indium tin oxide (ITO) glass. We presented the PDMS micropump that is easily integrated with the in-channel PDMS microvalves on the same substrate. The flowrate of the micropump increases linearly as the applied pulse voltage to the ITO heater increases. The fabricated ITO heater resistance is 6.54k$\Omega$. The peak of the flow rate is observed at the duty ratio of 10% for the applied pulse voltage of 55V at 6Hz and the maximum flow rate of 78nl/min is measured.

EMP 방호시설의 덕트 및 배관 최적 설계 방안 (Design Optimization for Air Ducts and Fluid Pipes at Electromagnetic Pulse(EMP) Shield in Highly Secured Facilities)

  • 방승기;김재훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.15-24
    • /
    • 2014
  • This study conducted a computational fluid dynamics(CFD) analysis to find an appropriate diameter or sectional area of air ducts and fluid pipes which have an electromagnetic pulse(EMP) shied to protect indoor electronic devices in special buildings like military fortifications. The result shows that the optimized outdoor air intake size can be defined with either the ratio of the maximum air velocity in the supply duct to the air intake size, or the shape ratio of indoor supply diffuser to the outdoor air intake. In the case of water channel, the fluid velocity at EMP shield with the identical size of the pipe, decreases by 25% in average due to the resistance of the shield. The enlargement of diameter at the shield, 2 step, improves the fluid flow. It illustrated that the diameter of downstream pipe size is 1step larger than the upstream for providing the design flow rate. The shield increases friction and resistance, in the case of oil pipe, so the average flow velocity at the middle of the shield increase by 50% in average. In consideration of the fluid viscosity, the oil pipe should be enlarged 4 or 5 step from the typical design configuration. Therefore, the fluid channel size for air, water, and oil, should be reconsidered by the engineering approach when EMP shield is placed in the middle of channel.

Study on flow characteristics in LBE-cooled main coolant pump under positive rotating condition

  • Lu, Yonggang;Wang, Zhengwei;Zhu, Rongsheng;Wang, Xiuli;Long, Yun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2720-2727
    • /
    • 2022
  • The Generation IV Lead-cooled fast reactor (LFR) take the liquid lead or lead-bismuth eutectic alloy (LBE) as the coolant of the primary cooling circuit. Combined with the natural characteristics of lead alloy and the design features of LFR, the system is the simplest and the number of equipment is the least, which reflects the inherent safety characteristics of LFR. The nuclear main coolant pump (MCP) is the only power component and the only rotating component in the primary circuit of the reactor, so the various operating characteristics of the MCP are directly related to the safety of the nuclear reactor. In this paper, various working conditions that may occur in the normal rotation (positive rotating) of the MCP and the corresponding internal flow characteristics are analyzed and studied, including the normal pump condition, the positive-flow braking condition and the negative-flow braking condition. Since the corrosiveness of LBE is proportional to the fluid velocity, the distribution of flow velocity in the pump channel will be the focus of this study. It is found that under the normal pump condition and positive-flow braking conditions, the high velocity region of the impeller domain appears at the inlet and outlet of the blade. At the same radius, the pressure surface is lower than the back surface, and with the increase of flow rate, the flow separation phenomenon is obvious, and the turbulent kinetic energy distribution in impeller and diffuser domain shows obvious near-wall property. Under the negative-flow braking condition, there is obvious flow separation in the impeller channel.

여과수열원 히트펌프를 이용한 온실난방기술 개발 (Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;강연구;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

압력구배기법을 이용한 난류 유동장 해석 (Analysis of Turbulent flow using Pressure Gradient Method)

  • 유근종
    • 한국추진공학회지
    • /
    • 제3권2호
    • /
    • pp.1-9
    • /
    • 1999
  • 층류 유동을 기준으로 형성된 압력구배기법의 적용성을 난류유동에 대하여 검증하였다. 압력구배기법은 압력 자체보다는 연속방정식을 이용하여 구한 압력의 구배를 활용하므로서 유동장의 해석에 질량보존의 물리적 법칙을 용이하게 반영할 수 있는 특징이 있다. 압력구배기법은 모든 유동변수를 한 점에 위치시키고 압력구배는 그 사이에 위치시키는 준 엇갈림 좌표계를 기준으로 형성되었다. 이러한 격자계는 프로그램하기가 용이하며 유동의 물리적 특성을 올바로 반영할 수 있는 장점이 있다. 난류유동에 대한 검증은 저 레이놀즈수 $\kappa$-$\varepsilon$ 모델을 이용하여 완전히 발달한 채널유동, 후향계단유동, 원추형 디퓨저유동 등에 대하여 수행하였다. 이러한 해석결과로부터 압력구배기법은 난류유동의 해석에 적용이 가능한 것으로 판단된다. 그러나 압력구배기법은 계산시간이 다소 길게 요구되며 압력구배식의 적정 $\gamma$를 구하는 방법이 용이하지 않아 이에 대한 개선이 요구되고 있다.

  • PDF