• 제목/요약/키워드: Central Building

검색결과 691건 처리시간 0.031초

Microstructural Organization of the Central Nervous System in the Orb-Web Spider Araneus ventricosus (Araneae: Araneidae)

  • Park, Yong-Ki;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • 제43권2호
    • /
    • pp.65-74
    • /
    • 2013
  • Although the geometrical difference in body position between web-building and wandering spiders could affect the organization of their central nervous system (CNS), however most of our informations about spider's CNS are dependent on those revealed from the wandering spiders. Therefore, this paper describes microstructural organizations of the CNS in the geometric orb-web spider Araneus ventricosus. Similarly to other wandering spiders, the CNS of A. ventricosus is also consisted of a dorsal supraesophageal ganglion and a ventral subesophageal mass. The supraesophageal ganglia are fused together and made up of a large sized nerve cell clusters, whereas the subesophageal ganglia are made up of the foremost part of the ventral nerve cord. It has been revealed that the only nerve arising from the supraesophageal mass was the optic nerve which connected with four pairs of eyes, whereas a pair of pedipalpal and four pairs of appendage nerves including abdominal nerve pairs were arisen from the subesophageal nerve mass. Fibrous masses are highly organized into longitudinal and transverse tracts, and are only consisted of processes of neurons and the terminal ramnifications of peripheral sensory neurons. In addition, central fibrous mass of both the brain and the subesophageal mass are totally devoid of nerve cell bodies.

A Study on the Role of the Regional Central Library for Activating the Regional Public Libraries in Jeollabukdo (전라북도 지역 공공도서관 활성화를 위한 지역 대표도서관의 역할에 관한 연구)

  • Bae, Soon-Ja
    • Journal of Information Management
    • /
    • 제40권3호
    • /
    • pp.23-40
    • /
    • 2009
  • This study aims to seek the role model of the regional central library as the chosen one to activate the regional public libraries by the newly revised law of library. We examined its roles in terms of supports and cooperations on the basis of the survey of the opinions and realizations of librarians working in Jeonbuk area and the analyses of the environmental factors specific to Jeonbuk. And conclude that as the cooperative roles, the regional central library can function as a hub library for the five specific regions in Jeonbuk; as the supportive roles, it can support the educational and cultural activities planning at the regional public libraries by building a pool for knowledge and information in Jeonbuk region.

Further analysis on the flexural behavior of concrete-filled round-ended steel tubes

  • Ding, Fa-xing;Zhang, Tao;Wang, Liping;Fu, Lei
    • Steel and Composite Structures
    • /
    • 제30권2호
    • /
    • pp.149-169
    • /
    • 2019
  • A new form of composite column, concrete-filled round-ended steel tubes (CFRTs), has been proposed as piers or columns in bridges and high-rise building and has great potential to be used in civil engineering. Hence, the objective of this paper presents an experimental and numerical investigation on the flexural behavior of CFRTs through combined experimental results and ABAQUS standard solver. The failure mode was discussed in detail and the specimens all behaved in a very ductile manner. The effect of different parameters, including the steel ratio and aspect ratio, on the flexural behavior of CFRTs was further investigated. Furthermore, the feasibility and accuracy of the numerical method was verified by comparing the FE and experimental results. The moment vs. curvature curves of CFRTs during the loading process were analyzed in detail. The development of the stress and strain distributions in the core concrete and steel tube was investigated based on FE models. The composite action between the core concrete and steel tube was discussed and clarified. In addition, the load transfer mechanism of CFRT under bending was introduced comprehensively. Finally, the predicted ultimate moment according to corresponding designed formula is in good agreement with the experimental results.

Aerodynamic shape optimization emphasizing static stability for a super-long-span cable-stayed bridge with a central-slotted box deck

  • Ledong, Zhu;Cheng, Qian;Yikai, Shen;Qing, Zhu
    • Wind and Structures
    • /
    • 제35권5호
    • /
    • pp.337-351
    • /
    • 2022
  • As central-slotted box decks usually have excellent flutter performance, studies on this type of deck mostly focus on the vortex-induced vibration (VIV) control. Yet with the increasing span lengths, cable-supported bridges may have critical wind speeds of wind-induced static instability lower than that of the flutter. This is especially likely for bridges with a central-slotted box deck. As a result, the overall aerodynamic performance of such a bridge will depend on its wind-induced static stability. Taking a 1400 m-main-span cable-stayed bridge as an example, this study investigates the influence of a series of deck shape parameters on both static and flutter instabilities. Some crucial shape parameters, like the height ratio of wind fairing and the angle of the inner-lower web, show opposite influences on the two kinds of instabilities. The aerodynamic shape optimization conducted for both static and flutter instabilities on the deck based on parameter-sensitivity studies raises the static critical wind speed by about 10%, and the overall critical wind speed by about 8%. Effective VIV countermeasures for this type of bridge deck have also been proposed.

Alternative Strategies to Central Heating Ventilation and Air Conditioning

  • Shrestha, Pramen P.;Prgada, Mythili
    • International conference on construction engineering and project management
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.401-407
    • /
    • 2022
  • Central heating, ventilation and air conditioning (HVAC) is one of the largest consumers of energy in the residential sector. This project explores the use of multiple HVAC units and/or Zoning in a single residence to reduce energy loads. The energy consumption data of a detached single-family home using two HVAC units, one primary for the main house and a secondary HVAC for a casita, was collected for the same month for two consecutive years, along with details related to the outdoor temperature and the square footage being air-conditioned by each HVAC. A regression algorithm was trained using the above details to find the relation between the parameters. Next, based on the occupancy and usage patterns, the HVAC was redesigned assuming more area under the secondary HVAC unit. The trained algorithm was then used to make energy usage predictions for the revised primary HVAC area, with the assumption that the secondary HVAC unit was turned off. The results were compared with existing energy usage data. It was determined that there were significant energy savings in the second scenario. It is expected that this study and its findings will help future research projects explore more ideas as alternatives to central HVAC, in improving the economic viability of existing options, and in developing a savings calculation tool that will help consumers make informed decisions on their best alternatives to central HVAC.

  • PDF

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • 제29권6호
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

A Study on the Foundations of Wooden Pagodas of 'Kokubunji' in Japan (일본 국분사 목탑의 하부구조 고찰)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • 제19권5호
    • /
    • pp.81-98
    • /
    • 2010
  • In the middle of the 8th century, we met the new high-rise building, the 7th storied wooden pagodas in 'Kokubunji' in Japan. I tried to analyze and study this building to show how the wooden pagoda had changed itself because of appearance of new style. The conculusions are as follows; 1. The construction of the foundation was mainly composed namely 'Panchuk'. It was proceeded by two ways. One is the earthen-digging, laying foundations named 'Gulkwangpachuk' and the other is simply laying foundation named 'Jisangpanchuk'. In that period, due to the progress of the technique, we assumed that the main stream is 'Jisangpanchuk'. 2. The elevation of base was mostly the single foundation from archaeological study. The material was stone. The middle case of pagoda had the base of tile-roofed. We knew the just one pagoda had the base of brick, but that was not main stream. 3. The new device had appeared in the central base stone. It was the stone point. But in that period the existing method, a hole style and the new style was used in the central base stone. This fact is showed that the central government was not hold the reigon(it names 'Kook') in the respect of the technique. 4. The plan scale is classified of 3 group. As a result, the first body is larger, the main-unit and the sub-unit is a equal unit. But smaller, the length of main-unit is longer than the one of sub-unit. And the very small pagoda was build in that period.

Optimal Control Strategies for Energy Saving of Central Cooling System with Outdoor Air Temperature Changes (외기온도 변화특성을 고려한 중앙냉방시스템의 에너지 절감 최적제어에 관한 연구)

  • Park, Ki-Tae;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권6호
    • /
    • pp.4260-4266
    • /
    • 2015
  • In this study, the optimal control method for minimizing of energy consumption for central cooling system with proper occupant comfort level is researched by simulation. The optimal control method is that the optimal set temperatures such as the condenser water temperature, supply air temperature, and chilled water temperature with environment variable change such as outdoor air dry-bulb and wet-bulb temperatures are obtained by suggested optimal control algorithm with maximum and part building load. The TRNSYS program is used for system modeling and the control performances with the suggested optimal control method are compared with the existing control method of fixed set points. The suggested optimal control method shows better responses in energy consumption in comparison with existing control ones.

Analysis on the Characteristics of Activity Areas in Classrooms of Childcare Centers Depending on Age Groups (어린이집 사례분석에 의한 연령별 보육실의 흥미영역 특성분석)

  • Park, Jung-A;Choi, Mock-Wha
    • Journal of the Korean housing association
    • /
    • 제23권1호
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study is to find out the characteristics of activity areas according to the age difference and provide the alternatives for space planning of activity areas in classroom of childcare centers. This study used the content analysis method for field survey data collected from 36 classrooms of 9 childcare centers in the Daejeon area. Floor plans were converted to Autocad drawings to analyze the characteristics of activity areas. The results of this study were as follows; 1) In case of 0 to 2-year-old classrooms, they had 6 activity areas such as gross-motor area, role play, block building, language, creative expression, exploration/manipulation area. The activity area with the most low frequency was gross-motor area. 2) In case of 0 to 2-year-old classrooms, the size of activity area was in order of gross-motor area > role play > block building > language > creative expression > exploration/manipulation area. In case of 3 to 5-year-old classrooms, the size of activity area was in order of language > art > role play > math > block building > science > tone and rhythmic area. 3) The central areas with easy access in 0 to 2-year-old classrooms were Large-motor and Imaginary Play Areas. Also, more isolated areas were Manupulatives and Block Areas. The central areas with easy access in 3 to 5-year-old classrooms were Arts, Numbers and Manupulatives. While more isolated areas were Music, Movement and Science Areas.

The Characteristics of Spatial Configuration of Activity Areas in Classrooms According to the Types of Daily Routine in Child-Care Centers in South Korea (어린이집 일과유형에 따른 보육실 흥미영역구성 특성)

  • Park, Jung-A;Choi, Mock Wha
    • Journal of the Korean housing association
    • /
    • 제25권4호
    • /
    • pp.83-91
    • /
    • 2014
  • The purpose of this study is to clarify the characteristics between the type of daily routine and spatial configuration of activity areas in classroom and provide alternatives for space planning of activity areas in classroom of child-care centers. This study used the content analysis on daily activity plan and floor plans through field survey. Analysis on floor plans was conducted for 35 classrooms in 9 child-care centers which allowed field survey. The results of this study were as follows; There was no significant difference for classroom size according to the type of daily routine in 3 to 5-year-old classrooms. The average size of classrooms was $61.6m^2$ for care oriented type, $41.4m^2$ for indoor activity oriented type and $48.8m^2$ for group activity oriented type. There was no significant difference in composition of activity areas in classrooms according to the type of daily routine. In case of 0 to 2-year-old classrooms, they were composed of 6 activity areas including gross-motor, role play, block building, language, creative expression, exploration/manipulation. Activity area of the most low frequency was gross-motor area. In case of 3 to 5-year-old classrooms, most classrooms were composed of all the 7 activity areas including art, tone and rhythmic, block building, role play, language, math and science. Most accessible and central areas in 0 to 2-year-old classrooms were gross-motor and role play. Also, most separate areas were exploration/manipulation and block building. Most accessible and central areas in 3 to 5-year-old classroom were art and math. Also, most separate areas were tone and rhythmic and science.