• Title/Summary/Keyword: Central Building

Search Result 691, Processing Time 0.027 seconds

The Generation of True Orthophotos from High Resolution Satellites Images

  • Chen, Liang-Chien;Wen, Jen-Yu;Teo, Tee-Ann
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.885-887
    • /
    • 2003
  • The purpose of this investigation is to generate true orthophotos from high resolution satellite images. The major works of this research include 4 parts: (1) determination of orientation parameters, (2) generating traditional orthophotos using terrain model, (3) relief correction for buildings, and (4) process for hidden areas. To determine the position of satellites, we correct the onboard orientation parameters to fine tune the orbit. In the generation of traditional orthophotos, we employ orientation parameters and digital terrain model(DTM) to rectify tilt displacements and relief displacements for terrain. We, then, compute relief displacements for buildings with digital building model (DBM). To avoid double mapping, we detect hidden areas. Due to the satellite’s small field of view, an efficient method for the detection of hidden areas and building rectification will be proposed in this paper. Test areas cover the city of Kaohsiung in southern Taiwan. Test images are from the QuickBird satellite.

  • PDF

A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System (중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구)

  • Jae-Yeob Song;Byung-Cheon Ahn
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

A Simulation Appraisal of Energy Performance in Office Building by Different Types of Air-Conditioning (공조방식에 따른 사무소 건물의 에너지 성능 평가)

  • Choi, Jong-Dae;Choi, Dong-Suk;Yun, Geun-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.612-620
    • /
    • 2012
  • High economic growth causes increase of the building energy consumption. The energy consumption for HVAC system accounts for 40~50% of the whole building consumption. The trend for building is large-scale and high-rise. Because of the trend, the energy consumption is becoming bigger than before. Nowadays, HVAC system design are recognized as the solution for a energy-saving. This paper is focused on the energy performance evaluation of central air-conditioning system(water-based) and system air-conditioning that were applied to the office building. The systems are modeled and simulated by using EnergyPlus Software 6.0. After the Simulation, annual cooling and heating energy consumption were calculated. It was found that the system air-conditioning can reduce the energy consumption approximately 55.24% annually compared with the central air-conditioning system(water-cooled). In addition, about 46.13% of annual operating costs can be reduced by use of system air-conditioning.

Numerical Model for Stack Gas Diffusion in Terrain Containing Buildings - Application of Numerical Model to a Cubical Building and a Ridge Terrain -

  • Sada, Koichi;Michioka, Takenobu;Ichikawa, Yoichi
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.1-13
    • /
    • 2008
  • A numerical simulation method has been developed to predict atmospheric flow and stack gas diffusion using a calculation domain of several km around a stack under complex terrain conditions containing buildings. The turbulence closure technique using a modified k-$\varepsilon$-type model under a non hydrostatic assumption was used for the flow calculation, and some of the calculation grids near the ground were treated as buildings using a terrain-following coordinate system. Stack gas diffusion was predicted using the Lagrangian particle model, that is, the stack gas was represented by the trajectories of released particles. The numerical model was applied separately to the flow and stack gas diffusion around a cubical building and to a two-dimensional ridge in this study, before being applied to an actual terrain containing buildings in our next study. The calculated flow and stack gas diffusion results were compared with those obtained by wind tunnel experiments, and the features of flow and stack gas diffusion, such as the increase in turbulent kinetic energy and the plume spreads of the stack gas behind the building and ridge, were reproduced by both calculations and wind tunnel experiments. Furthermore, the calculated profiles of the mean velocity, turbulent kinetic energy and concentration of the stack gas around the cubical building and the ridge showed good agreement with those of wind tunnel experiments.

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • v.32 no.5
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

Estimation of water unit factor and water demand of domestic airports (공항용수 원단위 산정 및 용수 사용량 추정방법)

  • Kim, Taeyoung;Kim, Taehwan;Huh, Dong;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.231-239
    • /
    • 2009
  • The purpose of this research is to provide more reliable water unit factors of domestic airports by investigating of general informations related to the domestic airport. The informations of domestic airports such as passengers, settled population of airports, building areas and water amount are investigated to estimate the unit factor of water of domestic airports. The domestic airports are divided into three type such as central airport, position airport and general airport. Through analysis of relationship between water amount and the others, the unit factor of water could be calculated. The water amount of central airport as Incheon international airport and position airports could be estimated by unit factor of settled population. The others could be estimated by unit factor of building area.

Evolution, Transformation, and Representation in Buddhist Architecture - The Square Shrines of Buddhist Monasteries in Central Asia after the Fourth Century

  • Kim, Young-Jae;Han, Dong-Soo
    • Architectural research
    • /
    • v.13 no.4
    • /
    • pp.31-42
    • /
    • 2011
  • This study notices that all religions in Central Asia from the fourth century through seventh century C.E. provided considerable hands in keeping a uniform unity through a process of assimilation, although art and architecture were greatly stimulated by the creative genius of the many people. The study thus intends to argue that the common ideas of rituals and primitive forms of religious shrines lead the square-based layout of Buddhist shrines the unity and universality in the architectural products of particular regions or epochs: i.e. the "square-based plan" in Buddhist temples of Central Asia was a significant prototype in the synthesis with pre-Buddhist architectural models and Buddhist universal ideas. Thus, this thesis notes that they did not lose the universal principles of the Buddhist shrine plans due to ritual functions, and even there have been never differences from pre-Buddhist building models remarked by the periods and the venues in which they were produced, although there had been continuous evolutions and adaptive transformations in the local tastes of religious architecture. Accordingly, this study discusses how such plans in Buddhist architecture had been consistently produced within that regional style also representative of the local idioms of architecture, and how they were adopted in the sites, founded on the composition of ritual functions. The foreign architectural cultures were selectively chosen getting along with local building types of each site according to each taste for architecture as a result.

A Study on Planning of The Thai Traditional House - Focus on Central and Northern Region - (태국 전통주택의 평면적 특성에 대한 고찰 - 중부, 북부 지방을 중심으로 -)

  • Ju, Seo-Ryeung;Kim, Bo-Mi
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.97-102
    • /
    • 2011
  • The characteristics of traditional Thai houses are post-and-beam structure, lifted floor on pillars, and gabled roof as like as houses in other Southeast Asia countries. However 'charn', connective terrace among each room, is the most unique element in Thai houses which make the area under the 'charn' cool and useful. In Thailand, there are number of housing types caused by historic, social, cultural and geographic factors. This research is focused on comparative study of planning of traditional Thai houses of central and northern region, which have the biggest differences in between. Thai traditional house in central region has symmetrical arrangement on layout and when family members are added, they extend 'charn' and attach another building. While in Northern region, the 'charn' is located not in the center and in the front, and the direction of the main building is perpendicular to the length direction of the veranda. This research has a limitation to be generalized because just two region in Thailand were analyzed and the numbers of case studies were few. Nevertheless, we expect this paper to be a primary guidance to understand Thai traditional houses and we also expect that our research area will cover the all areas in Thailand and finally expand to conclude the commonality and diversity of traditional houses in Southeast Asia in the future.

  • PDF

A Study on the Improvement of Commercial Building Design in the Central Area of a Small Town - Focused on the Central Rotary District in Geochang-eup - (읍 중심부 상가건물 디자인 개선방향에 관한 연구 - 거창읍 중앙로타리 주변을 대상으로 -)

  • Joo, Woo-Il;Kweon, Hyeon-Cheol;Kim, Keun-Sung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.11 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • Townscape design is now considered to be the most important part in city management as a means to improve the life quality of its dwellers. Therefore, the recognition of local autonomous entities and local residents on townscape has been greatly changed. As a part of this effort, the plan to improve the townscape of the central rotary district in Geochang-eup has been examined in multilateral ways. In this plan, first, improvement for proper buildings was studied. Second, betterment for street furniture around the central rotary was considered. Third, making a landscape square around it was also investigated. Based on those considerations, this article intends to suggest directions for improving the commercial buildings of the central rotary district which has the greatest symbolicity in Geochang-eup. To achieve the goal, this paper conducted a survey to the dwellers beforehand in order to investigate their recognition on creating townscape for the central rotary district and collected their opinions on it. According to the result, among the elements of townscape in the shopping district around the rotary, the externals of the buildings such as signboards, color, and shape and the pleasantness part like the maintenance of telegraph poles occupied the highest portion on the street. And It is proposed 4 Alternative plans for the improvement of commercial building design in the central rotary district of geochang-eup.

  • PDF

Corrosion of Rebar by Chlorides and Concrete Durability

  • Hong, Naifeng
    • Corrosion Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.127-130
    • /
    • 2004
  • Throughout the world, corrosion of rebar in concrete is a main form for concrete building destruction. The chloride is prime criminal. This paper presents the harm of chloride corrosion in China, the effect of chloride corrosion on the durability of concrete buildings and protection strategies for rebar corrosion.