• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.039 seconds

Sapphire Based 94 GHz Coplanar Waveguide-to-Rectangular Waveguide Transition Using a Unilateral Fin-line taper (평면형 Fin-line 테이퍼를 이용한 사파이어 기반의 94 GHz CPW-구형 도파관 변환기)

  • Moon, Sung-Woon;Lee, Mun-Kyo;Oh, Jung-Hun;Ko, Dong-Sik;Hwang, In-Seok;Rhee, Jin-Koo;Kim, Sam-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.10
    • /
    • pp.65-70
    • /
    • 2008
  • We design and fabricate the 94 GHz Coplanar waveguide(CPW)-to-rectangular waveguide transition that is transmits signal smoothly between the CPW, which is a popular transmission line of the planar circuits, and rectangular waveguide for the 94 GHz transceiver system. The proposed transition composed of the unilateral fin-line taper and open type CPW-to-slot-line transition is based on the hard and inflexible sapphire for the flip-chip bonding of the planar MMICs using conventional MMIC technology. We optimize a single section transition to achieve low loss by using an EM field solver of Ansoft's HFSS and fabricate the back- to-back transition that is measured by Anritsu ME7808A Vector Network Analyzer in a frequency range of $85{\sim}105$ GHz. From the measurement and do-embedding CPW with 3 mm length, an insertion and return loss of a single-section transition are 1.7 dB and more an 25 than at 94 GHz, respectively.

Definitive radiotherapy with or without chemotherapy for clinical stage T4N0-1 non-small cell lung cancer

  • Kim, Yeon Joo;Song, Si Yeol;Jeong, Seong-Yun;Kim, Sang We;Lee, Jung-Shin;Kim, Su Ssan;Choi, Wonsik;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.284-293
    • /
    • 2015
  • Purpose: To determine failure patterns and survival outcomes of T4N0-1 non-small cell lung cancer (NSCLC) treated with definitive radiotherapy. Materials and Methods: Ninety-five patients with T4N0-1 NSCLC who received definitive radiotherapy with or without chemotherapy from May 2003 to October 2014 were retrospectively reviewed. The standard radiotherapy scheme was 66 Gy in 30 fractions. The main concurrent chemotherapy regimen was $50mg/m^2$ weekly paclitaxel combined with $20mg/m^2$ cisplatin or AUC 2 carboplatin. The primary outcome was overall survival (OS). Secondary outcomes were failure patterns and toxicities. Results: The median age was 64 years (range, 34 to 90 years). Eighty-eight percent of patients (n = 84) had an Eastern Cooperative Oncology Group performance status of 0-1, and 42% (n = 40) experienced pretreatment weight loss. Sixty percent of patients (n = 57) had no metastatic regional lymph nodes. The median radiation dose was EQD2 67.1 Gy (range, 56.9 to 83.3 Gy). Seventy-one patients (75%) were treated with concurrent chemotherapy; of these, 13 were also administered neoadjuvant chemotherapy. At a median follow-up of 21 months (range, 1 to 102 months), 3-year OS was 44%. The 3-year cumulative incidences of local recurrence and distant recurrence were 48.8% and 36.3%, respectively. Pretreatment weight loss and combined chemotherapy were significant factors for OS. Acute esophagitis over grade 3 occurred in three patients and grade 3 chronic esophagitis occurred in one patient. There was no grade 3-4 radiation pneumonitis. Conclusion: Definitive radiotherapy for T4N0-1 NSCLC results in favorable survival with acceptable toxicity rates. Local recurrence is the major recurrence pattern. Intensity modulated radiotherapy and radio-sensitizing agents would be needed to improve local tumor control.

Ten-year Clinical Study of Chorionic Villus Sampling (융모막 융모생검 511례에 대한 임상적 연구: 10년(2000-2010년)간의 경험)

  • Kim, Soo-Hyun;Shim, Sung-Han;Baek, Jong-Woo;Cha, Dong-Hyun
    • Journal of Genetic Medicine
    • /
    • v.8 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • Purpose: We evaluated indications for chorionic villus sampling (CVS), the positive predictive value of CVS for fetal chromosomal abnormalities, and the fetal loss rate after CVS at CHA Medical Center. Materials and Methods: We reviewed the medical records of 511 cases of CVS performed between 67 and 120 days of gestation for prenatal cytogenetic diagnosis from April 2000 to April 2010. Fetal karyotypes were obtained by direct and indirect culture methods. Results: The most common indications for CVS were abnormal ultrasonic findings including increased nuchal translucency (294/635, 46.3%). The positive predictive value of abnormal karyotyping according to indication for CVS was highest in cases with abnormal parental karyotypes (14/21, 66.7%). Mosaicism revealed by CVS comprised 3.1% of the sample (16/509). Amniocentesis revealed two cases of true mosaicism and 11 cases of confined placental mosaicism. The fetal loss rate within 4 weeks of the procedure was 1.2% (6/511). Conclusion: If CVS is performed by an expert clinician, it is a feasible and reliable procedure for prenatal genetic diagnosis. When CVS indicates mosaicism, the finding should be confirmed by amniocentesis to distinguish true mosaicism from confined placental mosaicism.

Characteristics of Aqueous Ammonia-CO2 reaction at Regeneration Condition of High Temperature and Pressure (고압고온 재생조건에서의 암모니아수-CO2 반응특성)

  • Kim, Yun Hee;Yi, Kwang Bok;Park, Sung Youl;Ko, Chang Hyun;Park, Jong-Ho;Beum, Hee Tae;Han, Myungwan;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.253-258
    • /
    • 2010
  • In the field of the $CO_2$ absorption process using aqueous ammonia, the effects of regeneration pressure and temperature on $CO_2$ absorption performances of the aqueous ammonia were investigated. The absorbents were prepared by dissolving ammonium carbonate solid in water to grant the resulted solution 0.5 $CO_2$ loading ($mol\;CO_2/mol\;NH_3$) and various ammonia concentration (14, 20, 26 and 32 wt%). As-prepared absorbents were regenerated at high pressure and temperature (over $120^{\circ}C$ and 6 bar) before the absorption test. The absorption test was carried out by injecting the simulated gas that contains 12 vol% of $CO_2$ into a bubbling reactor. The introduction of 26 wt% of the ammonia concentration for $CO_2$ absorption test resulted in the higher absorption capacities than other experimental conditions. In particular, when the absorbents with 26 wt% of the ammonia were regenerated at $150^{\circ}C$ and 14 bar, the highest absorption capacity, $45ml\;CO_2/g$, was obtained. According to the analysis of absorbents using acid-base titration, the ammonia loss during the regeneration of the absorbents with a fixed ammonia concentration decreased as the regeneration pressure increased, while it increased as the regeneration temperature increased. In the condition of fixed regeneration pressure and temperature, as expected, the ammonia loss increased as the ammonia concentration increased. The measured $CO_2$ loadings and ammonia concentrations of absorbents were compared to the values calculated by Electrolyte NRTL model in Aspen Plus.

Toe entrapment and injury by plastic color rings in a Pale Thrush (Turdus pallidus) and a Light-vented Bulbul (Pycnonotus sinensis) (플라스틱 유색가락지에 의한 흰배지빠귀(Turdus pallidus)와 검은이마직박구리(Pycnonotus sinensis)의 발가락 끼임과 부상)

  • Choi, Chang-Yong;Park, Chang-uk;Nam, Hyun-Young;Park, Se-Young;Bing, Gi-Chang;Cho, Sook-Young;Park, Jong-Gil
    • Korean Journal of Ornithology
    • /
    • v.25 no.2
    • /
    • pp.82-86
    • /
    • 2018
  • Color rings have been commonly and widely used in many ecological and ornithological studies in the field, but color ring-induced injury in passerines is poorly documented. In this report, we describe the first case of toe loss caused by a dislocated split Darvic ring in a Pale Thrush (Turdus pallidus) that was recaptured 596 days after its initial capture and release on Hong-do Island, the Republic of Korea. We also found that a left hind toe of a Light-vented Bulbul (Pycnonotus sinensis) was entrapped by a split color ring when the bird was observed 135 days after the marking at Heuksan-do Island. Based on these two cases out of the 1,900 color ringed birds, we emphasize a precautionary approach following general guidelines in the application and use of color leg rings for future studies.

Correlation between Surface Electromyography and Conventional Electromyography in Facial Nerve Palsy (안면마비 환자에서 표면 근전도 검사와 통상적 근전도 검사간 상관관계)

  • Jang, Haneul;Yoo, Seung Don;Lee, Jong Ha;Soh, Yunsoo;Kim, Dong Hwan;Chon, Jinmann;Lee, Seung Ah;Kim, Hee-Sang;Yun, Dong Hwan;Kwon, Jung Ho
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.84-90
    • /
    • 2018
  • Objective: To assess the correlation between surface electromyography (SEMG) and conventional EMG in patients with facial nerve palsy. Additionally, compare the discomfort and the time required by the patients in two methods. Method: 36 patients with facial palsy were given nerve conduction studies (NCS) via conventional EMG. Then, the peak root mean square (RMS) values were obtained from the SEMG. We also recorded visual analogue scale (VAS), House-Brackmann scale, and the time required for the examination. Results: Pearson's correlation coefficient between the amplitude loss ratio of the RMS values obtained by SEMG compared to the unaffected side (RSEMG) and the amplitude loss ratio of CMAP amplitudes compared to the unaffected side (RCMAP) was 0.567 at the frontalis, 0.456 at the orbicularis oculi, 0.393 at the nasalis, and 0.437 at the orbicularis oris. An increase in RSEMG is positively correlated with an increase in RCMAP. The mean VAS score with conventional EMG was $3.55{\pm}1.42$, whereas that experienced when using SEMG was $0.11{\pm}0.52$ and the mean time required for conventional EMG was $610{\pm}103.84$ seconds, while that required for SEMG was $420{\pm}86.32$ seconds. Conclusion: This study demonstrated a significant positive correlation between facial muscle activities as measured by SEMG and conventional EMG in patients with facial nerve palsy. SEMG has the benefits of being more comfortable and faster when diagnosing facial palsy.

Microstructure Evolution and Dielectric Characteristics of CaCu3Ti4O12 Ceramics with Sn-Substitution

  • Kim, Cheong-Han;Oh, Kyung-Sik;Paek, Yeong-Kyeun
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.1
    • /
    • pp.87-91
    • /
    • 2013
  • The doping effect of Sn on the microstructure evolution and dielectric properties was studied in $CaCu_3Ti_{4-x}Sn_xO_{12}$ polycrystals. Samples were produced by a conventional solid-state reaction method. Sintering was carried out at $1115^{\circ}C$ for 2-16 h in air. The dielectric constant and loss were examined at room temperature over a frequency range between $10^2$ and $10^6$ Hz. The microstructure was found to evolve into three stages. Addition of $SnO_2$ led to an increase in density and advanced formation of abnormal grains. The formation of coarse grains with a reduced thickness of the boundary brought about an enhanced dielectric constant and a lower dielectric loss below ~1 kHz. EDS data showed the Cu-rich phase along the grain boundary, which should contribute to the improved dielectric constant according to the internal barrier layer capacitor model. After all, $SnO_2$ was an effective dopant to elevate the dielectric characteristics of $CaCu_3Ti_{4-x}Sn_xO_{12}$ polycrystals as a promoter for abnormal grain growth.

The effect of aging on the quality of Semimembranosus muscle from Hanwoo

  • Kim, Sun Hyo;Kim, Hyun Joo;Lee, Hyun Jung;Yong, Hae In;Jo, Cheorun;Nam, Ki Chang;Jung, Samooel
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.1
    • /
    • pp.61-71
    • /
    • 2016
  • The effect of postmortem aging on the quality of Semimembranosus muscle (SM) from Hanwoo was investigated. The quality of SM was compared with that of Longissimus dorsi muscle (LD). SM contained higher moisture, protein, and ash, and lower fat than LD (p<0.05). The $a^*$ and $b^*$ values of SM were significantly decreased after 21 days of aging. SM showed higher $a^*$ values than LD at 1 and 7 day of aging (p<0.05). The cooking loss of SM was not affect by aging. SM had higher cooking loss than that of LD throughout the aging period. Although the shear force of SM was significantly decreased by aging, SM showed high shear force compared to LD during aging period (p<0.05). Aging increased lipid oxidation in both muscles (p<0.05). However, TBARS value of SM was significantly lower than that of LD throughout the aging period (p<0.05). There was no effect of aging on the betaine and L-carnitine contents of SM. SM contained higher betaine and L-carnitine than LD in all aging days (p<0.05). Therefore, we concluded that consumer acceptability of SM could be increased by aging based on the increase of tenderness in addition to its high nutritional properties.

High-Isolation Ka-Band Power Combiner Using a Resistive Septum Inserted in a Slit of Waveguide (홈을 가진 도파관에 결합된 저항성 격막을 이용한 높은 격리도 특성의 Ka-대역 전력합성기)

  • Kim, Choul-Young;Shin, Im-Hyu;Lee, Man-Hee;Joo, Ji-Han;Lee, Sang-Joo;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.335-342
    • /
    • 2012
  • A high-isolation Ka-band WR-28 waveguide power combiner is designed and implemented using a resistive septum. The waveguide power combiner developed here is an E-plane T-junction type with a TaN resistive septum inserted in a slit of waveguide junction. The fabricated waveguide power combiner shows a return loss better than -20 dB and an insertion loss less than 0.1 dB. Also the measurement shows isolation levels of 20 dB or more almost all over the band and in particular 25 dB or more below 37 GHz. The amplitude and phase imbalance are measured to be less than 0.1 dB and $2.5^{\circ}$, respectively.

V-Band filter using Multilayer MCM-D Technology (MCM-D 공정기술을 이용한 V-BAND FILTER 구현에 관한 연구)

  • Yoo Chan-Sei;Song Sang-Sub;Part Jong-Chul;Kang Nam-Kee;Cha Jong-Bum;Seo Kwang-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.9 s.351
    • /
    • pp.64-68
    • /
    • 2006
  • Novel system-on-package (SOP) - D technology to improve the mechanical and thermal properties of a MCM-D substrate was suggested. Based on this investigation, the two types of band pass filters for the V-band application with unique structure were designed and implemented using 2-metals, 3-BCB layers. The first type using distributed resonator had the insertion loss below 2.6 dB at 55 GHz and group delay was below 0.06 ns. For the second type with edge coupled structure, the insertion loss and group delay were 3 dB and 0.1 ns, respectively. Suggested MCM-D substrate with band pass filter can be used to evaluate mm-Wave system including flip-chip bonded MMIC.