• Title/Summary/Keyword: Central control system

Search Result 1,001, Processing Time 0.03 seconds

A Study on the Design and Performance Evaluation Technology of Fieldbus Pneumatic Solenoid Valve/Sensor System (필드버스 공압 솔레노이드 밸브/센서시스템 설계 및 성능평가 특성해석)

  • Kim, D.S.;Hong, C.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.865-870
    • /
    • 2001
  • For pneumatic system control, we need a data transmission system with high speed and high reliability or information interchange between main computer and solenoid valves and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid valves. In addition we developed a communication protocol for construction of RS-485 based multidrop network, and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. The field test results show that, even under high noise environment, the data transmission of 375Kbps rate is possible up to 1,000m without using repeater. In addition, the system developed in this research is proved to be used easily for extension of a communication network because of its module structure.

  • PDF

A Study on the Energy Saving Method by controlling Capacity of Sea Water Pump in Central Cooling System for Vessel (선박용 중앙냉각시스템의 해수 펌프 용량조절에 따른 에너지 절감 기법에 관한 연구)

  • Lee, Ji-Young;Yoo, Heui-Han;Kim, Yun-Hyung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.592-598
    • /
    • 2007
  • The fuel charge is getting higher in navigation cost. Therefore, shipowners try to find the method for reducing oil consumption. ESS(Energy Saving System) is one of he method. ESS is the system consisted with two inverters, ESS control unit and monitoring system. Two inverters control two main sea water cooling pumps. In the ESS control Unit, the control algorithm finds optimized point to decrease a power consumption of main sea water cooling pumps. Monitoring system observes ESS not to work improperly. ESS is experimented in the laboratory with real condition and analyzed in every view. After experiment, the result of the experiment shows that the control algorithm works correctly and safely. ESS has a plan to be operated in the ship soon. In that case, additional devices are needed to connect ESS with cooling system of the vessel. So the development of addition device is needed and being studied.

Memory of Pain and Preemptive Analgesia (통증의 기억과 선행진통)

  • Song, Sun-Ok
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.12-20
    • /
    • 2000
  • The memory of pain can be more damaging than its initial experience. Several factors arc related the directions of pain memory: current pain intensity, emotion, expectation of pain, and peak intensity of previous pain. The possible mechanisms behind the memory of pain are neuroplastic changes of nervous system via peripheral and central sensitization. Peripheral sensitization is induced by neurohumoral alterations at the site of injury and nearby. Biochemicals such as K+, prostaglandins, bradykinin, substance P, histamine and serotonin, increase transduction and produce continuous nociceptive input. Central sensitization takes place within the dorsal horn of spinal cord and amplifies the nociceptive input from the periphery. The mechanisms of central sensitization involve a variety of transmitters and postsynaptic mechanisms resulting from the activations of NMDA receptors by glutamate. and activation of NK-1 tachykinnin receptors by substance-P and neurokinnin. The clinical result of peripheral and central sensitization is hyperalgesia, allodynia, spontaneous pain, referred pain, or sympathetically maintained pain. These persistent sensory responses to noxious stimuli arc a form of memory. The hypothesis of preemptive analgesia is that analgesia administered before the painful stimulus will prevent or reduce subsequent pain and analgesic requirements in comparison to the identical analgesic intervention administered after the painful stimulus, by preventing or reducing the memory of pain in the nervous system. Conventionally, pain management was initiated following noxious stimuli such as surgery. More recently, however many have endorsed preemptive analgesia initiated before surgery. Treatments to control postsurgical pain are often best started before injury activates peripheral nociceptors and triggers central sensitization. Such preemption is not achieved solely by regional anesthesia and drug therapy but also requires behavioral interventions to decrease anxiety or stress. Although the benefit of preemptive analgesia may not be obvious in every circumstance, and in many cases may not sufficient to abolish central sensitization, it is an appropriate and human goal of clinical practice.

