• Title/Summary/Keyword: Channel Configuration

Search Result 382, Processing Time 0.021 seconds

The study on heat transfer enhancement using indirect cooling system in the channel with heat source (간접냉각방식을 이용한 열원이 부착된 채널내의 열전달 촉진에 관한 연구)

  • 김광추;박만흥;윤준규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.321-331
    • /
    • 1999
  • A numerical study is carried out for increasing heat removal using indirect cooling system. Computation is performed for nine cases as variation of flow condition in the lower channel. As the result of this study, water is more effective than air at the same pressure loss in spite of the lower inlet velocity. In channel configuration, the vertical channel is more effective than horizontal channel because of the buoyancy effect. Under the condition that heat generation is the same, counter flow effectively decreases the temperature difference among blocks. Parallel flow is more effective than counter flow when average temperature of all blocks is considered. In the case of installing obstacles in the lower channel, it is desirable to install obstacles in the bottom of lower channel. Heat transfer rate increases as the height of obstacles increases.

  • PDF

The Influences of Mobile Channel Configurations on Channel Integration Quality in Cross-Channel Electronic Commerce

  • Junghwan Kim;Miri Kim;Seonjin Shin;Jaeki Song
    • Asia pacific journal of information systems
    • /
    • v.27 no.1
    • /
    • pp.18-37
    • /
    • 2017
  • Many retailers have extended their extant online channels (i.e., websites) to mobile channels for communicating with and delivering their products or services to customers. However, retailers have trouble delivering a cohesive and seamless customer experience across the Web and mobile channels. To address this challenge, we propose a way for retailers to enrich customers' seamless experiences across channels by configuring mobile channels (functionality- and interactivity-oriented configurations) along with traditional Web channels. This study theoretically contributes a research framework that posits the role of mobile channels as an extension of existing websites. It also provides practical insight for effectively articulating an e-commerce strategy in cross-channel electronic commerce.

Role of $K^+$ Channels to Resting Membrane Potential of Rabbit Middle Cerebral Arterial Smooth Muscle Cells

  • Kim, Na-Ri;Han, Jin;Kim, Eui-Yong;Kim, Yun-Hee;Sim, Jae-Hong;Kim, Soo-Cheon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.6
    • /
    • pp.547-554
    • /
    • 1999
  • The aim of the present study is to investigate the contribution of $Ca^{2+} ?activated\;K^+\;(K_{Ca})$ channels and delayed rectifier $K^+\;(K_V)$ channels to the resting membrane potential (RMP) in rabbit middle cerebral arterial smooth muscle cells. The RMP and membrane currents were recorded using the whole-cell patch configuration and single $K_{Ca}$ channel was recorded using the outside-out patch configuration. Using the pipette solution containing 0.05 mM EGTA, the RMP was $-25.76{\pm}5.08$ mV (n=12) and showed spontaneous transient hyperpolarizations (STHPs). The membrane currents showed time- and voltage-dependent outward currents with spontaneous transient outward currents (STOCs). When we recorded the membrane potential using the pipette solution containing 10 mM EGTA, the RMP was depolarized and did not show STHPs. The membrane currents showed no STOCs but only showed slowly inactivating outward currents. External TEA (1 mM) reversibly inhibited the STHPs, depolarized the RMP, reduced the membrane currents, abolished STOCs, and decreased the open probability of single $K_{Ca}$ channel. When $K_V$ currents were isolated, the application of 4-AP (5 mM) depolarized the RMP. The important aspect of our results is that $K_{Ca}$ channel is responsible for the generation of the STHPs in the membrane potential and plays an important role in the regulation of the RMP and $K_V$ channel is also responsible for the regulation of the RMP in rabbit middle cerebral arterial smooth muscle cells.

  • PDF

Design and implementation of remote controlling wireless transmission unit using duplex-FSK (Duplex-FSK 원격제어 무선 전송부 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.629-635
    • /
    • 2009
  • The FSK duplex remote controlling wireless transmission units with a common local oscillator circuit for transmitter and receiver are designed and implemented in this paper. In the FSK full-duplex the channel frequency for Tx/Rx is allocated, a common switching oscillator circuit for Tx/Rx is designed in the FSK half-duplex scheme. Both of FSK units get functions of automatic channel detection for busy channels and channel configuration for an idle channel in order to reduce the RF channel interference and are designed as a remote controller with small-sized low power of 10mW and the 400MHz-colpitz type PLL configuration of 50kHz channel separation. The full-duplex Tx/Rx link frequency gets frequency difference of 42.8MHz, which is double of 21.4MHz IF frequency.

A new WDM/TDM protocol for very high speed optical networks (고속광통신망용 새로운 WDM/TDM 프로토콜)

  • 이상록;이성근;박진우
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.2
    • /
    • pp.50-58
    • /
    • 1996
  • This paper proposes the channel-access protocol suitable to a very high speed photonic WDM network with star configuration, which can provide a high channel utilization and insensitivity to the propagation delay. The proposed protocol employs a control channel and a simple status table to deal with the propagation delay which has been a major limiting factor in the performance of the very high speed optical communication networks. The control channel transmits control information in order to reserve access on data channels, and each node constitutes a status table after the reception of control pckets which holds information about the availbility of destination node and data channel. The proposed protocol is insensitive to the propagation delay time by removing necessity of the retransmission and by allowing parallel transmission of control packet and data packets. It is proved in analysis and discrete event simulation that the proposed protocol is superior in throughput and mean delay, especially at the high load conditions compared to the existing high speed channel-access protocols.

  • PDF

PRIMARY INSTABILITY OF THE CHANNEL FLOW WITH A STREAMWISE-PERIODIC ARRAY OF CIRCULAR CYLINDERS - EFFECTS OF THE DISTANCE BETWEEN THE CYLINDER AND THE CHANNEL WALL - (원형 실린더가 주기적으로 배열된 채널 유동의 주 유동 불안정성 - 실린더와 채널 벽 간격의 영향 -)

  • Yoon, D.H.;Yang, K.S.;Kang, C.
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.54-59
    • /
    • 2010
  • A parametric study has been carried out to elucidate the characteristics of channel flow with a streamwise-periodic array of cylinders. This flow configuration is relevant to heat exchanger applications. The presence of cylinders in channel flow causes the attached wall boundary layer to separate, leading to significant change in flow instabilities. There exist two kinds of instabilities; flow undergoes a primary instability (Hopf bifurcation) at a lower Reynolds number, and the unsteady two-dimensional flow becomes unstable to three-dimensional disturbances at a higher Reynolds number. We report here the dependencies of the primary instability as well as the flow characteristics of the subsequent unsteady flow, including flow-induced forces and Strouhal number of vortex shedding, on the distance between the cylinder and the channel wall.

Ultra Broadband Indoor Channel Measurements and Calibrated Ray Tracing Propagation Modeling at THz Frequencies

  • Priebe, Sebastian;Kannicht, Marius;Jacob, Martin;Kurner, Thomas
    • Journal of Communications and Networks
    • /
    • v.15 no.6
    • /
    • pp.547-558
    • /
    • 2013
  • Ultra broadband communication systems operated at THz frequencies will require the thorough knowledge of the propagation channel. Therefore, an extensive measurement campaign of 50 GHz wide indoor radio channels is presented for the frequencies between 275 and 325 GHz. Individual ray paths are resolved spatially according to angle of arrival and departure. A MIMO channel is recorded in a $2{\times}2$ configuration. An advanced frequency domain ray tracing approach is used to deterministically simulate the THz indoor propagation channel. The ray tracing results are validated with the measurement data. Moreover, the measurements are utilized for the calibration of the ray tracing algorithm. Resulting ray tracing accuracies are discussed.

Numerical Study for Configuration Design in the Exhaust Gas Cooling System (배출가스 냉각장치 형상설계를 위한 수치해석)

  • Lee, Suk Young
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.7-12
    • /
    • 2016
  • This paper deals with a parametric study on cooling channel configurations to enhance the cooling effect. As a cooling effect has been increased, the exhaust gas by the plant from a manufacture is becoming deceased. To solve this problem, the design of a efficient cooling system is needed. In this paper, the cooling channel was analyzed to improve the cooling performance. The heat transfer rates depending on the number of baffle and the heiht of fin were obtained by using numerical simulation method. Three-dimensional Reynolds-averaged Naiver-Stokes equations were used to estimate flow and heat transfer in cooling channel, and the $k-{\varepsilon}$ model for turbulence closure was employed.

Regenerative Cooling Channel Design of a Supersonic Combustor Considering High-Temperature Property of Fuel (연료 고온물성을 고려한 초음속 연소기 재생냉각 유로 설계)

  • Yang, Inyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.37-46
    • /
    • 2018
  • A design study on the cooling channel configuration in a regeneratively cooled supersonic combustor was performed. The flow parameters on the hot- and cold-side channels were calculated using a quasi-one-dimensional model. The heat transfer between these two sides was estimated as a part of the flow calculation. For the reference configuration, the total amount of heat exchanged was 10.7 kW, the heat flux was $566kW/m^2$, and the fuel temperature increase between the inlet and outlet was 153 K. Seven designs of the heat exchanger channel were compared for their heat transfer performance.