• Title/Summary/Keyword: Channel -flow

Search Result 2,827, Processing Time 0.028 seconds

The Hydraulic Assessment of Side Weir using 3D Computational Fluid Dynamics Program (3차원 수치모형에 의한 횡월류위어의 수리학적 평가)

  • Nam, Ki-Young;Han, Kun-Yeun;Park, Hong-Sung;Kim, Keuk-Soo;Choi, Seung-Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 2010
  • The objectives of this study are to analyze flow characteristics for a side weir, which is an inlet structure for flow discharge reduction in the main channel through 3 dimensional numerical analysis and to understand the efficiency of the overflow effect at the side weir. In this study over 40 simulations using FLOW-3D, a computational fluid dynamics program were conducted, and the results were analyzed to find the influence of the flow hydraulics, geometry, channel and weir shapes on the coefficient. It is especially considered the relatively high stage in downstream that may cause flow within channel to be backed up along the channel. Additionally by setting up the scale of simulations much larger than the existing test equipment designed by other researchers, it is intended to analyze more accurate hydraulic behavior along with the realistic hydraulic features such as structures and volumes of flow. The results show that for design with subcritical flow only if the Froude number of upstream is sustained below 0.5 and the length of weir is 33-100% of the width of channel, it is expected to improve the efficiency of the overflow over a side weir.

NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN A COOLING CHANNEL WITH STAGGERED V-SHAPED RIBS (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, H.K.;Kim, K.Y.
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.107-113
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a square cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration (h/$D_h$)of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the channel due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth pipe with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 18 times higher streamwise pressure drop than the latter ones. However, for the thermal performances, based on the equal pumping power condition, the case of p/h=2.8 gives the best result among three cases, mainly due to relatively low streamwise pressure drop, although it gives relatively low heat transfer augmentation.

NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN COOLING CHANNEL WITH A STAGGERED V-SHAPED RIB (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, H.K.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration ($h/D_h$) of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth channel with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 2.5 times higher streamwise pressure drop than the latter ones. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered ones give about 2 times higher values than the latter ones with more uniform heat transfer distribution.

  • PDF

Analysis of the turbulent flow on the periodically arranged semi-circular ribs in a rectangular channel (사각채널 내 주기적으로 배열된 반원 리브 영향의 유동해석)

  • Lee, G.H.;Nine, Md.J.;Choi, S.H.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • The flow characteristics on the periodically arranged semi-circular ribs in a rectangular channel for turbulent flow have been investigated numerically. The aspect ratio of the rectangular channel was AR=5, the rib height to hydraulic diameter ratio was 0.07 and rib height to channel height ratio was e/H=0.117. The v2-f turbulence model and SST k-${\omega}$ turbulence model were used to find the flow characteristics of near the wall which are suited for realistic phenomena. The numerical analysis results show turbulent flow characteristics and pressure drop at the near the wall as observed experimentally. The results predict that turbulent kinetic energy(k) is closely relative to the diffusion of recirculation flow, and v2-f turbulence model simulation results have a good agreement with experimental.

Three-Dimensional Numerical Study on the Vortex Flow in a Horizontal Channels with High Viscous Fluid(2) (수평채널 내 고 점성유체의 볼텍스 유동에 관한 3차원 수치해석(2))

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.36-42
    • /
    • 2015
  • TMixed convective flow in a bottom heated and top cooled rectangular channel can be significantly affected by the channel aspect ratio, Prandtl number, Reynolds number, Rayleigh number and angle of inclination. In such a mixed convection, the flow pattern plays an important role in various technological processes. In this study, a numerical investigation is carried out to explore mixed convection in a three-dimensional rectangular channel with bottom heated and top cooled uniformly. The three-dimensional governing equations are discretized using the finite volume method. In the range of low Reynolds number($0{\leq}Re{\leq}9.6{\times}10^{-2}$), the effects of the aspect ratio($2{\leq}AR{\leq}12$) and Gr/Re are presented and discussed. The longitudinal roll number in the channel is increased with increasing aspect ratio, and the roll number induced, regardless of the aspect ratio number, is even in the range of aspect ratios between 2 and 12, New vortex flow structure containing inclined longitudinal rolls is found, which is affected by aspect ratio and Reynolds number. The ratio Gr/Re is used to check the relative magnitudes of forced and natural convection in the mixed convective flow of high viscous fluid.

Reflood Experiments with Horizontal and Vertical Flow Channels

  • Chung, Moon-Ki;Lee, Seung-Hyuck;Park, Choon-Kyung;Lee, Young-Whan
    • Nuclear Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.153-162
    • /
    • 1980
  • The investigation of the fuel cladding temperature behavior and heat transfer mechanism during the reflooding phase of a LOCA plays an important role in performance evaluation of ECCS and safety analysis of water reactors. Reflooding experiments were performed with horizontal and vertical flow channels to investigate the effect of coolant flow channel orientation on rewetting process. Emphasis was mainly placed on the CANDU reactor which has horizontal pressure tubes in core, and the results were compared with those of vertical channel. Also to investigate the rewetting process visually, the experiments by using a rod in annulus and a quartz tube heated outside were performed. It can be concluded that the rewetting velocity in horizontal flow channel is clearly affected by flow stratification, however, the average rewetting velocity is similar to those in vertical flow channel for same conditions.