  • PDF

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

The Effect of Eye Movement on Balance Improvement by Plegia Side of Adult Hemiplegic Patient (안구운동이 성인 편마비 환자의 마비측에 따른 균형증진에 미치는 영향)

  • Koo Bong-Oh;Bae Sung-Soo;Kim Han-Soo;Lee Dong-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.1-19
    • /
    • 2002
  • The purpose of this study is to identify influence that eye movement have an effect on postural control and balance performance by plegia side of the impaired patients of central nervous system. Subjects are patients with the impairment of central nervous system and experimental and control groups are forty people and thirty people seperatively, Total subjects were selected to seventy persons, but twelve persons of experimental group quit during the experimental periods and eight persons of control group did not measure after exercise. Therefore, twenty eight persons of experimental group and twenty two persons of control group were selected in this study and experimental group peformed eye movement for eight weeks according to the exercise program of this study. The measurement of dependent variable is right static balance, left static balance, bilateral static balance, and bilateral dynamic balance before exercise and after eighth week of exercise, examiner again measured and analyzed the results. The results were as follows: 1. As the result of comparing balance performance ability after test of the experimental and control group with right hemiplegia and control group, all of static balance performance ability of right side (p < 0.01), static balance performance ability of left side (p < 0.01), static balance performance ability of bilateral side(p < 0.01), dynamic balance performance ability of bilateral side(p < 0.05) of experimental group were statistically greater improved than those of the control group. 2. As the result of comparing balance performance ability after test of the experimental and control group with left hemiplegia and control group, all of static balance performance ability of right side (p < 0.01), static balance performance ability of left side (p < 0.01), static balance performance ability of bilateral side(p < 0.05), dynamic balance performance ability of bilateral side(p < 0.05) of experimental group were statistically greater improved than those of the control group.

  • PDF

The evaluation of FAT for Master Control System of PFCS in ITER Coil Power Supply System (ITER 초전도코일 전력공급장치의 PFCS Master Control System 시험 평가)

  • Shin, H.K.;Oh, J.S.;Lee, D.B.
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.109-110
    • /
    • 2018
  • ITER 토카막의 초전도코일에 전원을 공급하는 Plant는 CCPS (Correction Coil Power Supply System), TFPS(Toroidal Field Power Supply System), PFCS(Poloidal Field & Central Solenoid)으로 구성되어 있다. 각 Plant의 AC/DC 컨버터는 초전도 코일에 막대한 전류를 흘려 토카막 내에서 1억도에 달하는 열과 전자장의 압력으로 플라즈마상태의 수소를 결합시켜 핵융합에 도달하도록 한다. MCS(Master Control System)은 플라즈마가 핵융합을 잘 구현할 수 있도록 초전도 코일에 공급하는 전원을 총괄적으로 제어한다. 특히 PFCS MCS는 토카막 장치에서 다른 Plant와의 Interface가 복잡하여 설계 및 제작에 어려움이 많다. 본 논문에서는 PFCS MCS가 ITER의 설계요건과 국제기술기준에 맞게 설계하고, 제작하였는지를 확인하기 위해 공장에서 최종 검사하는 FAT(Factory Acceptance Test) 절차를 소개하고 여러 가지 시험을 통하여 평가한 내용을 보이고자 한다.

