• 제목/요약/키워드: Chamber Structure

검색결과 570건 처리시간 0.028초

진공용 3자유도 얼라인먼트 스테이지 개발 (Development of Three D.O.F Alignment Stage for Vacuum Environment)

  • 한상진;박종호;박희재
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.138-147
    • /
    • 2001
  • Alignment systems are frequently used under various semiconductor manufacturing environment. Particularly in PDP(Plasma Display Panel) manufacturing process, the alignment system is applied to the combining and sealing processes of the upper and lower glass panels of PDP, where these processes are performed in the vacuum chamber of high vacuum and high temperature. In this paper, the XYΘ-alignment stage is developed to align PDP panels. Because of high vacuum and high temperature environment, the alignment chamber has been designed to isolate the inner part of the alignment chamber from the outer environment of high vacuum and high temperature, in which every part of the alignment stage is inserted. As it is difficult to attach feedback sensors to the alignment stage in the alignment chamber, the alignment stage is implemented with the open loop algorithm, where the parallel link structure has been designed using step-motors and ball-screws for structural simplicity. The kinematic analysis is performed to drive the parallel link structure, based on the experiments of actuation-compensation of the alignment stage. For the error compensation, the hyperpatch model has been used to model the errors. From the experiments, the positional accuracy of the alignment stage can be improved significantly.

  • PDF

차단용량 향상을 위한 신소호 구조 (New Arc Chamber to Improve Breaking Capacity)

  • 박진영;조해용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.321-326
    • /
    • 2012
  • 배선용 차단기(MCCB)를 구성하는 개폐기구부, 아크(Arc)소호부, 트립(Trip)부는 차단기의 성능을 결정짓는 중요한 요소들이다. 그 중 아크소호부는 차단시 발생한 아크를 소호실 안쪽으로 유도하여 여러개의 짧은 아크로 분할시키며 아크를 냉각, 소멸시켜 차단을 빠르게 하는 구조이다. 본 연구에서는 새로운 소호구조를 제안하였고, 차단 성능이 우수한 변수에 대한 최적화 실험을 하였으며, 이를 토대로 실제 실험제품에 적용하여 성능 향상에 대한 연구를 수행하였다.

The Influence of Fuel Spray Characteristics on the Engine Performance and Emission in the Direct Injection Type Diesel Engine

  • Bakar Rosli Abu;Lee Chang-Sik
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.43-50
    • /
    • 1997
  • The purpose of this investigation is to carry out, the influence factor on the fuel spray characteristics for improve the engine combustion performance and exhaust omission in direct injection type diesel engine. The fuel properties, fuel spray structure and the shape or the piston surface of diesel engine play an important role of engine combustion process and exhaust emission. In order to obtain the effect of using auxiliary chamber and emulsified fuel on the fuel spray characteristics the experiment un conduct with single cylinder direct injection type diesel engine to examine the engine performance and gas emission. The results of this investigation showed that the increase auxiliary chamber volume and emulsified fuel give an effect on the fuel spray characteristics by reduced the concentration of nitric oxide emission in the combustion chamber. Also it can improve the combustion characteristics such as cylinder pressure, rate of pressure rise and rate of heat release.

  • PDF

배기소음기의 구조개선에 의한 소음감쇠 효과에 관한 연구 (A Study on Sound Attenuation by Structure Improvement of Silencer for Exhaust Fan)

  • 윤세철;이해경
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.32-38
    • /
    • 1995
  • The silencers are used to attenuate noise generated by the exhaust fan for industrial processes. The types of silencers applied in this study are absorptive duct silencer, expansion chamber, absorptive chamber and resonator. This study was carried out to verify the attenuation by the various silencers and elements. As a result, the difference of attenuation between the calculation and the measurement was about 1-7㏈. The attenuation by absorptive duct silencer and absorptive chamber was negligible at frequencies below 250Hz. The expansion chamber should be used for low frequency applications where the absorptive duct silencer was Ineffective. The attenuation by resonator may be realised when the ratio of frequency to resonant frequency approaches 1.