  • PDF

Microflow of dilute colloidal suspension in narrow channel of microfluidic-chip under Newtonian fluid slip condition

  • Chun Myung-Suk;Lee Tae Seok;Lee Kangtaek
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.207-215
    • /
    • 2005
  • We present a finite difference solution for electrokinetic flow in rectangular microchannels encompassing Navier's fluid slip phenomena. The externally applied body force originated from between the nonlinear Poisson-Boltzmann field around the channel wall and the flow-induced electric field is employed in the equation of motion. The basic principle of net current conservation is applied in the ion transport. The effects of the slip length and the long-range repulsion upon the velocity profile are examined in conjunction with the friction factor. It is evident that the fluid slip counteracts the effect by the electric double layer and induces a larger flow rate. Particle streak imaging by fluorescent microscope and the data processing method developed ourselves are applied to straight channel designed to allow for flow visualization of dilute latex colloids underlying the condition of simple fluid. The reliability of the velocity profile determined by the flow imaging is justified by comparing with the finite difference solution. We recognized the behavior of fluid slip in velocity profiles at the hydrophobic surface of polydimethylsiloxane wall, from which the slip length was evaluated for different conditions.

Numerical Analysis-Based Design of PEMFC Channel, Fabrication of Channels, and Performance Test Using SU-8 (수치해석을 통한 PEMFC 채널의 설계와 SU-8을 이용한 채널 제작 및 성능 평가)

  • Choi, In-Jea;Wang, Hak-Min;Choi, Kap-Seung;Kim, Hyung-Man
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.349-354
    • /
    • 2010
  • Fuel cells have attracted enormous interest as new power sources because the cells can be used to solve the problem of environmental pollution as well as the natural-resource exhaustion problem. In this study, hydrogen-gas flow in microchannels of different shapes was numerically analyzed to improve the efficiency of a microfuel cell. Flow characteristics in six microchannels of different shapes but under identical boundary conditions were simulated. The analysis result shows that the flow characteristics such as velocity, uniformity, and flow rate, greatly depend upon the channel shape. This implies that the efficiency of microfuel cell can be expected to be increased by adopting the optimal configuration of channel shape for hydrogen-gas flow. The experimental results show that power density of a PEMFC with a microflow channel is higher than that of a PEMFC without a microflow channel; however, a durable catalyst is required in MEA.

A Case Study of the Habitat Changes due to the Restoration of Low-Flow Channel (저수로 물길 복원을 통한 서식처 공간 변화 연구)

  • Choi, Jonggeun;Choi, Heung Sik;Choi, Byungwoong
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.1
    • /
    • pp.58-68
    • /
    • 2019
  • This present study conducted the impact of the restoration of low-flow channel on fish habitat in a reach of the Wonju Stream, Korea. The target species were Zacco koreanus, a dominant species in the middle- and upper-stream of Wonju Stream. The River2D model was used for the computation of the flow and the habitat suitability index model was used to estimate the quantity and quality of fish habitat using habitat suitability curves. In order to restore the study area, the low-flow channel was identified through the bankfull discharge of the study reach, and the best hydraulic section was designed. In addition, various restoration techniques were applied to the low-flow channel through rocks, pool/riffle structures, and the change of the channel width. Simulation results indicated that the restoration of the best hydraulic section effects decreased habitat suitability for the target species. However, when various restoration techniques were applied, the WUA (Weighted Usable Area) was improved by about 11%.

An Experimental Study on the Effect of a Hydraulic Structure on the Three-dimensional Flow in a Meandering Channel (만곡수로 내 수리구조물 설치에 따른 3차원 흐름 특성변화 실험 연구)

  • Lee, Dong Hun;Kim, Su Jin;Kang, Seokkoo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.635-645
    • /
    • 2015
  • The objective of this study is to examine the three-dimensional turbulent flows occurring in the meandering channel with presence of a groyne. A series of laboratory experiments are carried out in a meandering channel with trapezoidal cross sections. The channel is a 24.4 m long, 1.5 m wide, and the bottom slope in the longitudinal direction is 0.02. Two cases with and without the groyne are considered in the experiment. Three-dimensional velocity fields are measured using an acoustic Doppler velocimetry (ADV) at approximately sixty locations in each cross section. The measured velocity fields are averaged in time, and the time-averaged flow revealed that the mean velocity magnitude along the outer bank of the channel was reduced significantly and the direction of the primary flow was directed toward the center of the channel due to the presence of the groyne.