  • PDF

Validation on the Analytical Method of Ginsenosides in Red Ginseng

  • Cho B. G.;Nho K. B.;Shon H. J.;Choi K. J.;Lee S. K.;Kim S. C;Ko S. R.;Xie P. S.;Yan Y. Z.;Yang J. W.
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.491-501
    • /
    • 2002
  • A cross-examination between KT&G Central Research Institute and Guangzhou Institute for Drug Control was carried out in order to select optimum conditions for extraction, separation and determination of ginsenosides in red ginseng and to propose a better method for the quantitative analysis of ginsenosides. The optimum extraction conditions of ginsenosides from red ginseng were as follows: the extraction solvent, $70\%$ methanol; the extraction temperature, $100^{\circ}C;$ the extraction time, 1 hour for once; and the repetition of extraction, twice. The optimum separation conditions of ginsenosides on the SepPak $C_{18}$ cartridge were as follows: the loaded amount, 0.4 g of methanol extract; the washing solvents, distilled water of 25 ml at first and then $30\%$ methanol of 25 ml; the elution solvent, $90\%$ methanol of 5 ml. The optimum HPLC conditions for the determination of ginsenosides were as follows: column, Lichrosorb $NH_2(25{\times}0.4cm,$ 5${\mu}m$, Merck Co.); mobile phase, a mixture of acetonitrile/water/isopropanol (80/5/15) and acetonitrile/water/isopropanol (80/20/15) with gradient system; and the detector, ELSD. On the basis of the optimum conditions a method for the quantitative analysis of ginsenosides were proposed and another cross-examination was carried out for the validation of the selected analytical method conditions. The coefficient of variances (CVs) on the contents of ginsenoside-$Rg_{1}$, -Re and $-Rb_1$ were lower than $3\%$ and the recovery rates of ginsenosides were $89.4\~95.7\%,$ which suggests that the above extraction and separation conditions may be reproducible and reasonable. For the selected HPLC/ELSD conditions, the CVs on the detector responses of ginsenoside-Rg, -Re and $-Rb_1$) were also lower than $3\%$, the regression coefficients for the calibration curves of ginsenosides were higher than 0.99 and two adjacent ginsenoside peaks were well separated, which suggests that the above HPLC/ELSD conditions may be good enough for the determination of ginsenosides.

  • PDF

A Study on the Distributed Control System and Application (분산제어시스템의 구축과 응용사례에 관한 연구)

  • 윤형득;신현식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.552-555
    • /
    • 2001
  • From the dissertation which it sees micro it is strong with the technical development which the computer and communication field is quick and efficiency improvement and control LAN (Local Area Network) this utility anger becomes with the pliability regarding a system construction to come to be high, central processing unit (CPU) function it separates especially and the LAN communication railway line (Data way) it uses and the controller royal tomb of process disperses, the information control and watch and operation fabrication function composes an anger making whole system intensively development background and application process and the right season of the dispersion control system which plans a reliability improvement, war potential and environment, possibility control, From industrial site of the petrochemistry back application and it investigated the dispersion control system which is applied to observe in many sidedness and until course of development of report hereafter dispersion control system it tried.

  • PDF

FPGA-based Centralized Controller for Multiple PV Generators Tied to the DC Bus

  • Ahmed, Ashraf;Ganeshkumar, Pradeep;Park, Joung-Hu;Lee, Hojin
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.733-741
    • /
    • 2014
  • The integration of photovoltaic (PV) energy sources into DC grid has gained considerable attention because of its enhanced conversion efficiency with reduced number of power conversion stages. During the integration process, a local control unit is normally included with every power conversion stage of the PV source to accomplish the process of maximum power point tracking. A centralized monitoring and supervisory control unit is required for monitoring, power management, and protection of the entire system. Therefore, we propose a field-programmable gate array (FPGA) based centralized control unit that integrates all local controllers with the centralized monitoring unit. The main focus of this study is on the process of integrating many local control units into a single central unit. In this paper, we present design and optimization procedures for the hardware implementation of FPGA architecture. Furthermore, we propose a transient analysis and control design methodology with consideration of the nonlinear characteristics of the PV source. Hardware experiment results verify the efficiency of the central control unit and controller design.

Formal Verification of PLC Program Safety in Manufacturing Automation System (생산자동화시스템 PLC 제어프로그램의 안전성 정형검증에 관한 연구)

  • Park, Chang Mok
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.179-192
    • /
    • 2015
  • In an automated industry PLC plays a central role to control the automation system. Therefore, fault free operation of PLC controlled automation system is essential in order to maximize a firm's productivity. A prior test of control system is a practical way to check fault operations, but it is a time consuming job and can not check all possible fault operation. A formal verification of PLC program could be a best way to check all possible fault situation. Tracing the history of the study on formal verification, we found three problems, the first is that a formal representation of PLC control system is incomplete, the second is a state explosion problem and the third is that the verification result is difficult to use for the correction of control program. In this paper, we propose a transformation method to reproduce the control system correctly in formal model and efficient procedure to verify and correct the control program using verification result. To demonstrate the proposed method, we provided a suitable case study of an automation system.