• 제목/요약/키워드: Central hole

검색결과 159건 처리시간 0.028초

Punching Fracture Experiments and Simulations of Unstiffened and Stiffened Panels for Ships and Offshore Structures

  • Park, Sung-Ju;Choung, Joonmo
    • 한국해양공학회지
    • /
    • 제34권3호
    • /
    • pp.155-166
    • /
    • 2020
  • Ductile fracture prediction is critical for the reasonable damage extent assessment of ships and offshore structures subjected to accidental loads, such as ship collisions and groundings. A fracture model combining the Hosford-Coulomb ductile fracture model with the domain of solid-to-shell equivalence model (HC-SDDE), was used in fracture simulations based on shell elements for the punching fracture experiments of unstiffened and stiffened panels. The flow stress and ductile fracture characteristics of JIS G3131 SPHC steel were identified through tension tests for flat bar, notched tension bar, central hole tension bar, plane strain tension bar, and pure shear bar specimens. Punching fracture tests for unstiffened and stiffened panels are conducted to validate the presented HC-DSSE model. The calibrated fracture model is implemented in a user-defined material subroutine. The force-indentation curves and final damage extents obtained from the simulations are compared with experimental results. The HC-DSSE fracture model provides reasonable estimations in terms of force-indentation paths and residual damage extents.

Flavobacterium columnare / Myxobolus tilapiae Concurrent Infection in the Earthen Pond Reared Nile Tilapia (Oreochromis niloticus) during the Early Summer

  • Eissa, Alaa E.;Zaki, Manal M.;Aziz, A. Abdel
    • Interdisciplinary Bio Central
    • /
    • 제2권2호
    • /
    • pp.5.1-5.9
    • /
    • 2010
  • Flavobacterium columnare (F. columnare), the dermotropic Gram negative yellow pigmented bacteria was isolated from different sites of skin ulcerations in the Nile tilapia (Oreochromis niloticus) and Nile catfish (Clarias gariepinus) collected from an earthen pond located at an aquaculture station in Sharkiya Province, Lower Egypt during an acute episode of mass kills during the early summer of 2009. An acute infection with F. columnare was behind the emergent event of mass mortalities among both populations. Many of the Nile tilapias exhibited typical signs of hole - in- the head like lesions from which F. columnare together with the myxosporean spore, Myxobolus tilapiae (M. tilapiae) were retrieved. Most of the cohabitating infected Nile catfishes exhibited severe form of saddle back like ulcer. The identities of the retrieved isolates were confirmed using morphological, biochemical and molecular tools. The research lead us to conclude that the two diverse etiological agents (F. columnare and M. tilapiae) under the triggering effect of the abrupt change in the water quality measures (abrupt rise in the water temperature, ammonia, pH, sharp decrease in dissolved oxygen) have synergized together to induce the above mentioned pathology with the consequent reemergence of fish mass mortalities.

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권3호
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.

공액근사개념과 Loubignac의 반복계산법을 이용한 국부응력장 개선에 대한 연구 (A study on the improvement of the local stress field using the theory of conjugate approximations and loubignac's iterative method)

  • 송기남
    • 대한기계학회논문집A
    • /
    • 제21권10호
    • /
    • pp.1598-1608
    • /
    • 1997
  • Based on the application of te theory of conjugate approximations and the Loubignac's iterative method in a local region, a method to improve the stress filed in a displacement-formulated finite element solution has been proposed. The validity of the proposed method has been tested through two examples : a thick cylinder under internal pressure loading and an infinite plate with a central circular hole subjected to uniaxial tension. As a result of analysis of the examples, it was found that the stress field obtained for the local region model by the proposed method approximates well for the whole domain model. In addition, it was found that because of a significant decrease in the computing time to obtain the improved stress field, the proposed method is efficient and useful for the detailed stress analysis in local regions.

재 사용된 IPS-empress ingot의 pressing accuracy에 관한 연구 (A STUDY ON THE PRESSING ACCURACY OF THE REUSED IPS-EMPERESS INGOT)

  • 송병권;박현배;오상천;진태호
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.357-364
    • /
    • 1997
  • IPS-empress system is one of widely used all ceramic system. The purpose of this study was to determine the pressing accuracy of reused IPS%Empress ingot. 10 specimens were made using new ingot first, and using the rests of the specimen the another group of specimens were made next. finally, the third group of specimens were made with same procedure mentioned above. The results obtained in this study were as follows ; 1. The pressing accuracy of the first group of specimen was 96.1%, that of the second group was 95.4%, and that of the third group was 95.4%. There was no statistical significance among them, that is, the reuse of the IPS-Empress ingot did not influence on the pressing accuracy. 2. the common site of the defect in pressed ingot was central area at the margin opposite of sprue hole.

  • PDF

증발디젤분무의 공간적 구조해석에 관한 기초 연구 (Basic Study on the Spatial Structure Analysis of the Evaporative Diesel Spray)

  • 염정국
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.5-12
    • /
    • 2010
  • The purpose of this study is to analyze heterogeneous distribution of branch-like structure at downstream region of inner spray. The previous many studies about diesel spray structure have yet stayed in the analysis of 2-D structure, and there are very few of informations which are concerned with 3-D analysis of the structure. The heterogeneous distribution of droplets in inner spray affects the mixture formation of diesel spray, and also the combustion characteristics of the diesel engines. Therefore, in order to investigate 3-D structure of evaporative spray the laser beam of 2-D plane was used in this study. Liquid fuel was injected from a single-hole nozzle (l/d=5) into a constant-volume vessel under high pressure and temperature in order to visualize the spray phenomena. The incident laser beam was offset on the central axis. From the images analysis taken by offset of laser beam, we examine formation mechanism of heterogeneous distribution by vortex flow at the downstream of the diesel spray. As the experimental results, the branch-like structure formed heterogeneous distribution of the droplets consists of high concentration of vapor phase in the periphery of droplets and spray tip of branch-like structure. Also the 3-D spatial structure of the evaporative diesel spray can be verified by images obtained from 2-D measurement methods.

