• 제목/요약/키워드: Cephalogram

검색결과 188건 처리시간 0.026초

Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구 (Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms)

  • 권대근;민승기;전인철;팽준영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권2호
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

폐쇄성수면무호흡 의심환자에서 무호흡-저호흡 지수와 연관이 있는 두개골 계측 변수 : 예비연구 (Cephalometric Variables Significantly Associated with Apnea Hypopnea Index in Suspected Obstructive Sleep Apnea Patients : A Preliminary Study)

  • 박수영;황희영;김응엽;강승걸;김선태;박기형
    • 생물정신의학
    • /
    • 제22권1호
    • /
    • pp.14-19
    • /
    • 2015
  • Objectives The purpose of this study is to find the cephalometric variables which are significantly correlated with the apnea-hypopnea index (AHI) in suspected Korean obstructive sleep apnea (OSA) patients. Methods We examined lateral cephalogram and attended-full night laboratory polysomnography of the 40 participants who complained of OSA symptoms. The correlation analysis was conducted to find the cephalometric variables which are significantly correlated with the AHI. Results The correlation analysis showed that the higher AHI was associated with the longer distance between hyoid and mandibular plane (p = 0.023), the longer distance between C3 and hyoid (p = 0.014), the longer tongue length (p = 0.003), the larger inferior tongue area (p = 0.008), the larger anterior displacement of the hyoid bone (p = 0.024), the longer distance between posterior nasal spine and the tip of the soft palate (p = 0.021), and the larger cross-sectional area of soft palate (p = 0.001) of cephalogram in erect position. The higher AHI was correlated with the longer distance between hyoid and mandibular plane (p = 0.008), the longer tongue length (p = 0.037), the larger inferior tongue area (p = 0.013), the thicker uvula (p = 0.004), the longer distance between retrognathion and hyoid (p = 0.025), and larger cross-sectional area of soft palate (p = 0.001) of cephalogram in supine position. Conclusions The present preliminary results showed the candidate measurements of cephalogram which are significantly correlated with the AHI in suspected OSA.

Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

  • Radhakrishnan, Pillai Devu;Varma, Nilambur Kovilakam Sapna;Ajith, Vallikat Velath
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.93-97
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. Materials and Methods: The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measured using both a lateral cephalogram and a panoramic radiograph. In the lateral cephalograms, the gonial angle was measured at the point of intersection of the ramus plane and the mandibular plane. In the panoramic radiographs, the gonial angle was measured by drawing a line tangent to the lower border of the mandible and another line tangent to the distal border of the ascending ramus and the condyle on both sides. The data obtained from both radiographs were statistically compared. Results: No statistically significant difference was observed between the gonial angle measured using the lateral cephalograms and that determined using the panoramic radiographs. Further, there was no statistically significant difference in the measured gonial angle with respect to gender. The results also showed a statistically insignificant difference in the mean of the right and the left gonial angles measured using the panoramic radiographs. Conclusion: As the gonial angle measurements using panoramic radiographs and lateral cephalograms showed no statistically significant difference, panoramic radiography can be considered in orthodontics for measuring the gonial angle without any interference due to superimposed images.

두개안면골 형태에 따른 두부위치에 관한 두부방사선 계측학적 연구 (A CEPHALOMETRIC STUDY OF THE NATURAL HEAD POSITION ACCORDING TO CRANIOFACIAL MORPHOLOGY)

  • 김형준;유영규
    • 대한치과교정학회지
    • /
    • 제17권1호
    • /
    • pp.55-62
    • /
    • 1987
  • Diagnosis and treatment plans of patients are depended on cephalogram in most case. However, conventional cephalogram may change diagnosis because it ignores a conception of natural head position. The purpose of this study was to investigate the difference of head positions between conventional X-ray taking and x-ray taking in natural head position, and correlation between above results and craniofacial morphology, 60 male students in dental college, Yon sei Univ. were selected, and every cephalogram is studied by comparison of the change of head position. The results are as follows. 1. When taking X-ray by using conventional method, external auditary meatus FH was more tilted than ear rod FM by $2.1^{\circ}{\pm}1.8$ in forward and downward direction. 2. As facial form becomes concave, natural head position and head position, appeared in X-ray taking by using conventional method, become more similiar. 3. Change in head position had showed high correlations with facial form (N-A-Pog angle), and there was high significance to concave group when compared with average group, but significance to convex group was not found. 4. Multiple regression equation concerning change of head position was solved. ${\Delta}FH=24.5\;+\;0.31$ NAPog + 0.43 Prominence of Chin + 0.13 Facial length -0.32 Anterior facial height.

  • PDF

Benefits of lateral cephalogram during landmark identification on posteroanterior cephalograms

  • Hwang, Sel-Ae;Lee, Jae-Seo;Hwang, Hyeon-Shik;Lee, Kyung-Min
    • 대한치과교정학회지
    • /
    • 제49권1호
    • /
    • pp.32-40
    • /
    • 2019
  • Objective: Precise identification of landmarks on posteroanterior (PA) cephalograms is necessary when evaluating lateral problems such as facial asymmetry. The aim of the present study was to investigate whether the use of lateral (LA) cephalograms can reduce errors in landmark identification on PA cephalograms. Methods: Five examiners identified 16 landmarks (Cg, N, ANS, GT, Me, RO, Lo, FM, Z, Or, Zyg, Cd, NC, Ms, M, and Ag) on 32 PA cephalograms with and without LA cephalograms at the same time. The positions of the landmarks were recorded and saved in the horizontal and vertical direction. The mean errors and standard deviation of landmarks location according to the use of LA cephalograms were compared for each landmark. Results: Relatively small errors were found for ANS, Me, Ms, and Ag, while relatively large errors were found for N, GT, Z, Or, and Cd. No significant difference was found between the horizontal and vertical errors for Z and Or, while large vertical errors were found for N, GT, and Cd. The value of identification error was lower when the landmarks were identified using LA cephalograms. Statistically significant error reductions were found at N and Cd with LA cephalograms, especially in the vertical direction. Conclusions: The use of LA cephalograms during identification of landmarks on PA cephalograms could help reduce identification errors.

정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구 (Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram)

  • 황현식;은춘선;황정현;임회정
    • 대한치과교정학회지
    • /
    • 제35권4호
    • /
    • pp.251-261
    • /
    • 2005
  • 두부방사선규격사진은 작은 크기의 방사선원에서 방사상으로 방사선이 퍼져나감으로써 피사체의 확대와 왜곡이 불가피하다는 단점이 있다. 본 연구는 두 장의 방사선사진을 서로 직각으로 촬영한 후 방사선의 기하학적 성질을 이용하여 좌우 우각부간 폭경을 계산할 경우 실제 폭경의 산출이 가능한지 알아보고자 시행되었다. 성인 40명을 연구대상으로 하여 두부자세재현기를 이용하여 측모두부방사선사진과 정모두부방사선사진을 서로 직각으로 촬영한 후 측모사진과 정모사진에서의 확대율을 이용하여 실제 우각부 폭경을 산출한 다음 계측치 및 산출치를 3차원 CT영상에서의 계측치와 각각 비교 분석하였다. 연구결과 정모두부방사선사진에서 우각부 폭경은 작게는 7.92mm 크게는 11.31mm까지. 평균 9.10mm의 확대를 보였다. 측모 및 정모두부방사선사진을 이용하여 얻은 우각부 폭경 보정치를 3차원 CT영상에서 얻은 기준치와 비교한 결과 평균 0.14mm의 작은 오차를 보였으며 통계적으로 유의한 차이를 보이지 않아 측모 및 정모두부방사선사진 촬영 시 두부자세재현기를 이용하여 서로 직각으로 촬영할 경우 실제 우각부 폭경을 계산을 통해 산출할 수 있음을 보여주었다. 한편 이부편위량과 보정오차는 통계적으로 유의한 상관성을 보이지 않아 안면비대칭이 심한 경우에도 본 보정 방법이 유용하게 사용될 수 있음을 보여 주었다.

Cone-Beam Computed Tomogram (CBCT)과 Adjusted 2D lateral cephalogram의 계측점 차이에 관한 비교 연구 (Comparison of landmark positions between Cone-Beam Computed Tomogram (CBCT) and Adjusted 2D lateral cephalogram)

  • 손수정;전윤식;김민지
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.222-232
    • /
    • 2014
  • 목적: 본 연구에서는 CBCT (Cone-Beam Computed Tomogram)와 100%로 확대율을 보정한 조절된 측모 두부 방사선 규격 계측 사진(Adjusted 2D Lateral Cephalogram; 이하 Adj-Ceph)의 좌표값을 비교하여 차이가 있는 계측점들의 항목을 분석하여 기존의 2D 분석법을 CBCT 분석에 적용할 수 있는지 여부를 평가해보고자 하였다. 재료 및 방법: 성인 환자 50명의 CBCT 자료 50개와, 동일 환자의 측모 두부 방사선 규격사진을 100% 확대율로 보정한 자료(Adj-Ceph) 50개를 대상으로 하여, 수평축과 수직축의 좌표를 비교하였다. 계측점들의 위치와 좌우 중첩 여부에 따라 두개골 전방에 위치한 점들(group A), 두개 중후방에 위치한 점들(group B), 좌우 양측성 점들(group C), 치아부위 계측점들(group D) 네 그룹으로 나누어 분석 하였고, 좌표값에 유의한 차이가 있는지 분석하기 위하여 paired t-test를 시행하였다. 결과: 수평축(Y축)에서는 Group B (S, Ar, Ba, PNS), Group C (Po, Or, Hinge axis, Go), Group D (U1RP, U6CP, L6CP) 등 11개의 계측점에서 유의한 차이가 있었다. 수직축(Z축)에서는 전체 계측점에서 유의한 차이가 있었다(P<.01). 좌표값의 차이 분석 결과 수평축에서는 13개의 계측점에서 1 mm 이상의 유의한 차이가 있었다. 수직축에서는 Group B의 Sella를 제외한 전체 계측점에서 1 mm 이상의 유의한 차이가 있었다. 결론: CBCT 분석 시에는 기존의 측모두부방사선 규격사진의 분석법을 그대로 사용하기에는 어려움이 있다. 3D 분석법, 또는 수평축에서 13개의 계측점들이 보정되고, 수칙축 19개가 보정된 수정된 새로운 2D 분석법이 사용되어야 한다.

Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가 (The reliability of the cephalogram generated from cone-beam CT)

  • 강지영;김광원;임성훈
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.391-399
    • /
    • 2007
  • 최근 computed tomography (CT) 데이터로부터 실제 두부계측방사선사진 촬영기에서 촬영한 사진과 동일한 확대율을 갖는 두부계측방사선사진을 형성할 수 있는 기능을 갖춘 소프트웨어(Accurex, CyberMed, Seoul, Korea)가 소개되었다. 이에 본 연구에서는 cone-beam CT (이하 CBCT) 데이터로부터 이 소프트웨어를 이용하여 제작된 측모 두부계측방사선사진과 기존의 두부계측방사선사진촬영기로 촬영된 측모 두부계측방사선사진에서 각각 두부계측방사선사진 분석을 시행하여 그 차이를 비교함으로써 소프트웨어를 통해 CBCT로부터 제작된 측모 두부계측방사선사진의 활용 가능성을 평가하고자 하였다. 20명의 교정 환자를 대상으로 CBCT와 측모 두부계측방사선사진을 동시에 촬영하였다. CBCT로부터 제작된 측모 두부계측방사선사진과 기존 방식의 측모 두부계측방사선사진에서 두부계측 방사선사진 분석을 시행한 후 두 사진의 계측치의 차이를 paired t-test로 검정하였다. 23개의 계측치들 중, 20개 항목에서는 통계학적으로 유의한 차이가 관찰되지 않았으나, U1-FH, Mx6 to PTV, Maxillomandibular difference의 항목에서는 유의한 차이가 나타났다 이러한 차이는 CBCT로부터 형성된 측모 두부계측방사선사진의 해상도가 낮아 일부 해부학적 지표를 확인하기 어렵기 때문이며, 임상에서 CBCT로부터 제작된 측모 두부계측방사선사진을 porion, PTV, condylion과 같은 일부 해부학적 지표를 이용하지 않는 SNA, SNB, U1 to SN, IMPA, interincisal angle 등 흔히 사용되는 간단한 측모 두부계측방사선사진 계측에 활용 가능할 것이다.선 병용요법은 절제 불가능한 원발성 간암의 증상호전 및 국소적 치료에 효과가 있는 것으로 생각되며 생존율 및 부작용 등에 관해서는 앞으로 연구가 더 진행되어야 할 것으로 생각된다.용 선형가속기의 전자선 방출구에 장착된 산란판과 조사면을 조정하는 cone에 의하여 발생되는 저 에너지 산란전자선이 alanine dosimeter에 측정된 것으로서 에너지가 증가될수록 오염 정도가 증가되었다. 본 실험을 통하여 지금까지 고에너지 전자선량계측에서 전리상에 의한 전기량 측정과 산란선이 없는 단일 에너지로만 간주하여 계산하였던 전자선 흡수선량 측정방법을 직접 흡수선량 측정이 가능한 Alanine/ESR dosimetry로서 교정하는 것이 바람직하다고 생각한다.$6\%$, 수술이 필요하였던 환자는 $1\%$로 합병증의 증가 없이 A점에 8900cGy, 직장에 7300cGy정도의 국소치료가 가능함을 보여 주었으나 생존율에 대한 추후 분석이 따라야 할 것으로 사료된다.보면 6,000rad이하에서 20/63$(34.9\%)$의 실패율에 비하여 6,000rad이상일 때는 10/49$(20.4\%)$의 실패율이었다. 연령 벨로는 $40\~49$세에서 실패율(14/41 $24.1\%$)이 많았다. 본 성적으로 보아서 생존율은 여러 저자들과 큰 차이가 없음을 알 수 있었고 A점 선량은 8,000rad 이상, B점은 6,000rad이상이 조사되어야 적정선량이 됨을 시사해 주고 있다.\%$가 대부분이 하루 세끼 식사를 규칙적으로 하고 있었으며 식사속도는 허겁지겁 빨리 섭취하는 경우가 남자는 $31.0\%$,