Journal of the Korean Society for Precision Engineering
/
v.33
no.11
/
pp.937-941
/
2016
Stand-alone cervical cage consists of a PEEK body, Ti plate, and screw, which are configured as a single-piece. Through a single operation, this implantable medical device is capable of completely fixing the cervical vertebral body. For example, instead of a plate, which is normally used, the intervertebral disc is removed and replaced with a cervical cage. It should be noted that in Korea, KFDA guidelines for a stand-alone cervical cage have not yet been suggested. Therefore, the aim of this study is to present the systematic study of the static compression test, static torsion test, dynamic compression test, and expulsion test. Further, the test method is designed to refer to the ASTM standard and relative literature.
Objective : The objective of this study was to validate the effects of a titanium mesh cage and dynamic plating in anterior cervical stabilization after corpectomy. Methods : A retrospective study was performed on 31 consecutive patients, who underwent anterior cervical reconstruction with a titanium mesh cage and dynamic plating, from March 2004 to February 2006. Twenty-four patients had 1-level and 7 had 2-level corpectomies. Ten patients underwent surgery with a cage of 10-mm diameter and 21 with 13-mm diameter. Neurological status and outcomes were assessed according to Odom's criteria. Sagittal angle, coronal angle, settling ratio, sagittal displacement, and cervical lordosis were used to evaluate the radiological outcomes. Results : In overall, 26 [83.9%] of 31 showed excellent or good outcomes. Thirteen percent [4 cases] of the patients developed surgical complications, such as hoarseness, transient dysphagia, or nerve root palsy. Seven [22.6%] patients had reconstruction failure:5 [20.8%] in the 1-level corpectomy group and 2 [28.5%] in the 2-level corpectomy group. Revisions were required in 2 patients with plate pullout due to significant instability. However, none of 5 patients who demonstrated cage displacement or screw pullout, underwent a revision. Radiographs revealed bony consolidation in 96.3% of the patients, including 6 patients with implantation failure during the follow-up period. Conclusion : Based on our preliminary results, the titanium mesh cage and dynamic plating was effective for cervical reconstruction after corpectomy. The anterior cervical reconstruction performed with dynamic plates is considered to reduce stress shielding and greater graft compression that is afforded by the unique plate design.
Kim, Soo-Han;Lee, Jung-Kil;Jang, Jae-Won;Park, Hyun-Woong;Hur, Hyuk
Journal of Korean Neurosurgical Society
/
v.60
no.2
/
pp.211-219
/
2017
Objective : This study aimed to compare the clinical and radiologic outcomes of patients with subaxial cervical injury who underwent anterior cervical discectomy and fusion (ACDF) with autologous iliac bone graft or polyetheretherketone (PEEK) cages using demineralized bone matrix (DBM). Methods : From January 2005 to December 2010, 70 patients who underwent one-level ACDF with plate fixation for post-traumatic subaxial cervical spinal injury in a single institution were retrospectively investigated. Autologous iliac crest grafts were used in 33 patients (Group I), whereas 37 patients underwent ACDF using a PEEK cage filled with DBM (Group II). Plain radiographs were used to assess bone fusion, interbody height (IBH), segmental angle (SA), overall cervical sagittal alignment (CSA, C2-7 angle), and development of adjacent segmental degeneration (ASD). Clinical outcome was assessed using a visual analog scale (VAS) for pain and Frankel grade. Results : The mean follow-up duration for patients in Group I and Group II was 28.9 and 25.4 months, respectively. All patients from both groups achieved solid fusion during the follow-up period. The IBH and SA of the fused segment and CSA in Group II were better maintained during the follow-up period. Nine patients in Group I and two patients in Group II developed radiologic ASD. There were no statistically significant differences in the VAS score and Frankel grade between the groups. Conclusion : This study showed that PEEK cage filled with DBM, and plate fixation is at least as safe and effective as ACDF using autograft, with good maintenance of cervical alignment. With advantages such as no donor site morbidity and no graft-related complications, PEEK cage filled with DBM, and plate fixation provide a promising surgical option for treating traumatic subaxial cervical spine injuries.
Objective : Anterior cervical discectomy and fusion (ACDF) is often complicated by subsidence, pseudoarthrosis, kyphosis, and graft donor site morbidities. To decrease the occurrence of these complications, various types of cages have been developed. We designed this retrospective study to analyze and compare the efficacy and outcomes of ACDF using double cylindrical cages (DCC) (BK Medical, Seoul, Korea) versus an anterior cervical plating system with autogenous iliac crest grafts. Methods : Forty-eight patients were treated with autograft and plating (plate group), and 48 with DCC group from October 2007 to October 2011. We analyzed construct length, cervical lordotic curvarture, the thickness of the prevertebral soft tissue, segmental instability, and clinical outcomes. Results : There were no significant differences between the two groups with regard to the decrease in construct length or cervical lodortic curvature at the 3-, 6-, and 12-month follow-ups. The prevertebral soft tissue was thinner in the DCC group than the plate group immediately after surgery and at the 3-, 6-, and 12-month follow-ups. The difference in interspinous distance on flexion-extension was shorter in the plate group than the DCC group at the 3- and 6-month follow-ups. However, there was no significant difference in this distance between the two groups at the 12-month follow-up. Conclusion : A double cylindrical cage is a good alternative for fusion in patients with cervical degenerative diseases; the surgical method is relatively simple, allows good synostosis, has less associated prevertebral soft tissue swelling, and complications associated with autografting can be avoided.
Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
Neurospine
/
v.15
no.4
/
pp.368-375
/
2018
Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.
We report a case of 29-year-old man diagnosed as a primary eosinophilic granuloma (EG) lesion of the seventh cervical vertebra. He had paresthesia on both arms, and grasping weakness for 10 days. Cervical magnetic resonance image (MRI) showed an enhancing mass with ventral epidural bulging and cord compression on the seventh cervical vertebra. Additionally, we performed spine series MRI, bone scan and positive emission tomography for confirmation of other bone lesions. These studies showed no other pathological lesions. He underwent anterior cervical corpectomy of the seventh cervical vertebra and plate fixation with iliac bone graft. After surgical management, neurological symptoms were much improved. Histopathologic evaluation confirmed the diagnosis of EG. There was no evidence of tumor recurrence at 12 months postoperative cervical MRI follow-up. We reported symptomatic primary EG of cervical spine successfully treated with surgical resection.
Park, Joo-Tae;Ahn, Gil-Young;Lee, Young-Tae;Ahn, Myun-Whan
Journal of Yeungnam Medical Science
/
v.14
no.1
/
pp.209-219
/
1997
Objectives: Anterior approach to achieve arthrodesis of the cervical spine has become a widely accepted and often-used approach since its earliest reports by Bailey and Badgley, Smith and Robinson and Cloward. However, anterior interbody fusion in the presence of the posterior instability may be complicated by the bone graft dislodgement, kyphotic defomity or nonunion. As an attemp to prevent this undesirable complication, additional methods such as skeletal traction, halo appratus or even posterior fusion has been utilized. Therefore, The cervical spine locking plate(CSLP) with the anterior intervertebral body bone grafting provide immediate cervical stabilization and widely successful in achieving fusion. Material and methods: This study analysed 14 patients who underwent a single anterior procedure and application of CSLP for the treatment of the cervical spinal disorder. Eleven patients were disc herniations and three patients were traumatic lesion. The average age of the patient was 47 years and the mean follow up periods was 20 months ranging from 13 to 27 months. Results: Ambulation was started 2nd day after the operation with the aid of the Philadelpia orthoses. Bone union was observed 13 cases on average 12 weeks after operation. The one case was nonunion with plate breakage without clinical symptom. Conclusion: Anterior fusion with CSLP are thought to be a safe and valuable method for treating cervical spine disorder.
Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.
Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
Journal of Korean Neurosurgical Society
/
v.46
no.4
/
pp.300-304
/
2009
Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.
Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
Journal of Korean Neurosurgical Society
/
v.37
no.3
/
pp.217-222
/
2005
Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.