Needle 코팅을 이용한 미세 PEDOT:PSS 스트라이프 제작 (Fabrication of Fine PEDOT:PSS Stripes Using Needle Coating)

  • 이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제18권3호
    • /
    • pp.100-104
    • /
    • 2019
  • We have investigated the feasibility of fabricating fine stripes using needle coating for potential applications in solution-processed organic light-emitting diodes (OLEDs). To this end, we have employed an aqueous poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) solution that has been widely used as a hole injection layer (HIL) of OLEDs and performed needle coatings by varying the process parameters such as the coating gap and coating speed. As expected, the stripe width is reduced with increasing coating speed. However, the central thickness of the stripe is rather increased as the coating speed increases, which is different from other coating processes such as slot-die and blade coatings. It is due to the fact that the meniscus formed between the needle tip and the substrate varies depending sensitively on the coating speed. It is also found that the stripe width and thickness are reduced with increasing coating gap. To demonstrate its applicability to OLEDs, we have fabricated a red OLED stripe and obtained light emission with the width of about 90㎛.

돌극 관통형 서치코일을 이용한 토로이달 스위치드 릴럭턴스 모터의 회전자 위치 검출 (Rotor Position Detection of a Toroidal Switched Reluctance Motor Using Interior Central Pole Search Coils)

  • 양형열;임영철
    • 전력전자학회논문지
    • /
    • 제9권5호
    • /
    • pp.448-456
    • /
    • 2004
  • 본 논문에서는 스위치드 릴럭턴스 모터의 새로운 회전자 위치 검출법을 제안한다. 기존의 위치센서의 약점을 보완하기 위해 위치 검출 방법의 저 비용과 강인성에 초점을 두고, 시변 쇄교자속에 의해 TSRM(Toroidal Switched Reluctance Motor) 돌극의 홈에 장착된 서치코일에 유기되는 전압 파형을 이용하여 위치 검출을 시도하였다. 회전자의 위치정보를 포함하고 있는 서치코일에서 유기되는 전압 파형을 이용해 회전자의 특정위치를 검출하고 적절한 상을 여자시킴으로써 SRM을 구동할 수 있게 된다. 실험을 통하여 서치코일만을 이용하여 토로이달 SRM을 구동시킨 결과와 엔코더를 사용하여 구동시킨 결과와 비교함으로써 본 논문에서 제시한 방법의 타당성을 검증하였다.

경복궁(景福宮) 근정문(勤政門) 상량문(上樑門) (The Kunjung-mun Sangryangmun of Kyunbok-koong Palace)

  • 서병패
    • 헤리티지:역사와 과학
    • /
    • 제34권
    • /
    • pp.196-209
    • /
    • 2001
  • Kunjung-mun Gate the only existing multi-level palace gate from the Chosun Dynasty, is the main fate of Kungjung-jun, the central building of Kyungbok-koong Palace. Sangryangmun(a written record of the construction of the ridge beam) of Kunjung-mun Gate was discovered in a hole under its main beam during the renovation project on September 19th, 2000. At the time of discovery, Sangryangmun was found in its original state as a rolled up scroll. On a clould-patterned, red silk cloth, 78 cm in width and 1200 cm in length, each of all 92 lines of the Kunjung-mun Sangryangmun is comprised of either 7 or 11 brush-written, ornamental "Seal" characters. With an exception of its discoloration, the material is considered well preserved. After its discovery, the National Institute of Cultural Properties stored the document in an airtight container for a permanent preservation. In accordance to the Royal Command at the time, the Kunjung-mun Sangryangmun was composed by Kim Byungi, then written by Lee Donsang on January 19th 1867. This document records the meaning and the process of the repair effort of Kunjung-mun Gate includes the wish for peace and longevity of the Chosun Kingdom and its people.

An observed link between AGN Eddington ratio and [NII] λ6583/Hα at 0.6

  • Oh, Kyuseok;Ueda, Yoshihiro;Akiyama, Masayuki;Suh, Hyewon;Koss, Michael;Mushotzky, Richard;Hasinger, Guenther;Kashino, Daichi;Silverman, John
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.36.1-36.1
    • /
    • 2019
  • We present the observed relationship between Eddington ratio (${\lambda}Edd$) and optical narrow-emission-line ratio ([NII] ${\lambda}6583/H{\alpha}$) of X-ray-selected unobscured active galactic nuclei (AGN) at 0.6 < z < 1.7 using 27 near-infrared spectra from the Fiber Multi-Object Spectrograph mounted on the Subaru telescope along with 26 additional sources from the literature. We show that the ${\lambda}Edd$ and [NII] ${\lambda}6583/H{\alpha}$ ratio at 0.6 < z < 1.7 exhibits a similar distribution of ${\lambda}Edd$-[NII] ${\lambda}6583/H{\alpha}$ anti-correlation that has been found for local ( = 0.036), hard X-ray selected AGN. The observed anti-correlation suggests that [N II] ${\lambda}6583/H{\alpha}$ optical narrow-line ratio in the AGN host galaxy may carry important information about the accretion state of the central supermassive black hole, suggesting the observational hint of consistent relationship from local to z ~ 1.7. Further study is necessary to determine whether the ${\lambda}Edd$-[N II] ${\lambda}6583/H{\alpha}$ correlation in high-redshift still holds at ${\log}{\lambda}Edd$ < -2 compared to local AGN.

  • PDF