• Title/Summary/Keyword: Ceramic-heater

Search Result 70, Processing Time 0.028 seconds

Limit-current type zirconia oxygen sensor with porous diffusion layer (다공성 확산층을 이용한 한계전류형 지르코니아 산소센서)

  • Oh, Young-Jei;Lee, Chil-Hyoung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.329-337
    • /
    • 2008
  • Simple, small and portable oxygen sensors were fabricated by tape casting technique. Yttria stabilized zirconia containing cordierite ceramics (YSZC) were used as a porous diffused layer of oxygen in pumping cell. Yttria stabilized zirconia (YSZ) solid electrolyte, YSZC porous diffusion layer and heater-patterned ceramic sheets were prepared by co- firing method. Limit current characteristics and the linear relationship of current to oxygen concentration were observed. Viscosity variation of the slurries both YSZ and YSZC showed a similar behavior, but micro pores in the fired sheet were increased with increasing of the cordierite amount. Molecular diffusion was dominated due to the formation of large pores in porous diffusion layer. The plateau range of limit current in porous-type oxygen sensor was narrow than the one of aperture-type oxygen sensor. However limit current curve was appeared in porous-type oxygen sensor even at the lower applied voltage. The plateau range of limit-current was widen as increasing the thickness of porous diffusion layer of the YSZ containing cordierite. Measuring temperature of $600{\sim}650^{\circ}C$ was recommended for limit-current oxygen sensor. Porous diffusion layer-type oxygen sensor showed faster response than the aperture-type one and was stable up to 30 days running without any crack at interface between the layers.

Performance Analysis of High Efficiency Co-generation System Using the Experimental Design Method (실험계획법을 이용한 고효율 소형 열병합 시스템 성능 해석)

  • Ryu, Mi-Ra;Lee, Jun-Sik;Park, Jeong-Ho;Lee, Seong-Beom;Lee, Dae-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.20-25
    • /
    • 2012
  • As a kind of distributed energy system, the co-generation system based Diesel engine using after-treatment device was devised for its environmental friendly and economic qualities. It is utilized in that the electric power is produced by the generator connected to the Diesel engine, and waste heat is recovered from both the exhaust gases and the engine itself by the finned tube and shell & tube heat exchangers. An after-treatment device composed ceramic heater and DOC(Diesel Oxidation Catalyst) is installed at the engine outlet in order to completely reignite the unburned fuel from the Diesel engine. In this study, mutual relation of each experimental condition was derived through minimum number of experiment using Taguchi Design and ANOVA recently used in the various fields. It is found that the total efficiency (thermal efficiency plus electric power generation efficiency) of this system reaches maximum 94.4% which is approximately higher than that of the typical diesel engine exhaust heat recovery system.

A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production (SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석)

  • BYUN, HYUN SEUNG;HAN, DANBEE;PARK, SEONGRYONG;CHO, CHONGPYO;BAEK, YOUNGSOON
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.2
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.

A Study on the contamination measurement of spacecraft components under High Vacuum Environment (고진공하에서의 위성체 부품의 오염측정에 관한 연구)

  • 이상훈;서희준;문귀원;최석원
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • Outgassing from such sources as paints, coatings, adhesives and other non-metallic surfaces can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. The vacuum bake-out test using high temperature(more than $85 ^{\circ}C$)and high vacuum(less than $5.0{\times}1-^{-3}$ Pa) certify that the components of satellite work properly and can survive and operate in space environment like high vacuum. In the bake-out chamber installed at SITC of KARI, Rotary vacuum pump and Booster pump produce low vacuum of 5.0 Pa, and then two cryopumps produce high vacuum of below $5.0{\times}10^{-3}$ Pa. Also 48 ceramic heaters were provided to simulate high temperature. During the vacuum bake-out test, we detected contaminants using RGA(Residual Gas Analyzer) and measure the outgassing rate of the contaminant using the TQCM(Thermoelectric Quartz Crystal Microbalance). Also, IR/UV Spectrometer and witness plate be used to certify that the components were suitable for the spacecraft. This paper includes the preparation and procedures of the bake-out test for SAR(Solar Array Regulator) and MLI(Multi Layer Insulator), which were the components of the spacecraft. Especially, we discussed the methods and results of the contamination measurement. In the bake-out for SAR, the contamination was measured continuously although it was on the decrease from TQCM results. And RCA established that it is a highly polymerized compound. In the MLI bake-out using RGA and witness plate, we didn't detect any contamination materials.

