• Title/Summary/Keyword: Cervical pedicle

Search Result 43, Processing Time 0.021 seconds

Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method

  • Paik, Seung-Chull;Chun, Hyoung-Joon;Bak, Koang Hum;Ryu, Jeil;Choi, Kyu-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.6
    • /
    • pp.460-464
    • /
    • 2015
  • Objective : Bilateral C1 lateral mass and C2 pedicle screw fixation (C1LM-C2P) is an ideal technique for correcting atlantoaxial instability (AAI). However, the inevitable situation of vertebral artery injury or unfavorable bone structure may necessitate the use of unilateral C1LM-C2P. This study compares the fusion rates of the C1 lateral mass and C2 pedicle screw in the unilateral and bilateral methods. Methods : Over five years, C1LM-C2P was performed in 25 patients with AAI in our institute. Preoperative studies including cervical X-ray, three-dimensional computed tomography (CT), CT angiogram, and magnetic resonance imaging were performed. To evaluate bony fusion, measurements of the atlanto-dental interval (ADI) and CT scans were performed in the preoperative period, immediate postoperative period, and postoperatively at 1, 3, 6, and 12 months. Results : Unilateral C1LM-C2P was performed in 11 patients (44%). The need to perform unilateral C1LM-C2P was due to anomalous course of the vertebral artery in eight patients (73%) and severe degenerative arthritis in three patients (27%). The mean ADI in the bilateral group was 2.09 mm in the immediate postoperative period and 1.75 mm in 12-months postoperatively. The mean ADI in the unilateral group was 1.82 mm in the immediate postoperative period and 1.91 mm in 12-months postoperatively. Comparison of ADI measurements showed no significant differences in either group (p=0.893), and the fusion rate was 100% in both groups. Conclusion : Although bilateral C1LM-C2P is effective for AAI from a biomechanical perspective, unilateral screw fixation is a useful alternative in patients with anatomical variations.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap (유리 공장 피판술 후 외부 감시 피판의 유용성)

  • Kim, Baek Kyu;Chang, Hak;Minn, Kyung Won;Hong, Joon Pio;Koh, Kyung Suck
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

Management of Traumatic C6-7 Spondyloptosis with Cord Compression

  • Choi, Man-Kyu;Jo, Dae-Jean;Kim, Min-Ki;Kim, Tae-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.289-292
    • /
    • 2014
  • A case of total spondyloptosis of the cervical spine at C6-7 level with cord compression is described in a 51-year-old male. Because the bodies of C6 and 7 were tightly locked together, cervical traction failed. Then the patient was operated on by a posterior approach. Posterior stabilization and fusion were performed by C4-5 lateral mass and C7-T1 pedicle screw fixation and rod instrumentation with bridging both C4-5's rods to the C7-T1's extended ones. After C6 total laminectomy and foraminotomy, the C6 body was returned to its proper position. Secondly, anterior stabilization and fusion were performed by C6-7 discectomy with a screw-plate system. A postoperative lateral plain radiograph showed good realignment. In this case, we report the clinical presentation and discuss the surgical modalities of C6-7 total spondyloptosis and the failed close reduction.

Endovascular Treatment of Symptomatic High-Flow Vertebral Arteriovenous Fistula as a Complication after C1 Screw Insertion

  • Jang, Hyun Jun;Oh, Se-Yang;Shim, Yu Shik;Yoon, Seung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.348-352
    • /
    • 2014
  • High-flow vertebral arteriovenous fistulas (VAVF) are rare complications of cervical spine surgery and characterized by iatrogenic direct-communication of the extracranial vertebral artery (VA) to the surrounding venous plexuses. The authors describe two patients with VAVF presenting with ischemic presentation after C1 pedicle screw insertion for a treatment of C2 fracture and nontraumatic atlatoaxial subluxation. The first patient presented with drowsy consciousness with blurred vision. The diffusion MRI showed an acute infarction on bilateral cerebellum and occipital lobes. The second patient presented with pulsatile tinnitus, dysarthria and a subjective weakness and numbness of extremities. In both cases, digital subtraction angiography demonstrated high-flow direct VAVFs adjacent to C1 screws. The VAVF of the second case occurred near the left posterior inferior cerebellar artery originated from the persistent first intersegmental artery of the left VA. Both cases were successfully treated by complete occlusion of the fistulous portion and the involved segment of the left VA using endovascular coil embolization. The authors reviewed the VAVFs after the upper-cervical spine surgery including C1 screw insertion and the feasibility with the attention notes of its endovascular treatment.

Surgical Treatment of Eosinophilic Granuloma in Cervical Spine - 3 Cases Report - (경추에서 발생한 호산구 육아종의 수술적 치료 - 3예 보고 -)

  • Chung, Jae-Yoon;Lee, Jae-Joon;Kim, Jong-Seon;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2006
  • The involvement in the spine of eosinophilic granuloma is not common. Especially, involvement of cervical spine and posterior neural arch is quite rare. In addition, radiographic findings including magnetic resonance images of eosinophilic granuloma are manifested as vertebral body collapse, loss of pedicle and paravertebral soft mass formation; it must be differentiated with other conditions, such as malignant bone tumor, metastatic cancer or tuberculous spondylitis. We experienced three cases of eosinophilic granuloma involving posterior neural arch of C4, C7, and body of C4 respectively, which were performed surgical treatment and achieved complete healing. We report these cases with review of literatures.

  • PDF

The lateral intercostal artery perforator as an alternative donor vessel for free vascularized lymph node transplantation

  • Kwak, Min-Seok Daniel;Machens, Hans-Guenther
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.275-279
    • /
    • 2018
  • Chronic lymphedema is caused by an impairment of the lymphatic system due to primary or secondary causes. Vascularized lymph node transplantation (VLNT) is currently the most promising and frequently used technique besides lymphaticovenous anastomosis. However, the vessel anatomy in the lateral thoracic region is sometimes quite variable. Based on our experiences with vascular anatomical inconstancy in the lateral thoracic region, we planned a lateral intercostal artery perforator flap for VLNT in a female patient with chronic stage II lymphedema of both legs after cervical cancer treatment. After surgery, the patient reported significant improvement in limb volume and the accompanying symptoms. The limb circumference was reduced by an average of 19.2% at 6 months postoperatively. Despite having a short pedicle and small vessel caliber, the lateral intercostal artery perforator flap can safely be used for VLNT in lymphedema patients with anatomical variants.

Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines (International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구)

  • Oh, Se An;Kang, Min Kyu;Kim, Sung Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.145-153
    • /
    • 2013
  • Stereotactic body radiation therapy (SBRT) is increasingly used to treat spinal metastases. To achieve the highest steep dose gradients and conformal dose distributions of target tumors, intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques are essential to spine radiosurgery. The purpose of the study was to qualitatively compare IMRT and VMAT techniques with International Spine Radiosurgery Consortium (ISRC) contoured consensus guidelines for target volume definition. Planning target volume (PTV) was categorized as TB, $T_{BPT}$ and $T_{ST}$ depending on sectors involved; $T_B$ (vertebral body only), $T_{BPT}$ (vertebral body+pedicle+transverse process), and $T_{ST}$ (spinous process+transverse process). Three patients treated for spinal tumor in the cervical, thoracic, and lumbar region were selected. Eacg tumor was contoured by the definition from the ISRC guideline. Maximum spinal cord dose were 12.46 Gy, 12.17 Gy and 11.36 Gy for $T_B$, $T_{BPT}$ and $T_{ST}$ sites, and 11.81 Gy, 12.19 Gy and 11.99 Gy for the IMRT, RA1 and RA2 techniques, respectively. Average fall-off dose distance from 90% to 50% isodose line for $T_B$, $T_{BPT}$, and $T_{ST}$ sites were 3.5 mm, 3.3 mm and 3.9 mm and 3.7 mm, 3.7 mm and 3.3 mm for the IMRT, RA1 and RA2 techniques, respectively. For the most complicated target $T_{BPT}$ sites in the cervical, thoracic and lumbar regions, the conformity index of the IMRT, RA1 and RA2 is 0.621, 0.761 and 0.817 and 0.755, 0.796 and 0.824 for rDHI. Both IMRT and VMAT techniques delivered high conformal dose distributions in spine stereotactic radiosurgery. However, if the target volume includes the vertebral body, pedicle, and transverse process, IMRT planning resulted in insufficient conformity index, compared to VMAT planning. Nevertheless, IMRT technique was more effective in reducing the maximum spinal cord dose compared to RA1 and RA2 techniques at most sites.

Selection of Recipient Vessels in Delayed Breast Reconstruction with Free TRAM Flap (횡복직근 유리피판을 이용한 지연유방재건에서 수용부 혈관의 선택)

  • Ahn, Hee Chang;Lee, Han Earl;Kim, Jeong Tae;Choi, M.Seung Suk
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.569-573
    • /
    • 2007
  • Purpose: The selection of the recipient vessels in breast reconstruction has a great influence on the surgical result and the shape of the reconstructed breast. We would like to introduce the criteria for the selection of recipient vessels in delayed reconstruction of the breast. Methods: We studied 56 patients with delayed breast reconstruction using free TRAM flaps from April 1994 to December 2006. The thoracodorsal and the ipsilateral internal mammary vessels were used as recipients in 25 patients each, the opposite internal mammary vessels in 3 patients, the thoracoacromial vessels in 2 patients, and the transverse cervical artery with the cephalic vein in 1 patient. The survival rate of the flaps, the vessel diameter, the length of the pedicles, and the convenience of vessel dissection were studied. Results: The diameter of the recipient vessel did not influence the anastomosis. The operation time, the survival rate of flap, the postoperative complications showed no significant difference according to the recipient vessel. Dissection of the thoracodorsal vessels was tedious due to scar formation from the prior operation. Dissection of the internal mammary vessels proved to be relatively easy, and the required length of the pedicle was shorter than any other site, but the need for removal of rib cartilage makes this procedure inconvenient. Conclusion: The first choice of the recipient vessel in immediate breast reconstruction is the thoracodorsal vessels, but in cases of delayed reconstruction the internal mammary vessels are favored as the first choice, because the thoracodorsal vessels have a high unusability rate. If the ipsilateral internal mammary vessels prove to be useless, the contralateral vessels can be used. The thoracoacromial vessels are useful, when the mastectomy scar is located in the upper portion. The transverse cervical artery and the cephalic vein can serve as the last resort, if all other vessels are unreliable.

Rod Migration into the Posterior Fossa after Harms Operation : Case Report and Review of Literatures

  • Chun, Hyoung-Joon;Bak, Koang-Hum;Kang, Tae-Hoon;Yi, Hyeong-Joong
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.221-223
    • /
    • 2010
  • C1 lateral mass and C2 pedicle (C1LM-C2P) fixation is a relatively new technique for atlantoaxial stabilization. Complications from C1LM-C2P fixation have been rarely reported. The authors report unilateral rod migration into the posterior fossa as a rare complication after this posterior C1-C2 stabilization technique. A 23-year-old man suffered severe head trauma and cervical spine injury after vehicle accident. He was unconscious for 2 months and regained consciousness. He underwent C1LM-C2P fixation for stabilization of type II odontoid process fracture described by Harms. The patient recovered without a major complication. Twenty months after operation, brain computed tomogram performed at psychology department for disability evaluation showed rod migration into the right cerebellar hemisphere. The patient had mild occipital headache and dizziness only regarding the misplaced rod. He refused further operation for rod removal. To our knowledge, this complication is the first report regarding rod migration after Harms method. We should be kept in mind the possibility of rod migration, and C1LM-C2P fixation should be performed with meticulous technique and long-term follow-up.