  • PDF

Design and construction of a new ultraviolet sensor using CsI deposition in the ionization chamber

  • Souri, R.;Negarestani, A.;Souri, S.;Farzan, M.;Mahani, M.
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.751-757
    • /
    • 2018
  • In this article, a UV sensor that is an appropriate tool for fire detection has been designed and constructed. The structure of this UV sensor is an air-filled single-wire detector that is able to operate under normal air condition. A reflective CsI photocathode is installed at the end of the sensor chamber to generate photoelectrons in the ion chamber. An electric current is produced by accelerating photoelectrons to the anode in the electric field. The detector is able to measure the intensity of the incident UV rays whenever the current is sufficiently high. Therefore, the sensitivity coefficient of this sensor is found to be $7.67{\times}10^{-6}V/photons/sec$.

마이크로 관류수차의 최적형상 및 성능향상에 관한 연구 (A Study on the Optimal Configuration and Performance Improvement of a Micro Cross-Flow Hydraulic Turbine)

  • 자오린후;이영호;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.296-303
    • /
    • 2006
  • Recently, micro hydropower attracts attention because of its clean. renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of micro hydropower and it is necessary to study for the effective turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the micro hydropower turbine. Therefore a cross-flow turbine is proposed for micro-hydropower in this study because of its simple structure and high possibility of applying to low head. The purpose of this study Is to further optimize the turbine structure and improve the performance. A guide vane is removed and the runner chamber is made compact using a new air supply method. The results show that the efficiency of the turbine is improved in a wide operating range and the size of the turbine is remarkably reduced.

Evaluation by Rocket Combustor of C/C Composite Cooled Structure for Combined-cycle Engine

  • Takegoshi, Masao;Ono, Fumiei;Ueda, Shuichi;Saito, Toshihito;Hayasaka, Osamu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.804-809
    • /
    • 2008
  • In this study, the cooling performance of a C/C composite material structure with metallic cooling tubes fixed by elastic force without chemical bonding was evaluated experimentally using combustion gas in a rocket combustor. The C/C composite chamber was covered by a stainless steel outer shell to maintain its airtightness. Gaseous hydrogen as a fuel and gaseous oxygen as an oxidizer were used for the heating test. The surface of these C/C composites was maintained below 1500 K when the combustion gas temperature was about 2900 K and heat flux to the combustion chamber wall was about 9 $MW/m^2$. No thermal damage was observed on the stainless steel tubes which were in contact with the C/C composite materials. Results of the heating test showed that such a metallic-tube-cooled C/C composite structure is able to control the surface temperature as a cooling structure(also as a heat exchanger), as well as indicating the possibility of reducing the amount of the coolant even if the thermal load to the engine is high. Thus, application of the metallic-tube-cooled C/C composite structure to reusable engines such as a rocket-ramjet combined cycle engine is expected.

  • PDF

17~18세기 조선왕릉의 봉릉 구조개선에 따른 사방석(四方石)의 등장과 소멸 (A study on the use of a Sabangseok and changes in the structure at the tumulus of the royal tomb during in the J oseon dynasty the 17th and 18th centuries)

  • 신지혜
    • 건축역사연구
    • /
    • 제30권4호
    • /
    • pp.67-78
    • /
    • 2021
  • This is a study on the structural changes of the tumulus and causes setting up a Sabangseok at the front of the tumulus at the royal tomb in the JoSeon dynasty, during the 17th~18th centuries. The Sabangseok was first used in the tumulus of Mongnueng(穆陵) in 1630. It is a multipurpose stone for boundary, foundation of the tumulus and blocking the sliding down of the tumulus. It was set up, when constructing a Yeongneung(寧陵) in 1673. But the vast spill of tumulus soil made it improve structure of the Sabangseok. Consequently, when the Yeongneung was re-constructed, the structure of the tumulus was fundamentally improved. The soil layer on the lime of the subterranean chamber became eliminated. Also the lime of the tumulus and the lime of the subterranean chamber became a united structure. The Sabangseok was still used until 1757 on account of precedents, although it would become unnecessary after structural improvement of the tumulus in 1673. In 1757, Yeongjo(The 21th monarch of the Joseon Dynasty) commanded repeal on the use of the Sabangseok, when constructing the Hongneung(tomb of Queen Jeongseong). The decision and discussions about abolition on the use of the Sabangseok was recorded in Gukjosangryebopyeon.

서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응 (Thermal and subjective responses by sun hats for farmer in a hot climatic chamber)

  • 김명주;최정화
    • 한국의류학회지
    • /
    • 제28권5호
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

배수관의 구조소음과 소음저감에 관한 연구 (A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes)

  • 류봉조;이규섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF