• Title/Summary/Keyword: Center X-ray angle

Search Result 136, Processing Time 0.027 seconds

A Clinical Study on Patients of Scoliosis (척추측만증 환자에 관한 임상적 고찰)

  • Park, Min-Jung;Seo, Jin-Woo;Park, Kwae-Hwan;Lee, Kyung-Yun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.205-211
    • /
    • 2004
  • Objective : This study is designed to provide clinical data about patients of scoliosis for clinicians. Methods : We investigated 112 patients who have signs and symptoms of scoliosis. visited Vertebral -Joint Center of Conmaul Oriental Medical Hospital from January 2003 to July 2004. We measured Cobb's angle in the 112 patients' X-ray of full spine AP and lateral view and also analyzed age, sex, chief complaints. Results : 1. We investigated 72 female and 40 male patients. The most common distribution of age was 20's in both sex. 2. In the scoliosis angle : The average scoliosis angle was $9.27^{\circ}{\pm}6.06^{\circ}$ in 112 patients. The average scoliosis angle of 40 male patients was$8.9^{\circ}{\pm}6.77^{\circ}$. The average scoliosis angle of 72 female patients was $9.48^{\circ}{\pm}5.67^{\circ}$. 3. The most common region of scoliosis was thoracic spine with 37 patients. 4. The most common chief complaint was low back pain with 69 patients. In the 48 patients. self awareness of scoliosis was included in the chief complaint.

  • PDF

Study on Methods of Enhancement and Measurement of Corrosion Resistance for Subsea Equipment made of Aluminum (알루미늄으로 제작된 심해 장비의 부식 저항 능력 향상 방법 및 측정 방법 조사)

  • Seo, Youngkyun;Jung, Jung-Yeul
    • Plant Journal
    • /
    • v.16 no.3
    • /
    • pp.47-52
    • /
    • 2020
  • This study investigated the methodologies to enhance the corrosion resistance and the ways to measure for subsea equipment made of aluminum. The methodologies for the anticorrosion were cathodic protection, conversion coating, anodizing and organic coating. The simply analyzed ways to measure the corrosion resistance were Scanning Electron Microscope (SEM), Electrochemical Impedance Spectroscopy (EIS), Glow discharge optical emission spectrum spectroscopy (GD-OES), Fourier Transform Infrared Spectroscopy (FT-IR), Transmission Electron Microscopy (TEM), X-ray Photoelectron Spectroscopy (XPS), Scanning Vibrating Electrode Technique (SVET), contact angle and interfacial tension. The most widely used tools for increasing the corrosion resistance were the anodizing and the organic coating. Many ways were evenly used to measure corrosion. The methods more frequently utilized were SEM for the surface investigation and the contact angle to evaluate the corrosion resistance.

Atomic-scale Controlled Epitaxial Growth and Characterization of Oxide Thin Films

  • Yang, G.Z.;Lu, H.B.;Chen, F.;Zhao, T.;Chen, Z.H.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.6-11
    • /
    • 2001
  • More than ten kinds of oxide thin films and their heterostructure have been successfully fabricated on SrTiO$_3$(001) substrates by laser molecular beam epitaxy (laser MBE). Measurements of atomic force microscopy (AFM), high-resolution transmission electron microscopy (HRTEM) and X-ray small-angle reflectivity reveal that the surfaces and interfaces are atom-level-smooth. The unit cell layers and the lattice structure are perfect. The electrical and optical properties of BaTiO$_3$-x thin films and BaTiO$_3$/SrTiO$_3$ (BTO/STO) superlattices were examined. The all-perovskite oxide P-N junctions have been successfully fabricated and the better I-V curves were observed.

  • PDF

X-ray Scattering Studies on the Structure of Porcine Pepsin in Various pH Solutions

  • Jin, Kyeong-Sik;Jin, Sang-Woo;Yoon, Jin-Hwan;Heo, Kyu-Young;Kim, Jae-Han;Kim, Hee-Soo;Ree, Moon-Hor
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.348-348
    • /
    • 2006
  • In the present study, porcine pepsin in various pH conditions was investigated by small-angle X-ray scattering (SAXS) in order to detailed information on the structure and its variations with pH conditions. These analyses identified the structure of pepsin, and compared with that obtained by single crystallography. Moreover, this study found the structure' variations with changing pH conditions. All the results will be discussed with considering the conformational characteristics of pepsin in solution and further correlate to the biological and spectroscopic characteristics reported previously.

