• Title/Summary/Keyword: Central Building

Search Result 691, Processing Time 0.03 seconds

MEASURING AND COMPARING PROFIT PATTERNS OF TRADITIONAL CONSTRUCTION COMPANIES EXTENDING TO HIGH-TECH CONSTRUCTION

  • Jieh-Haur Chen;Chung-Fah Huang;S. C. Hsu
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.360-365
    • /
    • 2005
  • The need of constructing high-tech facilities is one of the important issues concerning the competitiveness by the high-tech companies. It, simultaneously, offers a magnificent opportunity for construction participants. Nevertheless, the high-tech construction is experience-based, resulting in little related construction knowledge that has been statistically analyzed and documented. This study measures and confers with the profit patterns causing the disparity between the traditional and high-tech construction. The database was the result of collecting detailed information of 65 construction projects from eight construction companies, including detailed records of over 20 main construction operations in each project. All of these were performed during the recent 10 years and encompassed in the project types of the high-tech construction, residential building, and commercial building. Rendering suggestions regarding profit management and expecting to economize cost of learning from inexperience while extending to the high-tech construction were both presented.

  • PDF

Performance of headed FRP bar reinforced concrete Beam-Column Joint

  • Md. Muslim Ansari;Ajay Chourasia
    • Structural Engineering and Mechanics
    • /
    • v.90 no.1
    • /
    • pp.71-81
    • /
    • 2024
  • Fiber Reinforced Polymer (FRP) bars have now been widely adopted as an alternative to traditional steel reinforcements in infrastructure and civil industries worldwide due variety of merits. This paper presents a numerical methodology to investigate FRP bar-reinforced beam-column joint behavior under quasi-static loading. The proposed numerical model is validated with test results considering load-deflection behavior, damage pattern at beam-column joint, and strain variation in reinforcements, wherein the results are in agreement. The numerical model is subsequently employed for parametric investigation to enhance the end-span beam-column joint performance using different joint reinforcement systems. To reduce the manufacturing issue of bend in the FRP bar, the headed FRP bar is employed in a beam-column joint, and performance was investigated at different column axial loads. Headed bar-reinforced beam-column joints show better performance as compared to beam-column joints having an L-bar in terms of concrete damage, load-carrying capacity, and joint shear strength. The applicability and efficiency of FRP bars at different story heights have also been investigated with varying column axial loads.

Survey Study of Optimal Cooling Equipment Capacity of the Large Hospitals in Busan City (부산지역 대형병원 냉방장비의 용량설정 실태조사)

  • Lee, Ji-Weon;Chin, Kyung-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.105-110
    • /
    • 2014
  • The basic factors determining the amount of energy used in hospital buildings are weather conditions and building factors. But the real energy consumer is central plant equipment such as boilers and chillers that produce thermal energy for heating and cooling. Inaccurate decision of the primary equipment's size can cause a high initial-cost, an excessive equipment space, a wasted energy by low operation-efficiency and shortening of the machine's life. In this reason, the decision of optimal size for central plant equipment is very important. There are several factors for the decision such as an operation factor, a factor (equipment factor), piping losses and a simultaneous usage factor applied in the sizing process except a basic cooling load. But there is no standard method for applying those factors. Usually, factors are applied individually by an experience or custom of each engineer. In this study, the authors emphasize the meaning and the problem of those factors, examine them by analyzing factors which were applied to actual practices, and propose the recommendation value of safety, load, operation factors and application methods.

Damage detection of multi-storeyed shear structure using sparse and noisy modal data

  • Panigrahi, S.K.;Chakraverty, S.;Bhattacharyya, S.K.
    • Smart Structures and Systems
    • /
    • v.15 no.5
    • /
    • pp.1215-1232
    • /
    • 2015
  • In the present paper, a method for identifying damage in a multi storeyed shear building structure is presented using minimum number of modal parameters of the structure. A damage at any level of the structure may lead to a major failure if the damage is not attended at appropriate time. Hence an early detection of damage is essential. The proposed identification methodology requires experimentally determined sparse modal data of any particular mode as input to detect the location and extent of damage in the structure. Here, the first natural frequency and corresponding partial mode shape values are used as input to the model and results are compared by changing the sensor placement locations at different floors to conclude the best location of sensors for accurate damage identification. Initially experimental data are simulated numerically by solving eigen value problem of the damaged structure with inclusion of random noise on the vibration characteristics. Reliability of the procedure has been demonstrated through a few examples of multi storeyed shear structure with different damage scenarios and various noise levels. Validation of the methodology has also been done using dynamic data obtained through experiment conducted on a laboratory scale steel structure.

Integrating Building Information Modeling and Health and Safety for Onsite Construction

  • Ganah, Abdulkadir;John, Godfaurd A.
    • Safety and Health at Work
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2015
  • Background: Health and safety (H&S) on a construction site can either make or break a contractor, if not properly managed. The usage of Building Information Modeling (BIM) for H&S on construction execution has the potential to augment practitioner understanding of their sites, and by so doing reduce the probability of accidents. This research explores BIM usage within the construction industry in relation to H&S communication. Methods: In addition to an extensive literature review, a questionnaire survey was conducted to gather information on the embedment of H&S planning with the BIM environment for site practitioners. Results: The analysis of responses indicated that BIM will enhance the current approach of H&S planning for construction site personnel. Conclusion: From the survey, toolbox talk will have to be integrated with the BIM environment, because it is the predominantly used procedure for enhancing H&S issues within construction sites. The advantage is that personnel can visually understand H&S issues as work progresses during the toolbox talk onsite.

Impact of Reinforced Standard for Envelope Insulation on the Regional Heating and Cooling Energy Consumption (강화된 건물 외피 단열기준의 지역별 냉난방에너지 감소 효과)

  • Moon, Jin-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.646-655
    • /
    • 2011
  • This study aimed at quantifying the impact of the reinforced standard for envelope insulation on heating and cooling energy consumption in a Korean detached house as well as at identifying the effect of regionally subdivided standards. For them, a series of simulations for application of the reinforced standard on respective walls, roof, floor, windows, and all envelopes were computationally conducted for a prototypical detached residential building. In addition, the subdivided standards were applied to each regions-central and southern regions, and the Jeju island. Analysis revealed that heat transfer through envelopes was the most significant source of building heat gain and loss; the reinforced standard effectively reduced heating energy consumptions, especially in central region; and the subdivided standards did not presented a clear difference in the amount of energy consumption for the southern region and the Jeju island, thus, a further study is required to investigate the necessity of regional subdivisions.

Simulation on Energy Consumption in the Summer Season Operation of primary HVAC system for Multipurpose Building Complex (다목적 복합건물의 하절기 열원기기 운전시 소비전력에 관한 시뮬레이션)

  • Suh, Jae-Kyoung;Choi, Seung-Gil;Kang, Chae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.903-908
    • /
    • 2006
  • Building energy simulation has become a useful tool for predicting cooling, heating and air-conditioning loads for facilities. It is important to provide building energy performances feed back to the mechanical and electrical system operator and engineer for energy conservation and maintenance of building. From this research, we set up the typical weather data of location, basic description of building, geometric modelling data and the specification of Installed primary HVAC system for establishing the simulation model about energy consuming that take place in multipurpose building complex. The simulation tool of building energy - EnergyPlus (DOE and BLAST based simulation S/W), it has been used and accomplished calculations and analyses for evaluating the effect of the system types and operating condition of central HVAC plant on the building energy consumption. In this paper, we offer comparison and simultaneous results those involve electricity consumption pattern and amount between actual operation versus EnergyPlus simulation to the object building during summer season.

  • PDF

Research on the Effect of High-Rise Commercial Building Construction on Land Value of Shanghai in the 1920s

  • Sun, Le
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.2
    • /
    • pp.145-154
    • /
    • 2016
  • When the tall office building first appeared in the street of Chicago in the end of Nineteenth Century, this building type has become a commodity in the development of real estate and been defined as a machine that makes the land pay. With the investigation of land price samples of the high-rise commercial buildings and the overall land price development in the central district of International Settlement in Shanghai, this paper tries to examine the site selection and construction of high-rise commercial buildings have important positive effect on the land value development.

A Study on the Original Form and Architectural Elements in the Palace of Yu, Jin gyeong's Hanok (유진경 가옥(현 북촌문화센터)의 원형과 궁궐요소 차용)

  • Park, Sang-Wook
    • Journal of architectural history
    • /
    • v.23 no.5
    • /
    • pp.7-22
    • /
    • 2014
  • It is identified that an initial person who built of 'Seoul Gyedong Modernized Hanok(former Min Hyeong-gi house)' used as 'Bukchon Culture Center' in present, was not Min Hyeong-gi, but his wife, Yu Jin-gyeong, and she built it when 8 years went on after his death(1879~1973), and the construction year was at the gate of Chuseok in 1921. Yu Jin-gyeong was Head Family's Eldest Daughter-in-law in family of Yeo Heung-min who was an influential person at the late Joseon Dynasty and was widow who had only son for 3 generations. And she built this house and moved to gain daughter and live futher grandchilds together in law in new nest. It is arranged that an annex surrounds with main building as the central figure. And this house emulates Yeonkeong-dang in backyard of the Changdeok Palace for 'preservation of main building' and Chim-bang-ga-toe applied on a bedroom in a palace is applied around nobleman family's the main room. It is rare case and expresses that a palace factor is borrowed. Yu Jin-gyeong's house is that a tradition Hanok is adjusted closely in city and central and basing mode as 'protective bedding' and building concept as 'a noble and protective architecture' is realized. So it has a character that development of Hangrang architecture is appeared and Head Family's Eldest Daughter-in-law widow of modern upper class had a special benefit. As well as, a meaning that it is experimental house based on tradition and is build of Hanok with housekeeping as the central figure for appear a form which has minimal Hangrang for housekeeping in yangban family of modern city, can be found.

Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System (중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6759-6765
    • /
    • 2015
  • In this study, the effects of control strategies of night-purge control system on control characteristics and energy consumption for central cooling system in building are researched by simulation. The start time and set-point temperature for night-purge control with outdoor temperature changes and building cold storage performance are obtained. The system analysis modelling is done by using TRNSYS program package, and the control performances with suggested night-purge control method are compared with the existing control ones. As a result, the suggested night-purge control method shows maximum 16.8% and 28.6% energy saving in comparison with existing control method and conventional one without night-purge control, respectively.