The Development of an Electroconductive SiC-ZrB2 Composite through Spark Plasma Sintering under Argon Atmosphere

  • Lee, Jung-Hoon;Ju, Jin-Young;Kim, Cheol-Ho;Park, Jin-Hyoung;Lee, Hee-Seung;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.342-351
    • /
    • 2010
  • The SiC-$ZrB_2$ composites were fabricated by combining 30, 35, 40, 45 and 50 vol. % of zirconium diboride ($ZrB_2$) powders with silicon carbide (SiC) matrix. The SiC-$ZrB_2$ composites and the sintered compacts were produced through spark plasma sintering (SPS) under argon atmosphere, and its physical, electrical, and mechanical properties were examined. Also, the thermal image analysis of the SiC-$ZrB_2$ composites was examined. Reactions between $\beta$-SiC and $ZrB_2$ were not observed via x-ray diffraction (XRD) analysis. The apparent porosity of the SiC+30vol.%$ZrB_2$, SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$, SiC+45vol.%$ZrB_2$ and SiC+50vol.%$ZrB_2$ composites were 7.2546, 0.8920, 0.6038, 1.0981, and 10.0108%, respectively. The XRD phase analysis of the sintered compacts demonstrated a high phase of SiC and $ZrB_2$. Among the $SiC+ZrB_2$ composites, the SiC+50vol.%$ZrB_2$ composite had the lowest flexural strength, 290.54MPa, the other composites had more than 980MPa flexural strength except the SiC+30vol.%$ZrB_2$ composite; the SiC+40vol.%$ZrB_2$ composite had the highest flexural strength, 1011.34MPa, at room temperature. The electrical properties of the SiC-$ZrB_2$ composites had positive temperature coefficient resistance (PTCR). The V-I characteristics of the SiC-$ZrB_2$ composites had a linear shape in the temperature range from room to $500^{\circ}C$. The electrical resistivities of the SiC+30vol.%$ZrB_2$, SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$ SiC+45vol.%$ZrB_2$ and SiC+50vol.%$ZrB_2$ composites were $4.573\times10^{-3}$, $1.554\times10^{-3}$, $9.365\times10^{-4}$, $6.999\times10^{-4}$, and $6.069\times10^{-4}\Omega{\cdot}cm$, respectively, at room temperature, and their resistance temperature coefficients were $1.896\times10^{-3}$, $3.064\times10^{-3}$, $3.169\times10^{-3}$, $3.097\times10^{-3}$, and $3.418\times10^{-3}/^{\circ}C$ in the temperature range from room to $500^{\circ}C$, respectively. Therefore, it is considered that among the sintered compacts the SiC+35vol.%$ZrB_2$, SiC+40vol.%$ZrB_2$ and SiC+45vol.%$ZrB_2$ composites containing the most outstanding mechanical properties as well as PTCR and V-I characteristics can be used as an energy friendly ceramic heater or ohmic-contact electrode material through SPS.

A Study on the Moxa-extract Moxibustion Method (약쑥엑스제 뜸 방식에 관한 연구)

  • Jo, Bong-Kwan;Lee, Yoon-Ho;Yoon, Dong-Eop
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.1-14
    • /
    • 2006
  • Objectives : We implemented the Moxa-Extract Moxibustion Method in order to improve the conventional moxibustion therapy. This method is aimed to eliminate burning wounds and smoke, which are the defects of conventional moxibustion therapy. And we performed to verify the efficiency by comparing the Moxa-Extract Moxibustion Method with the conventional Indirect Moxibustion Method. We measured the body heat and the lasting time of blood circulation improveent using thermography. We implemented the Moxa-Extract Moxibustion Method in order to improve the conventional moxibustion therapy. This method is aimed to eliminate burning wounds and smoke, which are the defects of conventional moxibustion therapy. And we performed to verify the efficiency by comparing the Moxa-Extract Moxibustion Method with the conventional Indirect Moxibustion Method. We measured the body heat and the lasting time of blood circulation improvement using thermography. Methods : The moxibustion therapy has two kinds of effects: The formers are pharmacological effects of the Moxa's vasodilators and antioxidants. The latters are thermal effects which cause improvement of the blood circulation. To remove the demerits without omission of above therapeutic effects, we extracted the vasodilators and antioxidant compounds from the Moxa-CH2Cl2 fraction Moxa-EtOA and composed the moxibustion kit with (Ba0.8 Sr0.2)0.996 Y0.004 TiO2 + 0.5WT SiO2% positive Temperature Coefficients Thermistor. The experimental demonstrations have been made by the stimulating the spot which is CV4(Kwan-Won), CV8(Shin-Guel), CV12(Jung-Wan) acupuncture points of the conception vessel meridian(CV). And stimulating time was one hour. We divided the subjects into 5 groups such as no stimulation group, conventional Indirect Moxibustion group, only Moxa-Extract stimulation group, only heat stimulation group, and Moxa-Extract Moxibustion group. In the different cases, we have measured the body heat in pre-stimulation, just after stimulation, 2 hours after, and 4 hours after. Results : he body heats of the group who were stimulated by the Moxa-Extract Moxibustion method were increased by over the $2^{\circ}C$. And the body heats of the group who were stimulated by the Indirect Moxibustion Method were increased by average the $1^{\circ}C$. We have evaluated that the Moxa-Extract Moxibustion Method is improvement on the Indirect Moxibustion Method by the increasing rate is 200% and increasing time is 150% with the body heat of the abdominal region. Conclusion : We have implemented the Moxa-Extract Moxibustion Method and evaluated the efficiency of the Moxa-Extract Moxibustion Method comparing with the Indirect Moxibustion Method.

  • PDF

Electrical Properties of $Ba_{1-x}(Bi_{0.5}K_{0.5})TiO_3$ according to $(Bi_{0.5}K_{0.5})TiO_3$ for Pb-free PTC (Pb-free PTC에 있어서 $(Bi_{0.5}K_{0.5})TiO_3$ 첨가에 따른 $Ba_{1-x}(Bi_{0.5}K_{0.5})TiO_3$의 전기적특성)

  • Lee, Mi-Jai;Choi, Byung-Hyun;Paik, Jong-Hoo;Kim, Bip-Nam;Lee, Woo-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.35-36
    • /
    • 2008
  • PTC thermistor are characterized by an increase in the electrical resistance with temperature. The PTC materials of middle Curie point were produced or that of high Curie point (above $200^{\circ}C$), it was determined that compositional modifications of $Pb^{2+}$ for $Ba^{2+}$ produce change sin the Curie point to higher temperature. PTC ceramic materials with the Curie point above $120^{\circ}C$ were prepared by adding $PbTiO_3$, PbO or $Pb_3O_4$ into $BaTiO_3$. Thereby, adding $Pb^{2+}$ into $BaTiO_3$-based PTC material to improve Tc was studied broadly, however, weal know that PbO was poisonous and prone to volatilize, then to pollute the circumstance and hurt to people, so we should dope other innocuous additives instead of lead to increase Tc of composite PTC material. In order to prepare lead-free $BaTiO_3$-based PTC with middle Curie point, the incorporation on $Bi_{1/2}K_{1/2}TiO_3$ into $BaTiO_3$-based ceramics was investigated on samples containing 0, 1, 2, 3, 4, and 50mol% of $Bi_{1/2}K_{1/2}TiO_3$. $Bi_{1/2}K_{1/2}TiO_3$ was compounded as standby material by conventional solid-state reaction technique. The starting materials were $Bi_2O_3$, $K_2CO_3$, $BaCO_3$ and $TiO_2$ powder, and using solid-state reaction method, too. The microstructures of samples were investigated by SEM, DSC, XRD and dielectric properties. Phase composition and lattice parameters were investigated by X-ray diffraction.

  • PDF

A Study on the Variations of the Body Trunk Temperature by the Drug-Pad Moxibustion Method (약패드 뜸 방식을 이용한 체간온도변화에 대한 연구)

  • Yoon Dong-Eop;Jo Bong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.8
    • /
    • pp.386-396
    • /
    • 2006
  • We implemented the Drug-Pad Moxibustion Method in order to improve the conventional moxibustion therapy. This method is aimed to eliminate burning wounds and smoke, which are the defects of conventional moxibustion therapy. And we performed to verify the efficiency by comparing the Drug-Pad Moxibustion Method with the conventional Indirect Moxibustion Therapy. We measured the body heat and the lasting time of blood circulation improvement using thermography. The moxibustion therapy has two kinds of effects: The formers are pharmacological effects of the Moxa's vasodilators and antioxidants. The latters are thermal effects which cause improvement of the blood circulation. To remove the demerits without omission of above therapeutic effects, we extracted the vasodilators and antioxidant compounds from the Moxa-$CH_2Cl_2$ fraction Moxa-EtOAc and composed the moxibustion kit with $(Ba_{0.8}\;Sr_{0.2})_{0.996}\;Y_{0.004}\;TiO_2+0.5_{WT}\;SiO_2%$ Positive Temperature Coefficients Thermistor. The experimental demonstrations have been made by the stimulating the spot which is CV4(Kwan-Won), CV8(Shin-Guel), CV12(Jung-Wan) acupuncture points of the conception vessel meridian(CV). And stimulating time was one hour. We divided the subjects into 5 groups such as no stimulation group, conventional Indirect Moxibustion group, only Drug-Pad stimulation group, only heat stimulation group, and Drug-Pad Moxibustion group. In the different cases, we have measured the body heat in pre-stimulation, just after stimulation, 2 hours after, and 4 hours after. The body heats of the group who were stimulated by the Drug-Pad Moxibustion Method were increased by over the $2^{\circ}C$. And the body heats of the group who were stimulated by the Indirect Moxibustion Method were increased by average the $1^{\circ}C$. We have evaluated that the Drug-Pad Moxibustion Method is improvement on the conventional Indirect Moxibustion Method by the heat-increasing rate is 200% and the lasting time is 150% with the body heat of the abdominal region. In the conclusions, We have implemented the Drug-Pad Moxibustion Method and evaluated the efficiency of the Drug-Pad Moxibustion Method comparing with the conventional Indirect Moxibustion Method.

Effect of $BaTiO_3$ according to $(Bi_{0.5}Na_{0.5})TiO_3$ for Pb-free PTC (Pb-free PTC에 있어서 $(Bi_{0.5}Na_{0.5})TiO_3$ 첨가에 따른 $BaTiO_3$ 효과)

  • Lee, Mi-Jai;Paik, Jong-Hoo;Kim, Sei-Ki;Kim, Bip-Nam;Lee, Woo-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.57-58
    • /
    • 2008
  • PTC thermistor are characterized by an increase in the electrical resistance with temperature. The PTC materials of middle Curie point were produced or that of high Curie point (above $200^{\circ}C$), it was determined that compositional modifications of $Pb^{2+}$ for $Ba^{2+}$ produce change sin the Curie point to higher temperature. PTC ceramic materials with the Curie point above $120^{\circ}C$ were prepared by adding $PbTiO_3$, PbO or $Pb_3O_4$ into $BaTiO_3$. Thereby, adding $Pb^{2+}$ into $BaTiO_3$-based PTC material to improve Tc was studied broadly, however, weal know that PbO was poisonous and prone to volatilize, then to pollute the circumstance and hurt to people, so we should dope other innocuous additives instead of lead to increase Tc of composite PTC material. In order to prepare lead-free $BaTiO_3$-based PTC with middle Curie point, the incorporation on $Bi_{1/2}Na_{1/2}TiO_3$ into $BaTiO_3$-based ceramics was investigated on samples containing 0, 1, 2, 3, 4, and 50mol% of $Bi_{1/2}Na_{1/2}TiO_3$. $Bi_{1/2}Na_{1/2}TiO_3$ was compounded as standby material by conventional solid-state reaction technique. The starting materials were $Bi_{1/2}Na_{1/2}TiO_3$, $BaCO_3$, $TiO_2$ and $Y_2O_3$ powder, and using solid-state reaction method, too. The microstructures of samples were investigated by SEM, DSC, XRD and dielectric properties. Phase composition and lattice parameters were investigated by X-ray diffraction.

  • PDF

A Review on the Characteristics of Temperature Variation in Warm Needle (온침의 온도변화 특성에 대한 문헌 고찰 연구)

  • Lee, Ju Hyun;Jo, Hyo Rim;Kim, Seon Hye;Lee, Yeon Sun;Park, Se Won;Moon, So Ri;Jung, Chan Yung;Sung, Won Suk;Cho, Hyun Seok;Kim, Kyung Ho;Lee, Byung Wook;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.112-138
    • /
    • 2019
  • Objectives: The purpose of this study is to organize the research methods and results of studies related to the temperature of the warm needle for systematic utilization of warm needling technique. Methods: This study used the databases of nine (Pubmed, Science Direct, Cochrane Central, 4 Korean databases, CNKI, CiNii) to analyze temperature-related studies of the warm needle from 2000 to June 2019. Results: A total of 19 papers were included. Of these, 15 were used for mugwort, 2 for high frequency, and 1 for both mugwort and high frequency, and the other one for a ceramic heater. The maximum temperature rises as the amount of moxibustion increases. It is also affected by the density of moxa and the ignition part. There were 16 papers using stainless steel needles and 4 papers using a needle made of gold or silver to compare. In the area of the needle, the closer it is to moxibustion, the hotter it is. Compared to stainless steel needles, gold and silver needles showed almost twice the temperature. The effects of environment and radiant heat should be considered during warm needle procedures. Conclusions: There are various experimental methods such as warm needle technique materials, methods, measuring parts, measuring instruments, etc. The results were also very diverse. When setting the heating source, ignition part, size of moxibustion, etc. of warm needles, it should be implemented in a way that takes safety and validity into account. Considerations for temperature characteristics, radiant heat, etc. of warm needles will be needed when making warm needle apparatus.