  • PDF

Improvement of Superhydrophobicity of Multi-Walled Carbon Nanotubes Produced by Fluorination

  • Meng, Long-Yue;Park, Soo-Jin
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.178-181
    • /
    • 2012
  • In this work, we synthesized superhydrophobic coatings by chemical surface functionalization of multi-walled carbon nanotubes (MWCNTs). This was accomplished through the radical polymerization of 3-(trimethoxysilyl) propyl methacrylate modified MWCNTs and fluoro acrylate/methyl methacrylate. The chemical compositions and microstructures of the prepared MWCNT surface were investigated using X-ray photoelectron spectroscopy, Fourier transform infrared spectrometry, and scanning electron microscopy, respectively. The wettability of the MWCNTs surface was determined through contact angle assessments in different liquids. The resulting surface exhibited a water contact angle of $157.7^{\circ}$, which is clear evidence of its superhydrophobicity. The 3D MWCNT networks and the low surface energy of the -C-C- and -C-F- groups play important roles in creating the superhydrophobic surface of the MWCNTs.

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

One-pot synthesis of PdAu bimetallic composite nanoparticles and their catalytic activities for hydrogen peroxide generation

  • Xiao, Xiangyun;Kang, Tae-Uook;Nam, Hyobin;Bhang, Suk Ho;Lee, Seung Yong;Ahn, Jae-Pyung;Yu, Taekyung
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2379-2383
    • /
    • 2018
  • We report a facile one-pot aqueous-phase synthesis of PdAu bimetallic nanoparticles with different Pd/Au ratio. The synthesis was conducted by co-reduction of Pd and Au precursor using ascorbic acid as a reducing agent and in the presence of polyallylamine hydrochloride (PAH). By high-angle annular dark field scanning transmission electron microscopy (HAADF-STEM) and energy-dispersive X-ray spectrometry (EDS) analyses, we found that the synthesized nanoparticles had an onion-like core/shell/shell/shell structure with Au-rich core, Pd-rich shell, Au-rich shell, and Pd shell, respectively. We also investigated the catalytic performance of the synthesized PdAu nanoparticles toward hydrogen peroxide generation reaction.

Physico-mechanical, AC-conductivity and microstructural properties of FeCl3 doped HPMC polymer films

  • Prakash, Y.;Somashekarappa, H.;Manjunath, A.;Mahadevaiah, Mahadevaiah;Somashekar, R.
    • Advances in materials Research
    • /
    • v.2 no.1
    • /
    • pp.37-49
    • /
    • 2013
  • The transition metal salt doped solid polymer electrolyte [TSPE] were prepared with HPMC as a host polymer. The virgin and doped films were prepared by solution-casting method and investigated using wide angle X-ray scattering method. Micro structural parameters like lattice strain (g%), stacking/twin faults, the average number of unit cells counted in a direction perpendicular to the Bragg's plane (hkl) spacing of (hkl) planes dhkl, crystallite size Ds, distortion width, standard deviation were determined by whole pattern powder fitting (WPPF) method, which is an extension of single order method. It is found that the crystallite size decreases with the increase in the content of $FeCl_3$. This decrease is due to increase in localized breaking of polymer network which also accounts for the amorphous nature of the material. The filler inorganic salt $FeCl_3$ acts as plasticizer. FTIR study also confirms and justifies the interaction between the polymer and in-organic salt in the matrix. Physical properties like mechanical stability and Ac conductivity in these films are in conformity with the X-ray results.

High Crystalline Epitaxial Bi2Se3 Film on Metal and Semiconductor Substrates

  • Jeon, Jeong-Heum;Jang, Won-Jun;Yun, Jong-Geon;Gang, Se-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.302-302
    • /
    • 2011
  • The binary chalcogenide semiconductor Bi2Se3 is at the center of intensive research on a new state of matter known as topological insulators. It has Dirac point in their band structures with robust surface states that are protected against external perturbations by strong spin-orbit coupling with broken inversion symmetry. Such unique band configurations were confirmed by recent angle-resolved photoelectron emission spectroscopy experiments with an unwanted n-type doping effect, showing a Fermi level shift of about 0.3 eV caused by atomic defects such as Se vacancies. Since the number of defects can be reduced using the molecular beam epitaxy (MBE) method. We have prepared the Bi2Se3 film on noble metal Au(111) and semiconductor Si(111) substrates by MBE method. To characterize the film, we have introduced several surface sensitive techniques including x-ray photoemission electron spectroscopy (XPS) and micro Raman spectroscopy. Also, crystallinity of the film has been confirmed by x-ray diffraction (XRD). Using home-built scanning tunneling microscope, we observed the atomic structure of quintuple layered Bi2Se3 film on Au(111).

  • PDF

Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery (Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정)

  • Chu Sung Sil;Suh Chang Ok;Loh John J.K.;Chung Sang Sup
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF