• Title/Summary/Keyword: Cephalometric measurements

Search Result 244, Processing Time 0.026 seconds

A Study on Reliability of Computerized Cephalometric Analysis System (두부 방사선 규격사진 컴퓨터 분석기의 신뢰도에 관한 연구)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.47-55
    • /
    • 1994
  • To investigate the reliability and reproducibility of the computerized cephalometric analysis system, se compared the differences of the 10 linear and 13 angular measurements by manual works and the use of computerized cephalometric analysis system. We obtained as follows : 1. There was not significant difference between maean values of 22 manual and computerized measurements. 2. There was not significant difference between mean differences of manual and computerized cephalometric analysis data taken by same examiner except facial depth, facial length and posterior facial height. 3. There was not significant difference between mean differences of two trials of the computerized cephalometric analysis data by same examiner in all measurements. 4. There was not significant difference between mean differences of the computerized cephalometric analysis data by two examiners except FMIA and IMPA. According to this result, we guess the use of computerized cephalometric analysis system is useful on diagnosis and treatment planning of othodontic patients.

  • PDF

A STUDY ON THE CEPHALOMETRIC CHANGES BY THE DISPLACEMENT OF THE MANDIBULAR CONDYLES (하악과두 전위로 인한 두부방사선계측의 변화에 관한 연구)

  • Yoo, Ki-Whan;Kook, Yoon-A;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.591-601
    • /
    • 1991
  • To determine the difference in cephalometric measurements between centric relation and centric occlusion, 60 patient-20 patients for each malocclusion group-were examined with the cephalograms in centric relation and in centric occlusion. The results are as follows: 1. There are differences in cephalometric measurements with the mandible in the two different position, and some measurements are statistically significant. 2. No clinically useful prediction may be made from cephalometric radiographs concerning the amount of mandibular deflection from centric relation to centric occlusion. 3. If, the large differences in the cephalometric measurements with the mandible in the two different position, the analysis with the cephalogram in centric occlusion is needed to be compensated with the other clinical approach.

  • PDF

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

A COMPARATIVE STUDY OF COMPUTED RADIOGRAPHIC CEPHALOMETRY AND CONVENTIONAL CEPHALOMETRY IN RELIABILITY OF HEAD FILM MEASUREMENTS (LANDMARKS IDENTIFICATION) (일반 측방 두부규격 방사선사진과 측방 추부규격 전산화 방사선사진에서의 계측점의 신뢰도에 대한 비교 연구)

  • Kim Hyung-Don;Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.99-106
    • /
    • 1997
  • The purpose of this study was to compare & to find out the variability of head film measurements (and marks identification) between Fuji computed radiographic cephalometry and conventional cephalometry. 28 Korean adults were selected. Lateral cephalometric FCR film and conventional cephalometric film of each subject was taken. Four investigators identified 24 cephalometric landmarks on lateral cephalometric FCR film and conventional cephalometric film. The comparable measurements between lateral cephalometric FCR film and conventional cephalometric film were statistically analysed. The results were as follows : 1. In FCR film & conventional film, coefficient of variation (C.V.) of 24 landmarks was taken horizonta1ly & vertically. There is no significant difference of rank order of landmarks in C.V. between two films. 2. In comparison of significant differences of landmarks variability between FCR film & conventional film, horizontal value of coefficient of variation, showed significant differences in four landmarks among twenty-four landmarks, but vertical value of coefficient of variation showed significant differences in sixteen landmarks among twenty-four landmarks. FCR film showed significantly less variability than conventional film in 17 subjects among 20(4+16) subjects that showed significant difference.

  • PDF

The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph (디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교)

  • Kim Mi-Ja;Huh Kyung-Hoe;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Lee Jin-Koo;Ahn Byoung-Keun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

The Treatment Change of PAR(Peer Assessment Rating) Index and Cephalometric Measurements in Class I Malocclusion Patients (제 I 급 부정교합 환자에서 치료전후 PAR지수와 두부방사선계측치의 변화)

  • Kim, Hyeon-Hye;Lee, Ky-Heon;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.277-284
    • /
    • 1999
  • The purpose of this study was to evaluate the relation between the treatment duration and cephalometric measurements and the PAR index in Class I malocclusion patients. In 100 Class I malocclusion patients, PAR score and cephalometric measurements were taken from study model and cephalometric radiographs and analyzed statistically. The results of this study were obtained as follows: 1. treatment duration was correlated with extraction and pre PAR index. 2. ANB, FMA, FMIA and IMPA exhibited positive correlation between pre PAR index and pretreatment cephalometric measurements. 3. $\underline{1}$ to FP exhibited positive correlation between post PAR index and posttreatment cephalometric measurements, and $\overline{1}$ to FP exhibited negative correlation. 4. $\underline{1}$ to SN, IIA and $\overline{1}$ to FP exhibited positive correlation between ${\%}\;PAR$ reduction and the change of cephalometric measurements and FMA FMIA, WITS and UL exhibited negative correlation. The results of this study indicate that PAR index taken from study model relate with items concerned with upper and lower incisors, and there are the tendency that pretreatment PAR index are larger in the patients with large Am value and hyperdivergent face.

  • PDF

Cephalometric Characterstics and their Relationship to Respiratory Disturbance Indices in Snorer and Patients with Obstructive Sleep Apnea (코골이와 폐쇄성 수면무호흡증 환자의 두부규격방사선사진 상의 특징 및 호흡장애지수와의 상관관계)

  • Choi, Jae-Kap;Choi, Jung-Mi;Ahn, Hyoung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.369-376
    • /
    • 2001
  • Objectives : The purposes of the study was to evaluate cephalometric characteristics in snorers and patients with obstructive sleep apnea (OSA) and to see any relationships between the cephalometric measurements and respiratory disturbance indices (RDI). Materials and Methods : Twelve snoring patients, 11 patients with OSA, and 10 normal subjects were included for the study. After taking a screening sleep study for a night to obtain RDI, $SaO_2$, and snoring index, a detailed cephalometric analysis was conducted to obtain SNA, SNB, SN-MP, IAS, MAS, SPAS, SAAS, Mn-H, and PNS-P. All the data were compared between groups. For a group including 12 snoring patients and 11 OSA patients, correlation coefficients were calculated between respiratory disturbance index and each item of cephalometric measurements. Results : The mandible and the maxilla are retropositioned. The oropharyngeal and hypopharyngeal airway is reduced in area and is a factor that could produce or enhance OSA symptoms. The hyoid bone is displaced inferiorly. The soft palate is significantly elongated. Conclusions : These data suggest that cephalometric evaluation could be useful to evaluate snoring and OSA patients, and to assist with the planning treatment for improvement of upper airway patency.

  • PDF

COMPARISONS OF MEASUREMENTS OBTAINED FROM LATERAL CEPHALOMETRIC RADIOGRAPHS AND DIGIGRAPHS OF DOLPHIN IMAGING SYSTEM (측모 두부 방사선사진과 컴퓨터 영상사진 (Dolphin Imaging System)의 계측치 에 관한 비교)

  • Park, Hae-Joon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.521-534
    • /
    • 1994
  • The purpose of this study was to compare the differences in measurements between cephalometric radiographs and digigraphs of Dolphin Imaging System. 26 Korean adult male and 24 adult female with normal occlusion were selected. For each subject lateral cephalogram was taken. Digitizing with Digigraph Work Station of Dolphin in System. was performed as well. 50 tracings and 50 digigraphs were analyzed with Yonsei, Ricketts, Burstone analyses. The comparable measurements between tracing group and digigraph group were statistically analyzed. The results were as follows: 1. 13 of 64 comparable measurements did not show any statistically significant difference (P>0.05) between tracing group and digigraph group. 2. Three of the measurements with FH plane as a reference plane did not show any statistically insignificant difference. All measurement with SN plane as a reference plane showed statistically significant difference(p<0.05). 3. The measurements which showhed no statistically significant difference were mostly short distance linear measurements while most of the angular measurements showed statistically significant difference(p<0.05).

  • PDF

Factors affecting smile esthetics in adults with different types of anterior overjet malocclusion

  • Cheng, Hsin-Chung;Cheng, Pei-Chin
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.31-38
    • /
    • 2017
  • Objective: This study aimed to quantitatively assess the relationship of smile esthetic variables with various types of malocclusion, and identify the cephalometric factors affecting smile measurements. Methods: This retrospective study included 106 patients who were treated with retention at the orthodontic department of Taipei Medical University Hospital. Hard-tissue variables were measured using lateral cephalographic tracings, and nine smile esthetic variables were measured using facial photographs. The patients were divided into three groups according to their overjet (< 0, 0-4, and > 4 mm). An analysis of variance was conducted to compare the pretreatment cephalometric variables and smile esthetic variables among the three groups. Multiple linear regression analysis was performed to identify the cephalometric factors affecting the smile measurements in each group. Results: Except the upper midline and buccal corridor ratio, all of the smile measurements differed significantly among the three groups before orthodontic treatment. Some of the smile characteristics were correlated with the cephalometric measurements in different types of malocclusion. The overjet was the major factor influencing the smile pattern in all three types of malocclusion. Conclusions: Smile characteristics differ between different types of malocclusion; the smile may be influenced by skeletal pattern, dental procumbency, or facial type. These findings indicate that establishment of an optimal horizontal anterior teeth relationship is the key to improving the smile characteristics in different types of malocclusion.

THE CLINICAL RELIABILITY AND EFFECTIVENESS OF THE POSTERO-ANTERIOR CEPHALOMETRIC VIEW, SUBMENTOVERTEX VIEW & PANORAMIC VIEW IN THE DIAGNOSIS OF THE FACIAL ASYMMETRY (안면 비대칭 환자 진단에 있어서 후전방두부 방사선사진과 이하두정 방사선사진 및 파노라마 방사선사진의 임상적 효용성)

  • Choi Eun-Young;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.427-437
    • /
    • 1994
  • Clinical examination, photometric evaluation, & radiographic analysis have been used to evaluate the asymmetry of the face. Commonly used skull radiographs to assess skeletal asymmetry include poatero-anterior cephalometries, submentovertex view, & panoramic view. The purpose of this study is the comparison of the reliance of the postero-anterior cephalometric view, submentovertex view, & panoramic view in the asymmetry evaluation. All measurements were performed on the each radiographs of 31 control group & 30 asymmetric group. The measurements are MSL(midsagittal plane)-Co, MSL-Go, MSL-Me, MSL-Al, MSL-Bl, Mn. Ramus Height(Co-Go), Mn. Body Length(Go-Me), and Total Mn. Length(Co-Me). The results were as follows: 1. The lack of either a right-sided or left-sided asymmetric dominant was found. 2. The postero-anterior cephalometric view & submentovertex view relatively agreed with each other in the result. The postero-anterior cephalometric view & submentovertex view had the clinical reliability & effectiveness in the diagnosis of the skeletal asymmetry(p<0.05). 3. The panoramic view showed more magnification compared to the other radiographs. In the vertical measurements the panoramic view had clinical reliability relatively(p<0.05). But we cannot rely on the horizontal measurements in the panoramic view(p>0.05).

  • PDF