• Title/Summary/Keyword: Channel Calibration

Search Result 167, Processing Time 0.037 seconds

Design of Sample Chamber and Implementation of a 4-Channel Electrolyte Analyzer using ISFET Microsensor (ISFET 마이크로센서용 샘플챔버 설계 및 4채널 전해질 분석기의 구현)

  • Bae, Sang-Kon;Lee, Ho-Shin;Won, Chul-Ho;Chae, Seung-Pyo;Kim, Chang-Soo;Cho, Byung-Wook;Sohn, Byung-Ki;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.307-315
    • /
    • 1997
  • In this paper, a sample chamber which provide easy replacement of ISFET sensor and consume only small sample volume for electrolyte analysis is designed and a 4-channel electrolyte analyzer employing 2-point calibration method is implemented. In addition, we proposed sample loading detection circuit for minimizing sample and calibration solutions and implemented it. Developed electrolyte analyzer consists of control system part and flow system part. For the effective control of the developed hardware, system software is developed as three individual routines ; measuring routine, calibration routine and washing routine.

  • PDF

NAC Measurement Technique on High Parallelism Probe Card with Protection Resistors

  • Kim, Gyu-Yeol;Nah, Wansoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.641-649
    • /
    • 2016
  • In this paper, a novel time-domain measurement technique on a high parallelism probe card with protection resistors installed is proposed. The measured signal amplitude decreases when the measurement is performed by Needle Auto Calibration (NAC) probing on a high parallelism probe card with installed resistors. Therefore, the original signals must be carefully reconstructed, and the compensation coefficient, which is related to the number of channel branches and the value of protection resistors, must be introduced. The accuracy of the reconstructed signals is analyzed based on the varying number of channel branches and various protection resistances. The results demonstrate that the proposed technique is appropriate for evaluating the overall signal performance of probe cards with Automatic Test Equipment (ATE), which enhances the efficiency of probe card performance test dramatically.

Construction of HTS multi-channel SQUID system

  • Park, W.K.;Lee, H.J.;Moon, S.H.;Lim, S.H.;Kim, D.Y.;Oh, B.;Lee, S.M.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.169-172
    • /
    • 2000
  • We have constructed a multi-channel SQUID magnetometer system. The system is designed to operate normally with 10 high temperature direct coupled SQUIDs. The main features of the system include a remote control by serial communication, low noise with wide bandwidth and high slew rate by several MHz modulation, signal conditioning and calibration by digital signal processing.

  • PDF

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

Preliminary Analysis of Data Quality and Cloud Statistics from Ka-Band Cloud Radar (Ka-밴드 구름레이더 자료품질 및 구름통계 기초연구)

  • Ye, Bo-Young;Lee, GyuWon;Kwon, Soohyun;Lee, Ho-Woo;Ha, Jong-Chul;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2015
  • The Ka-band cloud radar (KCR) has been operated by the National Institute of Meteorological Research (NIMR) of Korea Meteorological Administration (KMA) at Boseong National Center for Intensive Observation of severe weather since 2013. Evaluation of data quality is an essential process to further analyze cloud information. In this study, we estimate the measurement error and the sampling uncertainty to evaluate data quality. By using vertically pointing data, the statistical uncertainty is obtained by calculating the standard deviation of each radar parameter. The statistical uncertainties decrease as functions of sampling number. The statistical uncertainties of horizontal and vertical reflectivities are identical (0.28 dB). On the other hand, the statistical uncertainties of Doppler velocity (spectrum width) are 2.2 times (1.6 times) larger at the vertical channel. The reflectivity calibration of KCR is also performed using X-band vertically pointing radar (VertiX) and 2-dimensional video disdrometer (2DVD). Since the monitoring of calibration values is useful to evaluate radar condition, the variation of calibration is monitored for five rain events. The average of calibration bias is 10.77 dBZ and standard deviation is 3.69 dB. Finally, the statistical characteristics of cloud properties have been investigated during two months in autumn using calibrated reflectivity. The percentage of clouds is about 26% and 16% on September to October. However, further analyses are required to derive general characteristics of autumn cloud in Korea.

A Study on RF Calibration Method of Next Generation Mobile Communication System (차세대 이동통신 시스템의 RF Calibration 기법에 관한연구)

  • Kim, Wan-Tae;Cho, Sung-Joon
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.859-864
    • /
    • 2010
  • In the next generation system, a study on realization of Multi-Core system is in progress for applying it in multi service network. Therefore some mobile systems are expected to be appeared. These systems can support WiBro, WCDMA, CDMA, etc with single terminal. These systems have to support various FA using broadband frequency and hand over to other service network. Especially, in the telecommunication system composed of cell, the transmit power can be interference at adjacent system, has effect on system channel capacity and cell size. In this paper, we improve the unstable transmit power caused by unsettled system operation, propose the RF(Radio Frequency) Calibration method which can use the transmit power stably even during hand over between heterogeneous networks causing unstable power change. Also we used proposed method and analysed used electricity of system during hand over between heterogeneous networks.

Experiment of KOMPSAT-3/3A Absolute Radiometric Calibration Coefficients Estimation Using FLARE Target (FLARE 타겟을 이용한 다목적위성3호/3A호의 절대복사 검보정 계수 산출)

  • Kyoungwook Jin;Dae-Soon Park
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1389-1399
    • /
    • 2023
  • KOMPSAT-3/3A (K3/K3A) absolute radiometric calibration study was conducted based on a Field Line of sight Automated Radiance Exposure (FLARE) system. FLARE is a system, which has been developed by Labsphere, Inc. adopted a SPecular Array Radiometric Calibration (SPARC) concept. The FLARE utilizes a specular mirror target resulting in a simplified radiometric calibration method by minimizing other sources of diffusive radiative energies. Several targeted measurements of K3/3A satellites over a FLARE site were acquired during a field campaign period (July 5-15, 2021). Due to bad weather situations, only two observations of K3 were identified as effective samples and they were employed for the study. Absolute radiometric calibration coefficients were computed using combined information from the FLARE and K3 satellite measurements. Comparison between the two FLARE measurements (taken on 7/7 and 7/13) showed very consistent results (less than 1% difference between them except the NIR channel). When additional data sets of K3/K3A taken on Aug 2021 were also analyzed and compared with gain coefficients from the metadata which are used by current K3/K3A, It showed a large discrepancy. It is assumed that more studies are needed to verify usefulness of the FLARE system for the K3/3A absolute radiometric calibration.

A Received Signal Strength-based Primary User Localization Scheme for Cognitive Radio Sensor Networks Using Underlay Model-based Spectrum Access

  • Lee, Young-Doo;Koo, Insoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.8
    • /
    • pp.2663-2674
    • /
    • 2014
  • For cognitive radio sensor networks (CRSNs) that use underlay-based spectrum access, the location of the primary user (PU) plays an important role in the power control of the secondary users (SUs), because the SUs must keep the minimum interference level required by the PU. Received signal strength (RSS)-based localization schemes provide low-cost implementation and low complexity, thus it is suitable for the PU localization in CRSNs. However, the RSS-based localization schemes have a high localization error because they use an inexact path loss exponent (PLE). Thus, applying a RSS-based localization scheme into the PU localization would cause a high interference to the PU. In order to reduce the localization error and improve the channel reuse rate, we propose a RSS-based PU localization scheme that uses distance calibration for CRSNs using underlay model-based spectrum access. Through the simulation results, it is shown that the proposed scheme can provide less localization error as well as more spectrum utilization than the RSS-based PU localization using the mean and the maximum likelihood calibration.

A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy (근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구)

  • Yoon, Sung-Un;Ma, Sang-Dong;Kim, Myung-Yun;Kim, Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

The timing do-skew modeling and design in a high speed digital system (고속 디지털 시스템에서 전달 시간차의 보정 모델링 및 구현)

  • Oh, Kwang-Suhk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.601-604
    • /
    • 2002
  • In this paper, the timing do-skew modeling for a high speed logic tester channels is developed. The time delay of each channel in a logic tester are different from other channels and it can produce timing error in a test. To get the best timing accuracy in the test with a logic tester, the timing skew must be compensated. The timing skew of channels is due to the difference of time delay of pin-electronics devices composing channels and length of metal line placed on PCB. The expected timing difference of channels can be calculated according to the specifications of pin electronics devices and strip line modeling of PCB. With the calculated delay time, the timing skew compensation circuit has been designed. With the timing skew compensation circuit, the timing calibration of a logic tester can be peformed easily and automatically without other time measuring instruments. The calibration method can then be directly applied to logic testers in mass production lines.

  • PDF