• 제목/요약/키워드: Ceramic Coupler

검색결과 32건 처리시간 0.024초

High Power Continuous-Wave and Graphene Q-switched Operation of Er:YAG Ceramic Lasers at ~1.6 ㎛

  • Wang, Yong;Chen, Hao;Shen, Deyuan;Zhang, Jian;Tang, Dingyuan
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.5-9
    • /
    • 2013
  • We report on high-power continuous-wave operations of an Er:YAG ceramic laser in-band pumped by a cladding-pumped Er,Yb fiber laser at 1532 nm. With an output coupler of 10% transmission, the ceramic laser yielded 16.7 W of continuous-wave output at 1645 nm for 28.8 W of incident pump power, corresponding to a slope efficiency of 61.0% with respect to the incident pump power. The lasing wavelength switched to 1617 nm when output couplers of > 20% transmission were used. Up to 16.2 W of 1617 nm output was generated for 33.0 W of incident pump power, corresponding to a slope efficiency of 51.8%. Graphene Q-switched operation of Er:YAG cermic laser at 1645 nm was also demonstrated with stable pulses of 30-74 kHz repetition rates and 1.5-6.4 ${\mu}s$ pulse widths.

스퍼터링 방법을 이용한 중금속 산화물 유리 박막의 증착 (Deposition of Heavy Metal Oxide Glass Thin Films by R.F. Magnetron Sputtering)

  • 김웅권;허종;제정호
    • 한국세라믹학회지
    • /
    • 제32권6호
    • /
    • pp.669-676
    • /
    • 1995
  • In this study, EO glass films were deposited by R.F. magnetron sputtering using EO glass target. The glass formation of the EO film was greatly dependent on the substrate temperature and the crystallization started at approximately 28$0^{\circ}C$. As the temperature of the substrate or the oxygen content in the sputtering gas increased, UV/VIS/NIR absorption edge moved toward longer wavelength. A wave guiding phenomenon was observed from the prism-coupler experiment and a fluorescence of 1.06${\mu}{\textrm}{m}$ originated from 4Fe3/2longrightarrow4I11/2 transition of Nd3+ was detected from the film containing Nd3+ ions.

  • PDF

PECVD 법에 의해 제작된 저굴절률 차이 평판 SiON광도파로 (Low Index Contrast Planar SiON Waveguides Deposited by PECVD)

  • 김용탁;윤석규;윤대호
    • 한국세라믹학회지
    • /
    • 제42권3호
    • /
    • pp.178-181
    • /
    • 2005
  • Silicon oxynitride (SiON) 막은 플라즈마 화학기상증착법(PECVD)으로 $SiH_4,\;N_2O$$N_2$ 가스를 사용하여 $SiO_2/Si$ 위해 증착되었다. 증착 변수에 따라서 SiON 막의 굴절률은 prism coupler를 사용하여 1552nm 파장에서 $1.4480\~1.4958$까지 변화하였다. 평판 광도파로 코어로 사용되는 SiON 막의 두께는 $6{\mu}m$이고, buffer 막과의 굴절률 차이(An)는 $0.36\%$이다. 또한 식각 공정으로 $SiO_2$ 막 위에 증착된 SiON 막은 건식식각을 통해서 수행되었다. 광화이버에 $1.55{\mu}m$ 파장의 레이저론 입력단에 조사하였다. 결과적으로 저굴절률 차이 SiON 광도파로를 제작하였으며, 출력단에서 single-mode 형상을 확인하였다.

실리카 광도파로용 SiON 후막 특성에서 RF Power와 $SiH_4$/($N_2$O+$N_2$) Ratio가 미치는 영향 (The Effect of RF Power and $SiH_4$/($N_2$O+$N_2$) Ratio in Properties of SiON Thick Film for Silica Optical Waveguide)

  • 김용탁;조성민;서용곤;임영민;윤대호
    • 한국세라믹학회지
    • /
    • 제38권12호
    • /
    • pp.1150-1154
    • /
    • 2001
  • 플라즈마 화학기상증착(PECVD)법을 이용하여 실리카 광도파막의 코어로 이용되는 규소질산화막(SiON)을 Si 웨이퍼 위에 SiH$_4$,$N_2$O, $N_2$가스를 혼합하여 저온(32$0^{\circ}C$)에서 증착하였다. Prism coupler 측정을 통해 SiON 굴절률 1.4663~1.5496을 얻었으며, SiH$_4$/($N_2$O+$N_2$) 유량비와 rf power가 각각 0.33과 150W에서 8.67$mu extrm{m}$/h의 증착률을 나타내었다. 또한 SiH$_4$/($N_2$O+$N_2$) 유량비가 감소함에 따라 SiON막의 roughness는 41~6$\AA$까지 감소하였다.

  • PDF

고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정 시스템 개발 (Development of On-Line Partial Discharge Measuring System for Insulation Diagnosis of High-Voltage Motor Stator Windings)

  • 황돈하;강동식;신병철;이영진;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.481-486
    • /
    • 2006
  • In this paper, a new on-line high-voltage motor monitoring system is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). And this system displays magnitude and phase angle distribution of PD. Sensor, CC (Ceramic Coupler) is used for PD measurement. PD signals are continuously measured and digitized with a A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-232, 422, and TCP/IP. This helps more efficient operation and maintenance of the high-voltage motor.

  • PDF

PECVD법에 의해 증착된 SiO2 후막의 광학적 성질 및 구조적 분석 (Optical Properties and Structural Analysis of SiO2 Thick Films Deposited by Plasma Enhanced Chemical Vapor Deposition)

  • 조성민;김용탁;서용곤;윤형도;임영민;윤대호
    • 한국세라믹학회지
    • /
    • 제39권5호
    • /
    • pp.479-483
    • /
    • 2002
  • 저온($320^{\circ}$C)에서 $SiH_4$$N_2O$ 가스의 혼합을 통해 플라즈마화학기상증착(PECVD)법을 이용하여 실리카 광도파로의 클래딩막으로 사용되는 $SiO_2$ 후막을 제조하였으며, 공정변수로는 $N_2O/SiH_4$ 유량비와 RF power에 변화를 주었다. 증착된 시편은 $N_2$ 분위기의 열처리로에서 $1050{\circ}$에서 2시간동안 열처리하였다. $N_2O/SiH_4$ 유량비가 증가함에 따라 증착속도는 $9.4~2.9{\mu}m /h$까지 감소하였으며, RF power가 증가함에 따라 증착속도는 $4.7~6.9{\mu}m /h$까지 증가하였다. 두께 및 굴절률은 Prism Coupler를 이용하여 분석하였다. 화학적 성질 및 구조적 성질은 X-ray Photoelectron Spectroscopy(XPS)와 Fourier Transform-Infrared Spectroscopy(FT-IR)를 이용하여 분석하였으며, Scanning Electron Microscopy(SEM)를 이용하여 시편의 단면을 관찰하였다.

고전압회전기 고정자권선 운전중 부분방전진단시스템의 현장적용사례 연구 (A Case Study of On-line PD Measuring System on the Stator Winding for High Voltage Rotating Machine)

  • 오봉근;강동식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.109-109
    • /
    • 2010
  • On-line partial discharge(PD) diagnostic system is the most prominent systems to diagnose insulation condition for the high voltage rotating machines. Partial discharge measuring system(PDMS) series with ceramic coupler(PD detecting sensor) installed hydro generator and high voltage motor have been measured the PD data for many years. The trend of PD magnitude in the on-line PD system increased for some machines. These machines showed a same result in the conventional off-line PD test and PD magnitude decreased after stator winding insulation cleaning. This case study show that PDMS has been proved to be good results by comparing PD magnitude with on-line and off-line PD test and it is important to plan the maintenance project for the hydro generator stator winding because PD value was decreased after insulation cleaning.

  • PDF

분산 전구체를 이용한 Diarylide계 안료의 합성 및 분산거동 (Synthesis of Diarylide Pigments and Their Dispersion Behavior by Dispersion Precursors)

  • 김송혁;김재환;양석원;김대성;이근대;박성수
    • 공업화학
    • /
    • 제25권6호
    • /
    • pp.586-591
    • /
    • 2014
  • 본 연구에서는 높은 은폐력과 선명한 황색 색상을 나타내는 diarylide 화합물 안료를 제조하기 위하여 커플링 합성 공정에서 pH, 커플러 수용액의 온도, 분산 전구체의 종류, 분산 전구체의 첨가량, 결정화 온도가 시료의 물성에 미치는 영향을 고찰하였다. 시료들의 특성은 푸리에 적외선 분광기, UV-Vis 분광기, 입도분석기, 제타 포텐샬, turbiscan을 이용하여 비교 분석하였다. 커플링 합성 공정에서 분산 전구체를 도입하면, 분산성이 상대적으로 우수한 시료를 얻을 수 있었다.

고압 배전선로 전력선 통신 신호결합장치 개발 (Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line)

  • 이재조;박영진;오휘명;김관호;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권6호
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

전력기기 열화 진단을 위한 부분방전 모의 및 측정 알고리즘 개발연구 (Investigation of Simulation and Measuring Algorithm of Partial Discharge for Diagnosis of Electric Machinery Deterioration)

  • 장형택;곽선근;신판석;김창업;정교범
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.30-38
    • /
    • 2011
  • This paper proposes a new intelligent diagnosis equipment for the partial discharge, which keeps deteriorating the insulating materials inside electric machineries, ultimately leading to electrical breakdown. In order to simulate experimentally the partial discharge inside the electric machinery, the tip-to-plate, the sphere-to-plate, the sphere-to-sphere and the plate-to-plate electrodes are used respectively, of which the gaps are 1[mm], 3[mm] or 5[mm] and the applied voltages are 3[kV], 5[kV] or 7[kV]. Ceramic coupler sensor and FIR digital filter are used to measure the partial discharge and the artificial neural network is used for the deterioration diagnosis of the electric machinery. The microprocessor of PD diagnosis equipment is DSP (TMS320C6713) with FPGA (Cyclone II). The results of the real-time and on-line experiments performed with the developed equipment are also explained.